Install Software and Documentation
To configure an In-Sight vision system, In-Sight Explorer software must be installed
on a networked PC. In-Sight software is available as a free download from the In-
Sight support site, or can be purchased separately on a DVD.
Log On to the Vision System
1. Open the In-Sight Explorer software. From the Windows Start menu,
select: All Programs > Cognex > In-Sight > In-Sight Explorer x.x.x > In-Sight
Explorer x.x.x.
2. From the Get Connected Application Step, select your In-Sight vision
system from the Select an In-Sight Sensor or Emulator group box and press
the Connect button.
Vision System Specifications
Specifications In-Sight 8405
Case Temperature
1
0°C to 50°C (32°F to 122°F)
Storage Temperature -20°C to 80°C (-4°F to 176°F)
Humidity < 80% non-condensing
Protection IP30 with cables and lens attached.
Shock (Shipping and
Storage)
IEC 60068-2-27: 18 shocks (3 shocks in each polarity in each (X, Y, Z) axis) 80 Gs (800
M/S
2
at 11 MS, half-sinusoidal)
Vibration (Shipping and
Storage)
IEC 60068-2-6: vibration test in each of the three main axis for 2 hours @ 10 Gs (10 to
500 Hz at 100m/s2 / 15mm)
1
Case temperature can be verified using the EVGetSystemConfig(“Internal.Temperature”)Extended Native Mode command. When
issued, it returnsthe vision system'sinternaltemperature in degreesCelsius,which willbe ±5 degreesabove the vision system case
temperature. Refer to the In-Sight
®
ExplorerHelp file for more information. Additionalcooling measuresare required if the case
temperature cannot be kept below 50°C. Examplesof such measuresinclude: mounting the vision system to a heat sinkusing the M3
mounting screws,reducing the ambient temperature and ensuring there isair flow over the vision system.