Native Trails DR560-MB Installation guide

  • Hello! I've reviewed the installation instructions for the NATIVE TRAILS P-Trap DR560. This document outlines the process of assembling and installing the decorative P-Trap, including steps for connecting it to the drain and stub-out. I'm ready to assist you with any questions you might have regarding the installation process, the parts, or the use of the reducing washer for 1.25" drains.
  • What should I do before starting the installation?
    What do I need to do with the Inlet Nut and Washer?
    How should I connect Outlet Tube to the drain stub-out?
BEFORE YOU BEGIN
• Observe all local plumbing and building codes.
• Turn o water supply to sink.
ASSEMBLE THE TRAP
1. Install drain (not included) in sink according to
manufacturer’s instructions.
2. Remove Inlet Nut and Washer from Trap.
3. With threads facing down, slide Inlet Nut and
Washer onto tailpiece of installed drain. For 1.25”
drains, use supplied Reducing Washer.
4. Slide tailpiece of installed drain into top of Trap. Note:
to ensure a proper compression t, tailpiece must
be inserted at least 1” (2.5cm) inside Trap. Then
hand-tighten Inlet Nut until nut is tight against Trap.
CONNECT TO THE STUB-OUT
5. Slide Flange onto long side of Outlet Tube.
6. Place Outlet Tube onto Trap and in to stubout. If Outlet
Tube is too long, use a hacksaw to cut it to appropriate
length.
7. Attach Outlet Tube to Trap by tightening Outlet Nut and
Washer.
8. Attach Outlet Tube to drain stub-out with seal
and nut (not provided). Hand tighten nut to drain
stub-out. Push Flange against nished wall.
9. Ensure all nuts in assembly are tightened properly.
10. Turn on main water supply, run water through
drain and check for leaks.
INSTALLATION INSTRUCTIONS
DECORATIVE P-TRAP DR560
OUTLET TUBE
FLANGE
WASHER
INLET
NUT
TRAP
OUTLET NUT
REDUCING WASHER