  • Hello! I'm here to assist you with your Kodak & Pylontech setup. I've reviewed this setup guide, which covers everything from wiring to BMS communication. It also details crucial settings, such as voltage limits, and includes troubleshooting tips. Feel free to ask me any questions you have about the information in this document.
  • What does a flashing battery icon indicate?
    What is the recommended discharge voltage limit?
    What is the recommended charge voltage limit?
    What is the most common communication error?
Kodak & Pylontech Setup Guide
Contact SegenSolar (PTY) Ltd | Email: info@segensolar.co.za | Tel: 011 085 2600
Contact SegenSolar (PTY) Ltd | Email: [email protected] | Tel: 011 085 2600
WIRING EXAMPLE
SOLAR POWER
GENERATOR
UTILITY
OR
HOME APPLIANCES
BATTERY POWER
AC Protection Box
Fuses
DC Protection Box
INVERTER
AC Protection Box
Power Connections
Battery cable click here to view on the portal CAB-PK-PYLON
To inverter
BMS + and - Inverter Battery Terminal
Battery connections
Contact SegenSolar (PTY) Ltd | Email: info@segensolar.co.za | Tel: 011 085 2600
Battery
Inverter
BMS Communication pinouts:
RS485A 5 7
RS485B 3 8
Dipswitch Settings:
Applicable to RS485 communication with all Kodak
inverters
Dipswitch 1set to “ON” position
NB:Newer Pylontech models (US2000C, US3000C,
UP5000) appear upside, set as shown in image
Battery icon flashing indicates : Successful
BMS communication
BMS Communication Setup
NB: BMS cable is included with the Kodak inverters
Contact SegenSolar (PTY) Ltd | Email: info@segensolar.co.za | Tel: 011 085 2600
Contact SegenSolar (PTY) Ltd | Email: [email protected] | Tel: 011 085 2600
Enter programming mode
Set 05 : Select PYL for Pylontech Batteries
If there is parallel inverters, please select USE
on slave inverters
Select suitable frequency in the 9th setting-set
to 50Hz.
If you apply SBU’ mode, except for the first
steps, the 11th setting, the maximum charge
current from grid should be set according to
battery numbers.
The 12th setting, discharge voltage limit is
recommended to not be set below 46V.
The 13th setting, charge voltage limit
recommended to be set at 53V.
LCD
Display
Function
Keys
ON/OFF Switch
BMS communication
Long press to enter
programming menu
Settings
SettingsNewer versions
Contact SegenSolar (PTY) Ltd | Email: [email protected] | Tel: 011 085 2600
ON/OFF Switch
Function Keys
Status Indicators
Function Keys
Setting LED
1,2 & 3
LCD Display
BMS communication Port
Long press to enter
programming menu
Settings
Enter programming mode
Set 05 : Select PYL for Pylontech Batteries
If there is parallel inverters, please select USE
on slave inverters
Select suitable frequency in the 9th setting-set
to 50Hz.
If you apply SBU’ mode, except for the first
steps, the 11th setting, the maximum charge
current from grid should be set according to
battery numbers.
The 12th setting, discharge voltage limit is
recommended to not be set below 46V.
The 13th setting, charge voltage limit
recommended to be set at 53V.
Contact SegenSolar (PTY) Ltd | Email: [email protected] | Tel: 011 085 2600
Error 61 BMS communication failed
POSSIBLE CAUSES:
Incorrect/damaged BMS cable used cable tester
Incorrect DIP switches set on battery Consult
documentation on product page
Incorrect battery type selected Program 05
Incorrect port used on battery/inverter User
manual on product page
NOTE:
OG range only uses RS485 with a Baud rate of
9600
BMS cable included with battery/inverter or
bought from SegenSolar Ask your account
manager or technical support advisor for
assistance
Troubleshooting Most
common communication error
/