Viking CV41C4CSB Installation guide

Type
Installation guide
F20293B EN (040308J)
Viking Range Corporation
111 Front Street
Greenwood, Mississippi 38930 USA
(662) 455-1200
For product information,
call 1-888-VIKING1 (845-4641)
or visit the Viking Web site at
vikingrange.com
Viking Installation Guide
C4
Outdoor Cooker Cart Assembly
3
5. With a minimum of two people, place the cooker on the cooker shelf located in the cart. Also, make sure the
cooker is placed on the mounting bracket located on the cart directly under the hinge. The hinge and the inside
damper vent should be used for hand holds. (See Figure 3).
6. Re-install dome, hinge nuts and
washers. Remove shipping screws
from each side of hinge. Replace
inside parts
support bracket
screws
Shelf adjustment screw
Front View
Supports
Leveling the Side Shelves
To level the side shelves, lift the shelf
so that the shelf adjustment screw is
visible between the two supports on
the shelf brackets. Turn the screw
with the included 3/32” (.2 cm) allen
wrench counter clockwise to raise the
shelf and clockwise to lower the
shelf. (See Figure 4)
Figure 4
Damper vent
Cooker shelf
Figure 3
Mounting Bracket
(located behind
cooker on cart
directly under hinge)
Hinge
IMPORTANT: PLEASE READ AND FOLLOW
1. Before beginning, please read these instructions completely and carefully.
2. Do not remove permanently affixed labels, warnings, or plates from product.
To mount the cooker to the cart:
Always wear gloves when installing the cooker. Although the cooker and cart is deburred prior to shipment, some
edges may still be sharp enough to cause injury during handling.
1. Remove the stainless steel side burner cover, side burner grates, burner bowls and grate support. (41” W. models
only)
2. Remove the top from the cart. (See Figure 1)
CAUTION: Keep hands and fingers away fro spring area.
3. Install two (2) shipping screws, (one set on each side). (See Figure 2) Remove the two (2) top nuts and washers on
each side of the hinge mount.
4. Remove all inside parts.
Figure 1
Stainless cover
Grates
Burner bowls
Grate support
Cart top
Remove the (2) top nuts and
washers on each side of hinge
Install (2) shipping screws
(one on each side)
CAUTION
Keep hands and fingers out of
spring area. Lift from bottom
or inside front of hinge.
Figure 2
2
5
CART DIMENSIONS
30” W. Cart - Front
30” W. Cart - Side
36-1/2”
(92.7 cm)
37-5/8”
(95.6 cm)
61-3/4” (156.9 cm)
37-7/8” (96.2 cm)
29-3/8” (77.6 cm)
37-5/8”
(95.6 cm)
23-7/8” (60.6 cm)
31-5/8” (79.7 cm)
33-3/8” (84.8 cm)
53-1/8” (134.5 cm)
Cart Door Adjustment (41” W. Model only)
The cart door comes adjusted from the factory. Depending on how level the surface the cart is being placed on, the
door may need to be adjusted after the grill is assembled on the cart.
There are two adjustment screws on the hinge receiver. (See Figure 5)
1) The front screw is used to center the door in the opening. Turning the front screws in or out will center the door in
the frame.
2) The back screw is used to align the front of the door with the cart frame and secure the door to the cart. Slightly
loosen the screw and slide the door in or out. Retighten the screw to secure the door.
Door Hinge
(2 places)
Back
Screw
Front
Screw
4
Figure 5
BASIC SPECIFICATIONS
DESCRIPTION QSC200 QSC300 QSC412
Overall Width 23” (58.4 cm) 61-3/4” (156.9 cm) 73-3/8” (186.4 cm)
Overall Height 21-3/4” (55.2 cm) 37-5/8” (95.6 cm) 37-1/2” (95.3 cm)
Overall Depth 21” (53.3 cm) To end of landing ledge 31-5/8” (79.7 cm)
To end of knobs 33-3/8” (84.8 cm)
Gas Requirements N/A N/A Natural: Standard residential 1/2”
(1.3 cm) ID gas service line
LP/Propane: Equipped with high
capacity hose/regulator
assembly for connection to
standard 5 gal, 20 lb.
LP/Propane gas cylinder
with Type 1, QCC-1
connection or standard
residential 1/2” (1.3 cm) ID
gas service line
Electrical Requirements N/A N/A 9 volt DC battery for electronic ignition
Surface Burner Rating N/A N/A 15,000 BTU Nat./13,500 LP/Propane
(4.4 kW Nat./4.0 kW LP/Propane)
Approx. Shipping Weight 50 lbs. (22.5 kg) 170 lbs. (76.5 kg.) 275 lbs. (123.8 kg)
41” W. Cart - Side
41” W. Cart - Front
50-1/2” (128.3 cm)
41-1/4” (104.8 cm)
73-3/8” (186.4 cm)
36-1/2”
(92.7 cm)
37-1/2”
(95.3 cm)
24” (104.8 cm)
31-5/8” (79.7 cm)
33-3/8” (84.8 cm)
44-5/8” (113.5 cm)
53-1/8” (134.9 cm)
2-1/4”
(5.7 cm)
76
30” W. Cart - Top
41” W. Cart - Top
29-7/16” (74.8 cm)
61-3/4” (156.7 cm)
73-3/8” (186.4 cm)
41-3/16” (104.6 cm)
9
NATURAL FIXED PIPING CONNECTION
Connection: Standard Residential 1/2” ID gas service line - 1/2 NPT male with 1/2 flare adapter.
Operating Pressure: 4.0 W.C.P. Nat.
Supply Pressure: 6 to 14 W.C.P. Nat. If in excess of 14” W.C.P., a step-down regulator is required.
Check with your local gas utility company or with local codes for instructions on installing gas supply lines. Be sure to check on
type and size of run and how deep to bury the lines. If the gas line is too small, the grill will not function properly.
To connect the supplied regulator assembly to the incoming flexible gas line, attach with a 1/2 (1.3 cm) female flare adaptor
to the 1/2 (1.3 cm) male flare adaptor on the regulator assembly. Ensure that the regulator arrow points in the direction of the
gas flow towards the unit and away from the supply. Attach the regulator assembly to the grill unit by pulling back the female
coupler sleeve towards the regulator. Insert the coupler into the male coupler fitting on the grill until the sleeve snaps forward
securing the connection. DO NOT forget to place the installer supplied gas valve in an accessible location.
NOTE: If using a Viking GSH12 flexible hose, remove the 3/8” flare adapter and attach hose to the the 1/2 (1.3 cm) male
flare on the regulator assembly.
Installer supplied
shut-off valve must
be easily accessible
1/2” female
flare
1/2” Male fitting
Installer supplied flexible gas line with 1/2”
female flare adaptor or Viking GSH12
Regulator Assembly
Female
coupler sleeve
Regulator
1/2” male
flare adaptor
GAS CONNECTION
Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the rating plate agrees with
that of the supply. Never connect an unregulated gas line to the appliance. An installer supplied gas shut-off valve must
be installed in an easily accessible location. All installer supplied parts must conform to local codes, or in the absence of
local codes, with the National electrical Code, ANSI/NFPA 70 and the National Fuel Code, ANSI Z223.1. In Canada:
Installation must be in accordance with the current CAN/CGA-B149.1, Natural Gas Installation Code or CAN/CGA-
B149.2, Propane Installation Code and/or local codes. All pipe sealants must be an approved type and resistant to the
actions of LP gas. Never use pipe sealant on flare fittings. All gas connections should be made by a competent technician
and in accordance with local codes and or ordinances. In the absence of codes, the installation must comply with the
National Fuel Gas Code ANSI Z223.1.
The side burners and the individual shut-off valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 kPa). The unit must be isolated from the gas
supply piping system by closing its individual manual shut-off valve during any pressure testing of that system at test
pressures equal to or less than 1/2 psi (3.5 kPa).
8
INSTALLATION OF SIDE BURNERS
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. Open lid.
4. If odor continues, immediately call your gas supplier or your
fire department.
1. Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
2. Any LP cylinder not connected for use shall not be stored
in the vicinity of this or any other appliance.
If not installed, operated and maintained in
accordance with the manufacturers instructions, this
product could expose you to substances in fuel or
fuel combustion which can cause death or serious
illness and which are known to cause cancer, birth
defects or other reproductive harm.
For example, benzene is a chemical which is
part of the gas supplied to the cooking
product. It is consumed in the flame during
combustion. However, exposure to a small
amount of benzene is possible if a gas leak
occurs. Formaldehyde and soot are by-
products of incomplete combustion. Properly
adjusted burners with a bluish rather than
yellow flame minimize incomplete combustion.
FOR YOUR SAFETY
WARNING
FOR YOUR SAFETY
GENERAL INFORMATION
1. WARNING: This side burner cart is not intended to be installed in or on recreational vehicles and/or boats.
2. Keep grill area clear and free from combustible materials, gasoline, and other flammable vapors.
3. When the side burners are not in use, the gas supply must be turned off at the LP gas supply cylinder.
4. The pressure regulator and hose assembly supplied with the outdoor grill must be used. Replacement pressure
regulators and hose assemblies must be those specified by the manufacturer.
5. Finding a leak is not a “do-it-yourself” procedure. Some leaks can only be found with the burner control in the on
position and this must be done by a qualified technician.
6. The LP supply cylinder to be used must be constructed and marked in accordance with the specifications for LP-gas
cylinders of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339,
Cylinders, Spheres, and Tubes for the Transportation of Dangerous Goods.
7. Gas Manifold Pressure - Natural gas - 4.0” W.C.P. LP/Propane - 10.0” W.C.P.
8. If the following instructions are not followed exactly, a fire causing death or serious injury may occur:
-Do not store a spare LP gas cylinder under or near this appliance.
-Never fill the cylinder beyond 80 percent full.
GAS CONVERSION
To convert the side burners from natural to LP/Propane or LP/Propane to natural, you MUST use the
conversion kit supplied by the manufacturer.
WARNING: Conversions should only be done by an authorized service technician.
PROXIMITY TO CABINETS
The cart can be installed directly adjacent to side cabinets. There is 0” side clearance to non-combustible and combustible
surfaces. A minimum of 6 (15.2 cm) from the back of the unit is required for the purpose of allowing the cooker dome to
open fully.
11
LP/PROPANE TANK CONNECTION
Side Burners orificed for use with LP/Propane gas come equipped with a high capacity hose/regulator assembly for
connection to a standard 20 lb. LP/Propane cylinder equipped with a Type 1, QCC-1 connector. (See LP/Propane tank
requirements on page 6).
Connection: 1/2” (1.3 cm) NPT male with a 1/2” (1.3) flare adapter
Operating Pressure: 10.0” W.C.P.
To connect to LP/Propane regulator/hose assembly:
Although the flow of gas is stopped when the quick disconnect system is disconnected as part of its safety feature,
you should always turn the LP/Propane tank main valve “OFF” after each use and during transport of the tank or
unit. First connect the regulator to the unit by screwing the 1/2” flare coupling onto the 1/2” flare adapter.
Connect to the tank valve by screwing the Type 1, QCC-1 connector to the LP/Propane tank. Open the tank valve
and check the connection between the regulator and the Type 1, QCC-1 fitting for leaks with a soapy water
solution. If bubbles appear, tighten the connection. Repeat until all leaks have been stopped.ALWAYS CHECK
FOR LEAKS AFTER EVERY LP/PROPANE TANK CHANGE
Any joint sealant used must be an approved type and be resistive to the actions of LP/Propane gas
1/2” flare
adapter
Type 1, QCC-1
connector
Tank
1/2 flare coupling
LP/PROPANE TANK REQUIREMENTS
A dented or rusty LP/Propane tank may be hazardous and should be checked by your tank supplier. Never use a cylinder
with a damaged valve. All tanks should be equipped with an OPD (overfilling protection device). This is a DOT
requirement for all tanks purchased after October 1, 1998 and will ensure that the tank is not overfilled. The LP/Propane
tank should be a standard 5-gal, 20 lb. gas cylinder tank approximately 12” in diameter and 18” high which must be
constructed and marked in accordance with the Specifications for LP/Propane Gas Cylinders of the U.S. Department of
Transportation (D.O.T.) or the National Standard of Canada, CAN/CSA-B339, Cylinders, Spheres and Tubes for
Transportation of Dangerous Goods; and Commission. The cylinder connection device must be compatible with the Type
1, QCC-1 connector on the outdoor cooking appliance. The cylinder must be provided with a shut-off valve terminating
in an LP/Propane gas supply cylinder valve outlet specified, as applicable, for a 5LP-A connection. The cylinder supply
system must be arranged for vapor withdrawal and provided with a listed overfilling prevention device. If the appliance
is stored indoors the cylinder must be disconnected and removed from the appliance. Cylinders must be stored outdoors
in a well-vented area out of the reach of children.
3/8” female
flare adaptor
Regulator
3/8” male
flare adaptor
LP/PROPANE FIXED PIPING CONNECTION
Connection: Standard Residential 1/2” ID gas service line - 1/2 NPT male with 3/8 flare adapter.
Operating Pressure: 10.0 W.C.P. Nat.
Supply Pressure: 11 to 14 W.C.P. Nat. If in excess of 14” W.C.P., a step-down regulator is required.
Check with your local gas utility company or with local codes for instructions on installing gas supply lines. Be sure to check on
type and size of run and how deep to bury the lines. If the gas line is too small, the grill will not function properly.
To connect the supplied regulator assembly to the incoming flexible gas line, attach with a 3/8 female flare adaptor to the
3/8 male flare adaptor to the regulator assembly. Ensure that the regulator arrow points in the direction of the gas flow
towards the unit and away from the supply. Attach the regulator assembly to the grill unit with the 3/8” female flare adapter on
the regulator assembly to the 3/8 male flare adaptor on the grill.
DO NOT forget to place the installer supplied gas valve in an accessible location.
Installer supplied
shut-off valve must
be easily accessible
1/2” female
flare
1/2” Male fitting
Installer supplied flexible
gas line with 1/2” female
flare adaptor or Viking
GSH12
10
Regulator Assembly
Air Shutters
Orifice
1½
(3.8 cm)
3/8”
(.95 cm)
FLAME HEIGHT
BURNER ADJUSTMENT
Each burner is tested and adjusted at the factory prior to shipment; however, variations in the local gas supply may make
it necessary to adjust the burners. The flames of the burners should be visually checked and compared with flame height
drawing below.
Flames should be blue and stable with no yellow tips, excessive noise or lifting. If any of these conditions exist,
check if the air shutter or burner ports are blocked by dirt, debris, spider webs, etc. With a proper flame height, adjust
the air shutter to obtain a blue flame with no yellow tipping that sits on the burner at the burner ports. The air shutter is
locked in place by a set screw which must be loosened prior to lighting the burner for adjustments.
To access the air shutter on the side burners, remove the grates, burner bowls, and grate support. With a screw
driver, loosen the lock-screw on the face of the air shutter. Light the burner and adjust according to the directions below.
1. If the flame is yellow, turn the air shutter counter clockwise to allow more air to the burner.
2. If the flame is noisy and lifting away from the burner, turn the air shutter clockwise to reduce the amount of
air to the burner.
Once adjusted, turn the burner off, tighten the set screw on the air shutter, replace the grate support, burner bowls, and
grates. To ensure proper installation of the side burners, slide opening in air shutters over the orifice located in the front
of the unit.
12
LEAK TESTING
Although all gas connections on the grill are leak tested at the factory prior to shipment, a complete gas tightness check
must be performed at the installation due to possible mishandling in shipment or excessive pressure unknowingly being
applied to the unit. Periodically check the whole system for leaks, or immediately check if the smell of gas is detected.
1. Do not smoke while leak testing. Extinguish all flames.
2. Never leak test with an open flame.
3. Make a soap solution of one part liquid detergent and one part water. You will need a spray bottle, brush or towel to
apply the solution to the fittings. For LP/Propane units, check with a full cylinder.
4. Check that all control knobs are in the “OFF” position.
5. Turn cylinder valve knob counter clockwise one turn to open.
6. Blowing bubbles in the soap solution indicates that a leak is present.
7. Stop a leak by tightening the loose joint or by replacing the faulty part with a replacement part recommended by the
manufacturer. Do not attempt to repair the cylinder valve if it should become damaged. The cylinder must be
replaced.
8. If you are unable to stop a leak, shut off the gas supply at the cylinder valve. Remove the cylinder from the grill. Call
an authorized gas appliance service technician or LP/Propane gas dealer. Do not use the grill until the leak is
corrected.
9. After checking for leaks, push in and turn any control knob to release the pressure in the hose and manifold. Turn off
the control knob.
CAUTION
Before placing into operation, always check for gas leaks with a soapy
water solution. DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS!
Leak Test Points