4‐Association&AssociationGroupInformation
‐Lifelinebetweencontrollerandtheproduct
‐Supportedcommandclasses
BatteryReport,MultilevelSensorReport,andDeviceResetLocallynotification.
‐AssociationGroupdescription
▶Associationgroup1:Lifelineassociationgroup
Maximumsupportednodeis5
Includecommandclasses:Batteryreport,multilevelsensorreport,andDeviceResetLocally
5‐MultilevelsensorTypeandscale
‐WhenSensordetectsthetemperatureandthehumidity,NotificationReportistransmitted
6‐BatteryReport
‐ BatteryReportistransmittedwhenpoweronthedevice.
‐ BatteryReportistransmittedevery300seconds.
‐ BatteryReportistransmittedwhenthebatterypowerfallslessthan0%
‐
BatteryVoltageBatteryLevel
2.4V~3.0V0%~100(%)
Under2.4V 0xFF
7‐WakeupNotification
‐ WakeupNotificationistransmittedevery300secondsbydefault.
8‐Devicesfrommultiplemanufacturersinonenetwork
‐ ThisproductcanbeincludedandoperatedinanyZ‐Wavenetworkwith
otherZ‐Wavecertifieddevicesfromothermanufacturersand/orother
applicants.Allnon‐batteryoperatednodeswithinthenetworkwillactas
repeatersregardlessofvendortoincreasereliabilityofthenetwork.
9‐Z‐WaveSpecifications
9.1‐DeviceType:Sensor‐Multilevel
9.2‐RoleType:RSS(ReportingSleepingSlave)
9.3‐CommandClassSupport/Control
9.3.1‐Z‐WaveplusInfoVersion2
9.3.2‐AssociationVersion2
9.3.3‐AssociationGroupInfoVersion1
SensorType
Scale
Scalevalue
Temperature (0x01)Celsius(℃)0x00
Humidity(0x05)Percentagevalue0x00