Eurolux F75DWSC Owner's manual

Type
Owner's manual

This manual is also suitable for

3 Blade Darkwood Fans
MODEL
MODEL
F75DWSC / F78DW
PRODUCT CODE
Cape Town - 9 Racecourse Road, Milnerton, 7441
Johannesburg - 10 Milkyway Avenue, Linbro Business Park, Sandton, 2065
www.eurolux.co.za
Please read instructions before commencing installation and retain for
future reference.
F75DWSC
F78DW
Twister 3 Blade Fan
MODEL
MODEL
F75DWSC/F78DW
MODEL TT52-BC-N3ABS/TT52-MB-N3ABS
PRODUCT CODE
MODEL
Cape Town - 9 Racecourse Road, Milnerton, 7441
Johannesburg - 10 Milkyway Avenue, Linbro Business Park, Sandton, 2065
www.eurolux.co.za
Please read instructions before commencing installation and retain for
future reference.
Description Of Parts:
1. Mounting bracket
2. Screw
3. Screw
4. Hanger ball
5. Upper Canopy
6. Downrod
7. Cross pin
8. Screw
9. Cotter pin
10. Downrod Yoke
11. Upper housing
12. Driver
13. DC motor
14. Blade
15. Screw
16. Decorative plate
17. Remote control receiver
18. Male and female plug/quick connector
19. Male and female plug/quick connector
20. Male and female plug/quick connector
21. Remote control
ILLUSTRATION
Waste electrical & Electronic equipment regulations requires that any of our products
showing this marking must not be disposed of with other household or commercial
waste. To prevent possible harm to the environment or human health from uncontrolled
waste disposal, please separate any such products from other waste types and
recycle it responsibly at your local facilities.
ENVIRONMENTAL PROTECTION
CAUTION: Ensure power supply is turned off before attempting trouble shooting.
NOTE: This fan does not contain servicable parts. DO NOT OPEN or TAMPER WITH THE MOTOR.
Should your fan not start:
1) Check fuses are in place in the switchboard.
2) Recheck the terminal strip connections.
3) Ensure the wall & direction switches are not stuck in a “middle” position.
4) Ensure that the shipping tabs have been removed.
5) Ensure that the speed controller is not in the incorrect position.
Should your fan be noisy:
1) Checkallscrewsaresufcientlytight:fanbladesandfanholders,(ifapplicable)glassofthe
lamp holder.
2) Allow at least 24 hours for the fan to settle.
Should your fan wobble:
In general, wobble is caused by the blades not cutting the air at the same point. Measure downwards
from the ceiling and make sure each blade is at the same height to the ceiling. See Figure 1. If they are
not, adjust by hand by slightly bending the blade and bracket. If a major adjustment is needed, insert a
washer as shown in Figure 2.
1) Check the blades are securely fastened to the holders.
2) Check the blade holders are tight on the motor.
3) Ensure the mounting bracket is properly screwed to the ceiling.
4) Interchange opposite blade sets if needed.
Fitting material: Pressed steel & ABS
Lamp: F75DWSC/F78DW:N/A
Dimensions: F75DWSC/F78DW:(H)335mmx(Ø)1330mm
Motor: DC 28W
Voltage:220V-240V~50Hz
Protection against electric shock: Class 1. Requires earth connection.
IP:20.Protectedagainstsolidforeignobjectsof12.5mmØandgreater,notprotectedagainstwater.
• Not for outdoor use or in wet conditions and areas of high humidity.
Features: 5 Speeds forward and reverse.
  Remotecompatible(Remoteincluded).
• 2 year warranty
SPECIFICATIONS
F75DWSC / F78DW-attachments:
Iftheexternalexiblecableorcordofthisfanisdamaged,itshouldbeexclusivelyreplacedbythe
manufacturerorhisserviceagentorasimilarqualiedpersoninordertoavoidahazard.Toensurethat
you get maximum longevity and maximum use out of your fan, please observe the following
safety instructions.
Electrical products can cause death, injury, or damage to property.
 Installationofthefanmustbecarriedoutbyaqualiedelectrician,inaccordancewithSANS10142.
 Oncompletionofinstallation,ensurethattheCerticateofComplianceisupdated.
Before connecting this fan, ensure that voltage indicated on the rating label corresponds with the mains
voltage in your home.
When cleaning, ensure that the power is turned off.
This fan is checked in full for conformity to the quality standards and safety requirements.
The manufacturer / supplier is not responsible for any damage of properties and persons, caused by
the incorrect use or installation of the fan.
Should you be unsure of how to install this fan correctly, please consult a professional electrician or
your supplier for assistance.
Ensure all items / components, threads and screws are tightly secured.
IMPORTANT:
Tampering with this fan, i.e.using silicon sealers or incorrect cabling, will invalidate your warranty.
Please check whether the connection of the power cord is safe and reliable before installation.
Always ensure that the mains supply voltage is correct.
Do not use the fan outdoors, in wet conditions or areas of high humidity.
• Thisapplianceisnotintendedforusebyyoungchildrenorinrmpersonsunlesstheyhavebeen
adequately supervised by a responsible person.
IMPORTANT SAFEGUARDS
TROUBLESHOOTING:
Touching
Ceiling
Figure 1
Fan Wobbles:
CLEANING
Before cleaning always ensure the power supply is turned off and that the fan has been unplugged.
Do not immerse the fan in water.
No abrasive products, solvents, detergent may be used to clean this fan.
Ensure that the fan does not come in contact with corrosive chemicals, etc.
Remove the blades and wipe down parts with a damp cloth to remove any dust.
Ensure all parts are dry before reassembling your fan.
The motor bearings are permanently sealed and do not require additional lubrication.
OPERATION INSTALLATION
Secure the Mounting bracket to the ceiling
joist with the two long fixing screws provided Loosing the cross pin and cotter pin from the
downrod. Loosing the screw from the hanger ball
Insert the upper canopy to the downrod
Insert the cross pin and lock the hanger ball
and downrod screw.
Insert the downrod to yoke and then insert the
cross pin and cotter pin to tight the yoke screw
to fix the downrod
Wire the incoming power cables to the terminal
block mounted on the Mounting bracket. Wire
Neutral, Earth, Active to the corresponding N,L,
terminals respectively.
Slide the remote control receiver inside the
Mounting bracket and carefully position all
excess cable inside upper canopy
7 8 9
4 5 6
1 2 3
Insert the hanger ball to downrod
INSTALLATION
The remote receiver has been pre-wired to the
Mounting bracket Do not remove. Connect
the quick-connectors between the remote
control receiver and the motor (see above image)
Slide the canopy up to cover the ball joint, wiring,
receiver and hanging bracket, then secure in
place Loosing the screw from the motor
ht woN. etalp evitaroced eht llatsnI rotom ot edalb eht llatsnI e fan have completed
13 14 15
10 11 12
INSTALLATION
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Eurolux F75DWSC Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI