Whirlpool AKM 375/IX Program Chart

Type
Program Chart

This manual is also suitable for

AKM 373
PRODUCT DESCRIPTION SHEET
ES PT IT GB
5019 319 61282
Operation of burners with safety device
and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-
clockwise to the large flame and star
setting .
At the same time, hold the knob down until
the burner ignites.
After the burner has ignited, keep the knob
pressed down for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations
described above.
Note:
Should particular local conditions of the
delivered gas make ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
The burner safety device shuts off the gas
supply to the burner if the flame goes out
accidentally (because of a sudden draught,
an interruption in the gas delivery, boiling
over of liquids, etc.).
The separator panel, positioned beneath the
cooktop at a minimum distance of 20 mm,
must be sealed.
1. Removable panstand grids
2-5. Medium burners
3. Large burner
4. Small burner
6. Triple crown burner
7. Small burner control knob
8. Large burner control knob
9. Triple crown burner control knob
10. Medium burner control knob
11. Medium burner control knob
Symbols
Shaded
circle
Tap closed
Large
flame
and star
Maximum opening/delivery
and electric ignition
Small
flame
Minimum opening
or reduced delivery
3gb61282.fm5 Page 1 Friday, September 14, 2001 10:41 AM
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTE: If the distance “A” between the wall cabinets is between 600 mm and 680 mm, the
height “B” must be a minimum of 520 mm.
If the distance “A” between the wall cabinets is greater than the width of the
cooktop, the height “B” must be a minimum of 400 mm.
Before installing a hood above the cooktop please refer to the hood instructions,
which specify the correct distance. In case of installation of an oven under the
cooktop, please refer to the separate oven instructions.
INJECTORS TABLE CATEGORY II2H3+
Type of
gas used
Type of
burner
Injector
marking
Rated heat
capacity
Pcs-kW
Rated
consumption
Reduced
heat
capacity
Pcs-kW
Gas pressure
min. rat. max.
NATURAL GAS
(Methane) G 20
Triple crown
large
medium
small
121+59
128
94
76
3.30
3.00
1.65
1.00
314 l/h
286 l/h
157 l/h
95 l/h
1.50
0.60
0.35
0.30
17 20 25
LIQUID
PETROLEUM GAS
(Cylinder) G 30
Triple crown
large
medium
small
86+37
85
65
50
3.30
3.00
1.65
1.00
240 g/h
218 g/h
120 g/h
73 g/h
1.50
0.60
0.35
0.30
20 28-30 35
LIQUID
PETROLEUM GAS
(Cylinder) G 31
Triple crown
large
medium
small
86+37
85
65
50
3.30
3.00
1.65
1.00
236 g/h
214 g/h
118 g/h
71 g/h
1.50
0.60
0.35
0.30
25 37 45
Type of
gas used
Appliance
model
Total rated heat
capacity
Pcs-kW
Total rated
consumption
Air required for
burning
m
3
/h
G 20 20 mbar 5 gas 10.6 1009 l/h 21.2
G 30 28-30 mbar 5 gas 10.6 771 g/h 21.2
G 31 37 mbar 5 gas 10.6 757 g/h 21.2
3gb61282.fm5 Page 2 Friday, September 14, 2001 10:41 AM
  • Page 1 1
  • Page 2 2

Whirlpool AKM 375/IX Program Chart

Type
Program Chart
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI