Standard 63329 Installation Instructions Manual

Type
Installation Instructions Manual

Standard 63329 LED Flood Fixture: Brighten Your Space Efficiently

With its impressive power and versatility, the Standard 63329 LED Flood Fixture is an ideal choice for illuminating large areas both indoors and outdoors. Engineered to deliver exceptional brightness, this fixture boasts 100W of power, ensuring ample illumination for various applications. Its long-lasting LED technology offers energy-saving benefits while providing a lifespan of up to 50,000 hours, significantly reducing maintenance costs.

Standard 63329 LED Flood Fixture: Brighten Your Space Efficiently

With its impressive power and versatility, the Standard 63329 LED Flood Fixture is an ideal choice for illuminating large areas both indoors and outdoors. Engineered to deliver exceptional brightness, this fixture boasts 100W of power, ensuring ample illumination for various applications. Its long-lasting LED technology offers energy-saving benefits while providing a lifespan of up to 50,000 hours, significantly reducing maintenance costs.

LED FLOOD FIXTURES
INSTALLATION INSTRUCTIONS
IMPORTANT: READ ALL INSTRUCTIONS BEFORE THE INSTALLATION.
NOTE: SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
WARNING: Risk of re or electric shock. The installation should be performed only by a qualied electrician in accor-
dance with the National Electrical Code and relevant local codes. This product must be installed in full accordance with
applicable electrical and building codes.
WARNING - TO AVOID ELECTRIC SHOCK:
• Be certain electrical power is OFF before and during installation and maintenance.
• Luminaire must be connected to a wiring system with an equipment-grounding conductor.
WARNING - TO AVOID EXPLOSION:
• Make sure the supply voltage is the same as the rated luminaire voltage.
• Do not install where marked operating temperatures exceed the ignition temperature of the hazardous atmosphere.
• Do not operate in ambient temperatures above those indicated on the luminaire.
• Keep lens tightly closed when in operation.
• For supply connections use wire rated for at least 100°C.
Order
code
Description Input
voltage
(VAC)
Power
factor
Watts
(W)
Colour
temp.
(K)
63323 LED/FL/10W/30K/KN/120-277V/BRZ/STD 120-277 ≥ 0.90 10 3 000
64217 LED/FL/10W/30K/KN/120-277V/WH/STD 120-277 ≥ 0.90 10 3 000
64218 LED/FL/10W/30K/KN/120-277V/BLK/STD 120-277 ≥ 0.90 10 3 000
63324 LED/FL/10W/40K/KN/120-277V/BRZ/STD 120-277 ≥ 0.90 10 4 000
64219 LED/FL/10W/40K/KN/120-277V/WH/STD 120-277 ≥ 0.90 10 4 000
64220 LED/FL/10W/40K/KN/120-277V/BLK/STD 120-277 ≥ 0.90 10 4 000
63325 LED/FL/30W/30K/KN/120-277/BRZ/STD 120-277 ≥ 0.90 30 3 000
63326 LED/FL/30W/40K/KN/120-277/BRZ/STD 120-277 ≥ 0.90 30 4 000
63327 LED/FL/50W/40K/KN/120-277/BRZ/STD 120-277 ≥ 0.90 50 4 000
63328 LED/FL/80W/40K/SF/120-277/BRZ/STD 120-277 ≥ 0.90 80 4 000
63329 LED/FL/100W/40K/SF/120-277/BRZ/STD 120-277 ≥ 0.90 100 4 000
63330 LED/FL/30W/40K/YK/120-277/BRZ/STD 120-277 ≥ 0.90 30 4 000
63331 LED/FL/50W/40K/YK/120-277/BRZ/STD 120-277 ≥ 0.90 50 4 000
63332 LED/FL/80W/40K/YK/120/277/BRZ/STD 120-277 ≥ 0.90 80 4 000
63333 LED/FL/100W/40K/YK/120/277/BRZ/STD 120-277 ≥ 0.90 100 4 000
Ø21.5 Ø13.5 Ø6.5
10 W
30 W
50 W
100 W
80 W
Ø.10
Ø.10
Ø21.5
Ø21.5
Ø21.5
Ø.10
Ø.10
Ø.10
120
232
265
321
210
152
152
83
83
53
35
60
35
LED FLOOD FIXTURES
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS:
DIRECTLY FIX TO MOUNTING SURFACE
• Use expansion bolts to secure the xture on mounting
surface (FIG. 1).
• Keep enough length wires to ensure adjusting angle
unhindered.
• Connect wires into wiring terminal; white wire to “Neu-
tral”
terminal, black wire to “Live” terminal, green wire to
“Ground”
terminal; and x them by screws.
Adjust the xture to desired orientation, tighten the
screws.
Use cULus Listed Water-proof outlet box cove (FIG. 2).
INSTALLATION INSTRUCTIONS: KNUCKLE MOUNTING ( 80 W / 100 W )
Adjust the xture orientation by turning the bolt (FIG. 1).
• Please use a post of diameter 2.36” for mounting, and tighten with screws (FIG. 2).
• Please drill the holes on the square pole according to the size above (FIG. 3).
Adjust the xture to desired orientation, tighten the screws (FIG. 3).
INSTALLATION INSTRUCTIONS: KNUCKLE MOUNTING (10 W / 30 W / 50 W )
Adjust the two screws turn the xture left and right, up and down (FIG. 1).
• Secure service wire or conduit to the wiring compartment cover with 1/2” connector ( not provided ). ). Connect
white xture wire to white supply wire, black xture wire to black supply wire. Service ground should be attached to
green ground screw provided. Ground must be properly attached to avoid the risk of electrical shock. Use wire nuts,
crimp-on lugs, or other approved devices to connect all wires. Make sure connections are secure and that no loose wire
strands are sticking out of connectors. Secure wiring compartment cover to xture, with black and white connections
inside the wiring compartment. Use UL and CUL Listed exible steel waterproof conduit in trade size 1/2 and cULus
water-proof outlet box cove.(FIG. 2).
1 2
1 2 3
G(GREEN)
L(BLACK)
N(WHITE)
WALL
1 2
  • Page 1 1
  • Page 2 2

Standard 63329 Installation Instructions Manual

Type
Installation Instructions Manual

Standard 63329 LED Flood Fixture: Brighten Your Space Efficiently

With its impressive power and versatility, the Standard 63329 LED Flood Fixture is an ideal choice for illuminating large areas both indoors and outdoors. Engineered to deliver exceptional brightness, this fixture boasts 100W of power, ensuring ample illumination for various applications. Its long-lasting LED technology offers energy-saving benefits while providing a lifespan of up to 50,000 hours, significantly reducing maintenance costs.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI