Perlick CR24D-1-4L User guide

Type
User guide

This manual is also suitable for

PERLICK CR24 COLUMN REFRIGERATION
PLANNING GUIDE
ALL THE DELICIOUS DETAILS OF THE NEW PERLICK CR24 COLUMN REFRIGERATION
Enjoy the flexibility of Perlick column refrigeration by mixing and matching units to create
custom storage for food, wine and beverages. Columns can be installed individually or installed
side-by-side in a pair or more to serve any sized kitchen.
The following provides installation guidance for planning your space. For complete installation
instructions, please refer to the column installation guide on perlick.com/residential.
3 CR24 MODEL LIST
3 CR24 ACCESSORY LIST
4 DOOR OVERLAY TEMPLATES
4 OVERLAY, SOLID DOOR
5 OVERLAY, GLASS DOOR
6 INSTALLATION
7 OPENING DIMENSIONS, SINGLE INSTALL
7 OPENING DIMENSIONS, DUAL INSTALL
8 OPENING DIMENSIONS, TRIPLE INSTALL
CR24R COLUMN REFRIGERATOR
CR24F COLUMN FREEZER
CR24W COLUMN SINGLE-ZONE WINE RESERVE
CR24D COLUMN DUAL-ZONE WINE RESERVE
CR-ACC-24SEPR/L
Stainless Steel Exterior Finishing Panels (for le or right side of
exposed column)
CR-ACC-D1
Dual Installaon Kit, Handle-To-Handle Or Hinge-To-Hinge,
With Heater, Column
CR-ACC-D1N
Dual Installaon Kit, Handle-To-Handle Or Hinge-To-Hinge,
No Heater, Column
CR-ACC-D2N
Dual Installaon Kit, Hinge To Handle, 2 Inch Trim,
No Heater, Column
CR-ACC-TRIM
Built-in Trim Kit (le and right nish trim kit for built-in
columns)
CR-SS-24PDL/R
Stainless Steel Solid Door Panel w/Two Tone Perlick Pro Handle
(le or right hinge - available for 4" or 6" toe kicks)
CR-SG-24PDL/R
Stainless Steel Glass Door Panel w/Two Tone Perlick Pro Handle
(le or right hinge - available for 4" or 6" toe kicks)
CR-PRO-HANDLE
Two Tone Perlick Pro Handle (when sold separately for use with
customer-supplied door panel)
CR24 COLUMN REFRIGERATION ACCESSORIES A B
A FACTORY INSTALLED B FIELD INSTALLED
CR24R-1-2L All Refrigerator, Solid Overlay Door, Hinged Le
CR24R-1-2R All Refrigerator, Solid Overlay Door, Hinged Right
CR24R COLUMN REFRIGERATOR
CR24F-1-2L All Freezer, Solid Overlay Door, Hinged Le
CR24F-1-2R All Freezer, Solid Overlay Door, Hinged Right
CR24F COLUMN FREEZER
CR24W-1-4L
Wine Reserve, Single Zone, Glass Overlay Door,
Hinged Le
CR24W-1-4R
Wine Reserve, Single Zone, Glass Overlay Door,
Hinged Right
CR24W COLUMN WINE RESERVE,
SINGLE ZONE
CR24D-1-4L
Wine Reserve, Dual Zone, Glass Overlay Door,
Hinged Le
CR24D-1-4R
Wine Reserve, Dual Zone, Glass Overlay Door,
Hinged Right
CR24D COLUMN WINE RESERVE,
DUAL ZONE
HEAT MAT REQUIREMENTS
FOR MULTI-UNIT
INSTALLATIONS
If installing a freezer side-by-side
with a refrigerator or wine
column, a dual installation kit
(CR-ACC-D1) is required.
The heat mat is installed between
the units to prevent
condensation and does not
require a dedicated outlet.
3
DOOR OVERLAY PANELS
Perlick CR24 column refrigeration comes ready to accept a customer-supplied door overlay panel
and customer-supplied handle. A minimum 5/8" thick panel is required, however, the thickness can
increase provided the panel does not exceed a weight of 65 lbs. The depth of each model is 24"
without a finished overlay, so be sure to allow for panel thickness when planning the finished
opening depth.
This guide includes solid and glass door templates with 4" and 6" toe kicks. Please note that when
installing a panel thicker than 3/4", a 90° stop may be required to prevent damage to both the
unit and surrounding cabinetry.
SOLID DOOR OVERLAY TEMPLATE
FOR 4" TOE KICK
SOLID DOOR OVERLAY TEMPLATE
FOR 6" TOE KICK
OVERLAY CLIP
DETAIL A & B
REVEALS
Reveals between panels can vary — 1/8"
is the minimum. As reveals between
cabinetry and the unit decrease, severe
finger pinching can occur while the
door is closing.
Measurements shown in inches (") Measurements shown in inches (")
14-3/8"
9-3/8"
16-1/8"
7-5/8"
1-3/4"
2-1/4"
12-1/2"
3/8"
A
3/8"
36-1/2"
60-1/2"
Ø 1/8" 1/2" (4X)
79-7/8"
3/8"
Ø 1/8" 1/4" (2X)
6-3/4"
1-11/16"
2-1/16"
11-7/8"
19-5/8"
23-3/4"
2-1/16"
3/4"
14-3/8"
16-1/8"
9-3/8"
7-5/8"
Ø 1/8" 1/2" (4X)
1-3/4"
2-1/4"
12-1/2"
36-1/2"
60-1/2"
B
3/8"
3/8"
3/8"
Ø 3/16" 1/4" (12X)
4-7/8"
1-3/4"
2-1/16"
11-7/8"
19-5/8"
23-3/4"
2-1/16"
3/4"
77-7/8"
Ø 1/8" 1/2" (6X)
Ø 3/16" 1/2" (6X)
Ø 1/8" 1/4" (2X)
4
GLASS DOOR OVERLAY TEMPLATE
FOR 4" TOE KICK
GLASS DOOR OVERLAY TEMPLATE
FOR 6" TOE KICK
C
L
C
L
SCREW ZONE
FOR DOOR OVERLAY
TEMPLATES
Shaded areas (shown right)
should provide enough
thickness for wood screws for
overlay attachment bracket.
Door handle must be
attached to overlay panel
prior to installing panel onto
the unit. Mounting screws for
the handle should be
recessed or countersunk into
the back side of the overlay
panel.
Measurements shown in inches (") Measurements shown in inches (")
Measurements shown in inches (")
16-1/8"
14-3/8"
9-3/8"
7-5/8"
2-1/4"
1-3/4"
12-1/2"
3/8"
36-1/2"
60-1/2"
3/8"
79-7/8"
3/8"
3-3/8"
6-3/4"
1-11/16"
2-1/16"
23-3/4"
19-5/8"
11-7/8"
Ø 1/8" 1/2" (4X)
A
60"
CUTOUT
17" CUTOUT
6-5/8"
3/4"
3/4"
16-1/8"
14-3/8"
9-3/8"
7-5/8"
2-1/4"
1-3/4"
12-1/2"
3/8"
36-1/2"
60-1/2"
3/8"
77-7/8"
3/8"
3-3/8"
4-7/8"
1-3/4"
2-1/16"
23-3/4"
19-5/8"
11-7/8”
Ø 1/8" 1/2" (4X)
6-5/8"
Ø 1/8" 1/2"
(12X)
60"
CUTOUT
17" CUTOUT
Ø 1/8" 1/2" (4X)
Ø 1/8" 1/2" (2X)
Ø 1/8"
1/2" (12X)
23-3/4"
3/4"
3-1/16"
3-1/4"
66"
69-1/2"
3"
11-3/8" 1"
3-1/16"
B
5
INSTALLING PERLICK COLUMN REFRIGERATION
Designed specifically to be integrated into cabinetry, Perlick column refrigeration brings
commercial-grade performance and preservation to any style of kitchen. Columns can be installed
separately, or in side-by-side installations to create custom modular refrigeration.
The following diagrams show various ways to install Perlick column refrigeration and provide
information on producing custom overlay panels.
ADJACENT WALL MINIMUM
CLEARANCE REQUIREMENTS
48"
27-3/4"
ADJACENT WALL
OR STRUCTURE
4-1/8"
27-13/16"
STRUCTURE
CLEARANCE
90° OPEN
STRUCTURE
CLEARANCE
115° FULLY OPEN
If installing column next to adjacent wall,
take care to observe minimum required
clearances to avoid inteference when
opening the door. Regardless of handle, a 2"
clearance is required if door opens towards
a wall. Please note the clearances indicated
are based on a standard 3/4" thick door
panel and Perlick Two Tone Pro Handle
(CR-PRO-HANDLE). Varying door depths
and dimensions of customer-provided
handle may change the required dimensions.
A 90° hinge stop pin (included with unit)
can be installed to prevent the door from
opening beyond 90°. Pin must be installed
prior to full integration. See installation
manual for instructions.
15"
Measurements shown in inches (")
6
OPENING DIMENSIONS FOR A
SINGLE UNIT
Perlick columns allow you the
freedom to install refrigeration
separately anywhere in the kitchen.
Columns are designed to be
integrated into cabinetry, however,
factory installed stainless steel side
panels are available for installations
where the side of the column is
exposed.
47-3/4"
1/4"
A. HANDLE TO HANDLE B. HINGE TO HINGE
C. HANDLE TO HINGE*
1/4"
47-3/4"
49-1/2"
2"
(A & B)
OPENING
(C)
OPENING
48"
84"
12"
10"
12"
84"
49-3/4"
12"
10"
12"
OPENING DIMENSIONS FOR INSTALLING TWO UNITS SIDE-BY-SIDE
Perlick columns can be installed side-by-side in a variety of configurations provided the following
installation specifications are met. Hinge/handle locations and adjacency to walls/structure must
be taken into consideration during the planning process. Choose your desired column
configuration on the left and match to the opening (blue label) drawing on the right for the
proper cutout dimensions (applies to units installed both with or without dual installation kit.)
4"
24"
SIDE
WALL
CABINET
DOOR
FRAME
FACE
Measurements shown in inches (")
90°
*90° HINGE PIN
Doors open to 105°. The
90° hinge pin stop can be
installed. If hinge pin is
installed, all gaps between
cabinets can be 1/2".
If using hinge pins on all
units, refer to Opening
Dimensions A & B.
Measurements shown in inches (")
84"
25"
24"
22-1/8" TO
CABINET
21-9/16" TO
GRILL
83-7/8" TO
TOP OF
OVERLAY
4" - 6"
TOE KICK
3/4" OVERLAY
24-3/4"
OVERALL
24" TO FRONT
OF DOOR FRAME
23-3/4"
OVERALL
7
Visit perlick.com/residential for the latest information on how to install Perlick CR24 column
refrigeration. To purchase Perlick accessories, contact your local Perlick Residential dealer.
© 2019 Perlick Corporation
OPENING DIMENSIONS FOR INSTALLING THREE UNITS SIDE-BY-SIDE
As with dual installations, choose your desired column configuration below and match to the
opening (blue label) drawing for the proper cutout dimensions (applies to units installed both
with or without dual installation kit.)
For installations involving more than three cabinets, combine the opening dimensions for the
openings which correspond to the combined Hinge and Handle combinations shown in this guide.
Measurements shown in inches (")
90°
*90° HINGE PIN
Doors open to 105°. The
90° hinge pin stop can be
installed. If hinge pin is
installed, all gaps between
cabinets can be 1/2".
If using hinge pins on all
units, refer to Opening
Dimensions E.
D. HINGE CONFIGURATIONS
LEFT - LEFT- LEFT
RIGHT - RIGHT - RIGHT
75-1/4"
2"
No cabinets physically joined
together in this conguraon
2"
E. HINGE CONFIGURATIONS
LEFT - RIGHT- LEFT
RIGHT - LEFT - RIGHT
All cabinets physically joined
together in this conguraon
71-3/4"
1/4" 1/4"
F. HINGE CONFIGURATIONS
LEFT - LEFT - RIGHT
RIGHT - RIGHT - LEFT
(2) cabinets physically joined
together in this conguraon
73-1/2"
2" 1/4"
G. HINGE CONFIGURATIONS
RIGHT - LEFT - LEFT
LEFT - RIGHT - RIGHT
(2) cabinets physically joined
together in this conguraon
73-1/2"
1/4" 2"
(D)
OPENING
(E)
OPENING
(F & G)
OPENING
75-3/4"
84"
38"
12"
10"
12"
84"
12"
10"
12"
36-1/2"
72-1/4"
74"
84"
37-1/4"
12"
12"
10"
FORM NO. Z2549
REV. H-09/17/2019
49-1/2"
48"
8
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Perlick CR24D-1-4L User guide

Type
User guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document