Generac RD03022ADAS User manual

Type
User manual

This manual is also suitable for

4321
4 3 1
A
B
A
B
888 [35.0]
OVERALL WIDTH
1452 [57.2]
OVERALL
HEIGHT
1954 [76.9]
OVERALL LENGTH
182 [7.2]
TYP
324 [12.7]
TYP
1322 [52.0]
TYP
897 [35.3]
DOOR WIDTH
TYP
173 [6.8]
EXHAUST
OUTLET
146 [5.8]
EXHAUST
OUTLET
874 [34.4]
CENTER OF GRAVITY
SERVICE ITEM 2.2L
OIL FILL CAP RIGHT SIDE
OIL DIP STICK RIGHT SIDE
OIL FILTER RIGHT SIDE
OIL DRAIN HOSE RIGHT SIDE
RADIATOR DRAIN HOSE LEFT SIDE
COOLANT RECOVERY BOTTLE LEFT SIDE
RADIATOR FILL CAP ACCESS ROOF
AIR CLEANER ELEMENT RIGHT SIDE
MUFFLER FRONT SIDE
FAN BELT EITHER SIDE
BATTERY LEFT SIDE
WEIGHT DATA WITH EMPTY BASETANK
(SEE NOTE 5)
GENERATOR AS SHOWN 783 [1726]
WITH WOODEN SHIPPING SKID 819 [1806]
TITLE
INSTALL PROTECTOR D2.2L G22
SINGLE WALL TANK
ISSUE DATE: 10/16/19
SIZE CAGE NO DWG NO
A0000442802
REV
BN/A
A
SCALE
0.050 WT-KG SEE ABOVE SHEET 1 of 2
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
SH
1/2 REV A
WINDCHILL VERSION
A.1
AIR INTAKE
(BOTH SIDES)
RADIATOR/EXHAUST
DISCHARGE AIR
(BOTH SIDES)
REFERENCE OWNERS MANUAL FOR
PERIODIC REPLACEMENT PART LISTINGS
NOTES:
1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47") WIDE X 2261 (89") LONG.
REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT
FOR CONCRETE PAD GUIDELINES
2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE
AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT
APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL,
STATE, AND LOCAL CODES.
3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION:
- SEE SPECIFICATION SHEET OR OWNERS MANUAL
- ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF
GENERATOR
4. REMOVE THE REAR TANK AND REAR ENCLOSURE COVER PANEL TO ACCESS
THE STUB-UP AREAS AS FOLLOWS:
- HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION
NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION.
- LOW VOLTAGE CONNECTIONS INCLUDING TRANSFER SWITCH CONTROL WIRES
5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS.
6. ENGINE SERVICE CONNECTIONS
OIL DRAIN: 3/8" NPT
EXHAUST OUTLET: 2" O.D.
7. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND
AND RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW.
8. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS.
9. MOUNTING BOLTS OR STUDS TO CONCRETE PAD SHALL BE 5/8-11 GRADE 5
(USE STANDARD SAE TORQUE SPECS)
WEIGHT: KG [LBS]
DIMENSIONS: MM [INCH]
RADIATOR/EXHAUST
DISCHARGE AIR
REAR ENCLOSURE
COVER PANEL
SEE NOTE 4
CIRCUIT BREAKER
SEE NOTE 3
REMOVABLE
STUB-UP COVER
SEE NOTE 4
CUSTOMER ACCESS
ASSEMBLY, CONTROL
PANEL ACCESS,
BATTERY CHARGER
LOCATED WITHIN,
SEE NOTE 4
REAR VIEW
LIFTING PROVISION (4 PLACES)
SEE NOTES 5, 8 AND CENTER
OF GRAVITY DIMENSIONS
RIGHT SIDE VIEW
VISE ACTION LATCH, ONE PER
DOOR, ONE LIFT-OFF DOOR
PER SIDE OF GENERATOR
OPEN PUNCHED LOUVERS
TYPICAL ON BOTH SIDES OF
FUEL TANK VENTILATION
DUCT TO PROVIDE ADEQUATE
CROSS-FLOW OF AIR
VENTILATION
EXHAUST MUFFLER
ENCLOSED WITHIN
GENERATOR ENCLOSURE
LEFT SIDE VIEW
BATTERY 12 VOLT
NEGATIVE GROUND
REMOVE COVER FOR
ACCESS TO RADIATOR
FILL CAP
TOP VIEW
4321
4 3 1
A
B
A
B
888 [35.0]
851 [33.5]
MOUNTING CENTERS
TYP
19 [.7]
TYP
397 [15.6]
112 [4.4]
TYP 712 [28.0]
TYP
1242 [48.9]
TYP
1842 [72.5]
TYP
1954 [76.9]
250 [9.9]
FUEL TANK
HEIGHT
844 [33.2]
TYP
926 [36.5]
TYP
1045 [41.2]
1196 [47.1]
1430 [56.3]
1690 [66.5]
1555 [61.2]
181 [7.1]
TYP
621 [24.5]
TYP
757 [29.8]
TYP
267 [10.5]
TYP
125 [4.9]
STUB-UP
AREA
125 [4.9]
STUB-UP
AREA
253
[10.0]
51
[2.0]
38
[1.5]
786 [30.9]
850 [33.5]
62 [2.5]
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
TITLE
INSTALL PROTECTOR D2.2L G22
SINGLE WALL TANK
ISSUE DATE: 10/16/19
SIZE CAGE NO DWG NO
A0000442802
REV
BN/A
A
SCALE
0.075 WT-KG SEE ABOVE SHEET 2 of 2
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
SH
2/2 REV A
WINDCHILL VERSION
A.1
FUEL TANK
TOTAL CAPACITY 253.6 [67]
USABLE CAPACITY 230.9 [61]
CAPACITY: LITER [GALLONS]
DIMENSIONS: MM [INCH]
*NOTE: STUB-UP AREA FOR HIGH
AND LOW VOLTAGE CONNECTIONS,
CIRCUIT BREAKER, NEUTRAL AND
CUSTOMER CONNECTION OPENING.
REAR VIEW
16.7 [0.66]
MOUNTING HOLES
(8 PLACES) SEE
NOTE 9
REMOVABLE
STUB-UP COVER
SEE NOTE 4
LEFT SIDE VIEW
REMOVABLE COVER
TOP VIEW
HIGH AND LOW
VOLTAGE STUB-UP
AREA
EMERGENCY VENT
(2" NPT FEMALE)
NORMAL VENT
(2" NPT FEMALE)
FUEL LEVEL
GAUGE/SENDER
FUEL FILL
(2" NPT FEMALE)
FUEL SUPPLY
FUEL RETURN