39126-0-0618Page 6
1. SelectthecorrectOrice(B)foryourapplicationfrom
Table 2and,usinga3/8"wrench,installitintothe
OriceFittingElbow(A)retainedfromthedisassembly
sequence.DONOTuseanincorrectorice.
2. InstalltheOriceFittingElboww/Oricebackintothe
VenturiAirShutter,pointingrearwards.
3. Attachtheassemblyofitems(K),(F),(L),and(G)tothe
ManualValve(J),orientedasshowninFigure 3. Use pipe
dopeonthreadedconnections.OMITTHEREGULATOR
(L)andoneNipple(F)ifthisisanLPburner.
4. Usinga9/16"wrench,attachtheManualTubeAssembly
(C)totheManualValve(J)asshowninFigure 3.
5. FeedtheTubeAssemblythroughthefront-mosthole
intheburnerlegasshowninFigure 4.
6. AttachtheValveBracket(I)totheburnerlegusinga
5/16"hexdriverandtwo#10x1/2"Screws(E).
7. AttachoppositeendofTubeAssembly(C)tothe
OriceFittingElbow(A)usinga9/16”wrench.
8. Usinga1/4"hexdriverandtwo#8x3/8"Screws(D),
attachthePilot(M)totheburnerbaseasshownin
Figure 3.
9. AttachthePilotLinetotheValveusinga3/8"wrench,
andtheThermocoupleLinetothevalveusinga5/16"
wrench,asshowninFigure 4.
10. NeatlyarrangethePilotandThermocoupleLines
behind the burner.
11. Attachlightinginstructionplatetorearholeinburner
legusingincludedlengthofchain.
12. Returnburnerassemblytoreplace.
13. ConnectgaslinetoBrassFlareElbow(G).
14. Compoundsusedonthreadedjointsofgaspiping
shallberesistanttotheactionofliqueedpetroleum
gases.Thegaslinesmustbecheckedforleaksbythe
installer.Testingforleaksonallexposedconnections
shouldbedonewithleaktestsolutionorasoap
solution.Aftertestingiscomplete,allsolutionshould
becleanedoff.Onunexposedconnections,apressure
testshouldbemade.Neveruseanexposedflameto
checkforleaks.Burnermustbedisconnectedfrom
pipingatinletofcontrolvalveandpipecappedor
pluggedforpressuretest.Neverpressuretestwith
replaceconnected;controlvalvewillsustaindamage!
15. Replacerockwoolonburnersurface.Seeburner
InstallationManualformoreinformation.
16. ReinstallFiberHeatSink
17. Reinstalllogsaccordingtologinstructionmanual.
18. Installationiscomplete.
REFERENCE FIGURES 3, 4, AND TABLE 2, DURING THE FOLLOWING ASSEMBLY STEPS: