Bosch DHU935HME/02 Operating instructions

Category
Cooker hoods
Type
Operating instructions
en Operating Instructions
fr Mode d’emploi
ru Басқару нұсқаулары
kk Инструкция по эксплуатации и техобслуживанию
bm Arahan Pengendalian
ar
DHU...
ϡ΍ΩΧΗγϼϟ ΕΎϣϳϠόΗ
Operating Instructions 8
Installation Instructions 13
Notice d’utilisation 17
Notice de montage 22
Инструкция по эксплуатации 26
Инструкция по монтажу 31
Басқару нұсқаулары 35
Орнату нұсқаулары 40
Arahan Pengendalian 44
Arahan Pemasangan 49
Ηϡ΍ΩΧΗγϼϟ ΕΎϣϳϠό
ΕΎϣϳϠόΗΏϳϛέΗϠϟ
53
60
6
Exhaust
Supply cord
Tuyau
Câble d’alimentation
ВЫПУСК
ШНУР ПИТАНИЯ
ϡΩΎόϟ΍
ϚϠγΪϳϭΰΘϟ΍
8
Before using for the first time
Important notes:
The Instructions for Use apply to several
versions of this appliance. Accordingly,
you may find descriptions of individual
features that do not apply to your specific
appliance.
This extractor hood complies with all
relevant safety regulations.
Repairs should be carried out by qualified
technicians only.
Improper repairs may put the user at
considerable risk.
Before using your appliance for the first
time, please read these Instructions for
Use carefully. They contain important
information concerning your personal
safety as well as on use and care of the
appliance.
Please retain the operating and installa-
tion instructions for a subsequent owner.
Dispose of packaging materials properly
(see Installation instructions).
This extractor hood is designed for do-
mestic use only.
Before any cleaning or maintenance op-
eration, disconnect the hood from the mains
by removing the plug or disconnecting the
home mains switch.
The appliance is not intended for use by
children or persons with impaired physical,
sensorial or mental faculties, or if lacking in
experience or know-how, unless they are un-
der supervision or have been trained in the
use of the appliance by a person responsible
for their safety.
Children should be monitored to ensure
that they do not play with the appliance.
Never use the hood without effectively
mounted grating.!
The hood must NEVER be used as a
support surface unless specifically indicated.
The premises must be sufficiently
ventilated, when the kitchen hood is used
together with other gas combustion devices
or other fuels.
Description of appliance
Operating modes
Exhaust-air mode:
The extractor-hood fan extracts the
kit-chen vapours and conveys them
throughthe grease filter into the atmos-
phere.
The grease filter absorbs the solid parti-
cles in the kitchen vapours.
The kitchen is kept almost free of grease-
and odours.
Circulating-air mode:
An activated carbon filter must be fittedfor
this operating mode (see Filters andmain-
tenance). The activated carbon filter can be
purchased as an optional accessory FROM
YOUR DEALER.
The extractor-hood fan extracts the kitchen
vapours which are purified in the grease
filter and activated carbon filter and then
conveyed back into the kitchen.
The grease filter absorbs the grease parti-
cles in the kitchen vapours.
The activated carbon filter binds the odor-
ous substances.
If the extractor hood is switched fromex-
haust-air mode to circulating-air mode,the
exhaust-air opening must be sealed topre-
vent a hazardous situation (see optionalac-
cessories in the Instructions for use).
Operat
i
ng Instruct
i
ons
9
Before using for the first time
Gas stoves and electric stoves
Do not use a gas hob with all the stoves
on and top-powered for more than 15 mi-
nutes, otherwise the surface of the cooker
hood might risk overheating, thus causing
burns in case of contact with the hood.
Furthermore the cooker hood might get
damaged.
In case more than 3 gas stoves are used,
the cooker hood must be used at top
power.
Important: a big stove having power hi-
gher than 5 KW (type WOK) corresponds
to 2 standard stoves.
Never use the gas stoves without any
pots. Adjust the flame so that it does not
exceed the perimeter of the pot.
Do not use or leave the hood without the
lamp correctly mounted because of the pos-
sible risk of electric shocks.
We decline any responsibility for any
problems, damage or fires caused to the ap-
pliance as the result of the non-observance
of the instructions included in this manual.
Operating Instructions
The suctioned air must not be conveyed
into a conduit used for the disposal of
the fumes generated by appliances that
combust gases or other fuels.
The flaming of foods beneath the hood
itself is severely prohibited.
The use of exposed flames is detrimental
to the filters and may cause a fire risk,
and must therefore be avoided in all circu-
mstances.
Any frying must be done with care in
order to make sure that the oil does not
overheat and burst into flames.
As regards the technical and safety mea-
sures to be adopted for fume discharging
it is important to closely follow the rela-
tions provided by the competent authori-
ties.
The hood must be regularly cleaned on
both the inside and outside (AT LEAST
ONCE A MONTH, it is in any event neces-
sary to proceed in accordance with the
maintenance instructions provided in this
manual)..
Failure to follow the instructions as con-
cerns hood and filter cleaning will lead to
the risk of fires.
10
Operating the extractor hood Filters and maintenance
ATTENTION! Before performing any
maintenance operation, isolate the hood
from the electrical supply by switching
off at the connector and removing the
connector fuse.
Or if the appliance has been connected
through a plug and socket, then the plug
must be removed from the socket.
Grease Filter
Different grease filters can be used to
absorb the grease particles in the kitchen
vapours.
Fleece grease filter:
The filter mat consists of highly flammable
material.
Warning:
A build up of greasy residue increasesflam-
mability, and the function of the extractor
hood may be impaired.
Important:
Replace the fleece grease filter in good
time,otherwise there is a risk of fire from the
heat which accumulates during deep-fat fry-
ing or roasting.
Replacing the fleece grease filter:
During normal operation (daily 1 to
2hours) the fleece grease filter must be
replaced every 8 to 10 weeks.
Replace printed fleece grease filters
atthe latest when the coloured print dis-
solves.
Use only original filters.These comply
with the safety regulation sand ensure
optimum function.
Disposal of the old fleece grease filter:
Fleece grease filters do not contain
anyharmful substances. They can be
disposed of as bio-degradable waste.
Removing and installing the fleece grease
filter:
1. Press in the interlocks on the left andright
sides of the filter grille. Fig. 1/1.
2. Remove the filter grille. Fig. 1/2.
A Fan setting
B Light ON/OFF
A
B
11
metal filter. Fig. 2.
4. Clean the filter grille and the metal filter.
5. Re-insert the cleaned metal filter and-
clamp them with the wire grille. Fig. 2.
6. Re-insert the filter grille. Fig. 1/2.
The interlocks must lock into positionon
the left and right sides. Fig. 2/1.
Activated carbon filter:
For binding the odorous substances in
circulating-air mode.
Installing:
1. Press in the interlocks on the left andright
sides of the filter grille. Fig. 1/1.
2. Remove the filter grille. Fig. 1/2.
3. Insert the activated carbon filter from
below into the extractor-hood housing
and lock into position and turned clockwi-
se.(fig.3)
4. Re-insert the filter grille. Fig. 1/2.
The interlocks must lock into positionon the
left and right sides. Fig. 1/1.
Removing:
The activated carbon filter is removed inre-
verse sequence.
Replacing the activated carbon filter:
During normal operation (daily 1 to
2hours) the activated carbon filter must be
replaced approximately 1 x year.
The activated carbon filter can be pur-
chased FROM YOUR DEALER.
Use only original filters.
These ensure optimum function.
Disposal of the old activated carbon filter:
Activated carbon filters do not contain
any harmful substances. They can be
disposed of as residual waste.
3. Remove the wire grille and the saturated-
filter mat. Fig. 2.
4. Clean the filter grille and insert a new filter
mat Fig. 2.
5. Clamp the filter mat with the wire grille.
Fig. 2.
6. Re-insert the filter grille. Fig. 1/2.
The interlocks must lock into positionon
the left and right sides. Fig. 1/1.
Metal grease filter:
The filter mats consist of non-flammable
material.
Warning:
A build up of greasy residue increases flam-
mability, and the function of the extractor
hood may be impaired.
Important:
Replace the metal grease filter in good
time,otherwise there is a risk of fire from the
heat which accumulates during deep-fat fry-
ing or roasting.
Cleaning the metal grease filter:
During normal operation (daily 1 to
2hours) the metal grease filter must be
replaced every 8 to 10 weeks.
The metal grease filter can be cleaned
inthe dishwasher.
Slight discoloration may occur.
Important:
Do not clean heavily saturated metal-
grease filters with other dishes.
If cleaning by hand, soak the grease
filters in a hot soapy solution.
Then brush off any residual grease, rinse
thoroughly and leave to dry.
Use only original filters.
These ensure optimum function.
Removing and installing the metal filter:
1. Press in the interlocks on the left andright
sides of the filter grille. Fig. 1/1.
2. Remove the filter grille. Fig. 1/2.
3. Remove the wire grille and the saturated-
Filters and maintenance
12
Isolate the extractor hood by pulling out-
the mains plug or switching off the fuse.
When cleaning the grease filters, remove
grease deposits from the accessible side
of the housing.
This will prevent a fire hazard and willen-
sure optimum function.
Clean the extractor hood with a hot soapy
solution or with a mild window cleaning
agent.
Do not scratch off dried-on dirt, but wipe
off with a moist cloth.
Do not use any abrasive cleaning agents
or scouring sponges.
Note: Do not apply alcohol (spirit) to pla-
stic surfaces, as they may tarnish.
Caution! Provide adequate ventilation in
the kitchen. No naked flames.
Clean the switch only with a soft, moist
cloth (mild soapy solution).Do not clean
the switch with a stainless-steel cleaning
agent.
Stainless-steel surfaces:
Use a mild, non-abrasive stainless-steel-
cleaning agent.
Clean only in the direction of the ground-
surface.
Do not clean stainless-steel surfaces
with scouring sponges or with cleaning
agents containing sand, soda, acid or
chlorides!
Replacing the lamps
Warning! Prior to touching the light bulbs
ensure they are cooled down.
1. Switch off the extractor hood and isolate
the extractor hood by pulling out the
mains plug or switching off the fuse.
2. Remove the grease filter
(see Filters and maintenance).
3. Replace the lamp (commercially avail-
able candle lamps, max. 40 watts, E14
lampholder). Fig. 4.
4. Reconnect the power by inserting the
mains plug or by switching on the fuse.
Malfunctions
Please contact customer service regarding
any queries or malfunctions.
When calling, please quote:
E-No. FD
Enter the numbers in the above box. The-
numbers can be found on the rating plate
–remove the grease filter inside the extractor
hood to reveal the rating plate.
Cleaning and care
13
Before installation
If the instructions for installation for the
gas hob specify a greater distance, this must
be adhered to.
Additional information for gas coo-
king appliances:
Comply with the currently valid instal-
lation regulations and the installation
instructions supplied by the gas appliance
manufacturers.
The extractor hood may be installed with
only one side next to a high-sided unitor a
high wall. Min. gap 50 mm.
The extractor hood must be installed at
a minimum distance of 650 mm above
gas hotplates – Fig. 5 – provided the
fol-lowing nominal heat loads (Hs) are
notexceeded:
Gas cookers
Load of one hotplate max. 03.0 kW
Load of all hotplates max. 08.3 kW
Load of oven max. 03.9 kW
Gas hobs
Load of one hotplate max. 03.9 kW
Load of all hotplates max. 11.3 kW
Gas ceramic hob
The specifications for nominal heat load
do not apply to closed gas ceramich obs.
Always comply with the specifications of
the hotplate manufacturer.
The smaller the distance between the
extractor hood and hotplates, the greater
the likelihood that rising water vapour will
condense under the extractor hood.
The extractor hood may only be installed
over a fireplace which burns solidfuel
(fire hazard due to flying sparks) if the
fireplace has a closed, non-detachable
cover and national regulations have been
observed. This restriction does not apply
to gas cookers and gas hobs.
Important information
Old appliances are not worthless rubbish.
Valuable raw materials can be reclaimed by
recycling old appliances.
Before disposing of your old appliance, ren-
der it unusable.
This appliance is marked according to the
European directive 2002/96/EC on Waste
Electrical and Electronic Equipment (WEEE).
By ensuring this product is disposed of
correctly, you will help prevent potential
negative consequences for the environment
and human health, which could otherwise be
caused by inappropriate waste handling of
this product.
The symbol
on the product, or on the
documents accompanying the product, indi-
cates that this appliance may not be treated
as household waste. Instead it should be
taken to the appropriate collection point
for the recycling of electrical and electronic
equipment. Disposal must be carried out in
accordance with local environmental regula-
tions for waste disposal.
For more detailed information about treat-
ment, recovery and recycling of this product,
please contact your local council, your hou-
sehold waste disposal service or the shop
where you purchased the product.
You received your new appliance in a
protective shipping carton.
All packaging materials are environmentally
friendly and recyclable.
Please contribute to a better environment
by disposing of packaging materials in an
environmentally-friendly manner.
Please ask your dealer or inquire at your
local authority about current means of
disposal.
The extractor hood can be used in
exhaust air or circulating air mode.
Always mount the extractor hood over the
centre of the hob.
The minimum distance between the
supporting surface for the cooking vessels
on the hob and the lowest part of the range
hood must be not less than 50cm from
electric cookers and 65cm from gas or mixed
cookers. Fig. 1
Installation Instructions
14
Exhaust-air mode - Fig. 6
The exhaust air is discharged upwards throu-
gh a ventilation shaft or directly through the
outside wall into the open.
For operating in exhaust-air mode, a one-
way flap should be mounted inside the wall
ventilation box.
If no one-way flap was enclosed with the
hood, it can be obtained from a specialist
retailer.
If the exhaust air is going to be discharged
into the open, a telescopic wall box should
be fitted into the outside wall Fig. 7.
For optimum extractor hood efficiency:
Short, smooth air exhaust pipe.
As few bends in the pipe as possible.
Diameter of pipe to be as large as possi-
ble and no tight bends in pipe.
If long, rough exhaust-air pipes, many
pipe bends or smaller pipe diameters are
used, the air extraction rate will no longer
be at an optimum level and there will be
an increase in noise.
Round pipes:
We recommend Internal diameter:
100 mm
Flat ducts must have an internal cross
section that equates to that of round
pipes.
There should be no sharp bends.
Ø 100 mm approx. 178 cm2 .
If pipes have different diameters:
Insert sealing strip.
For exhaust-air mode, ensure that there is
an adequate supply of fresh air.
Exhaust air upwards:
Pipe diameter: 100 mm
Take care that the air-deflector is
fitted(Fig.8/1).
Insert the exhaust-air connection(Fig.8/2)
Exhaust air towards the rear:
Pipe diameter:100 mm
Take out the air-deflector Fig. 8/1.
Insert the exhaust-air connection(Fig.8/3)
Close top exit with supplied jerk(Fig.8/3).
Circulating-air mode Fig. 9
(If there is no exhaust-air mode option)
The air purified by an additional activated
carbon filter is conveyed back into the
room.
For insertion of the activated carbon filter
see Instructions for use.
If the extractor hood is switched from
exhaust-air mode to circulating-airmode,
the exhaust-air opening must be sealed to
prevent a hazardous situation.
Before installation
15
Electrical connection
The appliance features an EU safety plug.
To ensure protective earthing in a Danish
socket, the appliance must be connected to
a suitable plug adapter. This adapter (per-
mitted up to max. 13 amps) is available from
customer service (spare part no. 616581).
The mains power supply must correspond
to the rating indicated on the plate situa-
ted inside the hood. If provided with a plug
connect the hood to a socket in compliance
with current regulations and positioned in
an accessible area. If it not fitted with a plug
(direct mains connection) or if the plug is not
located in an accessible area apply a bi-polar
switch in accordance with standards which
assures the complete disconnection of the
mains under conditions relating to over-cur-
rent category III, in accordance with installa-
tion instructions.
Warning! Before re-connecting the hood
circuit to the mains supply and checking
the efficient function, always check that the
mains cable is correctly assembled.
Warning! Power cable replacement must be
undertaken by the authorized service assi-
stance centre or similar qualified person.
Connect the hood to a norm complying plug
only. The plug should be located in an acces-
sible zone.
The plug must be equipped with a protec-
tion circuit.
If after installation the plug can not be
reached, a disconnecting device must be
envisaged.
Fixed installation:
The fixed installation can be carried out
by a qualified and authorized person only.
Envisage an omnipolar switch having a
contact opening of at least 3mm, including
an automatic circuit breaker.
The cable must be replaced by the manufac-
turer, the assistance centre or a qualified and
authorized person only, in order to avoid any
dangers.
Electrical data:
The technical data of the device are on the
distinctive label inside the device behind the
grease filters.
In case of repair, disconnect the electric
supply from the cooker hood.
Length of the feeding cable: 1,30m.
The hood complies with the EMC directives.
16
Fitting the extractor hood Final assembly
To the wall
60 cm wide extractor hood:
With 4 screws. Fig. 10.
90 cm wide extractor hood:
With 4 screws. Fig. 10.
1. Mark mounting boreholes.
Dimensions can be found in Fig. 10 or
use template.
2. Drill 6 mm dia. holes and insert wallplugs
flush with the wall.
3. Screw in the upper screws (on left and
right) until there is a gap of approx. 7mm
between the screw head and the wall.
4. Remove the filter grille
(see Instructions for use)
5. Attach the extractor hood.
6. If the cooker hood is not in perfect hori-
zontal level (fig. 11/1), adjust it by using
the adjusting screws (fig. 11/2).
7. Tighten the lower screw (with washer)
inside the extractor hood. Fig. 12.
To a wall-hanging cupboard
60 cm wide extractor hood:
With 4 screws. Fig. 13.
90 cm wide extractor hood:
With 4 screws. Fig. 13.
1. Dimensions for the mounting boreho-
les can be found in Fig. 13, or place a
template on the base of the wall-hanging
cupboard.
2. Mark the mounting holes and make pilot
holes with a bradawl. Fig. 13.
In exhaust-air mode (upwards) mark the
exhaust-air opening and saw out.
Fig. 13.
Consider the location of the connection
cable; if required, saw out the cupboard.
3. Remove the filter grille
(see Instructions for use).
4. Screw the extractor hood to the base of
the cupboard. Fig. 14.
Extractor hood
Selecting the operating mode Fig. 15:
Exhaust-air mode: Position 1
Circulating-air mode: Position 2
Connect to the power supply.
Insert the filter grille(see Instructions for
use).
Specifications
Weight in kg:
in accordance with DIN 44971
Width Exhaust air Circulating air
60 cm 8,2 8,7
90 cm 9,7 10,2
Illuminance in lux:
110 Lux (2 x 40 Watt)
Design changes with respect to technical deve-
lopment shall remain withheld.
LI3K9E Ed.07/15
BSH Ev Aletleri Sanayi ve Ticaret A.Ş.,
FSM Mah. Balkan Cad. 51, 34771 Ümraniye İstanbul, TURKEY,
www.bosch-home.com
9001230935
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68

Bosch DHU935HME/02 Operating instructions

Category
Cooker hoods
Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI