MULTISPAN PF-13 Owner's manual

  • I've reviewed the user manual for the MULTISPAN Power Factor Meter PF-13. This document covers the device's technical specifications, safety measures, connection diagram, installation, and maintenance procedures. I'm ready to assist you with any questions you might have about this device.
  • What is the voltage input range for the PF-13?
    What is the current input range for the PF-13?
    What is the operating temperature range?
    What is the panel cutout size?
www.multispanindia.com
Page-1
PF-13
OPERATINGMANUAL
THREEPHASEPOWERFACTOR
PF-13
TechnicalSpecification
Model
Display
Size(mm)
PanelCutout
PowerSupply
Frequency
Protection
Level
(Asperrequest)
PF-13
Operating
Temperature
Relative
Humidity
4Digit/1Line7seg0.56”,redLEDDisplay
96(H)X96(W)X45(D)mm
92X92mm
100To270VAC,50/60Hz,Approx3VA
45To65Hz
IP-65(Frontside)AsperIS/IEC60529:2001
10°CTo50°C
Upto95%RHNonCondensing
Measurement
Range 0.20to1.00PFCATIII
PF
PF 13
0. 0 0
(P-P):50-500VACCATIII
(P-N):30-300VACCATIII
0.1To5AmpACCATIII
VoltageInput
CurrentInput
ConnectionDiagraminputcurrentupto5Amp
www.multispanindia.com
12347 8 9
12
1314
10
11
5
1617181920
6
15
S1 S1 S1 S2S2S2
RY
B
VRVYVBN
System : 3 Ph-4W
Accuracy Class: 0.5
Range
Current: 0.1 To 5A AC
Voltage(P-P) : 50-500V AC
(P-N) : 30-300V AC
LN
!
~
50/60 Hz
3VA
100
270V AC
Made in India
CAT III
www.multispanindia.com
Page-2
PF-13
Allsafetyrelatedcodifications,symbolsandinstructionsthatappearinthisoperatingmanual
orontheequipmentmustbestrictlyfollowedtoensurethesafetyoftheoperatingpersonnelas
wellastheinstrument.
Ifalltheequipmentisnothandledinamannerspecifiedbythemanufacturer,itmightimpairthe
protectionprovidedbytheequipment.
=>Readcompleteinstructionspriortoinstallationandoperationoftheunit.
WARNING:Riskofelectricshock.
3)Cableusedforconnectiontopowersource,musthaveacrosssectionof1mmorgreater.Thesewires
shouldhaveinsulationscapacitymadeofatleast1.5kV.
2)Toreduceelectromagneticinterference,usewirewithadequateratingandtwistsofthesameof
equalsizeshallbemadewithshortestconnection.
1)TopreventtheriskofelectricshockpowersupplytotheequipmentmustbekeptOFFwhiledoingthe
wiringarrangement.Donottouchtheterminalswhilepowerisbeingsupplied.
4)Abetteranti-noiseeffectcanbeexpectedbyusingstandardpowersupplycablefor
theinstrument.
1)Thisequipment,beingbuilt-in-type,normallybecomesapartofmaincontrolpanelandinsuchcase
theterminalsdonotremainaccessibletotheenduserafterinstallationandinternalwiring.
2)Donotallowpiecesofmetal,wireclippings,orfinemetallicfillingsfrominstallationtoenterthe
productorelseitmayleadtoasafetyhazardthatmayinturnendangerlifeorcauseelectricalshockto
theoperator.
3)Circuitbreakerormainsswitchmustbeinstalledbetweenpowersourceandsupplyterminalto
facilitatepowerʻONʼorʻOFFʼfunction.Howeverthismainsswitchorcircuitbreakermustbe
installedatconvenientplacenormallyaccessibletotheoperator.
4)Useandstoretheinstrumentwithinthespecifiedambienttemperatureandhumidityrangesas
mentionedinthismanual.
WarningGuidelines
InstallationGuidelines
MechanicalInstallation
Maintenance
SafetyPrecautions
1)Preparethepanelcutoutwithproperdimensionsasshowabove.
2)Fittheunitintothepanelwiththehelpofclampgiven.
3)Theequipmentinitsinstalledstatemustnotcomeincloseproximitytoanyheatingsource,
causticvapors,oilssteam,orotherunwantedprocessbyproducts.
4)Usethespecifiedsizeofcrimpterminal(M3.5screws)towiretheterminalblock.Tighteningthe
screwsontheterminalblockusingthetighteningtorqueoftherangeof1.2N.m.
5)Donotconnectanythingtounusedterminals.

1) The equipment should be cleaned regularly to avoid blockage of ventilating parts.
2)Cleantheequipmentwithacleansoftcloth.Donotuseisopropylalcoholoranyothercleaningagent.
3)Fusibleresistormustnotbereplacedbyoperator.
2
A
B
C
D
EF
MODEL A
96mm 96mm 92mm 92mm 3mm 50mm
BC
D E
F
DIMENSIONS
136mm - 5.35 inches
120mm - 4.72 inches
PF
PF 13
0. 0 0
Productimprovementandupgradeisaconstantprocedure.SoformoreupdatedoperatinginformationandSupport,
PleasecontactourHelpline:+91-9978991474/76/82orEmailat[email protected]Ver:05-2018
/