Room Air Conditioner
SVC MANUAL(Exploded View)
MODEL : TS-C2425DA1 TS-C2425ML1
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
http://biz.lgservice.com
2 Room Air Conditioner
1. Specification
Note:
O
: Applied, - : No relation
*
For circuit breaker rating, please conform to local standards wherever necessary.
Some of functions are slightly different depending upon models.
The specification may be subject to change without prior notice for purpose of
improvement.
Product Model TS-C2425DA1
Sales Model SJ242CD
Capacity
Cooling Capacity
Btu/h
24000
Heating Capacity
Btu/h
-
Electrical Parts
Voltage. Frequency/Phase
Φ / V / Hz
1,220V,60Hz
Power Input Cooling W
2560
Heating W
-
Running Current Cooling A
12.0
Heating A
-
Performance
EER Cooling
Btu/h
9.38
COP Heating
W/W
-
Air Circulation
Indoor,Max
/min(cfm)
14.5
Outdoor,Max
/min(cfm)
42
Moisture Removal l/h
2.9
Sound Level
Indoor,H/M/L dB(A)+3
44
Outdoor,Max dB(A)+3
57
Feature
Neo Plasma Air Purifying System
N
Anti Corrasion
N
Temperature Control
Y
CHAOS Wind(Auto Wind)
N
Airflow Direction Control(up&down)
Auto
Airflow Direction Control(left&right)
Manual
Remocon Type
Wireless Simple
Setting Temperature Range Cooling
18-30
Heating
-
Auto Chage Over
N
Auto Clean
N
Seps,Fan/Cool
3/4
Temperature Increment
1
o
C
Timer
7Hr,Off
Sleep Operation
Y
Restart Delay(Minute)
3
Hot start
-
Jet Cool
Y
Compressor Type
Rotary,TS35N(Mitsubishi)
Installation & Stuffing
Net Dimensions WxHxD mm
1090*314*190/801*555*262
Net Weight Indoor/Outdoor kg
14/51
Service Manual 3
1. Specification
Note:
O
: Applied, - : No relation
*
For circuit breaker rating, please conform to local standards wherever necessary.
The specification may be subject to change without prior notice for purpose of
improvement.
Some of functions are slightly different depending upon models.
Product Model TS-C2425ML1
Sales Model SP242CM
Capacity
Cooling Capacity
Btu/h
24000
Heating Capacity
Btu/h
-
Electrical Parts
Voltage. Frequency/Phase
Φ / V / Hz
1,220V,60Hz
Power Input Cooling W
2560
Heating W
-
Running Current Cooling A
12.0
Heating A
-
Performance
EER Cooling
Btu/h
9.38
COP Heating
W/W
-
Air Circulation
Indoor,Max
/min(cfm)
14.5
Outdoor,Max
/min(cfm)
42
Moisture Removal l/h
2.9
Sound Level
Indoor,H/M/L dB(A)+3
44
Outdoor,Max dB(A)+3
57
Feature
Neo Plasma Air Purifying System
Y
Anti Corrasion
N
Temperature Control
Y
CHAOS Wind(Auto Wind)
New Chaos
Airflow Direction Control(up&down)
Auto
Airflow Direction Control(left&right)
Manual
Remocon Type
Wireless LCD
Setting Temperature Range Cooling
18-30
Heating
-
Auto Chage Over
N
Auto Clean
N
Seps,Fan/Cool
3/4
Temperature Increment
1
o
C
Timer
7Hr,Off
Sleep Operation
Y
Restart Delay(Minute)
3
Hot start
-
Jet Cool
Y
Compressor Type
Rotary,TS35N(Mitsubishi)
Installation & Stuffing
Net Dimensions WxHxD mm
1090*314*190/801*555*262
Net Weight Indoor/Outdoor kg
14/51
4 Room Air Conditioner
2. Piping Diagrams
Indoor Unit Outdoor Unit
Heat
Exchanger
(Evaporator)
Heat
Exchanger
(Condenser)
Capillary Tube
Compressor
Accumulator
Gas Side
3-Way Valve
2-Way Valve
Liquid Side
Cooling
High Pressure S/W
Th1
Th2
rotcennoC BCPnoitpircseD.COL
Th1 Thermistor for indoor air temperature
CN-TH1
Th2 Thermistor for evaporating temperature
TINUROODTUOTINUROODNI
HEAT
EXCHANGE
(EVAPORATOR)
HEAT
EXCHANGE
(CONDENSER)
COMPRESSOR
ACCUMU
LATOR
GAS SIDE
3-WAY VALVE
LIQUID SIDE
3-WAY VALVE
CAPILLARY TUBE
CHECK VALVE
(Heating Model only)
COOLING
HEATING
REVERSING
VALVE
(Heating Model Only)
(2) Cooling & Heating Models
3. Wiring Diagrams
TS-C2425ML1
Outdoor Unit
TS-C2425DA1
YELLOW
RED
CAPACITOR
H
C
F
BLUE
RED
BLUE
BLUE
C
S
R
YELLOW
OVERLOAD
PROTECT
2(N)
BLUE
/GREEN
BL
U
E
BROWN
BR
O
WN
1(L)
THE UNIT INDOOR
OUTDOOR DIAGRAM WIRING
TERMINAL BLOCK
EBY36312302
FAN
Exploded View
Exploded View
6 Room Air Conditioner
1. Indoor Unit
135313
342800
359011
131410 733010
135316
135311
147581
268711C
146811
346810
W0CZZ
135516
35211B
354210
249951267110
352116
352115
152302
135301
135511
147582-1
147582-2
435301
352150
268711A
354212
W6640
264110
263230
149303
Outdoor Unit
6 Room Air Conditioner
Exploded View
Exploded View
554031
435512
437212
435511
554160
550140
552203-1
552203-2
430410
447910
649950
552111
552112
437210
435301
559010
546810
549610
W0CZZ
430400
W6640
148000
P/NO : MFL58884505