October 2006
®
Front View
Back View
PRIMERGY BX620 S2 / BX620 S3
PRIMERGY BX620 S2
View
PRIMERGY BX600 S2 Blade Server System Unit
Expansion Board slot
CPU
DIMM Slot
Hard Disk Bay
PRIMERGY BX620 S2
Switch Blade (optional) /
GbE Pass-Thru Blade (optional)
FC Switch Blade (optional) /
FC Pass-Thru Blade (optional) /
Switch Blade (optional) /
GbE Pass-Thru Blade (optional)
Keyboard / Mouse /
Display
Power Supply (optional)
Power Su
pp
l
y
Management Blade
Mana
g
ement LAN
Mana
g
ement Console Board
PRIMERGY BX620 S3
View
Expansion Board slot
DIMM Slot
CPU
Hard Disk Bay
PRIMERGY BX620 S3
This document contains basic product and configuration information that will enable you
to configure your system.
Only these tools will ensure a fast and proper configuration of your PRIMERGY server
or your complete PRIMERGY Rack system.
You can configure your individual PRIMERGY server in order to meet your specific
requirements.
Please follow the lines. If there is a junction, you can choose which way or component
you would like to take.
Go through the configurator by following the lines from the top to the bottom.
The color of the junction means as follows.
Key to
Or
A
n
d
Instruction
PRIMERGY BX620 S2 / BX620 S3
Dual-Processor Blade Server
Base Unit Xeon® 3EGHz/2MB, 1GB
PGUX6221A
CPU Frequencies 64-bit Intel® Xeon® 3.80GHz *5 / 3.40EGHz *6 / 3.20EGHz *7 / 3EGHz
Second-Level-Cache 2MB
Multi-Processor max. 2 (1 for standard)
Front-Side-Bus 800MHz
Chipset Intel® E7520
Memory Standard 1GB (512MB ECC DDR2 SDRAM DIMM x 2) (SDDC(Single Device Data Correction) supported)
Maximum *1 12GB (2GB ECC DDR2 SDRAM DIMM x 6)
Graphics Controller ATI RADEON 7000M , VRAM : 16MB (PCI)
Resolution *2 640x480/800x600/1024x768/1280x1024 dot
Internal Bays Number of bays 2
3.5 inch Available HDD *3 73.4GB (PG-HDH71K) 10krpm, U320 SCSI
HDD 146.8GB (PG-HDH41K) 10krpm, U320 SCSI
300.0GB (PG-HDH31K) 10krpm, U320 SCSI
73.4GB (PG-HDH75K) 15krpm, U320 SCSI
146.8GB (PG-HDH45V) 15krpm, U320 SCSI
Standard -
Maximum *3 600.0GB
PCI Slots PCI-X (64bit/133MHz) [3.3V] optional
( 1 by applying Expansion Card Slot Module
* internal 3.5 inch Bay x 1 is occupied )
RAID Controller Onboard
SCSI Controller Onboard, Ultra320 SCSI x 1ch (with RAID1 function)
LAN Interfaces 2ports (1Gbps) ( 4ports (1Gbps) when 1Gbit/s Ethernet I/O Module (PG-LND101) (2ports(1Gbps)) is applied. ) *8
Fibre channel Interfaces optional ( 2ports (2Gbps) when 2Gbit/s FC I/O Module (PG-FCD102) (2ports(2Gbps)) is applied. ) *9
Interfaces Display (Analog RGB), USB x2(ver. 2.0), Display *10, Keyboard *10, Mouse *10
Server Management Software ServerView (standard) *11
 
Power supply Voltage DC12V / DC5V-Standby (provided by BX600 S2 Blade Server System Unit)
Power consumption 330W / 1188kJ/h (max.)
Dimensions (W x D x H (mm) ) 42 x 476 x 286 ( Server blade slot of BX600 S2 Blade Server System Unit x 1)
 
Weight 7.0kg (max.)
Environmental Conditions Temperature10-35°C / Humidity 20-80% (non condensing)
OS Support *4 Windows Server
TM
2003 R2, Standard Edition / Windows Server
TM
2003 R2, Enterprise Edition
Windows Server
TM
2003, Standard Edition / Windows Server
TM
2003, Enterprise Edition
Windows Server
TM
2003 R2, Standard x64 Edition / Windows Server
TM
2003 R2, Enterprise x64 Edition
Windows Server
TM
2003, Standard x64 Edition / Windows Server
TM
2003, Enterprise x64 Edition
Windows® 2000 Server (SP4) / Windows® 2000 Advanced Server (SP4)
Red Hat Enterprise Linux AS (v.3 for x86) / Red Hat Enterprise Linux ES (v.3 for x86)
Red Hat Enterprise Linux AS (v.4 for x86) / Red Hat Enterprise Linux ES (v.4 for x86)
Red Hat Enterprise Linux ES (v.4 for EM64T)
Attached tool (Standard) ServerStart (Setup Support tool) *12
*1.Available memory capacity will be changed by the type of OS. Please find more details in Notes[Memory OS Compatibility List].
*2. Resolution is determined by functions of the display monitor and OS.
*3. HDD capacity is calculated according to the formula 1GB=1000
3
byte
*4. Drivers for Linux are not attached. Please download and use drivers of the following URL.
http://www.fujitsu.com/global/services/computing/server/ia/driver/
*5. CPU Conversion kit: Xeon(3.0GHz/2MB) -> Xeon(3.8GHz/2MB)(PGBFU36D) is available for upgrading
to Intel® Xeon
TM
3.80GHz.
*6. CPU Conversion kit: Xeon(3.0GHz/2MB) -> Xeon(3.4GHz/2MB)(PGBFU36C) is available for upgrading
to Intel® Xeon® 3.40EGHz.
*7. CPU Conversion kit: Xeon(3.0GHz/2MB) -> Xeon(3.2GHz/2MB)(PGBFU263) is available for upgrading
to Intel® Xeon® 3.20EGHz.
*8. 1Gbit/s Ethernet I/O Module (PG-LND101) is available when Switch Blade (PG-SW104/PG-SW105) or GbE Pass-Thru Blade (PG-LNB101)
are mounted on Network Blade Slot 3,4 of BX600 S2 Blade Server System Unit (PGUR3SC1).
BX620 S2 / BX620 S3 with 1Gbit/s Ethernet I/O Module (PG-LND101) and BX620 S2 / BX620 S3 with 2Gbit/s FC I/O Module (PG-FCD102)
are not allowed to be mounted together on same BX600 S2 Blade Server System Unit (PGUR3SC1).
*9. 2Gbit/s FC I/O Module (PG-FCD102) is available when FC Switch Blade (PG-FCS102) or FC Pass-Thru Blade (PG-FCB101)
are mounted on Network Blade Slot 3,4 of BX600 S2 Blade Server System Unit (PGUR3SC1).
BX620 S2 / BX620 S3 with 1Gbit/s Ethernet I/O Module (PG-LND101) and BX620 S2 / BX620 S3 with 2Gbit/s FC I/O Module (PG-FCD102)
are not allowed to be mounted together on same BX600 S2 Blade Server System Unit (PGUR3SC1).
*10. These are connected to KVM Module (standard) or KVM module (PG-KVB101) (optional) in BX600 S2 Blade Server System Unit (PGUR3SC1).
*11. If you use Windows Server
TM
2003 R2 / Windows Server
TM
2003 R2 x64 Editions, please download and use ServerView of the following URL.
http://www.fujitsu.com/global/services/computing/server/ia/driver/
*12. ServerStart doesn't support Linux.
Type
PRIMERGY BX620 S2
Data Sheet
PRIMERGY BX620 S2 / BX620 S3
*1. When 2Gbit/s FC I/O Module (PG-FCD102) is mounted on Expansion Board Slot of BX620 S2, FC Switch Blade (PG-FCS102) or FC Pass-Thru Blade (PG-FCB101)
is required to be mounted on Network Blade Slot 3,4 of BX600 S2 Blade Server System Unit (PGUR3SC1).
BX620 S2 / BX620 S3 with 1Gbit/s Ethernet I/O Module (PG-LND101) and BX620 S2 / BX620 S3 with 2Gbit/s FC I/O Module (PG-FCD102)
are not allowed to be mounted together on same BX600 S2 Blade Server System Unit (PGUR3SC1).
*2. When 1Gbit/s Ethernet I/O Module (PG-LND101) is mounted on Expansion Board Slot of BX620 S2, Switch Blade (PG-SW104/PG-SW105) or GbE Pass-Thru Blade (PG-LNB101)
is required to be mounted on Network Blade Slot 3,4 of BX600 S2 Blade Server System Unit (PGUR3SC1).
BX620 S2 / BX620 S3 with 1Gbit/s Ethernet I/O Module (PG-LND101) and BX620 S2 / BX620 S3 with 2Gbit/s FC I/O Module (PG-FCD102)
are not allowed to be mounted together on same BX600 S2 Blade Server System Unit (PGUR3SC1).
*3. When Expansion Card Slot Module (PG-CS102) is mounted, HDD can not be mouted on 3.5 inch HDD Bay 2.
*Components installed as standard configuration marked in grey.
Eth. Ctrl 2x1000-BASE-T Cu PG-1862
PCI-X/64bit
SCSI Ctrl U160 PG-128
PCI/64bit
For PRIMERGY SX10
*. PCI card (Eth. Ctrl 2x1000-BASE-T Cu(PG-1862),SCSI Ctrl U160(PG-128)) should be mounted on Expansion Card Slot Module(PG-CS102).
The slot of mounted PCI card is at front side of BX600 S2 Blade Server System Unit (PGUR3SC1).
The cable connected to PCI card can be gone from front side to back side of BX600 S2 Blade Server System Unit (PGUR3SC1)
by using Front-Rear Cable-Thru kit (PG-R1CM1).
Front-Rear Cable-Thru kit (PG-R1CM1) is mounted just under BX620 S2 and occupies 1U.
Max: 2 CPU Processor Xeon 3.8GHz/2MB
PG-FG36D
Standard: 1 CPU PGBFG36D (for CTO)
*. This option is available when CPU Conversion Kit:
Xeon(3.0GHz/2MB) -> Xeon(3.8GHz/2MB) (PGBFU36D) is applied.
Processor Xeon 3.4GHz/2MB
PG-FG36C
PGBFG36C (for CTO)
*. This option is available when CPU Conversion Kit:
Xeon(3.0GHz/2MB) -> Xeon(3.4GHz/2MB) (PGBFU36C) is applied.
Processor Xeon 3.2GHz/2MB
PG-FG263
PGBFG263 (for CTO)
*. This option is available when CPU Conversion Kit:
Xeon(3.0GHz/2MB) -> Xeon(3.2GHz/2MB) (PGBFU263) is applied.
Processor Xeon 3.0GHz/2MB
PG-FG262
PGBFG262 (for CTO)
*. This option is available when the processor of the base unit
is Processor Xeon 3.0GHz/2MB.
*CPU Conversion Kit (available only for a Configure to Order (CTO) option; no separate shipment is possible)
CPU Conversion Kit: 64-bit Intel® Xeon® 3EGHz -> 64-bit Intel® Xeon® 3.80GHz
Xeon (3.0GHz/2MB) Convert the CPU installed as standard in the base unit to the other.
-> Xeon(3.8GHz/2MB) (Note: This option can be ordered only as coupled with the base unit.
(for CTO) A separate shipment is not possible.)
CPU Conversion Kit: 64-bit Intel® Xeon® 3EGHz -> 64-bit Intel® Xeon® 3.40EGHz
Xeon (3.0GHz/2MB) Convert the CPU installed as standard in the base unit to the other.
-> Xeon(3.4GHz/2MB) (Note: This option can be ordered only as coupled with the base unit.
(for CTO) A separate shipment is not possible.)
CPU Conversion Kit: 64-bit Intel® Xeon® 3EGHz -> 64-bit Intel® Xeon® 3.20EGHz
Xeon (3.0GHz/2MB) Convert the CPU installed as standard in the base unit to the other.
-> Xeon(3.2GHz/2MB) (Note: This option can be ordered only as coupled with the base unit.
(for CTO) A separate shipment is not possible.)
Bus
Type Product ID
PGBFU36D
PGBFU36C
PGBFU263
Remarks
1
1
1
Max No.
of Mount
Mountable Cards
PRIMERGY BX620 S2
Configuration Diagram
Expansion Board Slot *1,*2
Memory
DIMM Slot 1
DIMM Slot 2
DIMM Slot 3
DIMM Slot 4
DIMM Slot 5
DIMM Slot 6
CPU
Xeon®
3.80/3.40E/
3.20E/3EGHz
(2MB)
Xeon®
3.80/3.40E/
3.20E/3EGHz
(2MB)
3.5 inch HDD Bay 1
(hot plug)
3.5 inch HDD Bay 2
(hot plug) *3
Hard Disk 3.5inch Bay (hot plug)
Standard Drive Ca
g
e
(
HDD x 1ch
)
Bay 2
SCSI
Mountable I/O Options
Connection Table
CPU
CPU Slot
PRIMERGY BX620 S2 / BX620 S3
BX620 S2 ( In case that Expansion Card Slot Module (PG-CS102) is applied. )
Bay 1
SCSI
Max: 12GB (2GB DIMM x 6) Memory Module-1GB (512MB DIMM x 2)
PG-RM1BC
Standard Memory Module: 1GB (512MB DIMM x 2)
Memory Module-2GB (1GB DIMM x 2)
PG-RM2BC
Memory Module-4GB (2GB DIMM x 2)
PG-RM4BC
Memory Module Conversion kit (for CTO) Memory Module Conversion kit-2GB (1GB DIMM x 2)
PGBRU2BC (for CTO)
Memory Module Conversion kit-4GB (2GB DIMM x 2)
PGBRU4BC (for CTO)
*. Notes on installing memory
1. Memory is installed by pairs of DIMMs of the same capacity. Installation of one DIMM or a mixed-capacity pair is impossible.
2. The memory capacities of the slots should be in ascending order in the following sequence:
DIMM slots 1,2 (Bank0) -> DIMM slots 3,4 (Bank1) -> DIMM slots 5,6 (Bank2)
(Available Memory Area)
*1 : "1.0GB" is being used for PCI resource management
Same as the size of mounted memory
Size of Mounted Memory minus "1.0GB"(*1)
Same as the size of mounted memory
Size of Mounted Memory minus "1.0GB"(*1)
Same as the size of mounted memory
Same as the size of mounted memory
Max: 2 HDDs HDD U320 10k 73GB hot plug 1"
PG-HDH71K
PGBHDH71K (for CTO)
HDD U320 10k 147GB hot plug 1"
PG-HDH41K
PGBHDH41K (for CTO)
HDD U320 10k 300GB hot plug 1"
PG-HDH31K
PGBHDH31K (for CTO)
HDD U320 15k 73GB hot plug 1"
PG-HDH75K
PGBHDH75K (for CTO)
HDD U320 15k 147GB hot plug 1"
PG-HDH45V
PGBHDH45V (for CTO)
8.0GB
Windows® 2000 Server (SP4) /
Windows Server
TM
2003, Standard Edition /
Windows Server
TM
2003 R2, Standard Edition
OS
Mounted Memory Available Memory Area
12.0GB
3.0GB
4.0GB
7.0GB
8.0GB
Windows® 2000 Advanced Server
Windows Server
TM
2003 x64 Editions /
Windows Server
TM
2003 R2 x64 Editions
Other OS
Memory
Memory
Slot
PRIMERGY BX620 S2
Connecting Internal HDD and Internal Backup Devices
Internal HDD
Onboard SCSI
Controller (Wide)
Memory
Slot
PRIMERGY BX620 S2 / BX620 S3
SCSI/RAID Configuration
*. Spare Memory function
In case of using Spare Memory function, same DIMMs
of more than two banks are required to be installed.
Available memory capacity is "installed memory" minus
"capacity of one bank".
Max: 1
Twist Pair Cable (category 5e)
Expansion Card Slot Module Eth. Ctrl 2x 1000-BASE-T Cu
PG-CS102 PG-1862
*Dual port
SCSI Ctrl U160 SCSI Cable HDCI 1.5m PRIMERGY SX10
PG-128 PG-CBLS001 PG-R1BC4
SCSI Cable HDCI 5m
PG-CBLS002
In case that Expansion Card Slot Module (PG-CS102) is mounted on BX620 S2, and PCI card is monted on Expansion Card Slot Module,
the slot of mounted PCI card is at front side of BX600 S2 Blade Server System Unit (PGUR3SC1).
The cable connected to PCI card can be gone from front side to back side of BX600 S2 Blade Server System Unit (PGUR3SC1)
by using Front-Rear Cable-Thru kit (PG-R1CM1).
Front-Rear Cable-Thru kit (PG-R1CM1) is mounted just under BX620 S2 and occupies 1U.
Front-Rear Cable-Thru kit
PG-R1CM1
Switch Blade /
GbE Pass-Thru Blade
Max: 1 1Gbit/s Ethernet I/O Module
PG-LND101 Switch Blade /
PGBLND101 (for CTO) GbE Pass-Thru Blade
2Gbit/s FC I/O Module
PG-FCD102 FC Switch Blade /
PGBFCD102 (for CTO) FC Pass-Thru Blade
LAN Card/Internal backup device (PRIMERGY SX10)
PRIMERGY BX620 S2
Expansion Card
Slot Module
onnecto
On-board LAN
Interface
LAN/Fibre Channel Interface
Expansion
Board Slot
PRIMERGY BX620 S2 / BX620 S3
Notes on applying Expansion Card Slot Module (PG-CS102)
Dual-Processor Blade Server
Base Unit Xeon® 5050 (3GHz)
PGUX6231A
CPU Frequencies Dual Core Intel® Xeon® 5080 (3.73GHz) *5 / 5060 (3.20GHz) *6 / 5050 (3GHz)
Second-Level-Cache 2 x 2MB
Multi-Processor max. 2 (1 for standard)
Front-Side-Bus
Chipset Intel® 5000P
Memory Standard 1GB (512MB ECC DDR2 SDRAM Fully Buffered DIMM x 2) (SDDC(Single Device Data Correction) supported)
Maximum *1 16GB (2GB ECC DDR2 SDRAM Fully Buffered DIMM x 8)
Graphics Controller ATI ES 1000 , VRAM : 16MB (PCI)
Resolution *2 640x480/800x600/1024x768/1280x1024 dot
Internal Bays Number of bays 2
2.5 inch Available HDD *3 36.7GB (PG-HDD61A) 10krpm, SAS
HDD 73.4GB (PG-HDD71A) 10krpm, SAS
Standard -
Maximum *3 146.8GB
PCI Slots
PCI Express (x4) [x4]
PCI-X (64bit/133MHz) [3.3V]
RAID Controller Onboard
SAS Controller Onboard, SAS x 2ports (with RAID1 function)
LAN Interfaces 2ports (1Gbps) ( 4ports (1Gbps) when 1Gbit/s Ethernet I/O Module (PG-LND101) (2ports(1Gbps)) is applied. ) *7
Fibre channel Interfaces optional ( 2ports (2Gbps) when 2Gbit/s FC I/O Module (PG-FCD102) (2ports(2Gbps)) is applied. ) *8
Interfaces Display (Analog RGB), USB x2(ver. 2.0), Display *9, Keyboard *9, Mouse *9
Server Management Software ServerView (standard)
 
Power supply Voltage DC12V / DC5V-Standby (provided by BX600 S2 Blade Server System Unit)
Power consumption 405W / 1458kJ/h (max.)
Dimensions (W x D x H (mm) ) 42 x 476 x 286 ( Server blade slot of BX600 S2 Blade Server System Unit x 1)
 
Weight 7.0kg (max.)
Environmental Conditions Temperature10-35°C / Humidity 20-80% (non condensing)
OS Support *4 Windows Server
TM
2003 R2, Standard Edition / Windows Server
TM
2003 R2, Enterprise Edition
Windows Server
TM
2003, Standard Edition (SP1) / Windows Server
TM
2003, Enterprise Edition (SP1)
Windows Server
TM
2003 R2, Standard x64 Edition / Windows Server
TM
2003 R2, Enterprise x64 Edition
Windows Server
TM
2003, Standard x64 Edition / Windows Server
TM
2003, Enterprise x64 Edition
Windows® 2000 Server (SP4) / Windows® 2000 Advanced Server (SP4)
Red Hat Enterprise Linux AS (v.3 for x86) / Red Hat Enterprise Linux ES (v.3 for x86)
Red Hat Enterprise Linux AS (v.4 for x86) / Red Hat Enterprise Linux ES (v.4 for x86)
Red Hat Enterprise Linux AS (v.4 for EM64T) / Red Hat Enterprise Linux ES (v.4 for EM64T)
Attached tool (Standard) ServerStart (Setup Support tool) *10
*1.Available memory capacity will be changed by the type of OS. Please find more details in Notes[Memory OS Compatibility List].
*2. Resolution is determined by functions of the display monitor and OS.
*3. HDD capacity is calculated according to the formula 1GB=1000
3
byte
*4. Drivers for Linux are not attached. Please download and use drivers of the following URL.
http://www.fujitsu.com/global/services/computing/server/ia/driver/
*5. CPU Conversion kit: Xeon 5050(3GHz/2x2MB) -> Xeon 5080(3.73GHz/2x2MB) (PGBFU33P) is available for upgrading
to Intel® Xeon® 5080 (3.73GHz).
*6. CPU Conversion kit: Xeon 5050(3GHz/2x2MB) -> Xeon 5060(3.2GHz/2x2MB) (PGBFU33N) is available for upgrading
to Intel® Xeon® 5060 (3.20GHz).
*7. 1Gbit/s Ethernet I/O Module (PG-LND101) is available when Switch Blade (PG-SW104/PG-SW105) or GbE Pass-Thru Blade (PG-LNB101)
are mounted on Network Blade Slot 3,4 of BX600 S2 Blade Server System Unit (PGUR3SC1).
BX620 S2 / BX620 S3 with 1Gbit/s Ethernet I/O Module (PG-LND101) and BX620 S2 / BX620 S3 with 2Gbit/s FC I/O Module (PG-FCD102)
are not allowed to be mounted together on same BX600 S2 Blade Server System Unit (PGUR3SC1).
*8. 2Gbit/s FC I/O Module (PG-FCD102) is available when FC Switch Blade (PG-FCS102) or FC Pass-Thru Blade (PG-FCB101)
are mounted on Network Blade Slot 3,4 of BX600 S2 Blade Server System Unit (PGUR3SC1).
BX620 S2 / BX620 S3 with 1Gbit/s Ethernet I/O Module (PG-LND101) and BX620 S2 / BX620 S3 with 2Gbit/s FC I/O Module (PG-FCD102)
are not allowed to be mounted together on same BX600 S2 Blade Server System Unit (PGUR3SC1).
*9. These are connected to KVM Module (standard) or KVM module (PG-KVB101) (optional) in BX600 S2 Blade Server System Unit (PGUR3SC1).
*10. ServerStart doesn't support Linux.
1066MHz ( Dual Core Intel® Xeon® 5080 (3.73GHz) / 5060 (3.20GHz) ) /
667MHz ( Dual Core Intel® Xeon® 5050 (3GHz) )
optional (1 : LowProfile PCI Express Card only when Expansion Card Slot Module (PGBCS104) is applied.)
optional (1 : LowProfile PCI Card only when Expansion Card Slot Module (PGBCS103) is applied.)
Type
PRIMERGY BX620 S3
Data Sheet
PRIMERGY BX620 S2 / BX620 S3
*1. When 2Gbit/s FC I/O Module (PG-FCD102) is mounted on Expansion Board Slot of BX620 S2, FC Switch Blade (PG-FCS102) or FC Pass-Thru Blade (PG-FCB101)
is required to be mounted on Network Blade Slot 3,4 of BX600 S2 Blade Server System Unit (PGUR3SC1).
BX620 S2 / BX620 S3 with 1Gbit/s Ethernet I/O Module (PG-LND101) and BX620 S2 / BX620 S3 with 2Gbit/s FC I/O Module (PG-FCD102)
are not allowed to be mounted together on same BX600 S2 Blade Server System Unit (PGUR3SC1).
*2. When 1Gbit/s Ethernet I/O Module (PG-LND101) is mounted on Expansion Board Slot of BX620 S2, Switch Blade (PG-SW104/PG-SW105) or GbE Pass-Thru Blade (PG-LNB101)
is required to be mounted on Network Blade Slot 3,4 of BX600 S2 Blade Server System Unit (PGUR3SC1).
BX620 S2 / BX620 S3 with 1Gbit/s Ethernet I/O Module (PG-LND101) and BX620 S2 / BX620 S3 with 2Gbit/s FC I/O Module (PG-FCD102)
are not allowed to be mounted together on same BX600 S2 Blade Server System Unit (PGUR3SC1).
*Components installed as standard configuration marked in grey.
*. PCI card (Eth. Ctrl 2x1Gbit PCI-E 1000-BASE-T lp (PG-2861L/PGB2861L)) should be mounted on Expansion Card Slot Module (PGBCS104).
PCI card (SCSI Ctrl U160 lp (PG-1301L/PGB1301L)) should be mounted on Expansion Card Slot Module (PGBCS103).
The slot of mounted PCI card is at front side of BX600 S2 Blade Server System Unit (PGUR3SC1).
The cable connected to PCI card can be gone from front side to back side of BX600 S2 Blade Server System Unit (PGUR3SC1)
by using Front-Rear Cable-Thru kit (PG-R1CM1).
Front-Rear Cable-Thru kit (PG-R1CM1) is mounted just under BX620 S3 and occupies 1U.
In case that BX620 S3 are added on BX600 S2 Blade Server System Unit (PGUR3SC1), it may be necessary
to change firmware version of Management Blade of BX600 S2 Blade Server System Unit (PGUR3SC1).
For details, please refer to accompanying material of BX620 S3.
Bus
Max No.
of Mount
LowProfile PCI Card,
For PRIMERGY SX10
PG-2861L /
PGB2861L
1
SCSI Ctrl U160 lp
PG-1301L /
PGB1301L
PCI/64bit 1
RemarksMountable Cards Bus
Max No.
of Mount
LowProfile PCI Express Card
RemarksMountable Cards
PCI Express (x4)Eth. Ctrl 2x1Gbit PCI-E 1000-BASE-T lp
PRIMERGY BX620 S3
Configuration Diagram
CPU
Xeon®
5080 (3.73GHz)/
5060 (3.20GHz)/
5050 (3GHz)
Xeon®
5080 (3.73GHz)/
5060 (3.20GHz)/
5050 (3GHz)
2.5 inch HDD Bay 1
(hot plug)
Hard Disk 2.5inch Bay (hot plug)
Standard Drive Ca
g
e
(
HDD x 2
p
orts
)
Bay 1
SAS
Mountable I/O Options
PRIMERGY BX620 S2 / BX620 S3
Memory
DIMM Slot 4
DIMM Slot 3
DIMM Slot 2
DIMM Slot 1
DIMM Slot 8
DIMM Slot 5
DIMM Slot 6
DIMM Slot 7
Expansion Board Slot *1,*2
2.5 inch HDD Bay 2
(hot plug)
Expansion Card
Slot Module
Bay 2
SAS
BX620 S3 ( In case that Expansion Card Slot Module (PGBCS104) is applied. )
BX620 S3 ( In case that Expansion Card Slot Module (PGBCS103) is applied. )
Notes on addition of BX620 S3
Max: 2 CPU Processor Xeon 5080 3.73GHz/2x2MB
PG-FG33P
Standard: 1 CPU PGBFG33P (for CTO)
*. This option is available when CPU Conversion kit: Xeon 5050(3GHz/2x2MB)
-> Xeon 5080(3.73GHz/2x2MB) (PGBFU33P) is applied.
Processor Xeon 5060 3.2GHz/2x2MB
PG-FG33N
PGBFG33N (for CTO)
*. This option is available when CPU Conversion kit: Xeon 5050(3GHz/2x2MB)
-> Xeon 5060(3.2GHz/2x2MB) (PGBFU33N) is applied.
Processor Xeon 5050 3GHz/2x2MB
PG-FG33M
PGBFG33M (for CTO)
*. This option is available when the processor of the base unit
is Processor Xeon 5050 3GHz/2x2MB.
*CPU Conversion Kit (available only for a Configure to Order (CTO) option; no separate shipment is possible)
CPU Conversion Kit: Dual Core Intel® Xeon® 5050 3GHz -> Dual Core Intel® Xeon® 5080 3.73GHz
Xeon 5050(3GHz/2x2MB) Convert the CPU installed as standard in the base unit to the other.
-> Xeon 5080(3.73GHz/2x2MB) (Note: This option can be ordered only as coupled with the base unit.
(for CTO) A separate shipment is not possible.)
CPU Conversion Kit: Dual Core Intel® Xeon® 5050 3GHz -> Dual Core Intel® Xeon® 5060 3.20GHz
Xeon 5050(3GHz/2x2MB) Convert the CPU installed as standard in the base unit to the other.
-> Xeon 5060(3.2GHz/2x2MB) (Note: This option can be ordered only as coupled with the base unit.
(for CTO) A separate shipment is not possible.)
Max: 16GB (2GB FB-DIMM x 8) Memory Module-1GB (512MB FB-DIMM x 2)
PG-RM1CD
Standard Memory Module: 1GB (512MB FB-DIMM x 2)
Memory Module-2GB (1GB FB-DIMM x 2)
PG-RM2CD
Memory Module-4GB (2GB FB-DIMM x 2)
PG-RM4CD
Memory Module Conversion kit (for CTO) Memory Module Conversion kit-2GB (1GB FB-DIMM x 2)
PGBRU2CD (for CTO)
Memory Module Conversion kit-4GB (2GB FB-DIMM x 2)
PGBRU4CD (for CTO)
* Notes on installing memory
1. Memory is installed by pairs of FB-DIMMs of the same capacity. Installation of one FB-DIMM or a mixed -capacity pair is impossible.
2. The memory capacities of the slots should be in ascending order in the following sequence:
DIMM slots 1,2 (Bank 1) -> DIMM slots 3,4 (Bank 2) -> DIMM slots 5,6 (Bank 3) -> DIMM slots 7,8 (Bank 4)
(Available Memory Area)
Same as the size of mounted memory
Size of Mounted Memory minus "1.0GB"
Same as the size of mounted memory
Size of Mounted Memory minus "1.0GB"
Same as the size of mounted memory
*. Memory Mirroring Function
In case of using Memory Mirroring Function, the following conditions are required.
(1) FB-DIMM x 4 or FB-DIMM x 8 should be installed.
(2) Memory capacity of each memory pair should be same.
(3) Available memory capacity is the half of installed memory.
Windows® 2000 Advanced
Server (SP4)
7.0GB
8.0GB
Others 16.0GB
PGBFU33P
PGBFU33N
Mounted Memory Available Memory Area
Windows® 2000 Server (SP4)
3.0GB
4.0GB
Product IDType
Connection Table
Memory
Memory
Slot
Memory
Slot
CPU
CPU Slot
PRIMERGY BX620 S3
PRIMERGY BX620 S2 / BX620 S3
Max: 2 HDDs HDD SAS 10k 36GB hot plug 2.5inch
PG-HDD61A
PGBHDD61A (for CTO)
HDD SAS 10k 73GB hot plug 2.5inch
PG-HDD71A
PGBHDD71A (for CTO)
Max: 1
Twist Pair Cable (category 5e)
Expansion Card Slot Module Eth. Ctrl 2x1Gbit PCI-E 1000-BASE-T lp
PGBCS104 (for CTO) PG-2861L
PGB2861L (for CTO)
*Dual port
SCSI Cable HDCI 1.8m PRIMERGY SX10
Expansion Card Slot Module SCSI Ctrl U160 lp PG-CBLS007 PG-R1BC4
PGBCS103 (for CTO) PG-1301L SCSI Cable HDCI 5m
PGB1301L (for CTO) PG-CBLS008
In case that Expansion Card Slot Module (PGBCS103/PGBCS104) is mounted on BX620 S3, and PCI card is monted on Expansion Card Slot Module,
the slot of mounted PCI card is at front side of BX600 S2 Blade Server System Unit (PGUR3SC1).
The cable connected to PCI card can be gone from front side to back side of BX600 S2 Blade Server System Unit (PGUR3SC1)
by using Front-Rear Cable-Thru kit (PG-R1CM1).
Front-Rear Cable-Thru kit (PG-R1CM1) is mounted just under BX620 S3 and occupies 1U.
Front-Rear Cable-Thru kit
PG-R1CM1
Switch Blade /
GbE Pass-Thru Blade
Max: 1 1Gbit/s Ethernet I/O Module
PG-LND101 Switch Blade /
PGBLND101 (for CTO) GbE Pass-Thru Blade
2Gbit/s FC I/O Module
PG-FCD102 FC Switch Blade /
PGBFCD102 (for CTO) FC Pass-Thru Blade
Max number of BX620 S3 installed on BX600 S2 Blade Server System Unit depends on structure of server blade.
In case of BX620 S3 which has 2 Xeon 5080(3.73GHz), Up to 9 BX620 S3 can be mounted on BX600 S2 Blade Server System Unit (PGUR3SC1).
For details, please refer to the following URL.
http://www.fujitsu.com/downloads/PRMRGY/blade-inst-cond.pdf
Connecting Internal HDD and Internal Backup Devices
Internal HDD
Onboard SAS
Controller
LAN Card/Internal backup device (PRIMERGY SX10)
Expansion Card
Slot Module
onnecto
SAS/RAID Configuration
Notes on applying Expansion Card Slot Module (PGBCS103/PGBCS104)
On-board LAN
Interface
LAN/Fibre Channel Interface
Expansion
Board Slot
PRIMERGY BX620 S3
PRIMERGY BX620 S2 / BX620 S3
Max number of BX620 S3 installed on BX600 S2 Blade Server System Unit
Base Unit
PG-SW104 PG-SW105
CTO optional
LAN Interfaces
Internal
10ports (1Gbps) 10ports (1Gbps)
External 6ports (1000BASE-T / 100BASE-TX / 10BASE-T)
Dimensions (W x D x H (mm) ) 35 x 250 x 130 35 x 250 x 130
*1. This is the type of Switch Blade which is mounted on Network Blade Slot 1 of BX600 S2 Blade Server System Unit.
*2. This is the type of Switch Blade which is mounted on Network Blade Slot 2 of BX600 S2 Blade Server System Unit.
When Switch Blade (PGBSW1041) is ordered, Switch Blade (PGBSW1040) or Switch Blade (PGBSW1050) or GbE Pass-Thru Blade(PGBLNB1010) should be ordered at a time.
When Switch Blade (PGBSW1051) is ordered, Switch Blade (PGBSW1040) or Switch Blade (PGBSW1050) or GbE Pass-Thru Blade(PGBLNB1010) should be ordered at a time.
*3. This is the type of Switch Blade which is mounted on Network Blade Slot 3 of BX600 S2 Blade Server System Unit.
*4. This is the type of Switch Blade which is mounted on Network Blade Slot 4 of BX600 S2 Blade Server System Unit.
When Switch Blade (PGBSW1043) is ordered, Switch Blade (PGBSW1042) or Switch Blade (PGBSW1052) or GbE Pass-Thru Blade(PGBLNB1012) should be ordered at a time.
When Switch Blade (PGBSW1053) is ordered, Switch Blade (PGBSW1042) or Switch Blade (PGBSW1052) or GbE Pass-Thru Blade(PGBLNB1012) should be ordered at a time.
*. When Switch Blade (PG-SW104/PG-SW105) are mounted on Network Blade Slot 3,4 of BX600 S2 Blade Server System Unit (PGUR3SC1),
the card on Expansion Board Slot of BX620 S2 / BX620 S3 should be 1Gbit/s Ethernet I/O Module(PG-LND101).
BX620 S2 / BX620 S3 with 1Gbit/s Ethernet I/O Module (PG-LND101) and BX620 S2 / BX620 S3 with 2Gbit/s FC I/O Module (PG-FCD102)
are not allowed to be mounted together on same BX600 S2 Blade Server System Unit (PGUR3SC1).
*. In case of using 10GBASE-SR connection of Switch Blade (PG-SW105), XFP Module (PG-XFPS01) is required.
GbE Pass-Thru Blade
Base Unit
PG-LNB101
CTO optional
PGBLNB1010 (*1) / PGBLNB1011 (*2) / PGBLNB1012 (*3) / PGBLNB1013 (*4)
LAN Interfaces Internal 10ports (1Gbps) (*5)
External 10ports (1000BASE-T) (fixed) (*5)
Dimensions (W x D x H (mm) ) 35 x 250 x 130
*1. This is the type of GbE Pass-Thru Blade which is mounted on Network Blade Slot 1 of BX600 S2 Blade Server System Unit.
*2. This is the type of GbE Pass-Thru Blade which is mounted on Network Blade Slot 2 of BX600 S2 Blade Server System Unit.
When GbE Pass-Thru Blade (PGBLNB1011) is ordered, Switch Blade (PGBSW1040) or Switch Blade (PGBSW1050) or GbE Pass-Thru Blade(PGBLNB1010) should be ordered at a time.
*3. This is the type of GbE Pass-Thru Blade which is mounted on Network Blade Slot 3 of BX600 S2 Blade Server System Unit.
*4. This is the type of GbE Pass-Thru Blade which is mounted on Network Blade Slot 4 of BX600 S2 Blade Server System Unit.
When GbE Pass-Thru Blade (PGBLNB1013) is ordered, Switch Blade (PGBSW1042) or Switch Blade (PGBSW1052) or GbE Pass-Thru Blade(PGBLNB1012) should be ordered at a time.
*5. Connections between internal ports and external ports are one-to-one.
*. To connect to hub/router through GbE Pass-Thru Blade, it is necessary to connect to the port of 1000BASE-T(fixed).
In case that the port of 10/100BASE-TX is connected, communication cannot be established.
*. When GbE Pass-Thru Blade (PG-LNB101) are mounted on Network Blade Slot 3,4 of BX600 S2 Blade Server System Unit (PGUR3SC1),
the card on Expansion Board Slot of BX620 S2 / BX620 S3 should be 1Gbit/s Ethernet I/O Module(PG-LND101).
BX620 S2 / BX620 S3 with 1Gbit/s Ethernet I/O Module (PG-LND101) and BX620 S2 / BX620 S3 with 2Gbit/s FC I/O Module (PG-FCD102)
are not allowed to be mounted together on same BX600 S2 Blade Server System Unit (PGUR3SC1).
6ports (1000BASE-T / 100BASE-TX / 10BASE-T),
1port (10GBASE-SR), 1port (10GBASE-CX4),
Type
Type
PGBSW1040 (*1) / PGBSW1041 (*2) / PGBSW1042 (*3) / PGBSW1043 (*4)
Switch Blade
PGBSW1050 (*1) / PGBSW1051 (*2) / PGBSW1052 (*3) / PGBSW1053 (*4)
PRIMERGY BX620 S2 / BX620 S3
Switch Blade
Data Sheet
GbE Pass-Thru Blade
Data Sheet
FC Switch Blade
Base Unit
PG-FCS102
CTO optional
PGBFCS102 (*1) / PGBFCS1022 (*2)
Fibre Channel Internal 8ports (4Gbps) ( 10ports (4Gbps when FCSW Upgrade kit:Porton Demand (PG-FCSU102) is applied )
Interfaces External 4ports (4Gbps, Fibre Channel) ( 6ports (4Gbps, Fibre Channel) when FCSW Upgrade kit:Porton Demand (PG-FCSU102) is applied )
Dimensions (W x D x H (mm) ) 35 x 250 x 130
*1. This is the type of FC Switch Blade which is mounted on Network Blade Slot 3 of BX600 S2 Blade Server System Unit.
*2. This is the type of FC Switch Blade which is mounted on Network Blade Slot 4 of BX600 S2 Blade Server System Unit.
When FC Switch Blade (PGBFCS1022) is ordered, FC Switch Blade (PGBFCS102) or FC Pass-Thru Blade (PGBFCB101) should be ordered at a time.
*. The max number of available ports under initial condition is as follows.
internal : 8ports
external : 4ports
If it is necessary to connect more than 8 BX620 S2/BX620 S3, FCSW Upgrade kit:Porton Demand(PG-FCSU102) is required to increase available ports.
*. When FC Switch Blade (PG-FCS102) are mounted on Network Blade Slot 3,4 of BX600 S2 Blade Server System Unit (PGUR3SC1),
the card on Expansion Board Slot of BX620 S2 / BX620 S3 should be 2Gbit/s FC I/O Module (PG-FCD102).
BX620 S2 / BX620 S3 with 1Gbit/s Ethernet I/O Module (PG-LND101) and BX620 S2 / BX620 S3 with 2Gbit/s FC I/O Module (PG-FCD102)
are not allowed to be mounted together on same BX600 S2 Blade Server System Unit (PGUR3SC1).
*. SFP Module (PG-SFPS02), whose number is same as that of used external ports, should be ordered.
FC Pass-Thru Blade
Base Unit
PG-FCB101
CTO optional
PGBFCB101 (*1) / PGBFCB1012 (*2)
Fibre Channel Internal 10ports (2Gbps) (*3)
Interfaces External 10ports (2Gbps,Fibre Channel) (*3)
Dimensions (W x D x H (mm) ) 35 x 250 x 130
*1. This is the type of FC Pass-Thru Blade which is mounted on Network Blade Slot 3 of BX600 S2 Blade Server System Unit.
*2. This is the type of FC Pass-Thru Blade which is mounted on Network Blade Slot 4 of BX600 S2 Blade Server System Unit.
When FC Pass-Thru Blade (PGBFCB1012) is ordered, FC Switch Blade (PGBFCS102) or FC Pass-Thru Blade (PGBFCB101) should be ordered at a time.
*3. Connections between internal ports and external ports are one-to-one.
*. When FC Pass-Thru Blade (PG-FCB101) are mounted on Network Blade Slot 3,4 of BX600 S2 Blade Server System Unit (PGUR3SC1),
the card on Expansion Board Slot of BX620 S2 / BX620 S3 should be 2Gbit/s FC I/O Module (PG-FCD102).
BX620 S2 / BX620 S3 with 1Gbit/s Ethernet I/O Module (PG-LND101) and BX620 S2 / BX620 S3 with 2Gbit/s FC I/O Module (PG-FCD102)
are not allowed to be mounted together on same BX600 S2 Blade Server System Unit (PGUR3SC1).
*. SFP Module (PG-SFPS01), whose number is same as that of used external ports, should be ordered.
Type
Type
FC Pass-Thru Blade
Data Sheet
FC Switch Blade
Data Sheet
PRIMERGY BX620 S2 / BX620 S3
BX600 S2 Blade Server System Unit
Base Unit
PGUR3SC1
Slots Server Blade 10 (hot plug) (*1)
Network Blade
(LAN/Fibre Channel)
Management Blade (standard) 2 (Management Bladex2 standard) (hot plug)
Interfaces Display (Analog RGB) (*2), Keyboard (PS/2type Mini DIN 6pins) (*2), Mouse (PS/2type Mini DIN 6pins) (*2)
Power supply Voltage AC200V(50/60Hz) (NEMA L6-30)x 2 (Max. 4)
Power consumption 5600W / 20160kJ/h (max.)
Redundant power supply optional (hot plug)
Redundant Fan standard (hot plug)
Dimensions (W x D x H (mm) ) 446(483 incl. protruding parts) x 735(800 incl. protruding parts) x 308(7U)
 
Weight 130kg (max.)
*1. One BX620 S2/BX620 S3 occupies One Server Blade Slot.
*2. This is output of Console Swich in BX600 S2 Blade Server System Unit and Display, Keyboard and Mouse are connected to by using Console Switch Cable.
*. When BX600 S2 Blade Server System Unit (PGUR3SC1) is ordered, Switch Blade (PGBSW1040)
or Switch Blade (PGBSW1050) or GbE Pass-Thru Blade(PGBLNB1010) should be ordered at a time.
*Components installed as standard configuration marked in grey.
4 (hot plug)
Type
BX600 S2 Blade Server S
y
stem Uni
t
Data Sheet
Configuration Diagram
Management
Blade 1
Power Supply Unit 4 Power Supply Unit 3
Network Blade Slot 3
Server Blade Slot 1
Server Blade Slot 2
Server Blade Slot 3
Server Blade Slot 4
Server Blade Slot 5
Server Blade Slot 6
Server Blade Slot 7
Server Blade Slot 8
Server Blade Slot 9
Server Blade Slot 10
PRIMERGY BX620 S2 / BX620 S3
Front View
Back View
KVM Module
Management
Blade 2
Power Supply Unit 1Power Supply Unit 2
Network Blade Slot 4
Network Blade Slot 1Network Blade Slot 2
BX600 S2 Blade Server System Unit
PGUR3SC1
Max: 10
BX620 S2
BX620 S3
Switch Blade
PG-SW104 Twist Pair Cable (category 5e)
Max: 2 Blades PGBSW1040 (for CTO)
(for Network Blade Slot 1)
PGBSW1041 (for CTO)
(for Network Blade Slot 2)
Switch Blade
PG-SW105 Twist Pair Cable (category 5e)
PGBSW1050 (for CTO)
(for Network Blade Slot 1)
PGBSW1051 (for CTO) XFP Module
Multi Mode Fibre Channel Cable
(for Network Blade Slot 2) PG-XFPS01
IB Cable
GbE Pass-Thru Blade
PG-LNB101 Twist Pair Cable (category 5e)
PGBLNB1010 (for CTO)
(for Network Blade Slot 1)
PGBLNB1011 (for CTO)
(for Network Blade Slot 2)
* To connect to hub/router through GbE Pass-Thru Blade, it is necessary to connect to the port of 1000BASE-T(fixed).
In case that the port of 10/100BASE-TX is connected, communication cannot be established.
BX600 S2 Blade Server S
y
stem Uni
t
Connection Table
Server Blade
Slots
Server Blade
Network Blade
Slots
LAN Interfaces ( Use of Network Blade Slot 1,2 )
PRIMERGY BX620 S2 / BX620 S3
( 1000BASE-T )
( 10GBASE-SR )
( 10GBASE-CX4 )
Notes on GbE Pass-Thru Blade (PG-LNB101)
Switch Blade
PG-SW104 Twist Pair Cable (category 5e)
Max: 2 Blades PGBSW1042 (for CTO)
(for Network Blade Slot 3)
PGBSW1043 (for CTO)
(for Network Blade Slot 4)
Switch Blade
PG-SW105 Twist Pair Cable (category 5e)
PGBSW1052 (for CTO)
(for Network Blade Slot 3)
PGBSW1053 (for CTO) XFP Module
Multi Mode Fibre Channel Cable
(for Network Blade Slot 4) PG-XFPS01
IB Cable
GbE Pass-Thru Blade
PG-LNB101 Twist Pair Cable (category 5e)
PGBLNB1012 (for CTO)
(for Network Blade Slot 3)
PGBLNB1013 (for CTO)
(for Network Blade Slot 4)
FC Switch Blade
PG-FCS102
SFP Module Multi Mode Fibre Channel Cable
PGBFCS102 (for CTO)
PG-SFPS02
(for Network Blade Slot 3)
PGBFCS1022 (for CTO)
(for Network Blade Slot 4)
FCSW Upgrade kit:Porton Demand
( internal : 8 ports -> 10 ports
external : 4ports -> 6ports )
PG-FCSU102
FCSW Upgrade kit:ISL Trunking
PG-FCSU103
FC Pass-Thru Blade
PG-FCB101 SFP Module Multi Mode Fibre Channel Cable
PGBFCB101 (for CTO)
PG-SFPS01
(for Network Blade Slot 3)
PGBFCB1012 (for CTO)
(for Network Blade Slot 4)
* To connect to hub/router through GbE Pass-Thru Blade, it is necessary to connect to the port of 1000BASE-T(fixed).
In case that the port of 10/100BASE-TX is connected, communication cannot be established.
* The max number of available ports under initial condition is as follows.
internal : 8ports
external : 4ports
* If it is necessary to connect more than 8 BX620 S2/BX620 S3, FCSW Upgrade kit:Porton Demand(PG-FCSU102) is required to increase available ports.
LAN/Fibre Channel Interfaces ( Use of Network Blade Slot 3,4 )
PRIMERGY BX620 S2 / BX620 S3
Network Blade
Slots
( 1000BASE-T )
( 10GBASE-SR )
( 10GBASE-CX4 )
Notes on GbE Pass-Thru Blade (PG-LNB101)
Notes on GbE Pass-Thru Blade (PG-LNB101)
BX600 S2 Blade Server S
y
stem Uni
t
Please refer to the following connection patterns between BX620 S2 / BX620 S3 and Network Blade.
LAN Onboard LAN
+ LAN 1Gbit/s Ethernet I/O Module
(optional)
cannot be mounted with
2Gbit/s FC I/O Module (*)
+ Fibre Channel 2Gbit/s FC I/O Module
(optional)
cannot be mounted with
1Gbit/s Ethernet I/O Module (*)
* BX620 S2 / BX620 S3 with 1Gbit/s Ethernet I/O Module (PG-LND101) and BX620 S2 / BX620 S3 with 2Gbit/s FC I/O Module (PG-FCD102)
are not allowed to be mounted together on same BX600 S2 Blade Server System Unit (PGUR3SC1).
Display/Keyboard/Mouse
Max: 1 Standard: 1 Unit
Display/Keyboard/Mouse
KVM Module Conversion kit
PGBKVU101
Twist Pair Cable Twist Pair Cable
HUB PRIMERGY BX600
KVM Module
PG-KVB101
* KVM Module (PG-KVB101), PRIMERGY BX600 Management Blade and Client PC are connected to same network.
Max: 2 Blades
PRIMERGY BX600
RS-232C Cross Cable Operator Client
Standard: 2 Blades
Management Blade * for setting Management Blade
* one cable attached with BX600 S2 Blade
Server System Unit (PGUR3SC1) as standard.
Twist Pair Cable HUB Supervisor Client
Network Blade 3
(optional : FC Switch Blade (PG-FCS102/PGBFCS102) /
FC Pass-Thru Blade (PG-FCB101/PGBFCB101) )
Network Blade 4
(optional : FC Switch Blade (PG-FCS102/PGBFCS1022) /
FC Pass-Thru Blade (PG-FCB101/PGBFCB1012) )
Switch Blade / GbE Pass-Thru Blade /
FC Switch Blade / FC Pass-Thru Blade
Network Blade
Network Blade 1
(optional : Switch Blade (PG-SW104/PGBSW1040/PG-SW105/PGBSW1050) /
GbE Pass-Thru Blade(PG-LNB101/PGBLNB1010) )
Network Blade 2
(optional : Switch Blade (PG-SW104/PGBSW1041/PG-SW105/PGBSW1051) /
GbE Pass-Thru Blade(PG-LNB101/PGBLNB1011) )
Network Blade 3
(optional : Switch Blade (PG-SW104/PGBSW1042/PG-SW105/PGBSW1052) /
GbE Pass-Thru Blade(PG-LNB101/PGBLNB1012) )
Network Blade 4
(optional : Switch Blade (PG-SW104/PGBSW1043/PG-SW105/PGBSW1053) /
GbE Pass-Thru Blade(PG-LNB101/PGBLNB1013) )
Port 2
BX620 S2 / BX620 S3
Port 2
Port
Port 2
Port 1
Port 1
Port 1
Structure Interface
Connection between BX620 S2 / BX620 S3 and Network Blade
Management
Blade Slots
Management Blade
PRIMERGY BX620 S2 / BX620 S3
KVM Module Slot
KVM Module
PRIMERGY BX600 KVM Module
Notes on KVM Module (PG-KVB101)
BX600 S2 Blade Server S
y
stem Uni
t
Max: 4 Units
Power Supply Module
PG-PU118
AC Plug Outlet
Standard: 2 Units
PGBPU118 (for CTO)
Specifications are subject to change without notice. For the latest detailed information, contact your local representative.
All brand names and product names are trademarks and registered trademarks of their respective holders.
©2006 Fujitsu Limited. All rights reserved. Printed in Japan.
Global Business Development & Marketing
Business Strategy & Planning
System Products
URL http://primergy.fujitsu.com
Power Supply
Unit Slots
Power Supply Unit
PRIMERGY BX620 S2 / BX620 S3
BX600 S2 Blade Server S
y
stem Uni
t
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

Fujitsu Primergy BX620 S2 System Configuration And Order-Information Manual

Type
System Configuration And Order-Information Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI