Digital Sound Level Meter V1
Highlite International B.V. Vestastraat 2 6468 EX Kerkrade the Netherlands
Ordercode: 91004
MANUAL
ENGLISH
1
Ordercode: 91004
Digital Sound Level Meter
Table of contents
Warning ............................................................................................................................................................................... 2
Unpacking Instructions ................................................................................................................................................. 2
Safety Instructions ......................................................................................................................................................... 2
Operating Determinations .......................................................................................................................................... 3
Return Procedure .......................................................................................................................................................... 4
Claims .............................................................................................................................................................................. 4
Description of the device ................................................................................................................................................. 5
Overview ........................................................................................................................................................................ 6
Installation ........................................................................................................................................................................... 6
Set Up and Operation ....................................................................................................................................................... 7
Replacing batteries ...................................................................................................................................................... 8
Maintenance ...................................................................................................................................................................... 9
Troubleshooting ................................................................................................................................................................. 9
Product Specifications ....................................................................................................................................................10
Dimensions ........................................................................................................................................................................11
Notes ..................................................................................................................................................................................12
2
Ordercode: 91004
Digital Sound Level Meter
Warning
Unpacking Instructions
Immediately upon receiving this product, carefully unpack the carton and check the contents to ensure
that all parts are present, and have been received in good condition. Notify the dealer immediately and
retain packing material for inspection if any parts appear damaged from shipping or the carton itself
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be
returned to the factory, it is important that the fixture be returned in the original factory box and packing.
Safety Instructions
Every person involved with the installation, operation and maintenance of this device has to:
be qualified
follow the instructions of this manual
Before the initial start-up, please make sure that there is no damage caused by transportation.
Should there be any, consult your dealer and do not use the device.
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to
follow the safety instructions and warning notes contained in this manual.
Please consider that damages caused by manual modifications to the device are not subject to
warranty.
This device contains no user-serviceable parts. Refer servicing to qualified technicians only.
3
Ordercode: 91004
Digital Sound Level Meter
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance of
this manual or any unauthorized modification to the device.
Never remove warning or informative labels from the unit.
Do not open the device and do not modify the device.
Do not disconnect and reconnect the device in short intervals, as this would reduce the device’s life.
Only use the device indoors, avoid contact with water or other liquids.
Avoid flames and do not put close to flammable liquids or gases.
Always remove the batteries, when the device is not used or before cleaning!
Make sure that the device is not exposed to extreme heat, moisture or dust.
If the device is dropped or struck, have a qualified engineer inspect for safety before operating.
If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not
switch it on immediately. The arising condensation water might damage your device. Leave the
device switched off until it has reached room temperature.
If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely
(preferably in the original packing material), and return it to your Showtec dealer for service.
Repairs, servicing and electric connection must be carried out by a qualified technician.
WARRANTY: Till one year after date of purchase.
Operating Determinations
This device is not designed for permanent operation. Consistent operation breaks will ensure that the
device will serve you for a long time without defects.
The maximum ambient temperature t
a
= 40°C must never be exceeded.
The relative humidity must not exceed 50 % with an ambient temperature of 40° C.
If this device is operated in any other way than the one described in this manual, the product may
suffer damages and the warranty becomes void.
You endanger your own safety and the safety of others!
4
Ordercode: 91004
Digital Sound Level Meter
Return Procedure
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.
Package must be clearly labelled with a Return Authorization Number (RMA number). Products returned
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility.
Call Highlite 0031-455667723 or mail aftersales@highlite.com and request an RMA prior to shipping the
fixture. Be prepared to provide the model number, serial number and a brief description of the cause for
the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is
the customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use.
Note: If you are given an RMA number, please include the following information on a piece of paper
inside the box:
01) Your name
02) Your address
03) Your phone number
04) A brief description of the symptoms
Claims
The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be
reported to the carrier upon receipt of merchandise.
It is the customer's responsibility to report and submit claims with the shipper in the event that a fixture is
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt
of the delivery.
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless
agreed otherwise in writing.
Complaints against us must be prepared in writing or sent by fax within 10 working days after receipt of
the invoice. After this period complaints will not be handled anymore.
Complaints will only then be considered if the client has so far complied with all parts of the agreement,
regardless of the agreement from which the obligation is resulting.
5
Ordercode: 91004
Digital Sound Level Meter
Description of the device
Features
Below, the main features of the Showtec Sound Level Meter.
Power supply: 6 x 1,5V AAA battery
LCD digital display
Analog bar indicator
Wide dynamic range
Auto/manual range
Fast/Slow response selectable
Max. value Hold function
A/C weighting selection
Date and time display
AC/DC auxiliary output
Backlight
Low power indication
Frequency: 20 Hz - 8 kHz Hz
Sampling Rate: 2 times/s
Resolution: 0,1dB
Accuracy: ±1.5dB
Response frequency: 31.5Hz8kHz
Dynamic range: 50dB
Frequency weighting: A\C
Time weighting: FAST 125ms, SLOW 1sec
Microphone: Electret Condenser microphone
Digital display: 4 digitals, resolution 0.1dB
Analog bar display: Each analog bar is as 1dB
Sampling rate 20 times/s
Auto-range: Micro-computer can choose the best measurement ranges
Over range indicator: UNDER(less than range) and OVER (over range )
AC signal output: 0.707 Vrms at FS (Auto-range mode isn’t included) Output impedance approx.
600Ω
DC signal output: 10mV/dB Output impedance approx. 100Ω
Power supply: 6x LR03 AM4 1.5V SIZE AAA alkaline cell
Power life: About 35hrs(alkaline cells)
Measurement ranges: 3080dB, 4090dB,50100dB, 60110dB, 70120dB,80130dB.
AC adapter: Voltage 9vDC
Voltage ripple <100mVpp
Supply Current >100mADC
Socket: pin: Ground
Casing: positive
External Diameter 3.5mm
Operating temperature: 0 ~ +40
Operating humidity: 10 ~ 80%RH
Storage temperature: -10 ~ +60
Storage humidity: 10 to 70%RH
Dimensions: 245 x 80 x 35 mm (LxWxH)
Weight: 0,35 kg (including batteries)
Accessories:
Earphone plug, Operation manual, Battery, Windscreen, computer RS-232 cable,
software for windows
6
Ordercode: 91004
Digital Sound Level Meter
Overview
Fig. 01
01) Microphone
02) LCD Display
03) Up Button
04) Down Button
05) Backlight
06) Fast/Slow
07) AC
08) Max
09) ON/OFF
Installation
Remove all packing materials from the Sound Level Meter. Check if all foam and plastic padding is
removed. Connect all cables.
Always remove the batteries before cleaning and/or servicing or if the device is not used for a longer
period of time. Damages caused by non-observance are not subject to warranty.
7
Ordercode: 91004
Digital Sound Level Meter
Set Up and Operation
Follow the directions below, as they pertain to your preferred operation mode.
Make sure that you use 1,5V AAA alkaline batteries.
Please use it according to the following usage.
Environment conditions:
Altitude: less than 2000 meters.
Relatively humidity 80% max
Operation temperature 0 ~ 40
01) The meter has been designed according to the IEC651 Type 2, ANSI S1.4 Type 2.
02) Measurement range is from 30dB to 130dB and automatic ranging.
03) Two equivalent weighted sound pressure levels, A and C
04) Corresponsive rate select: FAST/SLOW
05) Maximum value locked
06) Record data in memory: 16000 data, extended up to 128000 data according to user’s demand.
07) Infrared interface for connecting with a computer
08) Computer software for data displaying and data recording on a computer.
09) Clock and calendar function
10) AC and DC analog signals output, which can be linked to frequency analyser or X-Y axis recorder.
11) Background light for working in the night. To save power, the background light shines for 5 seconds,
then closes automatically.
12) Secondary plasticizing meter shell
13) Good circuit designed to save power, the battery can be used for a long time.
Preparation before using
01) Remove the battery cover on the back and put in six 1.5V alkalescent batteries.
02) Close the battery cover.
03) When the battery voltage drops below the operating voltage, a battery icon will start flashing
on the display. The current batteries are depleted, please replace all batteries with new ones.
04) When the DC adapter is used, insert the adapter plug into the DC9V connector on the side panel.
The method of usage
01) Press the power button, the LCD displays the default range (40~90dB) and the sound level of a spot.
If the “UNDER” or “OVER” symbol appears on the display, it indicates the sound level is less than or
more than 40~90dB,. That means the measurement is invalid. you need to set the meter’s range to a
correct position.
02) Set range:
Press LEVEL ▲ or ▼, choose the proper range, measure the sound level of the desired spot.
When the “UNDER” symbol appears on the display, it means that the range is high, you need to press
LEVEL▼ to set a lower range until the “UNDER” symbol disappears.
When the “OVER” symbol appears, it means that the range is low, you need to press LEVEL▲ to set a
higher range until the “OVER” symbol disappears.
03) Choose weighting mode:
When you measure a general noise sound level, you could choose ‘A’ weighting by pressing the AC
button. To measure an acoustic sound level , choose “C”.
04) When you want to get a real-time sound level measurement, choose FAST by pressing the FAST∕SLOW
button. To get an average sound level, choose “SLOW”.
05) When you want to get the maximum value of a sound level measurement, you have to press the
“MAX” button.
06) When you want to measure in dark surroundings or at night, you can activate the background light
by pressing “LIGHT” button.
8
Ordercode: 91004
Digital Sound Level Meter
Record and storage of measured data
01) To save real-time data in the meter, press the “FAST∕SLOW” button for 2 seconds, until the “RECORD”
symbol appears on the display. At the same time, the meter will start to record real-time data until its
memory is full. Then the display will show a “FULL” symbol, indicating that the meter cannot continue
saving the data.
02) To Delete the stored data in the Sound Level Meter’s memory, press the “LEVEL ▲” button for 2
seconds until the display shows the “CEL” symbol. Then press the “LEVEL▼” button for 2 seconds, until
the “CEL” symbol flashes. After a few seconds, the display will return to normal, indicating that the
data has been deleted.
Installing operation software in a computer
01) Insert the accessory CD into the CD-ROM driver of a computer.
02) Click “setup.EXE” to install the software onto your hard disk.
03) When the installation has finished, click “MS6701 DIGITAL SOUND LEVELMETER” in the program menu.
04) An operation window will open on your computer.
Linking and communication between the meter and a computer
01) Connect the infrared output socket of the Sound Level Meter with the RS232 interface of your
computer with the included accessory cable.
02) Run “MS6701 DIGITAL SOUND LEVELMETER”, click “START” to receive and display data.
03) By pressing the “RS232” button on the meter for 2 seconds, the real-time sound level data is
transmitted to your computer. The “SENDING” symbol appears on the display. To stop the data
transmission, press the “RS232” button again for 2 seconds.
04) By pressing the “A / C” button for 2 seconds, the data in the memory of the sound meter is
transmitted to your computer. The “SENDING MEMO” symbol will appear on the display. During
transmission the computer shows “Down loading please wait…”. When the transmission is complete,
a dialog box will open. You need to enter a filename, then you can save the data onto your
computer.
05) To open a saved file on the computer, run the software of the sound level meter, click “FILE”. Then
click “OPEN” on the menu. Select and open the corresponding filename in the dialog box.
Set time and date
01) First press the “MAX” button and then turn on the Sound meter. The display will show time(hour,
minute, second) and the second digitals are flashing. Press “LEVEL▲” or “LEVEL▼” to increase or
decrease the time; Press “MAX” to set minute, hour, mouth, year. After the setup has been
completed, turn off the Sound meter.
Calibrating Sound level Meter
01) When the Sound Level Meter is used for a long time, it’s accuracy may reduce. You need to check
and calibrate the sound meter, once a year. Calibration needs a standard sound source, please
contact us about the proper method.
Caution
01) Do not use the meter in high temperatures or in wet places.
02) When not using the Sound meter for a long time, please take out the batteries to avoid damaging
the meter.
03) Auto-range (30-130dB) is unfit for measuring instantaneous and high-impact noises.
04) To measure a sound level in a windy environment, please put a windscreen on the microphone to
avoid wind noises.
05) If mark “ ”is shown on the display, it means the voltage is low. You must replace battery, we advise
you to use alkalescent batteries.
Replacing batteries
01) Place 6 x 1,5V AAA alkaline batteries in the battery housing on the back.
02) You can monitor the battery state by looking at the battery icon on the display.
9
Ordercode: 91004
Digital Sound Level Meter
Maintenance
The operator has to make sure that safety-related and machine-technical installations are to be
inspected by an expert after every year in the course of an acceptance test.
The operator has to make sure that safety-related and machine-technical installations are to be
inspected by a skilled person once a year.
The Sound Level Meter requires almost no maintenance. However, you should keep the unit clean.
Wipe the cover with a damp cloth. Do not immerse in liquid. Wipe display clean with glass cleaner and a
soft cloth. Do not use alcohol or solvents. Make sure that connections are thoroughly dry before
supplying batteries.
If you do not use this device for a long time, please take out the batteries and place it in a dry area.
Safety symbols
Meter is protected by double insulation
Comply with European Union’s 93/68/EEC
Troubleshooting
This troubleshooting guide is meant to help solve simple problems.
If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit
operates properly, do not carry out the following steps.
If the Sound Level Meter does not operate properly, refer servicing to a technician.
Suspect one potential problem area as: the batteries.
01) Turn the device on. If the device does not start, please check the batteries. To replace the batteries,
see page 8.
02) If all of the above appears to be O.K., start the unit again.
03) If you are unable to determine the cause of the problem, do not open the Sound Level Meter, as this
may damage the unit and the warranty will become void.
04) Return the device to your Showtec dealer.
10
Ordercode: 91004
Digital Sound Level Meter
Product Specifications
Model:
Digital Sound Level Meter
Frequency:
20 Hz - 8 kHz Hz
Sampling Rate:
2 times/s
Resolution:
0,1dB
Accuracy:
±1.5dB
Response frequency:
31.5Hz 8kHz
Dynamic range:
50dB
Frequency weighting:
A\C
Time weighting:
FAST 125ms, SLOW 1sec
Microphone:
Electret Condenser microphone
Digital display:
4 digitals, resolution 0.1dB, sampling rate 2 times/s
Analog bar display:
Each analog bar is as 1dB, sampling rate 20 times/s
Measurement ranges:
3080dB, 4090dB, 50100dB, 60110dB, 70120dB, 80130dB.
Total of 6 ranges
Auto-range:
Micro-computer can choose the best measurement ranges
Over range indicator:
UNDER(less than range) and OVER (over range )
AC signal output:
0.707 Vrms at FS (Auto-range mode isn’t included) Output
impedance approx. 600Ω
DC signal output:
10mV/dB Output impedance approx. 100Ω
Digital display:
4 digitals, resolution 0.1dB
Analog bar display:
Each analog bar is as 1dB
Sampling rate:
20 times/
Power supply:
6x LR03 AM4 1.5V SIZE AAA alkaline cells
Power life:
About > 35hrs (alkaline cells) Continuous operation
AC adapter:
Voltage 9vDC
Voltage ripple <100mVpp
Supply Current >100mADC
Socket pin Ground
Casing positive
External Diameter 3.5mm
Operating temperature:
0 ~ +40
Operating humidity:
10 ~ 80%RH
Storage temperature:
-10 ~ +60
Storage humidity:
10 to 70%RH
Dimensions:
245 x 80 x 35 mm (LxWxH)
Weight:
Approx.350g(including batteries)
Max. ambient temperature t
a
:
40°C
Max. housing temperature t
B
:
80°C
11
Ordercode: 91004
Digital Sound Level Meter
Dimensions
Design and product specifications are subject to change without prior notice.
Website: www.Showtec.info
12
Ordercode: 91004
Digital Sound Level Meter
Notes
13
Ordercode: 91004
Digital Sound Level Meter
14
Ordercode: 91004
Digital Sound Level Meter
©2020 Showtec
/