Broan C3 Coil Drip Guard Kit Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Broan C3 Coil Drip Guard Kit Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Installation Instructions
C3 Coil Drip Guard Kit
St. Louis, MO
7074990
Specifications and illustrations subject to change
without notice and without incurring obligations.
Printed in U.S.A. (05/96)
Figure 1
Figure 2
Drip
Guard
(formed
metal)
Drip
Guard
(hidden
in this
view)
Disconnect all power to the furnace before
servicing coil.
1. On electric furnaces it will be necessary to remove
the blower assembly to gain access to the inside of
the coil. In gas furnaces, the coil will have to be
removed from the furnace cavity. Recover the
refrigerant from the system according to guidlines
outlined under the Refrigerant Transition and
Recovery Certification Program.
2. Locate two of the bent drip guards (see Figure 1).
2. Insert the part between the drain pan’s inside lip
and the coil surface. The longer edge (1-1/4")
should be installed inside the pan. It will be easier
to start the guard by tipping on end toward a
corner.
3. Repeat the process for the other side.
4. Locate two flat drip guards. (Not required on 024
and 030 2 row models)
5. Install one guard between the fins and the drain
pan on the outside edges of the coil (see Figure
2). It may be necessary to wipe the fins over in
order to get the required clearance to slip the guard
in place. The guard itself may be used by pulling it
along the coil between the fin stock and the drain
pan.
6. If the coil was removed from service, reinstall it and
charge according to the installaion instructions
included with the coil and the outdoor unit.
Drip Guard
(flat metal)
/