4. Backfill hole after installation with eight to ten inches of pea gravel or sand.
NOTE: Luminaires are supplied with 36" of 18-2 cable pigtail for secure connection to the
main supply cable. The wiring is to be protected by routing in close proximity
to the luminaire. The wiring shall be buried a maximum of 6 inches (15.2cm)
in order to connect the main supply cable.
5. Supply power to luminaire and check for proper operation.
INSTRUCTIONS FOR POUR CONCRETE INSTALLATION
NOTE: Pour concrete installation requires conduit feed. UL listed flexible conduit is
recommended for in and out connections to ease fixture position and adjustment
during installation.
1. Dig hole approximately 14" deep by 12" diameter.
2. Install conduit through inlets in bottom of luminaire using Teflon tape or thread sealant.
3. Using inlet plugs (provided), plug unused holes in wire compartment.
4. Position luminaire top cover to protrude above grade to allow future cover removal.
NOTE: For flush mount pour concrete installation, a trim ring (concrete mount frame), is
available. Consult factory or your local distributor.
5. Pull supply wires through conduit into luminaire and wire as required with silicone
wire nuts (provided).
6. Using standard masonry procedures, support luminaire in selected location. Pour concrete
at least 2" thick.
7. Supply power to luminaire and check for proper operation.
IMPORTANT SAFETY INSTRUCTIONS
LIGHTED LAMP IS HOT!!
ARNING: TO REDUCE THE RISK OF FIRE, OR INJURY TO
PERSONS:
1. Turn off/unplug and allow to cool before replacing lamp.
2. Lamps get hot quickly! Contact only switch/plug when turning on.
3. Do not touch hot lens, guard or enclosure.
4. Keep lamp away from material that may burn.
5. Do not touch the lamp at any time. Use a soft cloth. Oil from
the skin may damage lamp.
6. Do not operate luminaire fitting with a missing or damaged cover.
LAMP INSTALLATION/REPLACEMENT:
CAUTION: Do not exceed maximum wattage marked on luminaire label.
1. To prevent electrical shock, disconnect transformer from electrical supply before service.
2. Loosen the eight (8) cover screws and remove cover.
3. Remove gasket.
4. Replace lamp with correct wattage and type marked on fixture label.
NOTE: DO NOT touch Halogen lamp with bare hands. Always use soft cloth or the
plastic wrapping (if available) from the lamp to handle the lamp.
5. Clean gasket mounting surface and gasket.
6. Re-install gasket and cover and tighten the eight (8) screws evenly.
VISTA PROFESSIONAL OUTDOOR LIGHTING Division of U.S.T.E. Inc. Website: www.vistapro.com
1625 Surveyor Avenue, Simi Valley, CA 93063 (805) 527-0987 FAX: (805) 527-6830 (800) 766-847