VAT 14046-PE06 Owner's manual

Type
Owner's manual

VAT 14046-PE06 is a gate valve with manual actuator and can be used in a pressure range of 1 x 10-8 mbar to 2 bar (abs) in diameters of DN 63 - 200. It is especially designed for clean and dry indoor vacuum applications.

Due to its compact and simple design, the VAT 14046-PE06 is suitable for various vacuum systems. It can be installed in any position and is insensitive to vibrations. The valve is characterized by its high reliability and long service life.

The VAT 14046-PE06 is easy to install and maintain. The manual actuator allows for precise and easy operation. The valve can be disassembled and reassembled quickly and easily, which makes maintenance and repairs straightforward.

VAT 14046-PE06 is a gate valve with manual actuator and can be used in a pressure range of 1 x 10-8 mbar to 2 bar (abs) in diameters of DN 63 - 200. It is especially designed for clean and dry indoor vacuum applications.

Due to its compact and simple design, the VAT 14046-PE06 is suitable for various vacuum systems. It can be installed in any position and is insensitive to vibrations. The valve is characterized by its high reliability and long service life.

The VAT 14046-PE06 is easy to install and maintain. The manual actuator allows for precise and easy operation. The valve can be disassembled and reassembled quickly and easily, which makes maintenance and repairs straightforward.

Installation, Operating, and Maintenance Instructions
Series 14, DN 63 - 400 (I.D. 2 ½ - 16")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
207935EF
2009-10-14
1/21
Product HV Gate Valve
with manual actuator
This manual is valid for the valve ordering number(s):
14036-
.
E01/06/07/08
14038-
.
E01/06/07/08
14040-
.
E01/06/07/08
14044-
.
E01/06/07/08
14046-
.
E01/06/07/08
14048-
.
E01/06/07/08
14050-
.
E01/06/07/08
14052-
.
E01/06/07/08
The fabrication number is indicated on each product as per the label
below (or similar):
made in Switzerland
Fabrication No.:
patented
. .
140
. . .
. . . . / . . . .
A
. . . . . .
Fabrication number
Explanation of symbols:
Read declaration carefully before you start any other
action!
Keep body parts and objects away from the valve
opening!
Attention!
Hot surfaces; do not touch!
Product is in conformity with EC guidelines,
if applicable!
Loaded springs and/or air cushions are potential
hazards!
Disconnect electrical power and compressed air lines.
Do not touch parts under voltage!
Wear gloves!
Read these «Installation, Operating & Maintenance Instructions» and the enclosed «General
Safety Instructions» carefully before you start any other action!
Installation, Operating, and Maintenance Instructions
Series 14, DN 63 - 400 (I.D. 2 ½ - 16")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
207935EF
2009-10-14
2/21
Imprint:
Manufacturer VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Website
www.vatvalve.com
Phone
+41 81 771 61 61
Fax
+41 81 771 48 30
Email
CH@va
tvalve.com
Publisher
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Editor
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Print
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Copyright
© VAT Vakuumventile AG 2008
No part of these Instructions may be reproduced in any way (photocopies, microfilms or any
other reproduction processes) nor may it be manipulated with electronic systems, duplicated or
distributed without written permission from VAT.
Offenders are liable to pay damages.
The original VAT firmware and updated state of the art versions of the VAT firmware are
intended for use with VAT products. The VAT firmware contains a limited, time unlimited user
license. The VAT firmware may not be used for purposes other than those intended nor is it
permitted to make copies of the VAT firmware. In particular, it is strictly forbidden to give
copies of the VAT firmware to other people.
The use of trade names, brand names, trademarks, etc. in these Instructions does not entitle
third parties to consider these names to be unprotected and to use them freely. This is in
accordance with the meaning of the laws and acts covering brand names and trademarks.
Installation, Operating, and Maintenance Instructions
Series 14, DN 63 - 400 (I.D. 2 ½ - 16")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
207935EF
2009-10-14
3/21
Contents:
1
Use of product .......................................................................................................................................................... 4
1.1
Technical data .................................................................................................................................................... 4
2
Installation ................................................................................................................................................................. 5
2.1
Unpacking .......................................................................................................................................................... 5
2.2
Installation into the system ................................................................................................................................. 5
2.3
Admissible forces and bending moment ............................................................................................................ 6
2.4
Connections ....................................................................................................................................................... 7
2.4.1
Electrical connection ................................................................................................................................ 7
3
Operation .................................................................................................................................................................. 7
3.1
Normal operation ................................................................................................................................................ 7
3.2
Operation under increased temperature ............................................................................................................ 7
3.3
Differential pressure ........................................................................................................................................... 7
4
Trouble shooting ....................................................................................................................................................... 8
5
Maintenance & repairs .............................................................................................................................................. 9
5.1
General maintenance instruction ....................................................................................................................... 9
5.2
Preventive maintenance ................................................................................................................................... 10
5.3
Safety instruction .............................................................................................................................................. 11
5.4
Maintenance of assemblies .............................................................................................................................. 12
5.4.1
Preparing valve maintenance ................................................................................................................ 12
5.4.2
replacing of gate seal / mechanism / bonnet seal .................................................................................. 12
5.4.3
Replacing of ball bearings 11 on mechanism ........................................................................................ 13
5.4.4
Disassembling of mechanism / replacing of locking balls ..................................................................... 13
5.4.5
Dismantling and mantling of actuator ..................................................................................................... 14
5.4.6
Dismantle of rotary feed through and replacing the feed through seals ................................................ 15
6
Drawing ................................................................................................................................................................... 16
6.1
Valve Assembly ................................................................................................................................................ 16
6.2
Mechanism assembly ....................................................................................................................................... 17
7
Spare parts ............................................................................................................................................................. 20
8
Warranty ................................................................................................................................................................. 21
Installation, Operating, and Maintenance Instructions
Series 14, DN 63 - 400 (I.D. 2 ½ - 16")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
207935EF
2009-10-14
4/21
1 Use of product
Use product for clean and dry indoor vacuum applications under the conditions indicated in chapter «Technical data» only!
Other applications are only allowed with the written permission of VAT.
1.1 Technical data
Pressure range DN 63 - 200 1 x 10
-8
mbar to 2 bar (abs)
DN 250 - 400 1 x 10
-8
mbar to 1.2 bar (abs)
Differential pressure on the gate DN 63 - 200 2 bar in either direction
DN 250 - 400 1.2 bar
Max. differential pressure at opening 30 mbar
Admissible temperature: Valve 150°C
Manual actuator 80°C
Further data according to newest VAT catalogue «Vacuum Valves».
Installation, Operating, and Maintenance Instructions
Series 14, DN 63 - 400 (I.D. 2 ½ - 16")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
207935EF
2009-10-14
5/21
2 Installation
2.1 Unpacking
Make sure, that the delivered components are according to the order.
Visually check the quality of the components.
If some element of the delivery is not as expected please contact VAT immediately.
Notice:
Please do not throw away the original packaging. Packaging may be useful in future should the components be returned
to VAT.
Check immediately after receiving and unpacking the valve ,
- that the delivered components are corresponding with the order!
- regarding quality!
- regarding quantity!
Please do not throw away the original packaging. Packaging may be useful in future should the
components be returned to VAT.
Open package box cautiously to avoid any damages on product. Lift the valve out off package with appropriate equipment.
Fix the lifting straps on the installed eye bolts ( the dimensional drawing indicates the eye bolts with ). Lift the crane
hook slowly until the straps are under tension. Keep lifting the hook and move the hook step by step until the valve is in
vertical position. Lift the valve out off the box and move it slowly to the mounting chamber flange.
ATTENTION: HEAVY LOAD!
use especially for larger valves a lifting aid ( crane or any similar)
ATTENTION: Do not lift the valve at actuator.
Attach the lifting ropes to the lifting elements ( the dimension drawing
indicates to the eye bolts with ).
2.2 Installation into the system
The valve seat side is indicated by the symbol "" on the connection flange.
Preparation for mounting the valve to the system
1. Clean the sealing surface and the O-ring seal of the mating flange.
2. Move the gate valve into the correct mounting position with the crane.
ATTENTION: Do not hit the sealing surfaces while maneuvering into position!
3. Offer valve to first the flange and initially and hold in position using two bolts opposite each other.
4. Further securing using two additional bolts inserted around from the first two bolts.
5. Fasten the 4 bolts crosswise until the O-ring seal makes contact with the valve sealing surface.
6. Apply all remaining screws
7. Fasten all screws gradually in crosswise order.
Installation, Operating, and Maintenance Instructions
Series 14, DN 63 - 400 (I.D. 2 ½ - 16")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
207935EF
2009-10-14
6/21
2.3 Admissible forces and bending moment
Evacuating the system, the weight of assemblies or heating causes forces which can affect the appropriate functionality
Of the valve. Such forces have to be eliminated by means of compensating them or proper reinforcements. The following
forces are admissible:
DN (nom. I.D.) Axial traction or pressure
force «F Bending moment «M»
F
A
M
sketch 1
mm inch N lbf Nm lbf . ft
63 2½ 1960 440 78 58
80 3 1960 440 78 58
100 4 2450 560 98 72
160 6 2940 660 147 108
200 8 2940 660 147 108
250 10 3430 770 196 145
320 12 3920 880 294 217
350 14 3920 880 294 217
400 16 7840 1760 980 722
In case of both kind of forces are occurring («FA» und «M»), the above shown
values are invalid. Please contact VAT in this case.
Table 1
Installation, Operating, and Maintenance Instructions
Series 14, DN 63 - 400 (I.D. 2 ½ - 16")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
207935EF
2009-10-14
7/21
2.4 Connections
2.4.1 Electrical connection
Do not touch electrical parts under voltage!
Connect electrical power only if
- valve has been installed into the vacuum system
- moving parts cannot be touched
The socket for the position indicator is supplied with the valve.
Wire the position indicator according to the diagram opposite:
Standard-position indicatorr Double position indicator (Option)
Valve closed
1 2
3
4
5 6
1
2
6
5
4
3
Lo
Lg
Valve closed
C (3)
A (1)
B (2)
J (9)
G (7)
H (8)
D (4)
F (6)
E (5)
K (10)
M (12)
A B
C
D
E
G
H J K
L
M
F
L (11)
Lo
Lo
Lg
Lg
Lo = position indicator «open»
Lg = position indicator «closed» Lo = position indicator «ope
Lg = position indicator «closed»
Figure 1
3 Operation
3.1 Normal operation
Valve is opened and closed by means of a manual spindle.
3.2 Operation under increased temperature
See «1.1 Technical data»
3.3 Differential pressure
See 1.1 «Technical data»!
Installation, Operating, and Maintenance Instructions
Series 14, DN 63 - 400 (I.D. 2 ½ - 16")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
207935EF
2009-10-14
8/21
4 Trouble shooting
Failure check remedy
Leak on gate : Is the valve locked properly?
Is seat sealing surface and/or gate
soiled or damaged?
Check position indicator for closed
Position.
Clean or replace gate seal in case of
any damage!
If the sealing surface is damaged
contact the nearest VAT service
centre .
Leak on body:
Are the body flanges on interface
surfaces leak tight?
Fastening torque OK?
Are the admissible forces OK?
Any dirt or soil ?
Damages onto sealing surface ?
Fasten bolts according chapter 2.3!
Check according chapter . 2.4 !
Clean sealing surfaces and seals!
Contact the nearest VAT service
centre
!
Is there a leak at rotary feed through?
Use provided hole on feed through for
leak detecting!
Contact the nearest VAT service
centre!
Leak at bonnet seal? Clean bonnet seal or replace it in
case of any damages. If the sealing
surface is damaged contact the
nearest VAT service centre!
Table 2
If you need any further information, please contact one of our service centers. You can find the addresses on our website:
http://www.vat.ch
Installation, Operating, and Maintenance Instructions
Series 14, DN 63 - 400 (I.D. 2 ½ - 16")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
207935EF
2009-10-14
9/21
5 Maintenance & repairs
Under clean operating conditions, the valve does not require any maintenance during the specified cycle life.
Contamination from the process may influence the function and requires more frequent maintenance.
Before carrying out any maintenance or repairs, please contact VAT. It has to be individually decided whether the
maintenance/repair can be performed by the customer or has to be carried out by VAT. The fabrication number on the
valve
made in Switzerland
Fabrication No.: patented
. .
. . . . . . . . . . . . . / . . . .
A
. . . . . .
Fabrication number
has always to be specified.
All supplies (e. g. compressed air, electrical power) must be disconnected for removal/installation of the valve from/into
the system and for maintenance work.
Even with disconnected supply, loaded springs and/or air cushions in cylinders can be potential hazards.
Keep fingers and objects away from the valve opening!
Products returned to VAT must be free of harmful substances such as e.g. toxical, caustic or microbiological ones. If
products are radioactively contaminated, fill in the VAT form «Contamination and Radiation Report» and send it with the
product. The form is available at VAT. The maximum values indicated in the form must not be exceeded.
5.1 General maintenance instruction
Under clean operating conditions, the valve does not require any maintenance during the specified cycle life.
Note! Process has influence to the suggested maintenance interval and can shorten it. ( e.g. due to corrosive gases
or accumulation to the inner parts of valve )
To minimise downtime and expenditure of equipment you can replace the whole mechanism by a spare mechanism
Attention! Never loosen or readjust adjusting plate (X)! ( see chapter 6)
Installation, Operating, and Maintenance Instructions
Series 14, DN 63 - 400 (I.D. 2 ½ - 16")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
207935EF
2009-10-14
10/21
5.2 Preventive maintenance
For clean vacuum application VAT suggests preventive maintenances after 200'000 cycles
1
The numbers in brackets are referring to drawing in chapter 6
- clean gate o-ring and sealing surfaces
- investigate bonnet seal (3), ball bearings (11) on mechanism and crank bolt (6) for signs of wear. Clean or re-lubricate
or replace them if necessary ( see chapter 7 spare parts )
- replace all parts showing corrosions, accumulations or signs of wear ( see chapter 7 spare parts )
General
signs of wear Replace part
dust or dirt Clean part and re-
lubricate it
When cleaning parts always dismount them according to chapter 5.4 and clean the single
parts only.
Never put whole assemblies into the cleaning bath
Always lubricate parts accordingly or use lubricated spares !
1
The mentioned cycles are invalid for DN400 in vertical mounting position
Installation, Operating, and Maintenance Instructions
Series 14, DN 63 - 400 (I.D. 2 ½ - 16")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
207935EF
2009-10-14
11/21
5.3 Safety instruction
CAUTION : risk of injury
RISK of dropping mechanism
RULES for accident prevention:
If the valve is installed in a vertical position ( bonnet up) it is possible that when dismounting
the crank bolt (6) step 5 ( see below) that the mechanism can drop due to the force of
gravity. Therefore absolutely consider the size of valve and consequently the weight of
mechanism
CAUTION : risk of injury
RISK of catapulting parts
RULES for accident prevention:
The actuation may only dismantled by authorized and trained staff!
If you dismount the actuation and cylinder cover respectively for replacing the pneumatic
seals pay attention that the circlip does not jump out of the groove.
When reassembling the circlip make sure that it is mounted and fixed in to the groove
properly
Inappropriate mounting of circlip can catapult out the cover when actuating the valve.
This is potentially a CONSIDERABLE RISK of injury.
CAUTION : risk of injury
RISK of electro shock
RULES for accident prevention:
DISCONNECT valve while maintaining it
1. vent the vacuum chambers on both sides up to atmospheric pressure.
2. open the valve.
3. switch off compressed air supply.
4. switch off power supply.
5. disconnect compressed air and power supply from valve.
Always carry out the Steps 1 to 5 before maintaining a valve.
Installation, Operating, and Maintenance Instructions
Series 14, DN 63 - 400 (I.D. 2 ½ - 16")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
207935EF
2009-10-14
12/21
5.4 Maintenance of assemblies
5.4.1 Preparing valve maintenance
Provide a clean working space for assembling and storage for dismounted parts.
5.4.2 replacing of gate seal / mechanism / bonnet seal
The numbers in brackets are referring to drawing in chapter 6
Tip:
Provide a clean working space for assembling and storage for dismounted parts. .
1. Before dismounting the valve please read the safety instructions in chapter 5.3
2. Undo bolted joint (1) from bonnet flange (2)
3. Put bonnet seal and bonnet onto a clean working space.
4. Move mechanism by means of manual operation to «open» position
5. Remove screw (5)
6. Remove crank bolt (6) ( if required lift mechanism slightly .)
7. Draw mechanism out of valve body carefully and put it onto a clean working
Attention: Do not damage mechanism! (disassembling of mechanism see chapter 5.4.4)
8. Take out gate O-Ring (4) from o-ring groove
Attention: Do not damage the sealing surface on groove bottom!
9. Dismantle mechanism in single parts or assemblies (disassembling of mechanism see chapter 5.4.4)
Attention: do not loosen adjusting plate (X)!
10. Clean mechanism in an appropriate way
Attention: after cleaning, grease have to be removed or ineffective !
11. Assemble mechanism again
Attention: use new locking balls (10), ball bearings / leaf springs (11) or/and crank bolt (6)!
(these parts always lubricated with VAT High vacuum grease )
12. Clean and check grooves and sealing surfaces properly
13. Install a new gate o-ring (4)
Attention: press o-ring evenly and simultaneously on opposite side ( diagonal) in to the groove!
14. Mount the mechanism to the valve body cautiously.
15. Install crank bolt (6)
16. Mount bolt (5) and tighten it
17. Move mechanism by hand in closing direction
18. Place bonnet seal (3) and bonnet (2)
19. Tighten bolt (1) on bonnet flange (2) uniformly and on opposite side ( diagonal ) ,
20. Torque :
DN 63 - 100 10 Nm / 8 lbf . ft
DN 160 - 400 18 Nm / 13 lbf . ft
21. Connect power
22. Connect compressed air
23. Carry out function and leak test
24. Valve is ready to operate
Installation, Operating, and Maintenance Instructions
Series 14, DN 63 - 400 (I.D. 2 ½ - 16")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
207935EF
2009-10-14
13/21
5.4.3 Replacing of ball bearings 11 on mechanism
The numbers in brackets are referring to drawing in chapter 6
Tip:
Provide a clean working space for assembling and storage for dismounted parts.
- DN 160 - 200: replace complete leave spring (11) including two ball bearings
Attention: after unscrewing the threaded studs on gate have to be lubricated with VAT High vacuum
grease slightly! This avoids seizing of nuts to the bolts.
DN 250 - 400: replace the ball bearings singly
Attention: lubricate slightly the trunnion or the nut with VAT High vacuum grease after unscrewing it!
This avoids seizing of nut to the trunnion.
5.4.4 Disassembling of mechanism / replacing of locking balls
The numbers in brackets are referring to drawing in chapter 6.2
Tip:
Prepare a clean working space for assembling and storage for dismounted parts.
DN 63 and 100 ( see chapter 6.2)
1. Before dismounting the valve please read the safety instructions in chapter 5.3
2. Put mechanism carefully onto a clean working space with the seat side downwards
3. push leaf spring and centre ring down slightly and take out the divided circlip off the leading centre bolt groove
4. lift off leaf spring and centre ring.
5. keep gate and ball guidance together properly and turn over the mechanism. Put it with the ball guidance
downward onto the working space.
6. Take off the gate and put it with the sealing side downwards onto the working space.
7. Now take out the locking balls and clean or replace them if necessary.
Attention:
when replacing the locking balls
the locking balls of spare parts kit ( see chapter 7 table item 10 ) are lubricated from VAT side with VAT High
vacuum grease already
When cleaning the locking balls
If cleaning the locking balls lubricate them with VAT High vacuum grease afterwards!
8. clean the ball guidance
9. clean the ball tracks
10. put the locking balls into the ball guidance again.
11. set the gate onto the ball guidance again
Attention: pay attention that the joint of guidance it positioned in the right way ( see drawing chapter
6.1and 6.2)
12. Mount the leaf spring in reverse way as described above (see 3 )
Attention: lubricate the nuts and studs with VAT High vacuum grease slightly (seizing)!
DN 160 to 400 (see chapter 6.2)
1. Before dismounting the valve please read the safety instructions in chapter 5.3
2. Put mechanism carefully onto a clean working space with the seat side downwards
3. remove the 4 and 6 nuts respectively holding the leaf springs
Installation, Operating, and Maintenance Instructions
Series 14, DN 63 - 400 (I.D. 2 ½ - 16")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
207935EF
2009-10-14
14/21
4. take out the leaf springs
5. take off counter plate
6. take out above laying locking balls and put in onto working space
7. lift off ball guidance
8. take out the beneath locking balls from recess` and put it on the working space
9. Now you can clean or replace the locking balls
Attention:
when replacing the locking balls
the locking balls of spare parts kit ( see chapter 7 table item 10 ) are lubricated from VAT side with VAT High
vacuum grease already
When cleaning the locking balls
If cleaning the locking balls lubricate them with VAT High vacuum grease afterwards!
10. clean the ball guidance
11. clean the ball tracks of gate an counter gate.
12. put the locking balls into the recess of gate again.
13. insert the lubricated locking balls into the ball tracks of gate again.
14. set the ball guidance onto the gate and install the locking balls
Attention: pay attention that the joint of guidance is positioned in the right way ( see drawing chapter 6.1)
15. set the counter gate onto the ball guidance
Attention: pay attention that the counter gate is positioned in the right way
16. mount on the leaf spring in opposite way like described above (see 4 to 1)
Attention: lubricate the nuts and studs with VAT High vacuum grease slightly (seizing)!
5.4.5 Dismantling and mantling of actuator
The numbers in brackets are referring to drawing in chapter 6
1. Move valve to closed position
2. Remove position indicator housing ( 4 screws)
3. Open and remove two hexagon screws fixing the actuation
4. Withdraw actuation from gear wheel of rotary feed through.
5. For remounting the actuation again bring it in closed position
Attention: Valve with actuation in position A the piston rod has to be in extended position!
Valve with actuation in position B the piston rod has to be in retracted position!
6. For mounting the actuation the valve has to be in closed and locked position. For closing and locking the valve
use a proper flat wrench and turn at the four cornered shaft (X) of rotary feed through.
7. Set the actuator onto the pinion of rotary feed through with out tilting. If it is not possible to stick through the bolts
turn the actuation slightly counter clockwise
8. Fasten the bolts
9. Mount position indicator again.
Installation, Operating, and Maintenance Instructions
Series 14, DN 63 - 400 (I.D. 2 ½ - 16")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
207935EF
2009-10-14
15/21
5.4.6 Dismantle of rotary feed through and replacing the feed through seals
Dismantle of rotary feed through and replacing the feed through seals (14)
The numbers in brackets are referring to drawing in chapter 6
Preparation :
1. dismount the mechanism like described above.
2. dismount the actuator like described above.
Dismounting of rotary feed through:
1. take out safety splint pin (12) and remove the lever.
2. unscrew the two screws of rotary feed through.
3. take out the rotary feed through and replace O–ring (14)
Attention: lubricate the o-ring with VAT High vacuum grease slightly!
4. mount the rotary feed through in reverse order
Installation, Operating, and Maintenance Instructions
Series 14, DN 63 - 400 (I.D. 2 ½ - 16")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
207935EF
2009-10-14
16/21
6 Drawing
6.1 Valve Assembly
11
1
6
12
5
5
4
3
2
1
10
sketch 2
Installation, Operating, and Maintenance Instructions
Series 14, DN 63 - 400 (I.D. 2 ½ - 16")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
207935EF
2009-10-14
17/21
6.2 Mechanism assembly
DN63/100
sketch 3
single parts
1. Gate O-ring
2. Gate
3. Leaf spring
4. Ball guidance
5. Locking balls
6. Counter dink screw
7. Leaf spring
8. Holding ring
9. Divided ring
DN160/200
sketch 4
single parts
1. Gate O-ring
2. Gate
3. Leaf spring
4. Ball guidance
5. Locking balls
6. Leaf spring
7. Counter plate
8. Adjusting plate ( do not loosen)
6
7
8
Installation, Operating, and Maintenance Instructions
Series 14, DN 63 - 400 (I.D. 2 ½ - 16")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
207935EF
2009-10-14
18/21
DN250
sketch 5
Single parts
1. Gate O-ring
2. Plate
3. Locking balls
4. Ball guidance
5. Leaf spring
6. Adjusting plate ( do not loosen)
7. Leaf spring with ball bearing
8. Counter plate
DN320
sketch 6
Single parts
1 Gate O-ring
2 Plate
3 Locking balls
4 Ball guidance
5 Leaf spring with adjusting nose
6 Leaf spring
7 Adjusting ring
8 Safety nut
8.1 Washer
9 Leaf spring with ball bearing
9.1 Ball bearing
Installation, Operating, and Maintenance Instructions
Series 14, DN 63 - 400 (I.D. 2 ½ - 16")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
207935EF
2009-10-14
19/21
DN400
sketch 7
Single parts
1 Gate O-ring
2 Plate
3 Leaf spring
4 Ball bearing
5 Ball guidance
6 Locking balls
7 Adjusting ring
8 Adjusting plate ( do not loosen)
9 Grub screw
10 Leaf spring
11 Counter plate
Installation, Operating, and Maintenance Instructions
Series 14, DN 63 - 400 (I.D. 2 ½ - 16")
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
207935EF
2009-10-14
20/21
7 Spare parts
Please specify the fabrication number of the valve (see yellow label on valve) when ordering spare parts. This is
to ensure that the appropriate spare parts are supplied.
The numbers in brackets are referring to drawing in chapter 6.1
Item description Order-number
DN
63 80 100 160 200 250 320 350 400
Mechanism
complete
89146-R1 219967 94842-R1 84275-R1 84608-R1 83481-R1 209812 209812 215561
Seal kit
1
)
97442-R1 225315 97446-R1 95944-R1 95939-R1 98472-R1 98474-R1 98474-R1 98476-R1
2
Bonnet cover
77776-01 77776-01 77779-01 77782-01 77785-01 87334-01 87335-01 87335-01 87336-01
3
Bonnet seal
77775-R1 77775-R1 77778-R1 77781-R1 77784-R1 N-5100-378 N-5100-382 N-5100-382 N-5100-383
4
Gate seal
N-5102-340 220113 N-5102-351 N-5102-364 N-5102-372 N-5102-453 N-5102-457 N-5102-457 N-5100-461
6
Crank bolt
complete
2
)
205048 205048 205048 205048 205048 205049 205049 205049 205051
7
Position indicator
60546-R1 60546-R1 60546-R1 60546-R1 60546-R1 60546-R1 60546-R1 60546-R1 60546-R1
8
Solenoid
3
)
N-7501-501 N-7501-501 N-7501-501 N-7501-501 N-7501-501 N-7501-501 N-7501-501 N-7501-501 N-7501-501
10
1 spare kit locking
balls (lubricated)
98440-R1 98440-R1 98441-R1 98442-R1 95121-R1 98443-R1 98444-R1 98444-R1 98445-R1
11
1 leaf spring
complete
[...] quantity per
valve l
66856-R1
[1 pc] 66856-R1
[1 pc] 67064-R1
[2 pc] 84326-R1
[2 pc] 80642-R1
[2 pc] 99205-R1
[4 pc] 4) 99205-R1
[4 pc] 4) 99205-R1
[4 pc] 4) 77286-01
[4 pc] 4)
12
Dowel pin
N-6097-478 N-6097-509 N-6097-478 N-6097-480 N-6097-480 N-6097-509 N-6097-509 N-6097-509 N-6097-509
Table 3
1
)
Seal kit consist of Item. 3, 4, 13 & 14 according to chapter 6.1(standard material is Viton)
2
)
Item. 5 is enclosed to
crank bolt complete
3
) Inform about voltage!!
4
)
DN250 to DN400 only ball bearing without leaf spring
VAT Vakuumventile AG shows its willingness to take over servicing your valve. For that please contact the next VAT
representative responsible for your country. Delivery and maintenance will be done in one of our service centres in Haag
(Switzerland), in Woburn (USA) or in Ako (Japan).
Always use lubricated spares !
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21

VAT 14046-PE06 Owner's manual

Type
Owner's manual

VAT 14046-PE06 is a gate valve with manual actuator and can be used in a pressure range of 1 x 10-8 mbar to 2 bar (abs) in diameters of DN 63 - 200. It is especially designed for clean and dry indoor vacuum applications.

Due to its compact and simple design, the VAT 14046-PE06 is suitable for various vacuum systems. It can be installed in any position and is insensitive to vibrations. The valve is characterized by its high reliability and long service life.

The VAT 14046-PE06 is easy to install and maintain. The manual actuator allows for precise and easy operation. The valve can be disassembled and reassembled quickly and easily, which makes maintenance and repairs straightforward.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI