Heat & Glo FB-Reset Kit 2201-970 Install Manual

Type
Install Manual
1
Hearth & Home Technologies • FireBrick Reset Switch Kit Instructions • 2201-970 Rev. C • 1/11
FB-RESET Kit
Models: Escape-I30FB, Escape-I35FB, QFI30FB, QFI35FB
- Installation Instructions -
CAUTION! Risk of Cuts or Abrasions. Wear protective
gloves and safety glasses during installation.
KIT COMPONENTS
(1) Module Jumper Wire
(1) Module Reset Wire Assembly
(1) Rocker Switch
(1) Battery tray/switch
(1) Velcro Piece
Leave this manual with party responsible for use
and operation.
Figure 1. Remove Back Access Panel
Installation
1. Remove back access panel by removing the 5 screws
as shown in Figure 1.
2. Unplug the 6V adapter from the module. See Figure 2.
Figure 2. Unplug 6V Adapter from Module
SCREWS
SCREWS
6V ADAPTER
6V ADAPTER
Figure 3. Plug in Jumper Wire Assembly
3. Plug the new jumper assembly into the 6V adapter and
the module as shown in Figure 3.
4. The battery tray is located in the lower left front of the
appliance as shown in Figure 4. A notch on the right
side of the tray engages the tray with the appliance.
See Figure 5 for location of notch. To remove the tray,
rotate the left side of the tray outward and pull to the left
to disengage the notch.
5. Remove the battery pack from the tray and discard the
metal battery tray.
Figure 4. Battery Tray Location
Figure 5. Reset Switch and Notch Location
RESET
RESET
SWITCH
SWITCH
NOTCH
NOTCH
BATTERY TRAY
BATTERY TRAY
Hearth & Home Technologies • FireBrick Reset Switch Kit Instructions • 2201-970 Rev. C • 1/11
2
Please contact your Hearth & Home Technologies
dealer with any questions or concerns.
For the location of your nearest Hearth & Home Technologies dealer,
please visit www. reside.com
Hearth & Home Technologies Inc.
7571 215th Street West, Lakeville, MN 55044
www. reside.com
6. Place the battery pack on the new supplied battery
tray with the Velcro supplied in the kit.
7. Feed the module reset wire assembly through the
front of the appliance to the back by the module.
8. Reinstall the new battery tray.
9. Connect the 24 inch wire assembly to the new mod-
ule wire assembly. See Figure 7.
10. Refer to shaded area on Figure 8 for completed wir-
ing diagram.
11. Reattach the back panel by installing the ve screws.
Operation Instructions
This module may lock-out under certain conditions. When
this occurs, the appliance will not ignite or respond to
commands. The module will go into lock-out mode by
emitting three audible beeps, then continuously display a
RED/GREEN error code at its status indicator LED.
Check battery tray. Remove batteries if installed.
Batteries should only be installed for power outages.
See appliance installation manual for more information.
• Locate the module reset switch. (See Figure 6).
• Set the module reset switch to the RESET position.
• Wait ve (5) minutes to allow possible accumulated gas
to clear.
• Set the module reset switch to ON.
• Start the appliance.
WARNING! Risk of Explosion! DO NOT press the mod-
ule reset switch more than one time. Gas may accumu-
late in rebox. Call a quali ed service technician.
Figure 6.
Figure 7.
AUX WIRE EXTENSION
(2201-155)
LIGHT WIRE ASSEMBLY
(2201-013)
OPTIONAL
TO CORD ASSEMBLY
120VAC
AUX 300
MODULE
AUX1 AUX2
FAN
BATTERY PACK
6V DC (AA X 4)
ACCENT SOCKETS (2)
(2146-402)
EMBER BULB 20W (2)
(2088-136)
GROUND
ORANGE
(PILOT) GREEN
(MAIN)
TO CORD ASSEMBLY
120VAC MODULE ORG
WHT
INTERMITTENT PILOT IGNITOR
BLACK
RED
AUX2 NOT USED FOR INSERT MODELS.
PROTECTIVE COVER INCLUDED.
RC300 4.5V DC
(AA X 3)
MODULE
JUMPER WIRE
2179-300
MODULE RESET
SWITCH
2206-299
WIRE ASSEMBLY
2201-030
RESET SWITCH/OPERATION MODE
RESET SWITCH/OPERATION MODE
Figure 8. IPI Wiring Diagram
  • Page 1 1