Installation
C.2. Electrical connection
Danger
Beforeworkingontheunit,switchothepowersupplyandsecureitfrom
beingswitchedonagain!Checkfortheabsenceofpower!
Electrical connections may only be made by a specialist and in compli-
ance with the applicable regulations.
Donotusethecontrollerifthehousingshowsvisibledamage.
Caution
Low-voltage cables such as temperature sensor cables must be routed
separatelyfromthemainsvoltagecables.Feedtemperaturesensorca-
blesonlyintotheleft-handsideoftheunit,andmainsvoltagecablesonly
into the right-hand side.
Caution
Thecustomermustprovideanall-poledisconnectingdevice,
e.g. a heating emergency switch.
Caution
The cables being connected to the unit must not be stripped by more than
55mm,andthecablejacketmustreachintothehousingjusttotheother
sideofthestrainrelief.
Achtung
FollowtheprotectiveareastoGermanInstituteforStandardizationVDE0100-702for
theinstallationofthecontrol(distancestoSchuztbereich0and1).
Achtung
Electricshockdangerbyimproperconnection!
• VDE-andEVUregulationsoftheenergysupplyenterprisefollow.
• Pumps and swimming pools and their protective area according to
GermanInstituteforStandardizationVDE0100-702instal.
• Dividingdevicefortheinterruptionofthetensioncarewithmin3
mmofcontactopeningperpoolinstal.
Electricshockdangerbytensioninthecase!
• A correctly opposed engine guard counter must be installed. Be-
sides,thevaluesonthetypesignfollow.
• Circuitwithamistakestreamprotectioncounter,nominalmistake
streamI∆N≤30mA.
• Onlysuitablemanagementtypesaccordinglyoftheregionalregula-
tions use.
• Leastcrosssectionofthelines,theenginepowerandtheachieve-
ment situation adapt.
• Ifdangeroussituationscanarise,emergency-fromcounteraccord-
ingtoGermanInstituteforStandardizationEN809plan.According
to this norm the Errichter/operator must decide this.