Bosch HDS7052U/01 Installation guide

Category
Cookers
Type
Installation guide
Freestanding Dual Fuel Range
Quick Finder:
Safety
Preparation
Installation
Final Steps
1
3
5
7
For Use With
Bosch Dual Fuel Ranges
Installation Instructions
Safety Instructions
Preparation
Installation
Final Steps
English • 1
... Our Inspiration
Important Safety Instructions
Please read all instructions before using this appliance.
PARTS PROVIDED:
Anti-Tip Bracket
TOOLS AND PARTS NEEDED:
Range Power Supply Cord Kit with strain relief
(240V - 30 Amps)*
Standard Measuring Tape
Phillips Head Screwdriver
1-1/4” Wrench
Pencil
T-20 Torx Screwdriver
3/8” Nut Driver
Screws (2) and Anchors (2) for Anti-tip Bracket
(Style will vary depending on mounting surface)
Pipe Wrench (2)
Teflon® Tape** or Pipe Joint Compound
(Appropriate for use with LP gas and Natural gas)
Channel Lock Pliers
Gas Leak Test Solution
Level
Drill and Drill Bit
Gas Supply Line (Flexible Metal Appliance Connector
or Rigid Pipe)
Gas Shut Off Valve (If not already present)
Gloves and Safety Goggles
* Not needed for Canadian installations
**
Teflon
is a registered trademark of
DuPont
Table of Contents
Important Safety Instructions .......................................................................................... 1
Preparation ................................................................................................................... 3
Installation .................................................................................................................... 5
Final Steps ................................................................................................................... 7
Remove all tape and packaging before using
the range. Destroy the carton and plastic bags
after unpacking the range. Never allow children to
play with packaging material.
Be sure your appliance is properly installed
and grounded by a qualified technician in
accordance with the National Electrical Code ANSI/
NFPA No. 7 latest edition and local electrical code
requirements.
Important: Local codes vary. Installation, electrical
connections and grounding must comply with all
applicable codes.
Install only per installation instructions
included in the literature package for this
range.
Ask your dealer to recommend a qualified
technician and an authorized repair service.
Know how to disconnect the power to the
range at the circuit breaker or fuse box in and the
gas supply at the shutoff in case of an emergency.
Do not repair or replace any part of the
appliance unless specifically recommended in
the manuals. All other servicing should be done by
a qualified technician. This may reduce the risk of
personal injury and damage to the range.
When testing the supply piping system at test
pressures in excess of 1/2 psig (3.5 kPa), the
appliance and its individual shutoff valve must
be disconnected from the gas piping system.
When testing the supply piping system at test
pressures equal to or less than 1/2 psig (3.5
kPa), the appliance must be isolated from the
gas supply piping system by closing its
individual manual shutoff valve.
Never modify or alter the construction of a
range by removing leveling legs, panels, wire
covers, anti-tip brackets/screws, or any other part
of the product.
Do not lift door by door handle. Remove the
door for easier handling and installation. See
Section ‘Removing Oven Door’ in Use and Care
manual.
Do not store or use combustible materials,
gasoline or other flammable vapors and
liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by a
qualified installer, authorized service agency or the
gas supplier.
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or death.
WARNING
Safety Instructions
Preparation Installation
Final Steps
English • 2
Your Life ...
This appliance has been tested in accordance with the
following standards:
ANSI Z21.1, Standard for Household Cooking
Appliances (USA)
CAN 1.1-M81 Interim Reqt # 58 Domestic Cooktops
(CANADA)
CAN/ CSA-C 22.2 No. 61-M89 Household Cooking
Ranges
In Canada, installation must be in accordance with CAN
1-B149.1 and .2 Installation Codes for Gas Burning
Appliances and/or local codes.
For Massachusetts Installations:
1.Installation must be performed by a qualified or
licensed contractor, plumber or gas fitter qualified
or licensed by the state, province or region where
this appliance is being installed.
2.Shutoff valve must be a “T” handle gas cock.
3.Flexible gas connector must not be longer than 36
inches.
IMPORTANT SAFETY INSTRUCTIONS
Unit is heavy and requires at least two persons or
proper equipment to move.
CAUTION
Before installing, turn power OFF at the service
panel. Lock service panel to prevent power from
being turned ON accidentally.
WARNING
WARNING
Stepping, leaning or sitting on the doors or drawers
of this range can result in serious injuries and also
cause damage to the range. Do not allow children to
climb or play around the range. The weight of a child
on an open door may cause the range to tip,
resulting in serious burns or other injury.
CAUTION
Do not use the oven or warming drawer (if equipped)
for storage.
WARNING
Do not store items of interest to children in the
cabinets above the range or on the backguard of a
range. Children climbing on the range to reach items
could be seriously injured.
High Altitude Installation Note:
This range is CSA certified for safe operation up to an
altitude of 10,000 ft. without any modifications.
Exception: for use with LP, the range must first be
converted using the LP conversion instructions included
in this literature package.
All ranges can tip and injury could result. To
prevent accidental tipping of the range,
attach it to the wall, floor or cabinet by
installing the Anti-Tip Device supplied.
A risk of tip-over may exist if the appliance is
not installed in accordance with these
instructions.
If the range is pulled away from the wall for
cleaning, service, or any other reason, ensure
that the Anti-Tip Device is properly
reengaged when the range is pushed back
against the wall. In the event of abnormal
usage (such as a person standing, sitting, or
leaning on an open door), failure to take this
precaution could result in tipping of the
range. Personal injury might result from
spilled hot liquids or from the range itself.
WARNING
RANGE TIPPING HAZARD
Safety Instructions
Preparation
Installation
Final Steps
English • 3
... Our Inspiration
Steps 1 through 4: Preparation
Figure 1: Cabinet Preparation
30” Minimum
Centered
30”
Min.
4” Min.
4” Min.
18”
Min.
No Clearance to
Cabinet Wall
Required **
Figure 2: Gas Supply Line and Electrical Outlet Placement
7 1/2"
4 1/2"
13 1/8 "
4"
3 7/8"
4 1/2"
3 1/2"
30"
Place Gas Supply
Line and Electrical
Outlet Here
7 1/2”
4 1/2”
13 1/8”
4” 3 7/8”
3 1/2”
4 1/2”
30”
Figure 3
1 9/16”
Flush
Cabinet Sidewall
Anti-Tip Device
Backwall
1. Install Ventilation
Bosch strongly recommends the installation of a
ventilation hood above this range. For most kitchens a
certified hood rating of not less than 300 CFM is
recommended. The range hood must be installed
according to instructions furnished with the hood.
2. Prepare Cabinets
This unit is designed for installation near adjacent walls
and projecting surfaces constructed of combustible
materials.
Allow a minimum of 30 inches between cabinets where
range is to be installed (See Figure 1)**.
Required Clearances*
From cooktop to materials above (See Figure 1)
There must be a minimum clearance of 30 inches
between the top of the cooking surface and the bottom
of an unprotected wood or metal cabinet.
24 inches is acceptable when the bottom of the wood or
metal cabinet is protected by (a) not less than 1/4" of
flame retardant material which must be covered with
(b) not less than No. 28 MSG sheet metal, 0.015 inch
stainless steel’ or 0.024 inch aluminum or copper.
From range walls to adjacent materials
(See Figure 1)
No clearance is required from unit walls to adjacent
vertical combustible walls on rear, right or left.
Clearance from range top to adjacent vertical walls
must be at least 4”.
NOTE: Some cabinet finishes cannot survive the
temperatures allowed by U.L., particularly self-cleaning
ovens; the cabinets may discolor or stain. This is most
noticeable with laminated cabinets.
3. Prepare Gas Supply Line and
Electrical Outlet
The gas supply line and electrical outlet must be located
in the shaded space in Figure 2.
4. Prepare Walls and Floor
Seal any holes in the walls or floor. Remove any
obstructions (extra electrical or gas connections, etc.) so
that range will rest against wall properly.
*Instructions were determined using standard American cabinets. Standard base cabinets measure 36" high x 24" deep . Cabinets over
the cooking surface and cabinets adjacent to those over the cooking surface measure 13 inches deep from backwall. If nonstandard
cabinets are used, care should be taken to alter dimensions accordingly.
** 12 mm clearance from range sidewall to cabinet required in Canada.
Install Anti-Tip Bracket
1. Adjust height of range and level by rotating the
adjustable leg supports on the bottom of the
range, using 1-1/4" wrench.
2. Measure to locate bracket position as shown in
Figure 8.
3. Secure bracket with 2 screws adequate for
mounting surface, not included. (i.e.; for wood
floor use wood screws, for concrete floor use
concrete anchors and screws.).
Tips:
Tape warming drawer shut to keep it from opening
while installing the range.
During installation, place a portion of the box or a
piece of cloth under the range to protect floors.
To make range lighter and easier to handle, remove
door (see instructions in Use and Care manual).
Safety Instructions
Preparation Installation
Final Steps
English • 4
Your Life ...
Step 5: Prepare Electrical Connection
Install Strain Relief
Place strain relief in knockout below terminal block (See
Figure 4). Feed range cord through hole and strain relief
up to terminal block. Allow for slack in the cord between
the strain relief and terminal block. Once cord length/
slack has been adjusted, attach strain relief per
instructions included with strain relief.
TIP
The knockout panel below the terminal block can be
removed from the range to install the strain relief:
Remove knockout panel from range, install strain
relief in panel and reattach. DO NOT remove entire
range back panel.
Verify that wiring to house is adequate.
Contact your local utility company to verify that the present
electric service to your home is adequate. In some
instances, the size of the wiring to the house and service
switch must be increased to handle the electrical load
demanded by the range.
Verify that wiring inside house is adequate.
Most wiring codes require a separate circuit with separate
disconnect switch and fuses either in the main entrance
panel or in a separate switch and fuse box.
The range requires a three wire 120/240 or 120/208 volt,
30 AMP, 60 Hz AC circuit.
Most local building regulations and codes require that
electrical wiring be done by licensed electricians. Be sure
to install your range according to the electric codes in
place in your region.
General Information
Bosch recommends that the range be installed with a
power cord set (not supplied)*. The electrical rating of the
power cord set must be 120/240 volt, 30 amperes
minimum. The power cord set shall be marked “For Use
with Ranges.” Always use a new power cord.
Note: In Canada, the range is shipped from the factory
with the range cord already installed. Proceed to “Step 7:
Installation - Connect the Gas Supply)
For installations other than those in Canada, connect the
range cord at the terminal block (See next page for
detailed instructions). Access the terminal block by
removing the cover in the lower right hand corner of the
range back panel (See Figure 4). Install the strain relief
(see next column) and the proper connector through the
knockout(s) provided. The electrical supply, including
flexible conduit or power cord, should be restricted to the
shaded areas in Figure 2 (previous page)
WARNING
The strain relief provided with your range
cord must be properly installed.
To prevent electrical shock, the grounding
prong on the range cord should not be cut or
removed under any circumstances. It must be
plugged into a matching grounding type receptacle and
connected to a correctly polarized 240- Volt circuit. If
there is any doubt as to whether the wall receptacle is
properly grounded, have it checked by a qualified
electrician.
Figure 4
Electric Connection (found
behind terminal block
cover)
Gas Connection
Feed
Range
Cord
Through
Strain
Relief in
Knockout
Panel
Here
Figure 5
WARNING
Risk of Electric Shock or Fire. Frame grounded to neutral
through a ground strap. Grounding through the neutral
conductor is prohibited for new branch-circuit installations
(1996 NEC), mobile homes, and recreational vehicles, or in an
area where local codes prohibit grounding through the neutral
conductor.
For installations where grounding through the neutral
conductor is prohibited, (a) disconnect the link from the neutral,
(b) use grounding terminal or lead to ground unit, (c) connect
neutral terminal to lead branch circuit neutral in usual manner
(when the appliance is to be connected by means of a cord kit,
use 4-conductor cord for this purpose).
Use only cord kits rated 125/250 volts (minimum), 30 amperes
and labeled “For Use with Ranges”. Strain relief provided with
cord must be installed per instructions included with cord.
5. Prepare Electrical Connection
Ranges are dual rated for use on either 120/240 VAC or
120/208 VAC. See chart below for power ratings and
circuit breaker sizes based on the supply voltage for
each model.
CAUTION:
Make certain that gas shutoff valve and all burner
controls are in the OFF position before beginning
MODEL: HDS
VOLTS HZ RATING CIRCUIT
A.C. KW BREAKER
120/240 60 6.5 30 AMPS
120/208 60 4.8 30 AMPS
* Not needed for Canadian installations
Safety Instructions
Preparation
Installation
Final Steps
English • 5
... Our Inspiration
Figure 9
Figure 10
Figure 8
Figure 7
Figure 6
Note: DO NOT plug in range at this time. Proceed
to step 7, next page.
Step 6: Installation - Connect Electric
White
Red
Black
Ground Strap
Green Ground Screw
Ground
Strap
Green
Red
White
Black
Red
White
Black
Ground
Strap
Green Ground Screw
Three Wire Connection
The Four Wire Connection is preferred, but where
local codes and ordinances permit grounding through
neutral and/or conversion to four wire is impractical,
unit may be connected to the power supply via a three
wire connection.
1. Disconnect electrical power at breaker box.
2. Remove the terminal block cover to expose the
terminal block (See Figure A).
3. Remove top nut, star washer, and round washer
from each post.
Note: DO NOT remove last round washer, last nut or
internal wiring leads.
4. Attach white wire, round washer, star washer and
nut IN THIS ORDER on top of ground strap on
center post.
5. Attach red wire, round washer, star washer and
nut IN THIS ORDER to left post.
6. Attach black wire, round washer, star washer and
nut IN THIS ORDER to right post (See Figure B).
7. Tighten all connections securely and replace
terminal block cover (See Figure C).
8. Properly secure strain relief (see previous page).
Four Wire Connection (Preferred to three wire connection).
1. Disconnect electrical power at breaker box.
2. Remove the terminal block cover to expose the
terminal block (See Figure A).
3. Remove top nut, star washer, and round washer
from each post.
Note: DO NOT remove last round washer, last nut or
internal wiring leads.
4. Remove screw from bottom end of ground strap.
5. Remove ground strap from center post, rotate so
that wide end is at top and attach wide end to
range through hole below junction box. Attach
green wire on top of ground strap. Tighten Screw
(See Figure D).
6. Attach red wire, round washer, star washer and
nut IN THIS ORDER to left post.
7. Attach white wire, round washer, star washer and
nut IN THIS ORDER to center post.
8. Attach black wire, round washer, star washer and
nut IN THIS ORDER to right post (See Figure E).
9. Tighten all connections securely and replace
terminal block cover.
10. Properly secure strain relief (see previous page).
Safety Instructions
Preparation Installation
Final Steps
English • 6
Your Life ...
The gas connection is located below the back panel of
the range (See Figure 4, Page 4). It is accessible
through the warming drawer access panel or from the
back of the range. To reach access panel, remove
warming drawer.
Shut off main gas supply valve before disconnecting the
old range and leave it off until the new hook-up has
been completed. Don’t forget to relight the pilot on
other gas appliances when you turn the gas back
on.
The range can be installed using rigid pipe or a CSA
International-certified flexible metal appliance connector.
If using a flexible connector, always use a new
connector.
Apply pipe joint compound or Teflon** tape appropriate
for use with LP gas and Natural gas around all male pipe
threads to prevent leaks.
If not already present, install gas shut off valve in an
easily accessible location. Make sure all users know
where and how to shut off the gas supply to the range.
Note: The installer should inform the consumer of
the location of the gas shutoff valve.
Step 7: Installation - Connect Gas Supply
Flexible Connector Method
(see Figure 11, this page)
1. Install male 1/2” flare adaptor at the 1/2” NPT
internal thread of the range inlet. Use a backup
wrench on the elbow fitting to avoid damage.
2. Install male 1/2” or 3/4” flare union adapter on the
NPT internal thread of the manual shutoff valve.
3. Connect flexible metal appliance connector.
4. Make sure circuit breaker is off and then plug range
cord into electrical outlet.
5. Push range back into position insuring that range leg
slides under the anti-tip bracket. The range will sit
3/4” away from the wall when properly installed.
Note: Be careful not to crimp flexible connector!
6. Carefully tip range forward to ensure that anti-tip
bracket engages and prevents tip-over.
Important note for LP users: The range is
shipped from the factory for use with natural gas.
For use with propane (LP) gas, your range must first
be converted using the LP conversion kit.
Figure 11: Flexible Connector Method
Gas Shut-
Off Valve
Flexible
Connector
Regulator
Proceed to “Test for Gas Leaks”, next column.
Test for Gas Leaks
Leak testing is to be conducted by the installer according
to the instructions given in this section.
Turn on Gas. Apply a non-corrosive leak detection fluid
to all joints and fittings in the gas connection between
the shutoff valve and the range. Include gas fittings and
joints in the range if connections may have been
disturbed during installation. Bubbles appearing
around fittings and connections indicate a leak.
If a leak appears, turn off supply line gas shutoff valve
and tighten connections. Retest for leaks by turning on
the supply line gas shutoff valve. When leak check is
complete (no bubbles appear), test is complete. Wipe
off all detection fluid residue. Proceed to Steps 8A and
8B: Final Steps.
gas shut off valve
elbow
nipple
nipple
nipple
union
elbow
1/2” to 3/4”
gas pipe
Gas Flow to Range
Figure 12: Rigid Pipe Method
elbow:
connect to
regulator here
Rigid Pipe Method
(see Figure 12, this page)
The configuration of the rigid pipe connection will vary
depending on the location of the gas pipe stub. Refer to
Figure 12 for details.
1. Make sure circuit breaker is off and then plug range
cord into electrical outlet.
2. Push range back into position ensuring that range
leg slides under the anti-tip bracket. The range will
sit 3/4” away from the wall when properly installed.
3. Carefully tip range forward to ensure that anti-tip
bracket engages and prevents tip-over.
4. Connect pipe to range at union. Access the
connection through the access panel behind the
warming drawer.
Note: Be careful not to apply pressure to warming
drawer element during rigid pipe installation.
Before you plug in an electrical cord, be sure all
controls are in the OFF position.
CAUTION
NEVER CHECK FOR LEAKS WITH A FLAME.
DO NOT CONTINUE TO THE NEXT STEP UNTIL ALL
LEAKS ARE ELIMINATED.
CAUTION
**
Teflon
is a registered trademark of
DuPont
Safety Instructions
Preparation
Installation
Final Steps
English • 7
... Our Inspiration
Replacement Parts: Visit your Bosch dealer for replacement parts. For a dealer near you contact Bosch Service
at 800-944-2904.
Step 8: Test the Installation
8A. Test Electric Ignition
Turn on power at breaker.
8B. Test/Adjust Flame
High Setting:
The combustion quality of the flame for each burner
must be visually inspected. For propane, the flame
should be blue with yellow tips. For natural gas, it
should be soft blue in color. The flame should carry over,
or surround, the entire burner and should not lift or
blow off the burner.
To inspect, turn the burner on. See Figure 13 for
appropriate flame characteristics.
If the flame is completely or mostly yellow, verify that
the regulator is set for the correct fuel. After
adjustment, retest. If any of the burners continue
to burn mostly or completely yellow, call Bosch
Service 800-944-2904.
Note: With LP use, some yellow tipping on outer cones
is normal.
Low Setting
All burners must also be inspected for carry-over. On
low, the flame should completely surround the burner. If
any of the cooktop burners do not carry over on
the low setting, call Bosch Service 800-944-2904.
Installation is complete at this time.
Flame Characteristics
Figure 13
Yellow Flames:
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LP Gas.
Soft Blue Flames:
Normal for Natural Gas.
Some yellow streaking is normal during the
initial start-up.
Allow unit to operate 4-5 minutes and
reevaluate before making adjustments.
WHEN PROPERLY ADJUSTED:
There should be a flame at each burner
port.
There should be no air gap between the
flame and burner.
Caution:
If the display flashes and beeps, the polarity of the
wiring may be reversed. Reversed polarity can
damage the range and can result in electrical shock
hazard. Immediately switch off power at the breaker
and return to step 6.
Select a rangetop burner knob. Push down and turn to
the flame symbol. If the ignitor/spark module is
operating correctly, it will produce a clicking sound.
Once the air has been purged from the supply lines, the
burner should light within four (4) seconds. After burner
lights, turn knob to the off position.
Test each rangetop burner in this fashion.
Call Bosch Service at 800-944-2904 if any of the
burners do not light.
BSH reserves the right to change specifications or design without notice. Some models are certified for use in Canada. BSH is not responsible for
products which are transported from the United States for use in Canada. Check with your local Canadian distributor or dealer. BSH Home
Appliances Corporation, 5551 McFadden Avenue, Huntington Beach, CA 92649.
For the most up to date critical installation dimensions by fax, use your fax handset and call 702/833-3600. Use code #8030.
5551 McFadden Avenue, Huntington Beach, CA 92649 • 800-944-2904.
5060003403 Rev. B (ECO# 5V02EM, 5V026Q) 05/04 • © BSH Home Appliances Corporation 2004 • Litho U.S.A.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Bosch HDS7052U/01 Installation guide

Category
Cookers
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI