Nice Apollo LPR3 Loop Detector Rack User manual

Type
User manual

Nice Apollo LPR3 Loop Detector Rack

Your newly purchased Nice Apollo LPR3 Loop Detector Rack is a versatile and reliable device designed to enhance the safety and efficiency of your gate system. With its ability to accommodate up to three standard 10-pin plug-in loop detectors, it provides comprehensive vehicle detection capabilities for various applications.

The LPR3 features a user-friendly design, allowing for easy installation and wiring. It seamlessly integrates with the Nice Apollo 1050 control board, providing real-time loop status monitoring and fault detection. The device's dry contact outputs enable direct connection to the control board, triggering gate operations based on vehicle presence or absence in the designated loop areas.

Nice Apollo LPR3 Loop Detector Rack

Your newly purchased Nice Apollo LPR3 Loop Detector Rack is a versatile and reliable device designed to enhance the safety and efficiency of your gate system. With its ability to accommodate up to three standard 10-pin plug-in loop detectors, it provides comprehensive vehicle detection capabilities for various applications.

The LPR3 features a user-friendly design, allowing for easy installation and wiring. It seamlessly integrates with the Nice Apollo 1050 control board, providing real-time loop status monitoring and fault detection. The device's dry contact outputs enable direct connection to the control board, triggering gate operations based on vehicle presence or absence in the designated loop areas.

Nice Apollo Loop
Detector Board
Model LPR3
Plug-in loop detector board
Revision 1.0.0.0_2-2014
2
LPR3 MOUNTING
The LPR3 comes attached to the mounting plate with plastic standoffs. This mounting plate has been designed to
attach to the control board mount plate at the bottom using the open slots of the plate.
Install the mounting plate as shown with screws and washers provided. This will allow for easy wiring of the LPR3 to the
1050 control board.
NOTE: The LPR3 may be mounted in alternate locations as required by the installation.
LPR3
LOOP DETECTOR 1
LOOP DETECTOR 2
LOOP DETECTOR 3
LOOP 1LOOP 2LOOP 3
V+
GND
LPD1
LPD2
LPD3
GND
FAULT
GND
Install mounting
screws here
Install mounting
screws here
PARTS IDENTIFICATION
LPR3
LOOP DETECTOR 1
LOOP DETECTOR 2
LOOP DETECTOR 3
LOOP 1LOOP 2LOOP 3
V+
GND
LPD1
LPD2
LPD3
GND
FAULT
GND
PIN 1
PIN 1
PIN 1
LPR3 Loop Detector Board
LPR3 Mount Plate
3
LPR3 WIRING
The LPR3 loop detector board has been designed to accept three standard 10 pin plug in loop detectors. Simply plug
in the desired vehicle detectors and wire to the control board to the appropriate terminals.
NOTE: Verify that the pin outputs on the vehicle loop detectors you wish to use will match the pin inputs on this board.
Pin inputs on the LPR3 Board as follows:
PIN FUNCTION PIN FUNCTION
1 Loop 6 Output B
2 Loop 7 Output B Inverted
3 No Connection 8 Output A (presence)
4 No Connection 9 Power 12-24VDC
5 No Connection 10 Common
LPR3
LOOP DETECTOR 1
LOOP DETECTOR 2
LOOP DETECTOR 3
LOOP 1LOOP 2LOOP 3
V+
GND
LPD1
LPD2
LPD3
GND
FAULT
GND
PIN 1
PIN 1
PIN 1
V+ - Incoming power (positive)
GND - Incoming power (negative)
LPD1 - Loop detector 1 output
LPD2 - Loop detector 2 output
LPD3 - Loop detector 3 output
GND - Common for all detectors
FAULT - Monitored output for all detectors
GND - Common output for FAULT
LOOP 1 - Input for standard loops
LOOP 2 - Input for standard loops
LOOP 3 - Input for standard loops
Terminal descriptions as follows:
V+ - Incoming power 12 - 24 VDC
GND - Incoming power common or ground
LPD1 - Dry contact normally open output for loop detector 1
LPD2 - Dry contact normally open output for loop detector 2
LPD3 - Dry contact normally open output for loop detector 3
GND - Common or ground output for LPD1, LPD2, LPD3
FAULT - Dry contact normally open output for fault or monitored inputs - When any loop detector senses a fault with
the incoming loop wires this output will send a fault signal to the board prohibiting the board from operating the
gate until the fault is cleared
GND - Common or ground for FAULT output
LOOP 1 - Input for standard loops for Loop detector 1
LOOP 2 - Input for standard loops for Loop detector 2
LOOP 3 - Input for standard loops for Loop detector 3
4
The following example shows the typical wiring of the LPR3 loop detector board to the 1050 control board for a swing
gate setup where:
Loop detector 1 is a Safety loop
Loop detector 2 is a Shadow loop
Loop detector 3 is an Exit loop
The following example shows the typical wiring of the LPR3 loop detector board to the 1050 control board for a slide
gate setup where:
Loop detector 1 is a Safety loop
Loop detector 2 is a Safety loop
Loop detector 3 is an Exit loop
SWING GATE WIRING EXAMPLE
SLIDE GATE WIRING EXAMPLE
LPR3
LOOP DETECTOR 1
LOOP DETECTOR 2
LOOP DETECTOR 3
LOOP 1LOOP 2LOOP 3
V+
GND
LPD1
LPD2
LPD3
GND
FAULT
GND
SAFETY
SAFETY
EXIT
SAFETY
SAFETY
EXIT
FOR SOLAR APPLICATIONS WHERE 1050 BOARD IS SET
TO STANDBY - CONNECT POWER TO TERMINALS 10 & 11
LPR3
LOOP DETECTOR 1
LOOP DETECTOR 2
LOOP DETECTOR 3
LOOP 1LOOP 2LOOP 3
V+
GND
LPD1
LPD2
LPD3
GND
FAULT
GND
SAFETY
SHADOW
EXIT
SAFETY
SHADOW
EXIT
FOR SOLAR APPLICATIONS WHERE 1050 BOARD IS SET
TO STANDBY - CONNECT POWER TO TERMINALS 10 & 11
5
Nice Group USA Limited Warranty – 2 (TWO) YEARS
Nice Group USA (“Manufacturer”) warrants this product shall be free from defects in materials and
workmanship for a period of 2 years from the manufacture date. These warranties are in lieu of all other
warranties expressed or implied and shall be considered void if the product is damaged due to, but
not limited to, improper installation, improper use, terrorism or acts of God. The proper operation of
this product is dependent on your compliance with the instructions regarding installation, operation,
maintenance, and testing. Failure to comply strictly with those instructions will void this limited warranty in
its entirety.
If, during the 2 year time period from the date of manufacture, this product appears to contain a defect
covered by this limited warranty, call the manufacturer service center at 1-800-226-0178 before
uninstalling and/or dismantling this product. The technical assistance department at the manufacturer
will discuss the problems you are experiencing in order to conrm the product defect. You will provide
the information from the dated proof of purchase receipt to conrm the warranty period or the technician
will conrm your extended warranty period through your registration information on le. The technician
will give you the shipping information you need to return your product. Your product must be returned to
the manufacturer service center in a prepaid and insured manner. Should your product be covered under
the warranty policy, your product will be repaired, replaced with a factory rebuilt product or replaced with
a new product (at the manufacturer’s discretion) at no cost to you and sent back to you via standard
ground freight.
THIS WARRANTY AND THE OBLIGATIONS AND LIABILITIES OF MANUFACTURER ARE
EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. Under no circumstances shall the manufacturer be liable for consequential,
incidental or special damages of any kind whatsoever. The manufacturer’s liability for a breach
of warranty, breach of contract, negligence or strict liability cannot exceed the cost of the
warrantied product. No person is authorized to assume for the manufacturer any other liability
in connection with the sale of this product.
WARRANTY
Contact us Nice Group USA Inc.
12625 Wetmore Road Suite 218
San Antonio, TX 78247
Ph. +1.210.545.2900
Fax +1.210.545.2915
www.niceapollo.com
www.facebook.com/NiceApollo
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Nice Apollo LPR3 Loop Detector Rack User manual

Type
User manual

Nice Apollo LPR3 Loop Detector Rack

Your newly purchased Nice Apollo LPR3 Loop Detector Rack is a versatile and reliable device designed to enhance the safety and efficiency of your gate system. With its ability to accommodate up to three standard 10-pin plug-in loop detectors, it provides comprehensive vehicle detection capabilities for various applications.

The LPR3 features a user-friendly design, allowing for easy installation and wiring. It seamlessly integrates with the Nice Apollo 1050 control board, providing real-time loop status monitoring and fault detection. The device's dry contact outputs enable direct connection to the control board, triggering gate operations based on vehicle presence or absence in the designated loop areas.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI