2018
ISOR...EC / ...EC K
CONTENTS
Installation, operating and maintenance
instructions
English
1. FOREWORD ............................................................................... 2
2. IMPORTANT INFORMATION .................................................................. 2
3. GENERAL SAFETY INSTRUCTIONS ............................................................. 3
4. ADHERE TO THE FOLLOWING INSTRUCTIONS ................................................... 6
5. PRODUCT INFORMATION .................................................................... 6
6. DELIVERY CONTENTS ....................................................................... 7
7. TECHNICAL DATA ........................................................................... 7
8. DIMENSIONS .............................................................................. 8
9. TRANSPORT AND STORAGE .................................................................. 9
10. ASSEMBLY ................................................................................ 9
11. ELECTRICAL CONNECTION .................................................................. 10
12. COMMISSIONING .......................................................................... 13
13. MAINTENANCE AND CLEANING .............................................................. 14
14. LIFETIME AND DISPOSAL ................................................................... 15
15. TROUBLESHOOTING ....................................................................... 16
e original instructions were created in the German
language.
Information updated
print 27.11.2023
Subject to change
Example configuration shown
Fully insulated fan box
ruck Ventilatoren GmbH
Max-Planck-Str. 5
D-97944 Boxberg-Windischbuch
Tel. +49 7930 9211-300
Fax +49 7930 9211-166
www.ruck.eu
Made in EU
2| ISOR...EC / ...EC K
EN
Installation, operating and maintenance instructions
2. IMPORTANT INFORMATION
1. FOREWORD
Dear customers,
ank you for choosing our device.
Before operating the unit, please read carefully these installation, operating and maintenance instructions. If you have
any questions, please contact: (Contact details see page 1)
e data provided in these installation, operating and maintenance instructions are for the product description only. A
statement about a certain condition or a suitability for a certain application cannot be derived from our information.
e information does not release the user from his own assessments and examinations.
All rights reserved by the manufacturer, even in the event of industrial property rights.
Any disposal such as copying and distribution rights lies with us.
is manual contains important information on the safe and appropriate assembly, transport, commissioning, operation,
maintenance, disassembly and simple troubleshooting of the product.
e product has been manufactured according to the accepted rules of current technology.
ere is, however, still a danger of personal injury or damage to equipment if the following general safety instructions and
the warnings before the steps contained in these instructions are not complied with.
Read these instructions completely and thoroughly before working with the product.
Keep these instructions in a location where they are accessible to all users at all times.
Always include the operating instructions when you pass the product on to third parties.
2.1. Applicable Documents
e following documents and information on the exhaust fan must be observed in addition to the installation, ope-
rating and maintenance instructions:
Other applicable standards:
DIN VDE 0100-100
DIN EN 60204-1
DIN EN ISO 13857
DIN EN ISO 12100
VDMA 24186-1
Available documents at www.ruck.eu
Installation, operating and maintenance instructions
EC Declarations of conformity
EC-Declaration of Incorporation (Directive 2006/42/
EC)
Commissioning report
Call to Tender
Dimensioned drawing
Technical drawing DWG
Technical drawing DXF
3D STEP
Nameplate
3
EN
2.3. Warranty and liability
Our devices are manufactured to the highest technical level in accordance with the generally accepted rules of techno-
logy. ey are subject to constant quality controls. Because the products are being constantly developed, we reserve
the right to make changes to the products at any time and without prior announcement. We assume no liability for the
correctness or completeness of these installation, operating and maintenance instructions.
To ensure your warranty claims, it is imperative to provide a commissioning report and a maintenance record.
Warranty and liability claims for personal injury and property damage are excluded if they are due to one or more of
the following causes:
Improper use
Improper mounting, commissioning, operation and maintenance
Operating the device with defective and / or non-functional safety and protective devices
Failure to observe the instructions regarding transportation, installation, operation and maintenance
Unauthorized structural changes to the device
Poor monitoring and replacement of maintenance parts
Improperly performed repairs
Disasters and force majeure
3. GENERAL SAFETY INSTRUCTIONS
Planners, plant engineers and operators are responsible for ensuring that the product is installed and operated correc-
tly.
Use our devices only in perfect technical condition.
Check the device for obvious defects, such as cracks in the housing or missing rivets, screws, caps or other applica-
tion-relevant defects.
Only use the device in the power range specified in the technical data and on the nameplate.
Protection against contact and being sucked in and safety distances should be provided in accordance with DIN EN
13857.
Generally prescribed electrical and mechanical protection devices are to be provided by the client.
Safety components must not be bypassed or put out of operation.
e product may be operated by personnel with limited physical, sensory or mental capacities only if they are su-
pervised or have been instructed by responsible personnel.
Children must be kept away from the product.
2.2. Provisions and regulations
When properly installed and operated, the device complies with the applicable standards and EU Directive at the
time of its placing on the market.
In addition, observe generally valid, legal and other binding regulations of the European or national legislation as well
as the regulations in your country for accident prevention and environmental protection.
www.ruck.eu |
4| ISOR...EC / ...EC K
EN
Installation, operating and maintenance instructions
3.2. Improper use
Any use of the product other than described in chapter “Intended use” is considered as improper.
e following points are improper and dangerous:
Delivery of explosive and flammable media or operation in potentially explosive atmospheres.
e conveyance of greasy and moist media (over 90% relative humidity).
Delivery of aggressive and abrasive media.
Operation without the duct system.
Operation with closed air connections.
e use on vehicles, aircrafts and ships.
3.3. Personnel qualifications
Assembly, commissioning, operation, disassembly and service (including maintenance and repair) require basic mecha-
nical and electrical knowledge, as well as knowledge of the appropriate technical terms. In order to ensure operating
safety, these activities may therefore only be carried out by qualified technical personnel or a person under the direc-
tion and supervision of qualified personnel. Qualified personnel are those who can recognize possible hazards and
institute the appropriate safety measures due to their professional training, knowledge, and experience, as well as
their understanding of the relevant conditions pertaining to the work to be done. Qualified personnel must observe the
rules relevant to the subject area.
In this manual, there are safety instructions before the steps whenever there is a danger of personal injury or damage
to the equipment. e measures described to avoid these hazards must be observed.
Safety instructions are set out as follows:
Safety sign (warning triangle) - Draws attention to the risk.
Type of risk! - Identifies the type or source of the hazard.
»Consequences - Describes what occurs when the safety instructions are not complied with.
→ Precautions - States how the hazard can be avoided.
3.4. Safety instructions in this manual
3.1. Intended use
Our devices are incomplete machineries as defined in the EU Machinery Directive 2006/42/EC (partly completed ma-
chinery). e product is a not ready-for-use machine in terms of the machine directive.
It is intended exclusively for installation in a machine or in ventilation equipment and installations or for combination
with other components to form a machinery or installation. e product may be commissioned only if it is integrated
in the machinery/system for which it is designed and the machinery/system fully complies with the EC machinery di-
rective.
Observe the operating conditions and performance limits specified in the technical data.
Conveying and ambient temperatures must be observed according to the technical data and the nameplate.
Intended use also implies that you have fully read and understood this manual.
Improper use may result in danger to the life and limb of the user or third parties or damage to the system
or other property.
5
!
!
!
!
!
!
!
!
!
!
!
EN
General warning!
Indicates possible hazardous situations. Failure to observe the warnings may result in perso-
nal injury and / or damage to property.
Electricity warning (hazardous voltage)!
Indicates possible hazards due to electricity. Failure to observe the warnings may result in
death, injury and/or damage to property.
Hot surface warning!
Indicates possible hazards due to high surface temperatures. Failure to observe the warnings
may result in personal injury and/or damage to property.
Finger-Crushing Warning!
Indicates possible hazards due to moving and rotating parts. Failure to observe the warnings
may result in personal injury.
Overhead load warning!
Indicates possible hazards due to overhead loads. Failure to observe the warnings may result
in death, injury and/or damage to property.
Follow important information!
Instructions for safe, optimum use of the product.
Safety sign (warning
triangle)
Consequence
Electricity warning (hazardous voltage)!
»Failure to observe the hazard may result in death,
injury or damage to property.
→ Before performing any work on conductive parts, al-
ways disconnect the unit completely from the electri-
city supply and make sure that it cannot be switched
back on again.
Never reach into the impeller or other rotating or
moving parts.
»Failure to observe the hazard may lead to serious
injury.
→ Work may only be performed once the impeller has
come to a complete halt.
Never clean the internal space with flowing water
or a high-pressure cleaner. Do not use aggressive or
easily flammable products for cleaning (impellers/
housing).
Only use mild soapsuds. e impeller should be cleaned
with a cloth or brush.
General warning
»Failure to observe the warnings may result in personal
injury and / or damage to property.
→ Unauthorized repairs may cause personal injury and /
or damage to property, in which case the manufactu-
rer‘s guarantee or warranty will not apply.
Caution! Burning hazard.
»Failure to observe the hazard may result in personal
injury and/or damage to property.
→ Do not touch the surface until the motor and heater
have cooled.
Never reach into the impeller or other rotating or
moving parts.
»Failure to observe the hazard may lead to serious
injury.
→ Work may only be performed once the impeller has
come to a complete halt.
www.ruck.eu |
6| ISOR...EC / ...EC K
EN
Installation, operating and maintenance instructions
4. ADHERE TO THE FOLLOWING INSTRUCTIONS
4.1. General instructions
Persons who assemble, operate, disassemble or maintain our devices must not be under the influence of alcohol,
drugs or pharmaceuticals that may affect perception and responsiveness.
Responsibilities for the operation, maintenance and regulation of the product should be clearly determined and
observed so that there can be no unclear areas of responsibility with regard to safety.
4.2. Indications assembly
Disconnect all of the product‘s poles from the mains before installing the product or connecting or removing plugs.
Make sure that the product cannot be switched back on again.
Lay cables and lines so that they cannot be damaged and no one can trip over them.
Information signs must not be changed or removed.
4.3. Indications Commissioning
Make sure that all electrical connections are either used or covered. Commission the product only if it is installed
completely.
e power switch must always be fully functional and easy accessible!
Only authorized personnel is allowed to operate the setting mechanisms of the components or parts, under the
provision that the system is used as intended.
In an emergency, or if there is a fault, or other irregularities, switch the equipment off and make sure it cannot be
switched back on again.
e technical data given on the rating plate must not be exceeded.
4.4. Indications during operation
5. PRODUCT INFORMATION
Description:
Fully insulated fan box
e temperature of the conveying medium of the individual types can be found in the technical data
Backward curved radial impeller
Integrated thermal motor monitoring
Indoor installation/ Outdoor installation (with weather protection)
e housing is made of galvanized sheet steel.
EC motor controllable via 0-10V or PWM signal
7
ISOR 125 EC 20 129441 230V ~ 50/60 106 0,9 60 60 59 75 IPX4 130302 11,8
ISOR 125 EC K 01 165180 230V ~ 50/60 118 1,0 50 50 60 77 IPX4 130302 12,3
ISOR 150 EC 20 129448 230V ~ 50/60 103 0,9 60 60 62 75 IPX4 130302 11,9
ISOR 150 EC K 01 165183 230V ~ 50/60 110 1,0 60 60 61 78 IPX4 130302 12,2
ISOR 160 EC 20 129451 230V ~ 50/60 104 0,9 60 60 62 75 IPX4 130302 11,9
ISOR 160 EC K 01 165186 230V ~ 50/60 120 1,0 50 50 61 77 IPX4 130302 12,1
ISOR 200 EC 20 129473 230V ~ 50/60 118 1,0 60 60 60 73 IPX4 130302 17,6
ISOR 200 EC K 01 166124 230V ~ 50/60 97 0,9 60 60 58 71 IPX4 130302 17,8
ISOR 250 EC 20 132590 230V ~ 50/60 204 1,8 70 70 68 81 IPX4 130303 18,9
ISOR 315 EC 20 131803 230V ~ 50/60 274 1,9 55 55 69 80 IPX4 130303 25,0
ISOR 355 EC 20 131810 230V ~ 50/60 165 1,4 60 60 58 66 IPX4 132058 40,4
ISOR 400 EC 20 131813 230V ~ 50/60 165 1,4 60 60 57 66 IPX4 132058 40,0
ISOR 450 EC 20 131816 230V ~ 50/60 507 2,3 50 50 69 75 IPX4 132058 65,3
ISOR 450 EC 21 164501 230V ~ 50/60 1272 5,8 40 40 77 77 IPX4 164530 59,5
ISOR 500 EC 20 132441 230V ~ 50/60 506 2,3 50 50 68 74 IPX4 132058 67,3
EN
5.1. Nameplate
ATTENTION! e information on the nameplate must always be observed!
Legend:
Imax Max. current consumption
tA / tMMax. ambient temperature / Max. medium temperature
P1N Rated power consumption
nNRated speed
ErP Data ErP Conformity, if required according to Reg. 327/2011
η Overall efficiency
N Efficiency at the optimum energy efficiency
ID Item number
SN Serial number
Air direction arrow
ErP 2015
Product name
Test date
CE marking
UKCA marking
6. DELIVERY CONTENTS
1 x Fully insulated fan box
1 x Installation, operating and maintenance instructions
EC Declarations of conformity
EC-Declaration of Incorporation (Directive 2006/42/EC)
Insulation class motor
EAC marking
7. TECHNICAL DATA
Product name
Item number
Voltage UN
Frequency fN
Rated power consumption PN
Max. motor current Imax
Max. ambient temperature tA
Max. medium temperature tM
Sound power inlet
Sound power outlet
IP protection complete device
Wiring diagram
Weight
VHz W A °C °C dB(A) dB(A) kg
Protection class
www.ruck.eu |
8
A B C D E F G H I J K L M
mm mm mm mm mm mm mm mm mm mm mm mm mm
B
E
F
C
A
G
D
I
H
J
M
K
L
| ISOR...EC / ...EC K
129441 NW 125 383 384 451 232 136 119 380 378 402 426 310 378
165180 NW 125 383 384 451 232 136 119 380 378 402 426 310 378
129448 NW 150 383 384 451 232 133 132 380 378 402 426 310 378
165183 NW 150 383 384 451 232 133 132 380 378 402 426 310 378
129451 NW 160 383 384 447 232 133 137 380 378 402 426 310 378
165186 NW 160 383 384 447 232 133 137 380 378 402 426 310 378
129473 NW 200 482 466 533 287 168 165 480 460 484 508 410 478
166124 NW 200 482 466 533 287 168 165 480 460 484 508 410 478
132590 NW 250 482 466 577 287 148 190 480 460 484 508 410 478
131803 NW 315 542 516 617 387 208 216 540 510 534 558 470 538
131810 NW 355 682 656 757 492 273 234 680 650 674 698 610 678
131813 NW 400 682 656 757 492 263 256 680 650 674 698 610 678
131816 NW 450 783 805 946 547 283 276 780 800 823 847 710 778
164501 NW 450 783 805 946 547 283 276 780 800 823 847 710 778
132441 NW 500 783 805 946 587 293 303 780 800 823 847 710 778
ISOR...EC / ...EC K
EN
Installation, operating and maintenance instructions
8. DIMENSIONS
Item number
9
EN
9. TRANSPORT AND STORAGE
Transport and storage should only be performed by specialist personnel in accordance with the assembly and opera-
ting manual and regulations in force.
e following points should be noted and followed:
Check the delivery according to the delivery note to ensure it is complete and correct and check for any damage.
Any missing quantities or damage incurred during transport should be confirmed by the carrier. No liability is accep-
ted if this is not observed.
For weight see technical data
It should be transported with suitable lifting equipment in the original packaging or on the transport equipment
indicated.
If transported with a forklift, it should be ensured that the product is resting with the basic profile or base frame
completely on the forks or on a pallet and the product‘s centre of gravity is between the forks.
e driver must be authorized to drive a forklift.
Do not go beneath the suspended load.
Avoid damage or deformation of the housing.
e product must be stored in a dry area and protected from the weather in the original packaging. Open pallets
should be covered with tarpaulins. Even weatherproof modules should be covered because their weather resistan-
ce is only guaranteed after complete installation. If moisture has penetrated into the original packaging, remove it
immediately.
Storage temperature between +5 °C and +40 °C. Avoid severe temperature fluctuations.
If the product has been in storage for more than a year, check the smooth running of impellers and valves by hand.
10. ASSEMBLY
Assembly work may only be performed by specialist personnel in accordance with the installation and operating ma-
nual and the regulations and standards in force.
e following points should be noted and followed:
Only suitable installation aids, in accordance with regulations, should be used.
e device must be installed in such a way that it is easily accessible for maintenance and cleaning purposes.
e unit should only be installed with authorized and suitable fastening materials at all fastening points.
Do not distort the unit when installing.
Just use the indicated mounting and fixing places. No holes should be made in the housing or any screws screwed
into it.
e duct system must not be supported on the housing.
For structure-borne sound decoupling, a flexible connection is recommended when connected on a duct system.
At least 2.5 times the diameter of the tube straight duct length before and after the fan
www.ruck.eu |
10
00
H2
E
D2
G
D1
H1
F
A
B
C
| ISOR...EC / ...EC K
EN
Installation, operating and maintenance instructions
e electrical installation may only be carried out by qualified electricians in compliance with the installation, operating
and maintenance instructions and the applicable national regulations, standards and guidelines:
ISO, DIN, EN and VDE specifications, including all safety requirements.
Technical connection conditions.
Safety at work and accident prevention requirements.
is list does not claim to be complete.
Requirements should be applied under one‘s own personal responsibility.
11. ELECTRICAL CONNECTION
Electricity warning (hazardous voltage)!
»Failure to observe the hazard may result in death, injury or damage to property.
→ Before performing any work on conductive parts, always disconnect the unit completely from the electri-
city supply and make sure that it cannot be switched back on again.
10.1. Assembly with accessories
ASG Protection grille
BFV Filter box with mat filter
CVM Fast clamps
D1
D2
SDS
SDF
Tube silencer rigid
Tube silencer flexible
EGS 03 Device switch
FRD ISOR Rain cover
GRSK
RSK-D
Back draught shutter
Back draught shutter with seal
H1
H2
FTW
FT
Filter box for bag filter and heating
Filter box for bag filter
11
EN
11.1. Unit supply cable / Electrical connection / wiring diagram
Connect the mains supply cable as shown in the wiring diagram. For the dimensioning of the line, observe the unit‘s
rating plate and the relevant guidelines. Appropriate protection with correctly dimensioned automatic safety breakers
(circuit protection breaker) must be provided.
e device must be connected according to the wiring diagram. For fans which are controlled by external control de-
vices, the corresponding operating instructions of the manufacturer must be observed.
e electrical connections must be made as shown in the corresponding wiring diagrams and terminal diagrams.
e type of cable, size of cable and method of laying should be determined by an authorized electrician.
Low and extra-low voltage cables should be laid separately.
If no repair switch is integrated in the device, an all-pole mains disconnecting switch with min. 3 mm contact
opening must be provided in the supply line.
Use a separate cable inlet for each cable.
Any cable inlets that are not used must be sealed so that it is airtight.
All cable inlets must have strain relief.
Create equipotential bonding between the unit and the duct system.
Check all protective measures after the electrical connection work (earthing resistance, etc.)
Motor current and motor power must not exceed the values stated on the motor nameplate. e specified max.
fan speed must never be exceeded, otherwise the motor and fan will be destroyed by this overload and dissolved
or flying parts can destroy other components.
www.ruck.eu |
12
Bl.
Blatt
Ursp.
Norm
Gepr.
Bearb.
Datum
Name
Datum
Änderung
Zustand
ruck Ventilatoren GmbH
Max-Planck-Str. 5
D-97944 Boxberg
Tel +49 (0) 7930 9211-300
EC_ansteuerung
Applikation
EC-Motor
10.08.2020
S.Kuhbach
5
E
D
C
B
F
A
E
D
C
B
F
A
8765
4
3
2
1
MTP20
S1 S2
+
U+
MTP30
10VDC
+
+
V Out
0-10V
GND
SPS, DDC,
external control unit...
Keine Drehzahl Regelung
100% Leistung
Anschluss Potentiometer
MTP20
Anschluss Potentiometer
MTP30
Anschluss 0-10V Signal
Motor Starts @ 1,5V
161895
ECM
gnye
bn
bu
ye
or
bk
wh
PE
L
N
GND
0-10V
+10V
Speed+
ECM
gnye
bn
bu
ye
or
bk
wh
PE
L
N
GND
0-10V
+10V
Speed+
ECM
gnye
bn
bu
ye
or
bk
wh
PE
L
N
GND
0-10V
+10V
Speed+
ECM
gnye
bn
bu
ye
or
bk
wh
PE
L
N
GND
0-10V
+10V
Speed+
| ISOR...EC / ...EC K
ISOR 450 EC 21
EN
Installation, operating and maintenance instructions
Connection potentiometer
MTP30
No speed control
100% Power
Connection 0-10V signal
Evaluation Speed +
Connection potentiometer
MTP20
Connection PWM signal
11.1.1. Application examples
e following circuits are not possible for:
13
Bl.
Blatt
Ursp.
Norm
Gepr.
Bearb.
Datum
Name
Datum
Änderung
Zustand
ruck Ventilatoren GmbH
Max-Planck-Str. 5
D-97944 Boxberg
Tel +49 (0) 7930 9211-300
EC_ansteuerung_ZA
Applikation
EC-Motor
07.12.2022
PK
7
E
D
C
B
F
A
E
D
C
B
F
A
8765
4
3
2
1
MTP20
S1 S2
+
U+
MTP30
10VDC
+
+
V Out
0-10V
GND
SPS, DDC,
external control unit...
Keine Drehzahl Regelung
100% Leistung
Anschluss Potentiometer
MTP20
Anschluss Potentiometer
MTP30
Anschluss 0-10V Signal
Motor Starts @ 1,5V
166007
4 5 6
L1
N
PE
GND
DC Out +10V
D1 Digital In (Enable)
DC Out +24V
NC
COM
NO
Fault
Relay
E1 Analog In 0-10V
Enable
4 5 6
L1
N
PE
GND
DC Out +10V
D1 Digital In (Enable)
DC Out +24V
NC
COM
NO
Fault
Relay
E1 Analog In 0-10V
4 5 6
L1
N
PE
GND
DC Out +10V
D1 Digital In (Enable)
DC Out +24V
NC
COM
NO
Fault
Relay
E1 Analog In 0-10V
Enable
4 5 6
L1
N
PE
GND
DC Out +10V
D1 Digital In (Enable)
DC Out +24V
NC
COM
NO
Fault
Relay
E1 Analog In 0-10V
EnableEnable
ISOR 450 EC 21ISOR 450 EC 21
EN
Connection potentiometer
MTP30
No speed control
100% Power
Connection 0-10V signalConnection potentiometer
MTP20
12. COMMISSIONING
Commissioning by trained technical personnel may only be performed after any risk has been ruled out. e
following checks should be performed in accordance with the installation and operating manual and the regu-
lations in force:
Correctly sealed installation of the unit and duct system.
Check the duct system, unit and medium lines, if present, remove any foreign bodies if necessary.
e intake opening and inflow into the unit must be clear.
Check all mechanical and electrical protection measures (e.g. earthing).
Voltage, frequency and type of current must correspond with the rating plate.
11.2. ermal motor protection
During operation, electric motors heat up. Under certain circumstances (excessively high ambient or fluid temperatu-
res, heavy contamination, etc.), the motor temperature may exceed the safety limit of the electrically isolated parts.
In case of EC motors an electronic temperature monitoring is present.
If a fault current protection switch is used, only AC/DC sensitive RCD protective devices (type B or B+) are permitted.
11.3. Fault current protection switch
Even when the device is switched off, voltage is applied to terminals and connections. Do not touch the device
for 5 minutes after all-pole disconnection from the mains.
www.ruck.eu |
14 | ISOR...EC / ...EC K
EN
Installation, operating and maintenance instructions
Servicing, troubleshooting and cleaning may only be performed by specialised personnel in accordance
with this installation and operating manual and the regulations in force.
Make sure that no connections or components are loosened unless the device is disconnected from
the mains. Make sure that the equipment cannot be switched back on again.
Individual components must not be interchanged. For example, the components intended for one pro-
duct may not be used for other products.
e regular maintenance and care of our devices is designed to ensure proper function, value retention
and avoidance of damage. Keep a maintenance log.
Perform the specified maintenance on the unit at the specified intervals.
13. MAINTENANCE AND CLEANING
Our devices require little maintenance when operated properly.
e following work should be performed at regular intervals, in accordance with health and safety regulations:
Check the operation of the control system and safety devices.
Check electrical connections and wiring for damage.
Remove any dirt from the fan impeller or impellers and from inside the fan housing in order to prevent any unba-
lance or reduction in output.
Do not use aggressive or easily flammable products for cleaning (impellers/housing).
Preferably only water (not flowing water) or mild soapsuds should be used.
e impeller should be cleaned with a cloth or brush.
Never use a high-pressure cleaner.
Balancing clips must not be moved or removed.
e impeller and fittings must not be damaged in any way.
Before putting the unit back into operation after maintenance and servicing work, carry out a visual inspection as
described in section 11. and 12.
15
EN
14. LIFETIME AND DISPOSAL
14.1. Product life
e motors are equipped with maintenance-free, permanently lubricated ball bearings. Under normal operating condi-
tions, the expected lifetime is about 30,000 operating hours.
e information given here depends strongly on the respective field of application as well as the environmental condi-
tions. We recommend replacing these fans after reaching about 30,000 operating hours or 5 years.
14.2. Decommissioning and disposal
When disassembling, parts under voltage are exposed, which can lead to electric shock when touched.
Before dismantling, disconnect the fan from all poles of the mains and secure against being switched
on again!
Parts and components of the device that have reached their lifetime, e.g. due to wear, corrosion, mechanical stress,
fatigue and/or all other, not directly recognizable effects, must be disposed of professionally and properly after disas-
sembly in accordance with national and international laws and regulations. e same applies to excipients in use such
as oils and fats or other substances. e conscious or unconscious reuse of used components such as e.g. impellers,
rolling bearings, motors. etc. can lead to a risk to persons, the environment as well as machinery and equipment. e
applicable local operating regulations must be observed and applied.
13.1. Checklist Maintenance and Service
Description check interval
Triggering device monthly
Fan
Check fan for function and operational readiness (test run at least 15 minutes) every 6 months
Check fan for function and operational readiness (test run at least 1 hour) yearly
Check for dirt, damage, corrosion and fastening every 6 months
Function-preserving cleaning every 6 months
Check impeller rotation direction yearly
Check flexible connections for leaks yearly
Check impeller for imbalance yearly
Check protective device for function yearly
Motor
Check externally for dirt, damage, corrosion and fastening every 6 months
Function-preserving cleaning yearly
Check bearing for noise yearly
Check terminals for tight fit yearly
Measure the voltage yearly
www.ruck.eu |
16 | ISOR...EC / ...EC K
EN
Installation, operating and maintenance instructions
14.3. Spare parts (motor + impeller)
Only original spare parts may be used. e repair may only be carried out by personnel trained and authorized.
Fault Possible cause Remedy methods
Fan does not start No power supply Check mains supply / connections
Impeller does not rotate freely Find out the causes and, if possible, remove
the fault. If not possible, contact the sup-
plier.
Motor overheated
/ temperature pro-
tection is tiggered
Fault of the ball bearings Contact the supplier
Too high operating temperature Observe the data on the nameplate
Air flow is too low, motor cannot cool
down
See fault „Low air flow“
Device too noisy /
casing vibrations
Dirt deposits on the impeller See chapter maintenance and cleaning
Imbalance of the impeller Contact the supplier
Connection with intake or exhaust pipe /
duct causes vibrations / oscillations
Install fan with vibration dampers
Fixing screws released Tighten screws
Fault of the ball bearings Contact the supplier
Loose impeller blade Contact the supplier
Low airflow Impeller runs in the wrong direction (wrong
air transport direction)
Note the marking on the device / namepla-
te. Check electrical connections
High pressure losses in the system Improve piping configuration or select a
more powerful fan
Return flaps closed or only partially open Check drive system / installation position of
the return flap
Duct system clogged Remove blockage / clean protective grille
Speed control incorrectly set / incorrectly
connected
Check settings / switching unit and possibly
adjust / connect
15. TROUBLESHOOTING
If the fan stops due to a malfunction, please disconnect all poles of the fan from the power supply.
Please then check whether there is an obvious fault (blocked impeller, damage, etc.) and rectify it. If there are no obvi-
ous faults, you can reconnect the fan to the mains after waiting for approx. 1 minute.
If there is still no function, please proceed according to the following table:
Information updated
print 27.11.2023
mrirvec_pb_20_k10001_en
We reserve the right to make changes
Language:
English
ruck Ventilatoren GmbH
Max-Planck-Str. 5
D-97944 Boxberg-Windischbuch
Tel. +49 7930 9211-300
Fax +49 7930 9211-166
www.ruck.eu
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI