F5 and F15 Series ______________
Service and Installation Manual
Please read this manual completely before attempting to install or operate this equipment!
Notify carrier of damage! Inspect all components immediately. See page 2.
F5 and F15 SERIES
Drop In and Serview Display Cases
F5 & F15 Series Service and Installation Manual
F5 & F15 Series Service and Installation Manual
F5 & F15 Series Service and Installation Manual
F5 & F15 Series Service and Installation Manual
F5 & F15 Series Service and Installation Manual
F5 & F15 Series Service and Installation Manual
F5 & F15 Series Service and Installation Manual
F5 & F15 Series Service and Installation Manual
F5 & F15 Series Service and Installation Manual
Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage.
A maximum of 1-hour is allowed to diagnose a defective component.
A maximum of 1-hour is allowed for retrieval of parts not in stock.
A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed.
Overtime, installation/start-up, normal control adjustments, general maintenance, glass breakage, freight damage, and/or
correcting and end-user installation error will not be reimbursed under warranty unless pre-approved with a Service Work
Authorization from Delfield. You must submit the number with the service claim.
LABOR OF 1-HOUR IS ALLOWED TO REPLACE:
Thermostat
Contactor/Relay
Infinite Switch
Transformer
Door Jamb Switch
Evaporator/Condenser Fan Motor and Blade
Solenoid Coil
Circulating Fan Motor and Blade
Hi-limit/Thermal Protector Switch
Microprocessor Control
Fan Delay/Defrost Termination Switch
Water Level Sensor/Probe
Compressor Start Components and Overload Protector
Door Hinges, Locks, and Gaskets
Defrost Timer
Condensate Element
Thermometer
Springs/Lowerator
Gear Box
LABOR OF 2 HOURS TO REPLACE:
Drawer Tracks/Cartridges
Defrost Element
Pressure Control
Heating Element
Solenoid Valve
Locate/Repair Leak
LABOR OF 3 HOURS TO REPLACE:
EPR or CPR Valve
Condenser or Evaporator Coil
Expansion Valve
LABOR OF 4 HOURS TO REPLACE
• Compressor
This includes recovery of refrigerant and leak check.
$35.00 maximum reimbursement for refrigerant recovery (includes recovery machine, pump, torch, oil, flux, minor fittings,
solder, brazing rod, nitrogen, or similar fees.)
REFRIGERANTS
• R22 A maximum of $4.00/lb. or 250/oz. will be reimbursed.
• R134A A maximum of $5.00/lb. or 310/oz. will be reimbursed.
• R404A A maximum of $12.00/lb. or 750/oz. will be reimbursed.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Delfield F15MC72D User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI