Lang LCG-241D User manual

Category
Microwaves
Type
User manual

This manual is also suitable for

INSTRUCTIONS FOR THE TECHNICAL EXPERT
09 II1999
39D0910
LCG-241D & LCG-241DP
IMPORTANT IMPORTANT IMPORTANT
Post in a prominent location, a set of instructions to be followed in the event
the user smell gas. Obtain these instructions from your local gas supplier.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors
and liquids in the vicintiy of this or any other gas appliance.
In the event a gas odor is detected, shut down units at the main shut-off valve
and contact the local gas company or supplier for service.
WARNING: Improper installation, adjustment, alteration, service or
maintenance can cause property damage, injury or death. Read the
installation, operating and maintenance intructions thoroughly before installing
or servicing this equipment.
Installation, startup and adjustments of this appliance should be accomplished
by personnel qualified to install gas equipment.
Retain this manual for future reference.
- 1 -
1. Preliminary operations
Make sure the appliance is supplied complete and has not been
damaged in transit.
2. Positioning
Keep the appliance area free and clear of combustible material and do not obstruct the flow of
combustion or ventilation air.
The installation of any components such as a vent hood, grease extractors, and/or fire
extinguisher systems, must conform to the their applicable nationally recognized installation
standards.
3. Gas connection
For the exact position and size of connections, consult the gas connection chart
enclosed in Section B.
All gas connections must be in accordance with local codes and comply with the National
Fuel Gas Code ANSI Z223.1 latest edition, Natural Gas Installation Code CAN/CGA - B149.1
or Propane Installation Code CAN/CGA - B149.2.
Connect each oven separately. A gas shut off valve must be installed to the oven(s) and
located in an accessible area.
This appliance and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of 1/2
PSGI (3.45 kPA) and the appliance must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure testing of the gas supply
system at test pressures equal to or less than 1/2 PSIG (3.45 kPA).
3.1 Test gas
Check the data plate to make sure that the appliance has been tested for the type of
gas with wich it is to be operated.
Always check the pressure of the the gas supply. For this purpose, use the pressure test
outlet provided on the appliance, following procedure outlined in section B.
Test for gas leaks. Use a commercial leak detector or a soap and water solution.
Model XXX
Serial number
NAT. - 7" 4.5" Btu/h
120V1N 60 Hz A
1) Gas type and supply pressure
2) Injector pressure
3) Input rating Btu/h
WARNING
DO NOT USE AN OPEN FLAME TO TEST FOR GAS LEAKS.
Section A
GENERAL INSTRUCTIONS
1 2 3
- 2 -
4. Electrical connection
The appliace must be electrically grounded in accordance with local codes, or in the absence
of local codes, with the
National Electrical Code, ANSI/NFPA 70
, or the
Canadian Electrical
Code, CSA C22.1
-.2.
4.1 Operating voltage
Check the data plate to make sure the operating voltage and frequency of the
appliance correspond to those of mains supply.
Adhere scrupulously to the indications in the technical chart and in the wiring diagram,
and the instructions contained in section B.
In the notes for the customer service is indicated the location of the wiring diagram on
the appliance.
Check the current absorption indicated on the data plate to determine the cross-
sectional area of the supply cable.
5. Water connection
This appliance is to be installed to comply with the applicable Federal, state, or local
plumbing codes having jurisdiction.
Always install a stop-valve upstream of the appliance.
Downstream of the stop-cock, install appropriate fittings for easy disconnection of the
appliance and filters which can easily be inspected and cleaned.
Use materials, seals and fittings approved according to applicable standards. Use
suitable pipes which have properly treated in order to prevent the release of iron
oxides into the water (as these can alter the taste of the food and mark stainless
steel).
Make sure the water specifications are within the limits indicated in section B.
If necessary, install a suitable water treatment system.
Model XXX Serial number
NAT. - 7" 4.5" Btu/h
120V1N 60 Hz A
XXXXXXXXXX 0000
0000000000000000000
208V3 ~ A Hz kW
Section A
GENERAL INSTRUCTIONS
- 1 -
46.4"
32.6"
2.9"
5.1"
9.4"
5.7"
13.5"
14"
17.7"
35"
2"
1.3"
1.9"
43.3"
15.7"
59"
46.4"
22.8"
3.4 A
1.1 kW
3.4 A
1.1 kW
115.000 Btu/h
115.000 Btu/h
1. INSTALLATION
LCG-241D
LCG-241DP
1.1 Connections
• leave at least 4" clearance
between the rear of the appliance and the
wall
• leave at least 20" clearance at the
sides of the appliance
1.2 Positioning
1.3 Specifications
(total weight of the appliance is marked on the packaging)
All clearance requirements are the same for combustible or non combustible constructions.
For use only on non combustible foor.
The cooling outlets of the control
section of the oven (side panel)
must not be near sources of
hot fumes or steam.
Ø
3
/
4
" NPT
Gas inlet
Cable gland
Equipotential terminal
Flue outlet
*
Terminal board 3 Ph
Water inlet
Water drain
Ø 1"
1
/
2
Ø
3
/
4
"
*
The oven must be installed under a ventilation hood only.
Not suitable for connection to type B gas vent.
Maximum sound pressure is no higher than 70 dB (A)
ELECTRICAL RATINGGAS
VOLTAGE POWER RATINGINPUT RATING MAX. LOAD (A)
208V 3 Ph 60HzNatural gas
240V 3 Ph 60HzPropane
min. Ø 1"
1/2
min. 5% (3°)
max. 5 ft
min. Ø 1"
1/2
3/4"
1-1
1. INSTALLATION
1.4 Installation - procedure
Fit the following units on
the top of the oven:
1)
Flue outlet
2) Steam vent pipe
Connecting the water
supply
3) Remove the lh side
panel by unscrewing
the two fixing screws
at the bottom (if the
optional spray gun is
fitted - also the relative
fixing screws must be
removed).
4) Fit the supplied filters on the water inlet con-
nections in an accessible position.
The appliance must be supplied exclusively with
cold water conforming to the following specifi-
cations:
- pressione tra 200 e 600 kPa (2 ÷ 6 bar);
- grado di mineralizzazione tra 9 e 13 °Fr;
- PH = da 7 a 7,5.
- cloruri = max. 150 mg/l
Internal pressure gauges must give a reading
of 100 kPa (15 PSI); if the reading is
different, correct by adjusting the pressure
regulators.
Water drain
WARNING: to ensure the
appliance operates
correctly and to avoid the
risk of serious damage,
the drain must be vented
(i.e. in communication with
the atmosphere).
The material of the
drainage pipe must be heat
resistant type and not
flexible.
32
1
Spray gun
support
Water
pressure
regulator
screws
Pressure
gauges
Pressure:
between 200 and 600 kPa
(30 - 80 PSI);
pH: from 7 to 7.5;
Conductivity: less than 200 µS/cm;
t.d.s. < 100 ppm
Hardness: from 9 to 13 °f (= 5÷7 °d = 6,3÷8,8 °e =
90÷125 ppm)(5 ÷ 10° clark);
Max. salinity and ion content in mg/l:
- chlorides < 30; sulphates < 40; Fe (iron) < 0.1; Cu
(copper) < 0.05; Mn (manganese) < 0.05.
4
1-2
1. INSTALLATION
1.5 Electrical connection
Equipotential connection
• The equipotential terminal ( ) is located
beneath the appliance at the rear lh cor-
ner.
Mains connection
• Remove the lh side panel as indicated in
heading 1.4.
• Read the general precautionary notes in
Chapter 4, Section A. of this
handbook.
• Fit the suitable cable gland in the relative
hole.
• Route the cable from the main power
switch through the cable gland, and con-
nect the wires to the terminal board (see
electrical diagram on next page).
N.B.: After making the connection ensure that the motor
turns in the direction indicated by the arrow on the fan
shroud (in the oven chamber).
terminal board
cable gland
1-3
1.5.1 Wiring diagram
1. INSTALLATION
LCG-241D/DP 208/240V 3Ph
F3
LN
R7
F1
R4
R5
R3
F2
R2
R1
18 19 20 21 22 23 24 25 26
M
3~
1234567891011121314151617
27 28 29 30
MOTOR
CONTACTOR
1
2
3
4
5
6
21
22
EVC
EVC
EVS
EVS
-X1
SLOW
SPEED
1
2
3
4
5
6
21
22
FAST
SPEED
1
2
3
4
5
6
21
22
SAFETY
THERMOSTAT
SAFETY
THERMOSTAT
P3
3a3
ELECTRIC CABINET
U1 V1 W1
U2 V2 W2
U1 U2
L1 L2
PE
DRAIN
PRESSURE
SWITCH
C
PS
WATER INLET
PRESSURESWITCH
C
PC
1
42
96
95
98
97
1
2
3
4
5
6
96
95
98
97
1
2
3
4
5
6
ELECTRIC CABINET PANEL SX
41 63 55 54
42
3
65
2
73 72 71
75
16 15
64 65 45 46 32 52 23 22 21 47 19 18
68
7
8
9
66
25 26 27
28 28
28
3131
40
11
49 50 51
56 57 58 59 60 61
53
62
39
14
48
24
38 37 36
44
43
76
12
95
4
1
EVG1
EVG2
P1
P2
1
P1
L
N
20 13
35
87
69 70
LAMP
PE
LAMP
PE
LAMP
PE
PANEL DX
74
F6 0.032A
34
77
78
67
-N1
A2
A1
F2 1A
A2
A1
A2
A1
F1 1A
PE
F3 0.5A
-K7
024
0 240
240
0 120
0
-K1
-Y2
-Y1
L1
L2
L3
-K2 -K3
-Q3
-E1
PE
-M1
-N2
-K6-K5
-S1
-Q1 -Q2
-E3 -E4
-Q3
-Y3
-K4
-T1
-H1-H2-H3
-E2
-T2
-EY3
FAN
MOTOR
WATER DRAIN
SOLENOID VALVE
WATER INLET
SOLENOID VALVE
POWER SUPPLY
TERMINAL BOARD
FUSE HOLDER
ELECTRONIC BOARD 240VAC
DRAIN
PROBE
CHAMBER
PROBE
CORE
PROBE
STB CHAMBER
DOOR SWITCH
FC FILTER
DOOR
MICRO-SWITCH
THERMOCOUPLE
GAS
SOLENOID
VALVE
IGNITION
PUSHBUTTON
TRANSFORMER
ELECTRIC IGNITION
1-4
1. INSTALLATION
1.6 Heat baffle
Fit the baffle to the oven base: secure it to the
rear by engaging the locking pin, and to the
front by means of a screw after inserting the
bracket flange in the slot on the internal fold of
the front panel.
-
2
-
9
8
10
11
12
13
14
15
16
2. FEATURES
2.1 Construction details
1) Flue outlet
2) Steam vent pipe
3) Adjustable foot
4) Drip tray
5) Ignition position
6) Burner start enable position
7) Stop position
8) Stand-by key
9) Alarms display
10) Cooking mode selection keys
11) Special function keys
12) Thermostat controls
13) Timer controls
14) Core temperature probe selector
15) Programming - memory storage section
*
16) Cooking START/ STOP key
*
only DP
LCG-241D
LCG-241DP
2
1
3
4
O
F
F
P
I
L
O
T
O
N
it
7
5
6
L
1
L
2
L
3N
1
A1
A2
10
16
U1
V1
W1
U2
V2
W2
77
7
F1
F2
1B
19
LC
L
U
L
U
10 9 8 7 6 5 4 3 2
1
12
21
2223
120V
N
L
F1
F2
R1
R2
R3
R4
R5
R7
F3
18
19
20
21
22
23 24
25
26
27
28
29
30
111213
15
16
17
14
6
4
5
3
24
25
18
9
8
2
A2
A2
A1
A1
1 - Terminal board
1B - Fuse carrier (F 0.5 A)
2 - Heating elements
3 - Motor contactor
4 - Drain solenoid valve
5 - Water inlet solenoid valve
6 - Inlet pressure switch
7 - Lighting = 2 x 25 W
8 - Heating element contactor
9 - Door microswitch
10 - Fan motor
12 - Electronic card
16 - Motor overload cutout
18 - Safety thermostat
19 - LC filter
21 - Oven temperature probe
22 - Food temperature probe
23 - Drain temperature probe
24 - Safety contactor
25 - Backup thermostat
208V3N
240V3N
WARNING: VOLTAGE BETWEEN L1 AND N MUST BE 120V
WARNING
Disconnect the electrical supply
by setting the main power switch
to OFF.
ELECTRICAL DIAGRAM
OFF
T
3. NOTES FOR CUSTOMER SERVICE1.6
3.1 Replacement of functional components and reset procedures
The above operations must be carried out by skilled and authorised personnel.
Disassemble only the specified side panels. Do not remove the rear panel.
Replacing light bulbs or the diffuser glass
- remove the rh side panel by unscrewing the relative
screws
- unscrew the screw and nut shown in the figure and
withdraw the lampholder support; replace the bulb
with a bulb of identical specifications.
- to remove the diffuser glass for replacement, unscrew
the other three nuts inside the lampholder and
withdraw the glass.
Replacing fuses
Remove the lh side panel;
- the plug-in type fuse holders are located at the side of the
terminal board; replace with rapid-acting fuses (see value on
electrical diagram).
Resetting overload cut-outs
Remove the lh side panel.
- The overload cut-out disconnects the power supply to the motor
in the presence of overheating due to overload; before pressing
the reset button, find and eliminate the cause of the overload.
Resetting the safety thermostat
The safety thermostat shuts down the oven
when internal temperature exceeds 572°F.
To restart the oven:
- Remove the lh side panel.
- Allow the oven to cool for about 10 minutes,
find and eliminate the cause of overheating
and then press the reset button.
- 3 -
4. STARTING
4.1 Operating gas
Check the data plate
to make sure the
appliance has been
tested for the type of
gas available.
4.2 Gas pressure check
Close the main gas valve!
- open the door placed;
- remove cap screw of the pressure test point and connect a
pressure gauge to this outlet;
- open the main gas valve and turn on the appliance at
maximum capacity (see "Starting");
- make sure the pressure lies within the limits indicated in the
table below.
After this check, remove the pressure gauge and close the pressure test point!
230V1N 50 Hz 400 W
Mod FCV61DM XXXXXXXXX
Mat
XXXXXXXXXX
Cat
G20-20 mbar 20 mbar 11 kW 1,16 m
3
/h
G31-50 mbar 50 mbar 11 kW 0,85 kg/h
G30-50 mbar 50 mbar 11 kW 0,87 kg/h
G25-20 mbar 20 mbar 11 kW 1,16 m
3
/h
G110-8 mbar 5,5 mbar 11 kW 2,84 m
3
/h
400V3N 50 Hz 400 W
400V3N 50 Hz 400 W
G120-8 mbar 5,5 mbar 11 kW 2,53 m
3
/h
G140-8 mbar 5,5 mbar 11 kW 2,96 m
3
/h
OFF
GAS
50
48
46
44
40
38
36
Gas type
Pressure in Inches Water Column
natural gas
propane
7" 4" 10"
11" 8" 13"
rated minim. maxim.
- 4 -
GAS
STOP
OFF
GAS
4. STARTING
4.3 Controls
4.4 Safety devices
A thermocouple device locks the gas outlet in case the flame is
extinguished. A further safety thermostat is released in case the oven is
overheated.
4.5 Pilot flame ignition
Press the control knob and turn it to the PILOT position. Press the knob
and light the pilot flame keeping the knob fully pressed for a few seconds.
Release the knob and check that the pilot flame stays on. If it goes out
repeat the lighting operations.
4.6 Ignition the main burner
Press the control knob and turn it to the ON position. The gas way to the
main burner is opened by powering the automatic shut-off valve.
4.7 Stand-by position
To maintain the main burner off with the pilot burner on, press and turn
the control knob to the PILOT position.
4.8 Turning off
Press and turn the control knob to the OFF position.
WARNING: WHEN YOU HAVE FINISHED USING THE OVEN,
CLOSE THE MAIN GAS SUPPLY VALVE AND SWITCH OFF THE
MAIN POWER SWITCH FOR AT LEAST FIVE MINUTES BEFORE
RELIGHTING.
IN LOWER COMPARTMENT
BURNER IGNITION CONSENT
MARK OF REFERENCE
O
F
F
P
I
L
O
T
O
N
it
it
O
F
F
P
I
L
O
T
O
N
- 4-1 -
INSTRUCTIONS FOR THE USER
09 II1999
39D0910
LCG-241D & LCG-241DP
1
7
2
3
5
6
8
4
Section A.
GENERAL INSTRUCTIONS
- 1 -
1. Contents
2. Hazards in the work environment
2.1 Fire
2.2 Accidents
2.3 Electricity
2.4 Gas
3. Correct use
3.1 Working in safety
3.2 What to do in the event of a malfunction
3.3 Prolonged period of non-use
3.4 Definitive deactivation of the equipment
4. Malfunctions
4.1 Problems, causes and remedies
5. Maintenance
5.1 Maintenance contract
5.1.1 User-serviceable parts
5.2 Advice
6. Cleaning
6.1 Cleaning of appliances
6.2 Cleaning of stainless steel
6.2.1 Ordinary daily maintenance
6.2.2 Precautions during use
6.2.3 Protecting the stainless steel
7. Observance of regulations
7.1 Standards and regulations
7.2 Liability
2.1 FIRE
Curtains, cloths, chopping-boards or other wooden objects must be kept a safe
distance from hobs and other heat sources; the same applies to vessels
containing alcohol, solvents or inflammable cleaning agents, etc. The risk of
fire in a kitchen is very high.
Fires usually start in a precise point and can be prevented from spreading if
panic is avoided. Hasty reactions may worsen the situation. Never use water to
extinguish an electrical fire; first disconnect the electrical power supply then
extinguish the fire using suitable materials or fire extinguishers.
2.2 ACCIDENTS
There is also a high risk of personal injury (burns, falls) in a commercial kitchen.
Make sure the handles of pans do not protrude from the hob, and frying pans
and other fryer equipment must not be left unattended at any time. Any oil or
grease spilled on the floor must be cleaned up immediately to prevent
slipping.
2.3 ELECTRICITY
The most serious hazards associated with electricity are those of fire
and electrocution.
Follow the safety instructions below:
• Electrical installations: all installation and maintenance should be
carried out by a qualified electrician in accordance with current safety
standards. The main switch must be easily accessible. Cables, plugs
and sockets must be kept in perfect condition.
• Safety: always turn off the main switch before cleaning or any other
operation on the appliance.
Never pull on a power supply cable to unplug an appliance from a
socket.
Do not attempt to repair a damaged cable with insulating tape or other
means, have the entire cable replaced by qualified personnel.
2.4 GAS
The smell of gas is a sign of a probable leak. In this event, close the main shut-off
valve, open doors and windows, and take care not to cause any sparks or
flames.
If you cannot identify the cause of the leak, call a qualified service engineer.
A high percentage of accidents happen because the gas appliances are not
checked regularly: gas appliances are only safe if they are kept in perfect
working order (see chapter 5).
Essential safety precautions when working with gas appliances
To light a gas burner, first bring the flame near to the burner and then turn on the gas.
It is important that the gas burns properly (blue flame) and that there are no restrictions in
the flueways, as these might give rise to dangerous emissions of carbon monoxide
fumes (which are even more hazardous than mains gas, because they are odourless
and give poisoning symptoms that may be confused with harmless disorders).
We strongly recommend the installation of electronic sensors by qualified personnel.
- 2 -
2. HAZARDS IN THE WORK ENVIRONMENT
Adhere scrupulously to the instructions in Section B and do not tamper with the appliance's
safety devices, as this would invalidate any warranty and release the manufacturer from all
liability.
The equipment may be utilised only for the specific uses for which it is intended (as indicated
in Section B).
Any other use is deemed improper and thus hazardous.
THE MANUFACTURER ACCEPTS NO LIABILITY FOR ANY DAMAGE, LOSS OR INJURY
DERIVING FROM INCORRECT INSTALLATION OR USE AND IN THIS CASE DOES NOT
GUARANTEE THE CORRECT OPERATING OF THE APPLIANCE.
3.1 WORKING IN SAFETY
Not to know or to underestimate the risks deriving from the incorrect or improper use of the
appliance can be very dangerous. It is important to adopt working habits in the daily use of the
appliances:
learn the correct use of the various appliances which comprise the
installation;
after each use, always make sure that all appliances are turned off and
then close the shut-off valve and/or turn off the main switch;
do not use inflammable cleaning agents and do not leave containers with these
substances near the appliance;
the appliance is intended for professional use and must be used by qualified
personnel only!
check the correct operation of the appliance every 6 months. On type B appliances, the
fume exhaust duct must also be checked.
Inexperience, negligence or haste may cause situations of emergency which otherwise could
have been avoided. Prevention is the first rule for working in safety. Ensure that the electrical
system is perfect order and that gas appliances are inspected regularly. Always think beforehand
of what you are about to do and how to do it, and act in such a way as to ensure your own safety
and that of your colleagues.
3.2 WHAT TO DO IN THE EVENT OF A MALFUNCTION
Do not attempt any repairs yourself. Turn off the main switch, gas shut-off valves,
water taps, etc. as applicable, and call a qualified service engineer.
We strongly recommend that you contact our Service Centre in your area, which
can provide the necessary expertise and equipment, and which maintains a stock
of original replacement parts.
3.3 PROLONGED PERIODS OF NON-USE
If the appliance is not to be used for a prolonged period, close the gas shut-off valve and/or turn
off the main switch. Clean the appliance thoroughly as indicated in Section B, and protect it
from dust with a cover allowing free air circulation.
3.4 DEFINITIVE DEACTIVATION OF THE EQUIPMENT
Seek assistance from qualified personnel.
- 3 -
3. CORRECT USE
- 4 -
4.1 Problems, causes and remedies
The guide below will help the User to rectify minor faults; in the event of any other problems,
contact the approved Service Centre, the only service centre authorised to repair the
appliance.
• SMELL OF GAS
This may be an occasional leak: Boiling water has extinguished a flame, but in this case the safety device
intervenes and locks the gas outlet before a dangerous gas concentration is reached in the room. Close the
gas cock and aerate the room. If this is not the cause, have the equipment checked by skilled personnel.
• THE PILOT FLAME DOES NOT IGNITE
Check that the ignition device (whether electric, piezoelectric or electronic)
functions correctly; try igniting the pilot flame with a match.
There may be air in the piping, especially after a period of non-use; in this case, repeat the ignition
operation, this time trying for a little longer.
• THE PILOT FLAME DOES NOT REMAIN LIT
The control knob is being released too soon, before the thermocouple has had time to reach operating
temperature. Repeat the ignition operation, but keep the knob pressed in for a little longer.
• THE PILOT FLAME IGNITES BUT THE BURNER REMAINS OFF
Check that thermostat control knob is turned to a temperature setting and activate the
ignition enabling device (if present).
If the gas flow is controlled by an electric or electronic system, make sure the system is
receiving electrical power (any displays or indicator lights must be lit).
• DEFECTIVE COMBUSTION (YELLOW FLAME)
This may be caused by dirt in the burner or by clogged smoke pipes. It may also be caused by
dripping condensate created by an obstruction or dirt in the flue.
Call a competent service engineer.
• MALFUNCTION OF ELECTRIC EQUIPMENT
This may be due to the absence of a supply phase (frequent tripping of the overload
cutout): check any fuses and replace if necessary.
If either the thermal-magnetic circuit breaker or residual current device (RCD) trips continuously, call an
authorised service engineer.
• PROBLEMS WITH WASHING EQUIPMENT
Poor washing results (dishwashing machine, vegetable washer, etc.) may be due
to the lack of a supply phase (see above) or to too little water pressure, in which
case a pressure boosting device must be installed. It may also be necessary to
install a water softener if white deosits are left on dishes after washing.
• INSUFFICIENT COOLING IN REFRIGERATING EQUIPMENT
This may be due to incorrect positioning (near to heat sources), or to excessive ice on
the evaporator (appliances without automatic defroster), in which case it will be
necessary to defrost manually
.
• INSUFFICIENT AIR SUCTION IN EXHAUSTING SYSTEMS
Ensure all grease filters are kept clean.
4. MALFUNCTIONS
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35

Lang LCG-241D User manual

Category
Microwaves
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI