Broan Best EB15 Installation guide

Category
Cooker hoods
Type
Installation guide

This manual is also suitable for

ENGLISH.......................................2
FRANÇAIS...................................13
ESPAÑOL....................................24
For use with Best By Broan Exterior Blower model
EB6, EB9, EB12, or EB15.
Model KEX8087
In USA - BEST Hartford, Wisconsin
In CANADA - BEST Drummondville, QC, Canada
REGISTER YOUR PRODUCT ONLINE AT : www.BestRangeHoods.com/register
For additional Information visit www.BestRangeHoods.com
- 2 -
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions,
contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock service
panel to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accor-
dance with all applicable codes and standards, including fire-rated construction codes
and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equip-
ment manufacturer’s guidelines and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other
hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any separate solid-state speed control device.
8. To reduce the risk of fire, use only steel ductwork.
9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
A. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers
t
hat may ignite. Heat oils slowly on low or medium settings.
B. Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes
Suzette, Cherries Jubilee, Peppercorn Beef Flambe’).
C. Clean ventil
ating fans frequently. Grease should not be allowed to accumulate on fan or filter.
D. Use proper pan size. Always use cookware appropriate for the size of the surface element.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP
GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the
burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will
result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already know how to operate
it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
!
INTENDED FOR DOMESTIC COOKING ONLY
!
- 3 -
!
CAUTION
1. For indoor use only.
2. To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent
exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.
3. Take care when using cleaning agents or detergents.
4. Avoid using food products that produce flames under the Range Hood.
5. For general ventilating use only. Do not use to exhaust hazardous or explosive materi-
als and vapors.
6. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall
spray, construction dust, etc. off power unit.
7. Your hood motor has a thermal overload which will automatically shut off the motor if it
becomes overheated. The motor will restart when it cools down. If the motor continues
to shut off and restart, have the hood serviced.
8. For best capture of cooking impurities, the bottom of the hood should be a minimum of
24" and a maximum of 30" above the cooking surface. See page 9 for mounting restric-
tions.
9. Two installers are recommended because of the large size and weight of this hood.
10. This product is equipped with a thermostat which may start blower automatically. To
reduce the risk of injury and to prevent power from being switched on accidentally,
switch power off at service panel and lock or tag service panel.
11. Use with approved cord-connection kit only.
12. Please read specification label on product for further information and requirements.
For use with Best By Broan Exterior Blower model
EB6, EB9, EB12, or EB15.
- 4 -
OPERATION
Controls
Your hood is operated using the (5) push buttons located at eye-level, on the front
edge of the hood. It includes an on-off light switch, a filter cleaning alarm, ten-minute
run delay and blower speed settings.
Light Button, Filter Alarm, Alarm Reset:
Turns halogen lights on and off. Press once to turn the lights ON to low level.
Press a second time to turn the lights on to a brighter level. Press a third time
to turn the light off.
When blower is off, this switch remains lit after 30 hours of operation, indicating
a need to replace the charcoal filter.
After filters are cleaned or replaced, press this button for one-second to reset
the filter alarm.
Blower On-Off, Speed 1
Press once to turn the blower ON to its lowest running speed.
Quickly pressing the switch once delays blower shut off by ten-minutes.
Depress and hold switch down to turn blower off without delay.
Blower Speed 2
With blower running, press switch 2 to change blower speed to medium-low.
Quickly pressing the switch once delays blower shut off by ten-minutes.
To turn off without delay, depress and hold down the 0-1 switch.
Blower Speed 3
With blower running, press switch 3 to change blower speed to medium-high.
Quickly pressing the switch once delays blower shut off by ten-minutes.
To turn off without delay, depress and hold down the 0-1 switch.
Blower Speed 4
With blower running, press switch 4 to change blower speed to high.
Quickly pressing the switch once delays blower shut off by ten-minutes.
To turn off without delay, depress and hold down the 0-1 switch.
HEAT SENTRY™
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a
device that will turn on or speed up the blower if it senses excessive heat above
the cooking surface.
1) If blower is OFF, it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting, it turns blower up to HIGH speed.
When the temperature level drops to normal, the blower will return to its original
setting.
WARNING
The HEAT SENTRY thermostat can start the blower even if the hood is turned
OFF. When this occurs, it is impossible to turn the blower OFF with its switch.
If you must stop the blower, do it from the main electrical panel.
0 - 1 2 3 4
Light switch /
Filter Alarm &
Reset
Blower On-
Off / Speed
1
Blower
Speed 2
Blower
Speed 3
Blower
Speed 4
- 5 -
FUSE REPLACEMENT
IF LIGHTS FAIL TO OPERATE, DISCONNECT
THE POWER AT THE SERVICE ENTRANCE.
CHECK THE FUSE AND REPLACE IF
NECESSARY.
1. Remove the filters.
2. Locate the control board box and
transformer, positioned up inside the hood.
Fig. 2
3. Unfasten (4) screws from the control board
box and remove the cover. Fig. 2
4. Remove the fuse from the control board.
Fig. 2
5. Replace the fuse with the same size and
amperage (5x20mm, 4amp, 125volt).
6. Replace the control box cover and secure
with (4) screws.
7. Reconnect power at the service
entrance.
FIG. 2
FUSE
DECORATIVE
FLUE
CONTROL
BOARD BOX
HALOGEN BULBS
This range hood requires two halogen bulbs
(Type JC, 12Volt, 20Watt Max, G-4 Base).
ALWAYS SWITCH OFF THE ELECTRICAL
SUPPLY BEFORE CARRYING OUT ANY
OPERATIONS ON THE APPLIANCE.
To change bulbs:
1. Open the cover by prying from the proper
slots. - DO NOT ROTATE. CAUTION: BULB
MAY BE HOT! Fig. 1
2. Replace with a Type JC, 12Volt, 20Watt
Max, G-4 Base bulb. Do not touch
replacement bulb with bare hands!
FIG. 1
- 6 -
MAINTENANCE
Proper maintenance of the Range Hood will
assure proper performance of the unit.
Grease Filter
Grease filter should be cleaned when the light
switch flashes or remains lit when the blower
is off (i.e. 30 hours of operation). Use a warm
detergent solution to clean filters. Filters are
dishwasher safe. See page 12 for filter removal
and installation instructions.
Hood Cleaning
Stainless steel is one of the easiest materials to keep clean. Occasional care will
help preserve its fine appearance.
Cleaning tips:
Hot water with soap or detergent is all that is usually needed.
Follow all cleaning by rinsing with clear water. Wipe dry with a clean, soft cloth to
avoid water marks.
For discolorations or deposits that persist, use a non-scratching household
cleanser or stainless steel polishing powder with a little water and a soft cloth.
For stubborn cases, use a plastic scouring pad or soft bristle brush together with
cleanser and water. Rub lightly in direction of polishing lines or "grain" of the
stainless finish. Avoid using too much pressure which may mark the surface.
DO NOT allow deposits to remain for long periods of time.
DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere
to the surface causing rust.
DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to
remain in contact with stainless steel for extended periods. Many of these com-
pounds contain chemicals which may be harmful. Rinse with water after expo-
sure and wipe dry with a clean cloth.
Painted surfaces should be cleaned with warm water and mild detergent only.
GREASE
FILTER
- 7 -
PREPARE THE HOOD
Unpack hood and check contents.
You should receive:
1 - Hood
1 - Decorative Flue Assembly
1 - Discharge Collar
1 - Parts Bag (B080810482) containing:
1 - Mounting Bracket
1 - Flue Mounting Bracket
8 - Mounting Screws (4.8 x 38mm Pan Head)
4 - Mounting Screws (3.9 x 9.5mm Pan Head)
2 - Bracket Screws (3.9 x 5.7mm Flat Head)
8 - Drywall Anchors
1 - Installation Instructions
1 - Warranty Card
MOUNTING
BRACKET
DISCHARGE
COLLAR
FLUE MOUNTING
BRACKET
8 MOUNTING SCREWS
(4.8 x 38mm Pan Head)
8 DRYWALL
ANCHORS
4 MOUNTING
SCREWS (3.9 x 9.5mm
Pan Head)
DECORATIVE
FLUE
2 BRACKET SCREWS
(3.9 x 5.7mm Flat Head)
- 8 -
INSTALL THE DUCTWORK
NOTE: To reduce the risk of fire, use only metal ductwork.
1. Choose the location where the exterior blower will be mounted. See illustra-
tions below for mounting location suggestions and restrictions.
2. A straight, short duct run will allow the hood to perform most efficiently.
3. Long duct runs, elbows and transitions will reduce the performance of the
hood. Use as few of them as possible. Larger ducting may be required for best
performance with long duct runs.
4. After the exterior blower has been installed, connect round metal ductwork and
work back towards the hood location. Use duct tape to seal joints between
ductwork sections.
5. An 8” round to 10” round transition (Model 414) is required. For best air
performance, install the adapter as close to the range hood as possible.
EXTERIOR
BLOWER
10” ROUND
DUCT
HOOD
DECORATIVE
FLUE
EXTERIOR
BLOWER
8” TO 10”
ROUND
ADAPTER
8” ROUND
ELBOW
10”
ROUND
DUCT
8” ROUND
DUCT
OK
OK
CAUTION: MAY NOT
FIT UNDER EAVES
OF SINGLE STORY
HOMES
SUGGESTED MOUNTING LOCATIONS
24” TO 30” ABOVE
COOKING SURFACE
(See “INSTALL
MOUNTING BRACKET”
SECTION, page 9, for
mounting restrictions)
EXTERIOR BLOWER SELECTION
CAUTION: To reduce the risk of fire and electric shock, install this rangehood only
with EB6, EB9, EB12 or EB15 Exterior Blowers.
The exterior ventilator must be UL listed for Canadian and U.S. use, and evaluated
for use with solid state speed control, rated 120V, 60 Hz, 6.0 A max.
- 9 -
INSTALL MOUNTING
BRACKET
1. Construct wood wall framing that is flush
with interior surface of wall studs.
Make sure:
a) the framing is centered over
installation location.
b) the height of the framing will allow the
mounting bracket to be secured to the
framing within the dimensions shown.
2.
After wall surface is finished, secure mount-
ing bracket to framing using dimensions
shown.
Note: minimum hood distance above cook top must not be less than 24”. A maximum
of 30” above cook top is highly recommended for best capture of cooking impurities.
Distances over 30” are at the installer and users discretion; and if ceiling height and
flue length permit.
FRAMING BEHIND CROSS SUPPORT
DRYWALL
CEILING
HEIGHT
8 FEET
9 FEET
HOOD DISTANCE ABOVE 36” HIGH COOK TOP (SEE NOTE BELOW)
24”
25” 26” 27” 28” 29” 30”
MOUNTING BRACKET LOCATION ABOVE 36” HIGH COOK TOP
36-3/4”
37-3/4” 38-3/4” 39-3/4” 40-3/4” 41-3/4”
10 FEET WITH
FEXTK8087
37-3/4” 38-3/4” 39-3/4” 40-3/4” 41-3/4” 42-3/4”
36-3/4”
37-3/4” 38-3/4” 39-3/4” 40-3/4” 41-3/4” 42-3/4”
INSTALL FLUE MOUNTING
BRACKET
1. Assemble the flue mounting bracket,
adjusting outside width as shown. Fig.4
2. Carefully center the mounting bracket
directly over the range hood location.
3. Secure the bracket assembly to the ceiling
using (2) 4.8x38mm mounting screws
and drywall anchors. Make sure the
bracket is pushed into the corner, tight
against the wall and centered over the
hood.
FLUE MOUNTING
BRACKET
9 3/4”
FIG. 4
3.9x5.7mm FLAT
HEAD BRACKET
SCREWS
WOOD CROSS SUPPORT
BEHIND DRYWALL
- 10 -
PREPARE THE HOOD
Note: On stainless steel hoods, carefully
remove the plastic protective film from all
exterior surfaces of the hood and decorative
flues, prior to final installation.
1. Locate (2) tabs on top of the hood and inside
the round discharge opening. Fig. 5
2. Fold both tabs up 90 degrees. Fig. 5
3. Install the discharge collar inside the tabs
and secure with (2) 3.9 x 9.5mm screws.
Fig. 5
4. Attach an adequate length of 8” round steel
ducting to the range hood’s discharge collar.
Fig. 5
5. Duct tape all joints to make them secure
and air tight.
DISCHARGE
COLLAR
TABS
8” DUCT
FIG. 5
MOUNTING
SCREWS
(4.8x38)
RECTANGULAR
CUTOUT
MOUNTING
BRACKET
FIG.6
INSTALL THE HOOD
1. Install the hood into its mounted position.
2. Align the rectangular opening on the back
of the hood with the wall-mounting bracket.
Gently lower the hood until it securely
engages the bracket. Fig. 6
3. Level the hood and secure with (4) mounting
screws (4.8x38mm). Use drywall anchors
provided if wall studs or framing are not
available. Fig. 6
- 11 -
WIRING
CAUTION: All electrical wiring should be
done by a qualified person (s) in accordance
with all applicable codes and standards.
This range hood must be properly grounded.
Do not turn power on at service panel until
all wires have been connected.
Blower connection at hood:
1. Run 2-wire plus ground power cable from
the exterior blower to the hood’s wiring box
marked “motor connection”. Fig. 7
2. Remove the cover from the wiring box and
remove one knockout. Fig. 7
3. Feed 6” of cable through the knockout
opening and secure the cable to the wiring
box with an appropriate connector. Fig.7
4. Make electrical connections at the hood.
Connect white-to-white, red-to-black and
green-to-ground. Fig.7
5. Replace the wiring box cover and screws.
make sure wires are not pinched between
the cover and box.
Exterior blower connection:
1. Make electrical connections at the exterior
blower (see instructions provided with the
exterior blower).
Power connection at hood:
1. Run 120 VAC electrical power cable to the
hood wiring box marked “120VAC input”.
Fig. 8
2. Remove the cover from the wiring box and
remove one knockout. Fig. 8
3. Feed 6” of cable through the knockout
opening and secure the cable to the wiring
box with an appropriate connector. Fig. 8
4. Make electrical connections at the hood.
Connect white-to-white, black-to-black
and green-to-ground. Fig. 8
5. Replace the wiring box cover and screws.
Make sure wires are not pinched between
the cover and box.
BOX MARKED “120
VAC INPUT”
BLOWER CONNECTION AT HOOD
BOX MARKED
“MOTOR
CONNECTION”
Exterior blower
FIG. 7
FIG. 8
!
CONNECT:
WHITE-TO-WHITE,
RED-TO-BLACK,
GREEN-TO-GROUND.
POWER CONNECTION AT HOOD
CONNECT:
WHITE-TO-WHITE,
BLACK-TO-BLACK,
GREEN-TO-GROUND.
120 Volt 60Hz
LINE-IN
- 12 -
INSTALL THE FLUE
1. Carefully slide the upper flue down inside
the lower flue. Fig. 9
2. Lift and position the flue assembly into
the recessed area of the hood. Make sure
it is properly seated. Fig. 9
3. Raise the upper flue until its holes align
with holes in the flue mounting bracket
(located on ceiling). Fig. 9
4. Secure the flue with (2) mounting screws
(3.9x9.5mm). Fig. 9
3.9x9.5mm
MOUNTING SCREWS
FIG. 9
GREASE
FILTERS
FIG. 10
INSTALL FILTER(S)
1. To remove the GREASE filter(s), grip the
latch tab and pull it down. This will disen-
gage the filter from the hood. Tilt the filter
downward and remove. Fig. 10
2. To install the GREASE filter(s), align rear
filter tabs with slots in the hood. Pull latch
tab down, push filter into position and
release. Make sure the filter is securely
engaged after assembly.
WARRANTY
ONE YEAR LIMITED WARRANTY FOR BEST PRODUCTS
Broan-NuTone LLC (Broan-NuTone) warrants to the original consumer purchaser of Best products that such products will be
free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR
MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is
found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDES-
CENT BULBS, FUSE, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This
warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse,
negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary
to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do
not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE'S OPTION, SHALL BE THE
PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE
LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH
PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty
supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address stated below or telephone number stated
below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At
the time of requesting warranty service, you must present evidence of the original purchase date.
In USA - Best®, 926 W. State Street, Hartford, WI 53027 (800-558-1711)
In Canada - Best®, 550 Lemire Blvd., Drummondville, QC J2C 7W9 (866-737-7770)
www.BestRangeHoods.com
- 35 -
SERVICE PARTS
MODEL KEX8087 HS - Parts for stainless steel models shown. For service parts
for black, white, polished brass, or brushed copper models, call Broan Customer
Service.
KEY NO. PART NO. DESCRIPTION
7 BE3345107 Support
9 B08087169 Grease Filter
16 BE3345329 Electrical Box Support
19 B03295005 Terminal Box
26 B02300891 Halogen Lamp Bulb
37 B02300787 Heat Sentry
38 B03292357 Control Board Box
39 B03294033 Control Board Cover
57 BE3300527 Damper Flap
62 B08091602 Blower Mounting Cover
86 B08088242 Discharge collar + Damper Flap
115 BE3334250 Wiring Box
116 BE3334252 Wiring Box Cover
118 B003100591 Decorative Flue Bottom
119 BE3346837 Decorative FlueTop
120 B08091367 Flue Mounting Bracket
144 B03292287 Wire Clamp
166 B08086644 Control Board
208 B02300739 Transformer
223 B03293068 Switch Button
228 B08086249 Controls Board
230 B03293069 Switch Board Box Cover
234 B03293009 Control Board Box
235 BE3345106 Switch Mounting Bracket
332 BE3345328 Cover
474 B02300798 Halogen Lamp Housing
477 B03294776 Terminal Cover
* B06107786 Switch Assembly (Includes Key Nos. 223, 228,
230, 234, 235)
998 B080810482 Hardware Package
* Not shown assembled.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40

Broan Best EB15 Installation guide

Category
Cooker hoods
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI