Synesso MVP Owner's manual

Type
Owner's manual

This manual is also suitable for

1
5610 4th Ave S. / Seale, WA 98108—USA
Tel: +1 206 764 0600 / Fax: +1 206 764 0601
Ordering Parts: [email protected]
Informaon: [email protected]
www.synesso.com
MVP & MVP HYDRA
OWNERS MANUAL VERSION 2015.1
3 Group MVP
*ShownwithOPTIONAL
RedPowderCoatAccents
Lastupdate:Oct14,2015
2
TABLEOFCONTENTS
Introducon 3
SafetyWarnings 4
DepressurizingTanks,TankSafety 5
StartUpScreen,Serial#,SowareVer. 6
ListofToolsandSupplies 6
Warranty&WaterStandards 7
Installaon/installaonDiagram 8‐9
SidePanelRemoval 10
PlumbingRequirements 11
ElectricalRequirements 12
MVPHydraPackage&Installaon 13
StartupInstrucons 14
MVPHydraBypassSetup 15
MVP&MVPHydra,LastShowBrewed 15
Operaon 1618
Programming‐HandheldController 1930
MenuLevel1‐Operaons 1923
FactorySengs 20
BrewTemperature&Pressure 20
SteamTemperatureControl 21
HotWaterTap 22
AutoBackushingMachine 22
BrewErrorCodes 23
MenuLevel2‐Sengs 2430
SaveLockout 24
Programs,Acvate&Deacvate 24
Temperature,Fahrenheit&Celsius 25
LinePressureBoostSystem 25
BrewOsets 26
SteamOset 27
SystemClock 27


PowerSaveMode 28
ErrorLog 2930
ReturntoOperaons(Level1Menu) 30
Maintenance 3132
TroubleShoongGuide 3335






















3
PleaseWRITEyourSerialNumber&OsetInfor
maonhere.Thiscanbefoundonthe2nd&3rd
MenuLevelsoftheDisplayController.Havethis
availableBEFOREcallingforserviceortechnical
support.
S/N:________________________________
Theosetsforthismachineare:
BG1:_____°F/BG2:_____°F/BG3:_____°F
SteamTank:_____°F
Factory Contract Informaon:
Synesso™Inc.
56104thAveSouth
Seale,WA98108‐USA
Tel:+1.206.764.0600/Fax:+1.206.764.0601
Email:[email protected]
Web:www.synesso.com
Twier:@SynessoFactory
Instagram:Synesso_factory
INTRODUCTION
CongratulaonsonthepurchaseofyourSynesso™espressomachine.PleasereadthisOwner’sManualand
retainitinasafelocaonforfuturereference.Ifyouhaveanyquesonsaboutyourmachine,pleasecon
tactSynesso™andourknowledgeablestaffwillassistyou
Includedinthepackagewiththismachineyouwillndthefollowing:
 ThumbDrivecontainingtheOwner’sManual,MVPSeriesVideoandothertechnicaldocuments
 Pump/MotorCombinaon+hoses(3/8compressionngsonallhoses)
 8’Flexible¾”IDdrainhose+hoseclamp(aached)
 Fing,1/4”maleNPTx90°x3/8”Compression(ifnotCE/CTick)
 AccessoryPackage:Portalters(percustomerspecicaon),blindbasket,Synesso™3oz.(90ml)shot
glass,JoeGlo™cleaningkit,58.4mmtamper,4rubberlegpads
 ElectricalplugsareONLYincludedonCSACeredmachines(Canada).Forallothermachines,the
ownerofthemachinemustpurchaseanappropriateplugendfortheirmachine.Pleaseseetheinstal
laoninstruconsstarngonpage8formoreinformaon.
Serial Number
Yourespressomachinehasauniqueserialnumber,locatedontheleinnerframeofthemachine,just
underthedraintrayonaserialplate.Thenumbercanalsobereadonthedisplayduringstartup.Please
havethisserialnumberavailableforreferencewhencontacngthefactory.
ThismanualappliestoSynesso™models:MVPandMVPHydramachines.TheMVPmachinescanbecon
guredtooperateanygroupheadasmanual,manualwithaprogramandfullvolumetricwithaprogram
thatincludesadjustabletotalwatervolume.TheMVPHydramachineshaveanindividualpumpandmotor
pergroupheadandcomestandardwithBypasshardwareandaPressureRegulatorfor4StagePressure
Ramping.
4




Theconductorsofthepowersupplycordare
marked“L1”,“L2”fortheungrounded(“hot”)
supplyconductorsand“G”foranequipment
groundinglead.
Warning:RiskofFire.UseULListedGrounding
TypePlugratefor220Volts,______Amperes,
_______Phase,#______Wire.PlugtobeSelected
andInstalledonly
byQualiedServicePersonnel.
Electrical
WARNING: Disconnectfrom
powersupplybeforeservicing
AVERTISSEMENT: Couper
l’alimentaonavantl’entreen
etledepannage.
California
only:
CALIFORNIA PROPOSITION 65 WARNING
WARNING: Thisproductcontainschemi
calsknowntotheStateofCaliforniato
causecancerandbirthdefectsorother
reproducveharm.(Californialawrequire
thiswarningtobegiventocustomersin
theStateofCalifornia)
Electrical
Box:
This equipment is to be installed to
comply with the applicable federal,
state or local plumbing codes.
Underdrain
tray
MaterialsinformaonforSynesso™machines:
 Allstainlesssteelcomingintocontactwiththewatersupplyis300series
 AllbrassngsarelowleadpertheCA360specicaonsorbeer
 Allelectronicdevicesareleadfree
 Allgasketsaremadefromfoodcontactsafematerial
TestInformaon
 Brew(coee)tanksarehydrostacallytestedto375psi
 Steamtanksarepressuretestedto75psi
 Theelectricalsystemissubjecttoanelectricalwithstandtestof:
1.20kvac,at5.00mA,for1second
IMPORTANTInformaonforSynesso™EspressoMachines:DISCONNECT FROM POWER BEFORE SERVICING.
 Readtheenremanualbeforeoperangthismachine.
 Steamandcondensaonfromthesteamwanddischargeareveryhotandmaycauseburns.
 Thesteamwandpsandbasesbecomehotduringuse:donottouchthesesurfaces.
 Coverthesteamwandporsubmergeinalledpitchertosafelydivertthesteambeforeopeningthe
steamvalve.
 Neverremovethesteamwandfromtheproductthatisbeingheatedwhenthevalveisopen.
 Neverremovetheportalterfromthemachineduringtheacvebrewingprocess.
 Keepwaterandmoistureawayfromanyelectricaldeviceorlivepower.
 Steamtankwaterisheatedto260°F(126°C)ormore;Usecauonnearsteamtank.
 Thebrewgroupsdeliverwaterashotas210°F(99°C).Avoidexposuretothiswater.
 Thehotwatermixvalvecanbeadjustedtodeliverwaterashotas212°F(100°C),whichcancausesevere
burns:pleaseusecauonwhenacvangthiswatersource.
Safety Label Locaons:
Synesso™complieswithULregulaonsbyposngthefollowinglabelsonitsmachines:
SAFETYWARNINGS
5
BREW&STEAMTANKSAFETY
Safety Precauons:
Espressomachineshavenumerouspotenalhazards,anditisofparamountimportancetoSynesso™that
peopleservicingourmachinestakeallnecessaryprecauonstoensuretheirpersonalsafety.Whenwork
ingonthemachine’sboilers(unlessotherwiseinstructedinthedirecons):
 Turnthemachineoffandshutofftheincomingwatersupply.
 Depressurizetheboilersasshownbelow.
Whenworkingonanyelectricalwiring(unlesscheckingvoltageoramperagereadingsorotherwisein
structedinthedirecons)ensurethatthemachineisswitchedoffattheelectricalboxandthemachineis
unplugged.
Depressurizing the Steam Tank:
1.Turnofftheelementcircuit
breakerlocatedunderthemachine
2.Openthesteamvalvebymoving
thesteamactuatorleverforward
3.Thesteamtankisdepres
surizedwhenthesteamgauge
readszero.Note:thesteam
gaugeisrated@060psi
Depressurizing the Brew Tanks:
1.Turnofftheelementcircuit
breakerlocatedunderthemachine.
2.Alsoturnoffthewatersupplyto
themachine.
4.Thebrewtanksaredepressur
izedoncethepressuregauge
readszero.Notethebrew
gaugesareratedat0300psi
3.Inthesecondlevelmenu,
changethebrewvalvesfrom
“Normal”to“ON”thiswill
bleedthepressure.
NormaltoOn
6
RECOMMENDEDTOOLS&SUPPLIES
 MulMeterreadsvolts,ampsandohms
(TheFlukeT5600isrecommended)
 HeatShrinkGunorTorch
 VacuumwithaHose
 CompressedAir
 DescalerCitricAcid
 Flashlight
 BoxKnife
 ThreadSealantRedandBlueLocte
 FoodGradeGrease(SuperLube)1.8600
 TubeBenderfor1/4”,5/16”,and3/8”Tube
 FlareTool‐45°
 TubeCuer
 BrassBristleWireBrush
 3/8”DriveSocketWrenchwith7/16”,1/2”
and9/16”“DeepSockets”
 HammerMediumSizeBallPeen
 WireStripper/Crimper
 SmallPunchandChisel
 SmallFilesRoundandTriangular
 PicksStraightandCurved,anIcePickisgreatfor
replacingportaltergaskets
 Dies:1/8”NPT,1/4”NPT,and1/8”BSPP
 Taps:832,10‐32,3/816,andM6x1
boomingTap
 AllenWrenches:3/32”,1/8”,9/64”,5/32,3/16”,
1/4”(steamvalveseat)
 Wrenches:2x11/32,1/4,5/16,3/8,2x7/16,1/2,
2x9/16,5/8,11/16,3/4,12mm&17mm
 Adjustablewrenches:Mediumsize11/4”
openingandSmallforghtspots
 Pliers:ChannelLock,StandardpliersandSide
Cuers
 PhilipsHeadScrewdrivers:#2short,#2longand
#1
 FlatHeadScrewdrivers:#2short,#2medium
length,#1medium,#0medium
 Alargeatheadscrewdriver(orsmallatnail
puller)touseasaprybarorwedge.
 Penandpaper
Tools and recommended items required to fully diagnose, service and maintain
Synesso espresso machines.
STARTUPSCREEN
Understandingtheinformaondisplayedintheserialnumber.i.e.:301142030
3‐isthenumberofgroupsonthismachine(thisisa3groupmachine)
01‐isthemonthiswasbuilt(Janis01)
14‐istheyeariswasbuilt(14istheyear2014)&2030isthemachinesequencenumber
Whencyclingthepoweron,
thisscreenisshownmomen
tarily.Itdisplaysyoursoware
versionandyourserialnumber.
7
Limited OneYear Non Wearing Parts Warranty
Synesso,Incand/oryourDistributorwarrantstotheoriginalpurchaserthatSynessoespressomachinesare
freefromdefectsinmaterialsandworkmanshipundernormaluseandservicefortheperiodcommencing
uponthedateofshippingandconnuingfor12monthsfromtheoriginaldateofshipment.Synessowill
makeagoodfaitheortforpromptcorreconorotheradjustmentwithrespecttoanynonwearingpart
thatprovestobedefecvewithinthelimitedwarrantyperiod.ThisLimitedWarrantyiscondionalupon
properuseofthemachinebythepurchaser.
ThisLimitedWarrantydoesnotcoverdefectsordamageresulngfrom:accident,misuse,abuse,shipping
damage,neglect,unusualphysical,electricalorelectromechanicalstress,unauthorizedcustomermodica
onsorimproperwaterltraon.
Proper water ltraon and regular lter changes are a requirement to keep your factory warranty valid
and your machine funconing properly.Itishighlyrecommendedthatyoucontactaprofessionalwater
ltraonspecialistinyourareaandhaveyourwatertestedtodeterminetheproperltraonsystem.Itis
importanttonotethatmanymunicipalieschangetheirwatersourcesthroughouttheyear,soaddional
watertestsmaybecomenecessary.
Water Standards to keep your warranty valid:
In Synesso’s experience, Everpure Claris and Cirqua formulator systems can produce a re
sult that can damage the Synesso stainless steel tanks. Use of either system is highly dis
couraged and will void the water related parts of the machine warranty.
AnypartwhichisdeterminedtobedefecveinmaterialsorworkmanshipshouldbereturnedtoSynessoor
toanauthorizedservicelocaon,shippingcostsprepaid,asSynessodesignates.Synessomayrepairorre
placetheproductorpartwithneworfactoryrefurbishedequipmentatSynesso’ssolediscre
on.Ifthe
productorpartisdeterminedtobedefecveandincompliancewiththeLimitedWarrantycondions,the
replacementpartorproductwillbereturnedtothepurchaserwithshippingprepaid**.
Manyjurisdiconshavecodesandregulaonsgoverningsales,construcon,installaon,and/oruseof
productsforcertainpurposes,whichmayvaryfromareatoarea.WhileSynessoaemptstoassurethatits
productscomplywithsuchcodes,itcannotguaranteecomplianceandcannotberesponsibleforhowthe
productisusedorinstalled.
TotalDissolvedSolids(TDS) 30to200
ppm(partspermillion)
TotalHardness‐inppm Lessthan85ppm
TotalHardnessingrains 3to5grains(divideppmby17.1togetgrains)
pH 6.5pHto7.5pH
Chloride 515ppmanyChloridescanbecorrosiveandharmful
TotalAlkalinity Lessthan100ppm
Chlorine 0ppm
Iron 0ppm
WARRANTY&WATERSTANDARDS
8
WARRANTY&WATERSTANDARDS
Synesso’sliabilityislimitedtothepurchasepriceoftheproductandshallnotbeheldliablefordamagesthat
extendbeyondtheproductitself.Synesso’sliabilityofconsequenal,incidentaldamages,indirectordirect
damagesforpersonalinjury,inabilitytoproperlyusethisproduct,lossofbusinessprotsorinterruponto
businessisexpresslydisclaimed.
**RegardingequipmentsoldorresidingoutsidetheUnitedStates:purchasermayberequiredtopayforthe
shippingandassociatedcostsforwarrantyparts,repairsandservices.Pleasecontactyourlocaldistributorto
resolvetheissueregionally,ifpossible.
INSTALLATION
To maintain the 1 year warranty, an authorized or cered espresso service representave
must perform the installaon of this espresso machine.
SitePreparaon‐SeeDiagramp.9
Themachinemustbeplacedonalevelhorizontalsurfacethatcanbeeasilycleanedandiscapableofsus
tainingaminimumof300lbs.
Thecountertoprequiresadepthof28”,whichprovidesaminimumclearanceof1”behindand3”
infront
ofthemachine.
Makea2½”minimumdiameterholethroughthecountertoplocated4”fromtherearand7”fromtheright
sideofthemachine.Thehoses,draintube,andelectricallineswillallpassthroughthishole.
A3/8”min.diametercoldwatersupplylinefromthelterwithashutoffvalveisrequiredwithin5’ofthe
machine.Thevalveshouldbeeasilyaccessedformachineservice.
Themachinesupplyhoseandpumpngsare3/8”tubecompressionngs.
Aproperwaterltraonorsoeningsystemmustbe
installedontheincomingwatersupply.Watertreat
mentrequirementswillvary,anditisimportanttouseasystemdesignedtomatchtheneedsofyourspe
cicarea.Waterltraonsystemsrequireperiodicmaintenance,includingcartridgeorlterreplacement.
Properltraonandserviceisvitaltothefunconofthemachineandthequalityoftheespressoserved.
Followtheinstruconsprovidedbyyourwatertreatmentsystemforproperinstallaon.
Note:Improperwaterltraoncanresultinseveredamagetothemachineincludingscaledepositsandcor
rosion.DAMAGE CAUSED BY IMPROPER WATER TREATMENT WILL NOT BE COVERED BY THE MACHINE
WARRANTY. Seepage7.
Theremustbeadequateroomunderthecountertolocateeachmotorandpump.Thepumpsmustbeeasily
accessibleforadjustmentandmotorsmusthaveaminimumof3”clearanceonallsidesforairow.
Aoordrainorsinkmustbeavailable.Thebest
locaonisdirectlyunderthemachine.The3/4”drainhose
shoulddescendasvercallyaspossibleforopmaldrainage.Anairgapisrequiredbetweentheendofthe
drainhoseandthehighestwaterposionofacloggeddrain.Thisistopreventthepossibilityofdrainwater
backingupintothemachine.
9
INSTALLATION
10
MVP&MVPHydra‐2PieceSidePanels
Thissidepanelisshownwiththetrimplatesremoved,todisplaythewaythelowerpanelinterlockswith
theupperpanel.
WhenremovingtheLowerSidePanelfromtheespressomachine:
 Loosenthe2sidepanelmounngbolts,butdonotremove.
 RemovetheThumbScrewfromthedraintray
 Pushthepaneltothebackofthemachinewhileliingslightlyup
Thisallowstheusereasyaccesstothedrainbox&allowsthetechnicianeasyaccesstoallwatercontrol
valvesonthewaterinlet(right)sideandtothelevelprobesandthermalswitchesontheleside.
Forthetechniciantoaccessthesteamvalve,theUpperPanelmustberemoved.
WhenremovingtheUpperPanelfromtheespressomachine:
 Removethe2sidepanelmounngboltscompletely.
 Eachboltisthreadedintoaplatefastenerinsidetheframe.Be careful not to lose the fasteners.
 TheSafariRackissuspendedby,butnotthreadedonto,shortboltsoneachsidepanel.*The Safari
Rack needs to be supported while removing the Upper Panel.
11
PLUMBINGREQUIREMENTS
Thisequipmentmustbeinstalledtocomplywiththeapplicablefederal,stateorlocalplumbingcodes.
WATERTREATMENTISREQUIREDTOPRESERVETHEFULLMACHINEWARRANTY.Pleaseensurethatthe
incomingwatercomplieswiththewarrantyrequirementslistedonpage7.
Usingtheprovidedstainlesssteelbraidedhose,connectthepump
totheshutoffvalveonthelteredcold
waterline.Fingsonthehosesandpumpsare3/8”tubecompression.ThreadsealantorTeontapeis
notnecessary.Makeconneconssnug,butdonotoverghten.
TurnincomingwaterONandcheckforleaks.
Synesso™machinesrequirea
minimumof50PSI(3.5bar)oflinepressureat30gal(120L)perhourtohave
theautollsystem,forthesteamtankfunconingproperly.Pleaseensurethattheincomingwatermeets
thisrequirementorcontactSynesso™foralternavemethodsofboosngwaterpressure.
NOTE:Synesso™sellsa“Eurohose”adaptorhoseandng(partnumberis1.5020)whichconvertsfroma
3/8”tubengtoapipeng,suitableformostnonUSplumbing.Pleaserefertothepicturebelowto
idenfythedierencesbetweenthestandardandEurostylengsandhoses.
1/4”NPT
3/8”TubeCompression
3/8”BSPPipe
Standard Fing #1.5620
Standard Hoses
48” #1.5060
84” #1.5070
Euro Hose #1.5010
Euro Fing #1.5000
(Euro Assembly #1.5020)
12
ELECTRICALREQUIREMENTS
AllSynesso™machinesareratedtooperateon220vACwitha50or60Hzfrequency,singlephase.Machines
willoperatebetween208vand240v.
Listedamprangsareallmeasuredat220v.Incorrectvoltagecancausemalfunconordamagetothema
chine.
Anelectricalsocketandmatchingplug,ratedatthepropervoltageandamperagearerequiredwithinthree
feetofthemachine.PlugendsareNOTincludedwiththemachineunlessrequiredbyCSAorothercerca
on.
Aachtheplugendpermanufacturer’sinstrucons.
Makesure
thattheredelectronicsswitchandtheheangelementbreakeronthefrontoftheelectricalbox
areintheOFFposion,thenplugthepowercordintothereceptacle.
OPTIONAL:Ifrecoverymeisslow,installanInLineBuckBoosttransformertoincreasevoltagebelow208v
toopmizemachinerecoveryme.Buckboosttransformerscomeindierentsizes.Pleasechoosetheap
propriateoneforyourmachineifrequired.1and2GroupMachinesrequirea1.0KVAtransformer,3Group
Machinesrequirea1.5KVAtransformer.
SPECIAL ELECTRICAL INFORMATION FOR EMCCOMPLIANT MACHINES
(CTICKFORAUSTRALIA,CEFOREUROPEANDOTHERLOCATIONS)
TocomplywithEMC(ElectromagnecCompability)regulaons,Synesso™isrequiredtoinstallacapacitor
intheelectronicsboxacrossthemainpowerIN.To avoid an electric shock from the charge held in the ca
pacitor, unplug the cord, taking care to NOT touch the metal prongs on the plug end. Turn the electronics
ON/OFF red rocker switch to the ON posion and wait a few seconds unl the red switch “goes dark.” At
that point, the electrical charge has dissipated.
North American Wire Color
Green Ground GreenandYellow Ground(Earth)
White 110vLine1 Brown 220v
Black 110vLine
2 Blue Neutral
Worldwide Wire Color
Model CordPlugRang(ULListed) MachineMaxAmpDraw
2GroupMVP 30amp 28amp
3GroupMVP 50amp 36amp
1GroupMVPHydra 20amp 16amp
2GroupMVPHydra 30amp 30amp
3GroupMVPHydra 50amp 40amp
13
MVPHYDRAPACKAGEREQUIREMENTS&INSTALLATION
MVP Hydra Installaon Requirements:
Electrical:
TheHydrapackagehasaslightlygreaterampdrawthanthesinglepumpmachines;pleasenotethemax
ampdrawsandplanyourelectricalinstallaonaccordingly.Seetableonpage12.
Eachpumpmotorhasadisnctcolorassociaon,whichisindicatedthroughoutthemachinebycolored
wiresandzipes.Thecolorsareasfollows:
 Group1:Grey
 Group2:Purple
 Group3:Brown
 Waterinletforthesteamtank:Pink
Whereverthesecolorsareseen,itiscricalforpropermachinefunconthattheyarematchedupcorrect
ly(greytogrey,etc.)forbothelectricalandplumbingsystems.
Plumbing:
Hydrapackagesrequireoneincomingwatersourcelikesinglepumpmachines.The
waterpassesthrougha
manifold(commonlypartofthelinepressureregulator)andisdistributedtoeachpump.Onceagain,fol
lowthecolorcodingforproperinstallaonofthehosesfromtheoutputofeachpumptothemachine.
Pressure Regulator Plumbing & Bypass Box Wiring:
Pumpcordinstallaon:Insertthecolorcodedpumpcableintotheopeningofthematchingbypassboxand
aachthewirestotheterminalasshowninthepictureabove:greenwiresstackedonthegroundbolt,white
towhite/red,blacktoblack/blue,connectthebulletconnectors.
Pressureregulator:Usedtoachievethestage1lowpressurepreinfusion.Itissetandtestedat50psiinthe
Synesso™factory.Thispressuresengcanbeloweredifdesired,but50psiisthemaximumoutputpressure.
Toadjustthepressureregulator,rstloosenthenutonthethreadedpost,
thenturnthepostcounter
clockwisetodecreasepressure.
PressureRegulator
BypassBox
Pink
14
STARTUP
StartUp Instrucons
1.Tollthemachine,connectthewaterlines,connectthedrainhoseandturnthewaterON.
2.SwitchtheredelectronicsOn/OffswitchtoON.Thisacvatesthemachine’swaterautollfeaturefor
thesteamtankandtheelectronics,butNOTtheheangelements.
3.Thewaterlevelsightglassforthesteamtankislocatedontherightsideofthemachine.Asthetanklls,
thewaterlevelwillriseinthesightglassandwillautomacallystopwhenthepresetlevelisreached.
4.Bleedthegroupheadsofair:
 HoldeachbrewgrouphandleleunlthecorrespondingdisplayreadsM:shieachgroupheadhandle
lemomentarily,(seepicturesbelow)allowthegrouptorununlthereisasteadyowofwater.Shi
eachgroupheadrighttoturno.
5.Waitunlthesteamtankhasstoppedllingandthelevelinthesightglassreadsatleast½full.Turnthe
heangelementbreakertotheONor(1)posion.Alltheheang elements(brewandsteam)arenowac‐
vated.
6.Toadjustthepumppressure,acvatethepumpbyshiingthebrewgrouphandlemomentarilyletwo
mesonMVPandthreemesonMVPHydra.
7.Locateandreadthepumppressure/brewgaugelocatedtotherightoftherightmostgrouponMVPs
andtotherightofeachgrouponMVPHydras.
8.Setthepumppressureto9Bar:
 Locatethepumpadjusngscrewontherightsideofthebrasspumphousing.
 Loosenthelocknutandturnthescrewwithascrewdriver:
 ClockwisetoINCREASEpressure
 CounterclockwisetoDECREASEpressure
 Oncethedesiredpressureisreached,reghtenthelocknut.
9.Pleaseallowatleast30minutesof“warmup”mebeforeusingyourSynesso™espressomachineto
brewshotsorsteammilk.Thesteamgauge(thelehandgauge)shouldreadaminimumof1.1Bar.
CenterPosion‐AtRest ShiLe‐StartorAdvanceShiRight‐Offor
HoldLe‐changesMtoMPtoVPSelectBrewProgram
15
MVPHYDRABYPASSSETUP
PinValve
Pump Bypass: WiththebrewgroupinMmode,turntheassociatedbrew
groupactuatormomentarilytothele.Adjusttheregulatortocontrolpre
infusepressure.Turnletwiceinarowandadjustthepumppressure
(typically9bar.)Finally,turnleoncemoreandadjustbypasspressure
usingthepinvalveatthepump.Adjusttotaste(factorysengis7bar.)
Thepreinfusionmeandrampup,orbypass,me
aresetontheTemperatureControlscreenofthe
displaybyfollowingthedireconsonpages2021.
Pressthebuonnexttothelinetobeadjustedand
usetheupanddownarrowstoadjustthesetme.
Withthesesengsinplace,youcantastetheeectsofpressurerampingappliedtoeachshot.Theshotbe
ginswithpreinfusion.Lowpressurewatersaturatesthepuck,swellingittoreducechanneling.Aerthepre
infusemehaselapsed,rampup(bypass)begins.Thebypasssystemcreatesaslowriseinwaterpressure
byparallydiverngwaterawayfromthebrewgroup.Aertherampupmeends,thebypassclosesanda
brewpressure(9bar)stagebegins.Rampdownreturnstobypasspressure.WheninMorMPmode,theop
eratorentersrampdownbymovingthegrouptopactuatormomentarilytothele.Volumetricgroupscan
beprogrammedtoautomacallybeginrampdownatasetpercentageoftheshotasdescribedonpage20.
MVP&MVPHYDRAINTRODUCTION
TheMVPHydraisamachinemodelwithapumpandmotorforeachgrouphead.TheMVPHydrahasinter
nalplumbingandwiringtoaccommodateseparateanddisnctpressuresineachbrewgroup.Incontrast,
anMVPhasasinglepumpandmotorfortheenremachine.Havingindividualpumpsandmotorsallows
theoperatortocontrolbrewingpressureateachgrouphead,andeachbrewgroupfunconsindependently
withoutaecngthepressureattheothergroups.
MVPHydragroupscanfunconinManualmode(M)withfullmanualcontrol,inManualProgram
mode
(MP)withmedpreinfusionandpressurerampup,orinVolumetricProgrammode(VP)withprogrammed
pressureramping.Anygroupheadcanbechangedontheytoanyconguraonatanyme.
Last Shot Brewed:
TheMVPandMVPHydrahaveastoragefeaturewherethelastbrewingfunconisstoredinatemporary
memory.Thisappliestoanybrewingfuncon.Ifyouquicklypurgeascreen,thiswillbestoredasthelast
shotbrewed.Ifyoumanuallybrewanespressothatisperfect,thisisthelastshotbrewed.Thefollowing
funconsdonotchangethememoryofthelastshotbrewed:
 Turningonsavemode(holdanybrewgrouphandlerightfor2.5seconds)
 Shiingthruthe6availableprograms(momentarypressesofthebrewgrouphandletotheright)
 Saving(momentarilypressingthebrewgrouphandlelefromwithinsavemode)
 Savingagaintoaddionalprogramlocaons,onthesame,ordierentgroups
 Exingsavemode(holdanybrewgrouphandlerightfor2.5seconds)
 ShiingbetweenprogramsM,MP,VP,byholdingthehandleonthedesiredbrewgrouple
Whenarunninggroupisstopped,theparametersarestored.Aershotparametersaresavedtheycanbe
viewedandalteredonthehandheldcontroller.Anyalteraonsaresavedasnew
shotparameters.
16
OPERATION
Prepare a Portalter
1.Forbestresults,usefreshcoee.Groundcoeeshouldbebrewedassoonaspossibleaergrinding.
2.Selectthecorrectspoutandbasketconguraon.Single,doubleandboomlessportaltersareavailable
throughSynesso™.Thesinglespoutportalterisusedwithasingle(7g)baskettobrewasingleshot.The
doublespoutedorboomlessportalterscanbeusedwithdouble(14g)ortriple(18gor21g)basketsto
brewtriple,double,or2singleshotsofespresso.
3.Filltheportalterbasketjustabovelevelandwipeofftheexcess.
4.Pressstraightdownevenlyontopofthegroundswiththetamper.
NOTE:Whennotinuse,keeptheportalterengagedinthegroupheadtokeepitwarm.
Espresso Brewing
1.Grindadoseofcoeeappropriatetothebasketyouwillbeusing.
2.Dispenseintotheportalterbasket.
3.Levelthemoundandcompressusingatamper.(Atamperissuppliedwiththemachine.)
4.Engagetheportalterintothebrewgroupthathasthecorrecttemperaturesengforthisespressoroast
andpullrmlytotherighttosettheseal.
HoldhandleLEFTtochangetheOperaonModefromM(Manual)toMP(ManualProgram)toVP
(VolumetricProgram).
M Manual
5.Preinfusethecoeepuckby
momentarilyshiingthebrewgrouple.Thisallowslinepressuretosatu
ratethepuck.
6.Whenadripshowsatthespout(oronthebasketifboomless,)momentarilyshithebrewgrouple
againtoadvancetheprocess.Repeattoconnueadvancingthruthe
brewingprocessunlcomplete.
7.Youcanendtheshotbymomentarilyshiingthegroupcaprightatanymewhilebrewing.
Ifbrewinginmanualprogrammodeconnuetostep8(ManualProgram)
MP Manual Program
8.ManualProgramallowsametobesetforpreinfusion
(andalsoforrampuponMVPHydramodels.)At
thecompleonofthesetmethenextstagebeginsautomacally.If“0”isselectedfortheamountofme
thenthestagewillbeskipped.
9.Whentheprocesshasadvancedtofullpressurebrew(9bar)theoperatorshistothenextbrewstage
17
OPERATION
manuallyorendsthebrewingprocessmanually.
VP Volumetric Program
5.Selectaprogramtorunbymomentarilyshiingthecorrespondinggroupheadright,thiswillshithrough
theprogramsdisplayedontheshotmer.Therearesixtochoosefrom.Somemaybeturnedo,andthere
forenotdisplayed.
6.Checktheprogramonthehandheldcontroller.Pressthedownarrowtomovetothecorresponding
group.Theprogramnumberandpressuremesaredisplayedontherstscreen,andthepercentageofshot
brewedandtotalwatercountonthenextscreen.Seepages20‐21.
7.Theshotwillautomacallyendoncethesettotalwatercounthasbeenregistered.
BrewPressureGraph
PreinfuseBar RampUpBar BrewPressureBar RampDownBar
DisplayFuncons
ShiLEFTtoSAVEto
Program5
SAVELockoutisON
SteamTank,LowWater
LevelorLowFlowError
6ProgramsShown.Onlytheselected
programdisplayswheninuse.
MVPBrewPressureGraph.
5MinuteTimeOutEr
rororLowFlowError
18
OPERATION
Milk Steaming
1.Fillthepitcherhalfwaywithfresh,coldmilk.Smallerpitchersarerecommendedfordrinksizeslessthan
10oz.steamed,unusedmilkshouldbediscarded.
2.Condensaoncancollectinsidethewand.Acvatethesteamhandletoblowthewandclearbefore
steamingmilk.
3.Insertthep
ofthesteamwanddeepintothemilkpitcher.Thiswillpreventmilkfromsplashingoncethe
steamisturnedon.
4.Openthesteamvalvebypullingthehandletowardsyou.
5.Placeonehandonthesideofthesteampitchertofeeltherisingtemperatureofthemilk.
6.Asthemilkagitatesandheats,lowerthepitchertokeepthepofthesteamwandclosertothesurface.
Allowthesteamjetstopushsomeairbeneaththesurface,thenraisethepitchertolowerthepofthe
wanddeeperintothemilk.Thiswillconnuetheheangprocessandminimizefurtherfoaming.Donot
touchthesteamwandtotheboomofthemilkpitcher;thiscancreateaninaccuratetemperaturemeas
urement.
7.Heatmilktoapproximately150Fto170F(65°Cto76°C).Ifyouareusingyourhandtohelpdeterminethe
temperature,itwillfeelaboutashotasyoucanstandwithoutburningyourself.Milkthermometersarealso
anexcellentwaytodeterminethetemperatureofthemilk.
Cauon: Do not overheat the milk and scald it. Scalded milk should not be used.
8.Removethewandfromthemilk,purgewithsteam,andwipecleanimmediatelyaereachuse.
NOTE: AlthoughSynesso™steamwandsaremadewithaproprietarydoublewalledprocessthathelpsto
keeptheouterwallcooler,thepandbasecanbecomeveryhotandcauonmustbeused.
NOTE: WholeMilk,2%,1%,NonFat,SoyMilk,RiceMilkandothermilktypeproducts
mayrequiredierent
techniquestofoamproperly.Ingeneral,thehigherthefatcontent,theeasieritistosteam.
19
PROGRAMMING
ThisprogrammingseconappliestoallMVPSynesso™machines.MVPmachineshaveahandheld(wired)
controller,picturedbelow,toallowtheusertocomfortablyviewandchangethemachinesengs.
To change sengs on these screens, rst press the line buon on the le side of the display associated
with the seng you wish to change. The value will ash once selected. Press the up or down buons unl
the desired value is displayed. Press the line buon again to conrm the change. The value will stop ash
ing. Use this procedure to change any variables in the controller menus.
Thetoplineofeveryscreenindicatesthetle.Inthiscase,TemperatureOverview.
You can return to this screen at any me by pressing the home buon at the top right of the controller.
Themachinewillalsoreturntothisscreenautomacallyaerashortme.
Lines2,3,and4maycontaininformaonorsengs,manyofwhichcanbechangedbytheoperator.This
screenprovidesthe
currenttemperaturesforeachbrewgroupalongwiththesteamtank.Themostrecent
errorwillalsobeshowninthelowerrightcorner.Nosengscanbechangedonthisscreen.
Insomecircumstances,numerictemperatureswillnotbeshown.Ifatankisreading‘LOW’,thisindicates
that
tankisbelowthetemperatureprobe’seecverangeofmeasurement(170F270F/76.6C132.2C).
Readingsabovetheeecverangewillshowas‘HIGH’.
Theprogrammabletemperaturerangeforabrewgroupisfrom180F(82.2C)upto220F(104.4C).Thefacto
rysettemperatureis
203F(95C).Tochangebrewgroupsettemperatures,refertopage20.
Thesteamtankissetbythefactorytoadefaultsengof250F(121.1C).Tochangethistemperature,see
page21.
The[OK]ontherighthandsideofline4isindicangthattherehavebeennoerrorsdetectedbythecontrol
system.If,inplaceofthe[OK]youndanerrorcode(EX:STLW01),refertotheErrorLogcodesonpage23.
Tocycletothenextdisplayscreen,pressthedownarrowbuon.(Youmaypresstheuparrowinstead
to
travelbacktothepreviousscreen.)
20
PROGRAMMING
Line1oftherstbrewgroupcontrolscreenindicatesthecurrenttemperatureofthebrewtankasmeasured
byitsprobe.Oncethistemperaturereachesthesetpoint,itwillconnuouslycycleupanddownbysmall
incrementsastheelectronicsbalancethetemperature.Thislinealsoindicates
theacveprogram(PRG1in
thiscase).Changingtheacveprogramwillupdatethesengsonlinesbelow.
Line2isindicangthesetpointof202.0F(94.4C).
Line3indicatesthelengthofmepreinfusionissetforinthecurrentprogram.WhenstarngashotinMP
orVPmode,preinfusionwillallowlinepressurewatertosoakthepuckforaslongasindicatedbeforemov
ingontothenextbrewphase.Sengthepreinfusionmedownto0.0secondswillskipthepreinfusion
phaseinMP
andVPmodes.Onesteplowerthan0.0isthe“MAN”seng,whichwillrequiretheoperatorto
exitthepreinfusionphasemanuallyinMPmode,andwillskippreinfusioninVPmode.
Line4indicatesthelengthmesetfortherampupphaseinthecurrent
program.ThisoponwillONLYbe
visibleonMVPHydramodels.Rampupmebeginsoncethepreinfusionstagehasnished.
Tocycletothenextdisplayscreen,pressthedownbuon.
Menu Level 1: Group 1, Program 1
Factory Sengs:
Thefactorysengsforyourmachineareasfollows:
BrewGroupTemperature 203°F
SteamTankTemperature 250°F
BrewMode M(Manual)
RightHoldSaveLockout Locked
EnabledPrograms 1&2Enabled(36Disabled)
TemperatureUnits Fahrenheit
Program1:Program2:
PreInfusion 4seconds PreInfusion 4seconds
RampUp 2seconds RampUp 2seconds
RampDown 92%RampDown 92%
TotalWaterCount 280TotalWaterCount 380
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35

Synesso MVP Owner's manual

Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI