Cisco Catalyst 3750V2-48TS Switch User manual

Type
User manual
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
Catalyst 3750, 3560, 3550, 2975, 2970,
and 2960 Switch System Message Guide
Cisco IOS Release 12.2(46)SE and Release 12.2(46)EX
November 2008
Text Part Number: OL-8551-04
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL
STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT
WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT
SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE
OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.
The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB’s public
domain version of the UNIX operating system. All rights reserved. Copyright © 1981, Regents of the University of California.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED “AS IS” WITH
ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR
IMPLIED, INCLUDING, WITHOUT
LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF
DEALING, USAGE, OR TRADE PRACTICE.
IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING,
WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO
OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
CCDE, CCENT, Cisco Eos, Cisco Lumin, Cisco Nexus, Cisco StadiumVision, Cisco TelePresence, Cisco WebEx, the Cisco logo, DCE, and Welcome to the Human Network
are trademarks; Changing the Way We Work, Live, Play, and Learn and Cisco Store are service marks; and Access Registrar, Aironet, AsyncOS, Bringing the Meeting To
You, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, CCVP, Cisco, the Cisco
Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems,
Cisco
Systems Capital, the Cisco Systems logo, Cisco Unity, Collaboration Without Limitation, EtherFast, EtherSwitch, Event Center, Fast Step, Follow Me Browsing,
FormShare, GigaDrive, HomeLink, Internet Quotient, IOS, iPhone, iQuick Study, IronPort, the IronPort
logo, LightStream, Linksys, MediaTone, MeetingPlace,
MeetingPlace Chime Sound, MGX, Networkers, Networking Academy, Network Registrar, PCNow, PIX, PowerPanels, ProConnect, ScriptShare, SenderBase, SMARTnet,
Spectrum Expert, StackWise, The Fastest Way to Increase Your Internet Quotient, TransPath, WebEx, and the WebEx
logo are registered trademarks of Cisco Systems, Inc.
and/or its affiliates in the United States and certain other countries.
All other trademarks mentioned in this document or website are the property of their respective owners. The use of the word partner does not imply a partnership relationship
between Cisco and any other company. (0809R)
Any Internet Protocol (IP) addresses used in this document are not intended to be actual addresses. Any examples, command display output, and figures included in the
document are shown for illustrative purposes only. Any use of actual IP addresses in illustrative content is unintentional and coincidental.
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
© 2007–2008 Cisco Systems, Inc. All rights reserved.
iii
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
CONTENTS
Preface vii
Audience i-vii
Purpose i-vii
Conventions i-vii
Related Publications i-viii
Obtaining Documentation, Obtaining Support, and Security Guidelines i-x
CHAPTER
2 System Message Overview 2-1
How to Read System Messages 2-1
Error Message Traceback Reports 2-7
Output Interpreter 2-7
Bug Toolkit 2-7
Contacting TAC 2-7
CHAPTER
3 Message and Recovery Procedures 3-1
ACLMGR Messages 3-3
AUTOQOS Messages 3-8
BACKUP_INTERFACE Messages 3-8
BADTRANSCEIVER Messages 3-9
BSPATCH Messages 3-9
CFGMGR Messages 3-10
CMP Messages 3-13
DHCP_SNOOPING Messages 3-14
DHCP_SNOOPING_CAT3550 Messages 3-17
DOT1Q_TUNNELLING Messages 3-18
DOT1X Messages 3-18
DOT1X_SWITCH Messages 3-19
DTP Messages 3-23
DWL Messages 3-24
EC Messages 3-25
ENVIRONMENT Messages 3-29
ETHCNTR Messages 3-30
Contents
iv
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
EXPRESS_SETUP Messages 3-34
FM Messages 3-35
FRNTEND_CTRLR Messages 3-44
GBIC Messages 3-45
GBIC_SECURITY Messages 3-48
GBIC_SECURITY_CRYPT Messages 3-51
GBIC_SECURITY_UNIQUE Messages 3-52
GIGASTACK Messages 3-53
HARDWARE Messages 3-54
HLFM Messages 3-56
HPSECURE Messages 3-57
IDBMAN Messages 3-58
IGMP_QUERIER Messages 3-61
ILPOWER Messages 3-62
IMAGEMGR Messages 3-69
IP_DEVICE_TRACKING_HA Messages 3-70
L2TM Messages 3-71
L3TCAM Messages 3-71
MAC_LIMIT Messages 3-72
MAC_MOVE Messages 3-73
NETWORK_PORT_SATELLITE Messages 3-73
PAGP_DUAL_ACTIVE Messages 3-74
PBR Messages 3-75
PHY Messages 3-77
PIMSN Messages 3-79
PLATFORM Messages 3-80
PLATFORM_FBM Messages 3-81
PLATFORM_HCEF Messages 3-82
PLATFORM_HPLM Messages 3-83
PLATFORM _IPC Messages 3-84
PLATFORM_IPv6 Message 3-85
PLATFORM_PBR Messages 3-86
PLATFORM_PM Messages 3-88
PLATFORM_RPC Messages 3-89
PLATFORM_SPAN Messages 3-91
Contents
v
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
PLATFORM_UCAST Messages 3-92
PLATFORM_VLAN Messages 3-95
PLATFORM_WCCP Messages 3-96
PM Messages 3-97
PORT_SECURITY Messages 3-105
QATM Messages 3-107
QM Messages 3-108
QOSMGR Messages 3-111
RMON Messages 3-117
SDM Messages 3-118
SPAN Messages 3-118
SPANTREE Messages 3-119
SPANTREE_FAST Messages 3-127
SPANTREE_VLAN_SW Messages 3-127
STACKMGR Messages 3-127
STORM_CONTROL Messages 3-130
SUPERVISOR Messages 3-131
SUPQ Messages 3-131
SW_DAI Messages 3-134
SW_MACAUTH Messages 3-137
SW_MATM Messages 3-138
SW_VLAN Messages 3-138
SWITCH_QOS_TB Messages 3-145
TCAMMGR Messages 3-146
UDLD Messages 3-148
UFAST_MCAST_SW Messages 3-150
VQPCLIENT Messages 3-150
WCCP Messages 3-152
WRLSCNTR Messages 3-152
I
NDEX
Contents
vi
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
vii
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
Preface
Audience
This guide is for the networking professional managing the Catalyst 3750, 3560, 3550, 2975, 2970, and
2960 switch or switch stack, hereafter referred to as the switch. Before using this guide, you should have
experience working with the Cisco IOS software and the switch software features.
Purpose
This guide describes only the Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 switch-specific system
messages that you might encounter. For a complete list of Cisco IOS system error messages, see the
Cisco IOS Software System Error Messages, Cisco IOS Release 12.2.
This guide does not describe how to install your switch or how to configure software features on your
switch. It also does not provide detailed information about commands that have been created or changed
for use by the switch. For hardware installation information, see the hardware installation guide that
shipped with your switch. For software information, see the software configuration guide and the
command reference for this release.
For documentation updates, see the release notes for this release.
Conventions
This publication uses these conventions to convey instructions and information:
Command descriptions use these conventions:
Commands and keywords are in boldface text.
Arguments for which you supply values are in italic.
Square brackets ([ ]) mean optional elements.
Braces ({ }) group required choices, and vertical bars ( | ) separate the alternative elements.
Braces and vertical bars within square brackets ([{ | }]) mean a required choice within an optional
element.
viii
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
Preface
Related Publications
Interactive examples use these conventions:
Terminal sessions and system displays are in screen font.
Information you enter is in boldface screen font.
Nonprinting characters, such as passwords or tabs, are in angle brackets (< >).
Notes use this convention and symbol:
Note Means reader take note. Notes contain helpful suggestions or references to materials not in this manual.
Related Publications
These documents provide complete information about the switch and are available from this Cisco.com
site:
Catalyst 3750 switch
http://www.cisco.com/en/US/products/hw/switches/ps5023/tsd_products_support_series_home.html
Catalyst 3560 switch
http://www.cisco.com/en/US/products/hw/switches/ps5528/tsd_products_support_series_home.html
Catalyst 3550 switch
http://www.cisco.com/en/US/products/hw/switches/ps646/tsd_products_support_series_home.html
Catalyst 2975 switch
http://www.cisco.com/en/US/products/ps10081/tsd_products_support_series_home.html
Catalyst 2970 switch
http://www.cisco.com/en/US/products/hw/switches/ps5206/tsd_products_support_series_home.html
Catalyst 2960 switch
http://www.cisco.com/en/US/products/ps6406/tsd_products_support_series_home.html
Note Before installing, configuring, or upgrading the switch, see these documents:
For initial configuration information, see the “Using Express Setup” chapter in the getting started
guide or the “Configuring the Switch with the CLI-Based Setup Program” appendix in the hardware
installation guide.
For device manager requirements, see the “System Requirements” section in the release notes (not
orderable but available on Cisco.com).
For Network Assistant requirements, see the Getting Started with Cisco Network Assistant (not
orderable but available on Cisco.com).
For cluster requirements, see the Release Notes for Cisco Network Assistant (not orderable but
available on Cisco.com).
For upgrade information, see the “Downloading Software” section in the release notes.
ix
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
Preface
Related Publications
See these documents for other information about the switch:
Release Notes for the Catalyst 3750, 3560, 3550, 2970, and 2960 Switches
Catalyst 3750, 3560, 3550, 2970, and 2960 Switch System Message Guide
Catalyst 3750 Switch Software Configuration Guide
Catalyst 3750 Switch Command Reference
Catalyst 3750 Switch Hardware Installation Guide
Catalyst 3750 Switch Getting Started Guide
Regulatory Compliance and Safety Information for the Catalyst 3750 Switch
Catalyst 3560 Switch Software Configuration Guide
Catalyst 3560 Switch Command Reference
Catalyst 3560 Switch Hardware Installation Guide
Catalyst 3560 Switch Getting Started Guide
Regulatory Compliance and Safety Information for the Catalyst 3560 Switch
Catalyst 3550 Multilayer Switch Software Configuration Guide
Catalyst 3550 Multilayer Switch Command Reference
Catalyst 3550 Multilayer Switch Hardware Installation Guide
Catalyst 3550 Multilayer Switch Getting Started Guide
Regulatory Compliance and Safety Information for the Catalyst 3550 Multilayer Switch
Catalyst 2975 Switch Software Configuration Guide
Catalyst 2975 Switch Command Reference
Catalyst 2975 Switch Hardware Installation Guide
Catalyst 2975 Switch Getting Started Guide
Regulatory Compliance and Safety Information for the Catalyst 2975 Switch
Release Notes for the Catalyst 2975 Switches
Catalyst 2970 Switch Software Configuration Guide
Catalyst 2970 Switch Command Reference
Catalyst 2970 Switch Hardware Installation Guide
Catalyst 2970 Switch Getting Started Guide
Regulatory Compliance and Safety Information for the Catalyst 2970 Switch
Catalyst 2960 Switch Software Configuration Guide
Catalyst 2960 Switch Command Reference
Catalyst 2960 Switch Hardware Installation Guide
Catalyst 2960 Switch Getting Started Guide
Regulatory Compliance and Safety Information for the Catalyst 2960 Switch
Device manager online help (available on the switch)
Getting Started with Cisco Network Assistant
Release Notes for Cisco Network Assistant
Cisco Small Form-Factor Pluggable Modules Installation Notes
x
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
Preface
Obtaining Documentation, Obtaining Support, and Security Guidelines
Cisco CWDM GBIC and CWDM SFP Installation Note
Cisco RPS 300 Redundant Power System Hardware Installation Guide
Cisco RPS 675 Redundant Power System Hardware Installation Guide
For information about the Network Admission Control (NAC) features, see the Network Admission
Control Software Configuration Guide (Not orderable but available on Cisco.com)
These compatibility matrix documents are available from this Cisco.com site:
http://www.cisco.com/en/US/products/hw/modules/ps5455/products_device_support_tables_list.html
Cisco Gigabit Ethernet Transceiver Modules Compatibility Matrix
Cisco 100-Megabit Ethernet SFP Modules Compatibility Matrix
Cisco Small Form-Factor Pluggable Modules Compatibility Matrix
Compatibility Matrix for 1000BASE-T Small Form-Factor Pluggable Modules
Obtaining Documentation, Obtaining Support, and Security
Guidelines
For information on obtaining documentation, obtaining support, providing documentation feedback,
security guidelines, and also recommended aliases and general Cisco
documents, see the monthly
What’s
New in Cisco Product Documentation, which also lists all new and revised Cisco technical
documentation, at:
http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html
CHAPTER
2-1
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
2
System Message Overview
This guide describes the Catalyst 3750, 3560, 3550, 2975, 2970, and 2960-specific system messages.
During operation, the system software sends these messages to the console (and, optionally, to a logging
server on another system). Not all system messages indicate problems with your system. Some messages
are purely informational, whereas others can help diagnose problems with communications lines,
internal hardware, or the system software. This guide also includes error messages that appear when the
system fails.
For information about system messages that are not Catalyst 3750, 3560, 3550, 2975, 2970, or 2960
platform-specific, see the Cisco IOS Software System Messages for Cisco IOS Release 12.2S.
This chapter contains these sections:
How to Read System Messages, page 2-1
Error Message Traceback Reports, page 2-7
How to Read System Messages
System log messages can contain up to 80 characters and a percent sign (%), which follows the optional
sequence number or time stamp information, if configured. Messages are displayed in this format:
seq no:timestamp: %facility-severity-MNEMONIC:description (hostname-n) (only Catalyst 3750 and
2975 switches)
seq no:timestamp: %facility-severity-MNEMONIC:description (switches other than Catalyst 3750 and
2975 switches)
By default, a switch sends the output from system messages to a logging process. In a switch stack, stack
members append their hostnames to the output from system messages and redirect the output to the
logging process on the stack master.
Each system message begins with a percent sign (%) and is structured as follows:
%FACILITY-SEVERITY-MNEMONIC: Message-text
FACILITY is a code consisting of two or more uppercase letters that show the facility to which the
message refers. A facility can be a hardware device, a protocol, or a module of the system software.
Table 2-1 lists Catalyst 3750, 3560, 3550, 2975, 2970, and 2960-specific facility codes. These
messages are described in Chapter 3, “Message and Recovery Procedures, in alphabetical order by
facility code, with the most severe (lowest number) errors described first.
2-2
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
Chapter 2 System Message Overview
How to Read System Messages
Ta b l e 2-1 Facility Codes
Facility Code Description Location
ACLMGR ACL manager ACLMGR Messages” section on page 3-3
AUTOQOS Automatic quality of service
(auto-QoS) (only Catalyst 3550
switches)
AUTOQOS Messages” section on page 3-8
BACKUP_INTERFACE Flex Links “BACKUP_INTERFACE Messages” section on
page 3-8
BADTRANSCEIVER Defective transceiver messages (only
3750 and 2975 switches)
“BADTRANSCEIVER Messages” section on
page 3-9
BSPATCH Boot loader patch “BSPATCH Messages” section on page 3-9
CFGMGR Configuration manager (only Catalyst
3750 and 2975 switches)
“CFGMGR Messages” section on page 3-10
CMP Cluster Membership Protocol “CMP Messages” section on page 3-13
DHCP_SNOOPING DHCP snooping “DHCP_SNOOPING Messages” section on
page 3-14
DHCP_SNOOPING_CAT3550 DHCP snooping (only Catalyst 3550
switches)
“DHCP_SNOOPING_CAT3550 Messages”
section on page 3-17
DOT1Q_TUNNELLING IEEE 802.1Q tunneling (only
Catalyst 3550 switches)
“DOT1Q_TUNNELLING Messages” section on
page 3-18
DOT1X IEEE 802.1x “DOT1X Messages” section on page 3-18
DOT1X_SWITCH IEEE 802.1x for switches “DOT1X_SWITCH Messages” section on
page 3-19
DTP Dynamic Trunking Protocol “DTP Messages” section on page 3-23
DWL Down-when-looped “DWL Messages” section on page 3-24
EC EtherChannel “EC Messages” section on page 3-25
ENVIRONMENT Environment (only Catalyst 3550
switches)
“ENVIRONMENT Messages” section on
page 3-29
ETHCNTR Ethernet Controller “ETHCNTR Messages” section on page 3-30
EXPRESS_SETUP Express Setup “EXPRESS_SETUP Messages” section on
page 3-34
FM Feature manager (only Catalyst 3550
switches)
“FM Messages” section on page 3-35
FRNTEND_CTRLR Front-end controller (only
Catalyst 3750 and 2975 switches)
“FRNTEND_CTRLR Messages” section on
page 3-44
GBIC Gigabit Interface Converter (GBIC)
module identification and validation
(only Catalyst 3550 switches)
“GBIC Messages” section on page 3-45
GBIC_SECURITY GBIC module and small form-factor
pluggable (SFP) module security
“GBIC_SECURITY Messages” section on
page 3-48
GBIC_SECURITY_CRYPT GBIC and SFP module security “GBIC_SECURITY_CRYPT Messages” section
on page 3-51
2-3
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
Chapter 2 System Message Overview
How to Read System Messages
GBIC_SECURITY_UNIQUE GBIC and SFP module security “GBIC_SECURITY_UNIQUE Messages” section
on page 3-52
GIGASTACK GigaStack GBIC module
(Catalyst 3550 switch only)
“GIGASTACK Messages” section on page 3-53
HARDWARE Hardware “HARDWARE Messages” section on page 3-54
HLFM Local forwarding manager “HLFM Messages” section on page 3-56
HPSECURE Port security “HPSECURE Messages” section on page 3-57
IDBMAN Interface description block manager “IDBMAN Messages” section on page 3-58
IGMP_QUERIER Internet Group Management Protocol
(IGMP) querier
“IGMP_QUERIER Messages” section on
page 3-61
ILPOWER Power over Ethernet (PoE) “ILPOWER Messages” section on page 3-62
IMAGEMGR Image manager (only Catalyst 3750
and 2975 switches)
“IMAGEMGR Messages” section on page 3-69
IP_DEVICE_TRACKING_HA IP device tracking for high availability “IP_DEVICE_TRACKING_HA Messages”
section on page 3-70
L2TM Layer 2 forwarding manager
(only Catalyst 3550 switches)
“L2TM Messages” section on page 3-71
L3TCAM Layer 3 unicast routing manager
(only Catalyst 3550 switches)
“L3TCAM Messages” section on page 3-71
MAC_LIMIT MAC address table entries “MAC_LIMIT Messages” section on page 3-72
MAC_MOVE Host activity “MAC_MOVE Messages” section on page 3-73
NETWORK_PORT_
SATELLITE
Network port satellite (only Catalyst
3550 switches)
“NETWORK_PORT_SATELLITE Messages
section on page 3-73
PAGP_DUAL_ACTIVE Port Aggregation Protocol (PAgP)
dual-active detection
“PAGP_DUAL_ACTIVE Messages” section on
page 3-74
PBR Policy-based routing (PBR)
(only Catalyst 3550 switches)
“PBR Messages” section on page 3-75
PHY PHY “PHY Messages” section on page 3-77
PIMSN Protocol Independent Multicast (PIM)
snooping
“PIMSN Messages” section on page 3-79
PLATFORM Low-level platform-specific “PLATFORM Messages” section on page 3-80
PLATFORM_FBM Platform fallback bridging manager “PLATFORM_FBM Messages” section on
page 3-81
PLATFORM_HPLM Platform pseudo label manager “PLATFORM_HPLM Messages” section on
page 3-83
PLATFORM_IPC Platform inter-process communication
protocol (only Catalyst 3750 and 2975
switches)
“PLATFORM _IPC Messages” section on
page 3-84
PLATFORM_PBR Platform policy-based routing “PLATFORM_PBR Messages” section on
page 3-86
Table 2-1 Facility Codes (continued)
Facility Code Description Location
2-4
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
Chapter 2 System Message Overview
How to Read System Messages
PLATFORM_PM Platform port manager “PLATFORM_PM Messages” section on
page 3-88
PLATFORM_RPC Platform remote procedure call (only
Catalyst 3750 and 2975 switches)
“PLATFORM_RPC Messages” section on
page 3-89
PLATFORM_SPAN Platform Switched Port Analyzer “PLATFORM_SPAN Messages” section on
page 3-91
PLATFORM_UCAST Platform unicast routing “PLATFORM_UCAST Messages” section on
page 3-92
PLATFORM_VLAN Platform VLAN “PLATFORM_VLAN Messages” section on
page 3-95
PLATFORM_WCCP Platform WCCP PLATFORM_WCCP Messages” section on
page 3-96
PM Port manager “PM Messages” section on page 3-97
PORT_SECURITY Port security “PORT_SECURITY Messages” section on
page 3-105
QATM QoS and ACL TCAM manager (only
Catalyst 3550 switches)
“QATM Messages” section on page 3-107
QM QoS manager (only Catalyst 3550
switches)
“QM Messages” section on page 3-108
QOSMGR QoS manager “QOSMGR Messages” section on page 3-111
RMON Remote Network Monitoring (RMON) “RMON Messages” section on page 3-117
SDM Switch Database Manager
(only Catalyst 3750 switches)
“SDM Messages” section on page 3-118
SPAN Switched Port Analyzer “SPAN Messages” section on page 3-118
SPANTREE Spanning Tree “SPANTREE Messages” section on page 3-119
SPANTREE_FAST Spanning-tree fast convergence “SPANTREE_FAST Messages” section on
page 3-127
SPANTREE_VLAN_SW Spanning-tree VLAN switch “SPANTREE_VLAN_SW Messages” section on
page 3-127
STACKMGR Stack manager (only Catalyst 3750 and
2975 switches)
“STACKMGR Messages” section on page 3-127
STORM_CONTROL Storm control “STORM_CONTROL Messages” section on
page 3-130
SUPERVISOR Supervisor ASIC “SUPERVISOR Messages” section on page 3-131
SUPQ Supervisor queue “SUPQ Messages” section on page 3-131
SW_DAI Dynamic ARP inspection “SW_DAI Messages” section on page 3-133
SW_MACAUTH MAC address authentication (only
Catalyst 3750 and 3560 switches)
“SW_MACAUTH Messages” section on
page 3-136
SW_VLAN VLAN manager “SW_VLAN Messages” section on page 3-137
Table 2-1 Facility Codes (continued)
Facility Code Description Location
2-5
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
Chapter 2 System Message Overview
How to Read System Messages
SEVERITY is a single-digit code from 0 to 7 that reflects the severity of the condition. The lower
the number, the more serious the situation.
Table 2-2 lists the message severity levels.
MNEMONIC is a code that uniquely identifies the message.
Message-text is a text string describing the condition. This portion of the message sometimes
contains detailed information about the event, including terminal port numbers, network addresses,
or addresses that correspond to locations in the system memory address space. Because the
information in these variable fields changes from message to message, it is represented here by short
strings enclosed in square brackets ([ ]). A decimal number, for example, is represented as [dec].
Table 2-3 lists the variable fields in messages.
SW_MATM Mac address table manager (only
Catalyst 3550 switches)
“SW_MATM Messages” section on page 137
SWITCH_QOS_TB QoS trusted boundary “SWITCH_QOS_TB Messages” section on
page 3-145
TCAMMGR Ternary content addressable memory
manager
“TCAMMGR Messages” section on page 3-145
UDLD UniDirectional Link Detection “UDLD Messages” section on page 3-147
UFAST_MCAST_SW UplinkFast packet transmission “UFAST_MCAST_SW Messages” section on
page 3-149
VQPCLIENT VLAN Query Protocol client “VQPCLIENT Messages” section on page 3-150
WCCP Web Cache Communication Protocol
(WCCP)
“WCCP Messages” section on page 151
WRLSCNTR Messages Catalyst 3750 Integrated Wireless LAN
Controller switch
“WRLSCNTR Messages” section on page 3-151
Table 2-1 Facility Codes (continued)
Facility Code Description Location
Ta b l e 2-2 Message Severity Levels
Severity Level Description
0 – emergency System is unusable.
1 – alert Immediate action required.
2 – critical Critical condition.
3 – error Error condition.
4 – warning Warning condition.
5 – notification Normal but significant condition.
6 – informational Informational message only.
7 – debugging Message that appears during debugging only.
2-6
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
Chapter 2 System Message Overview
How to Read System Messages
All syslog messages generated by a Catalyst 3750 and 2975 switch other than the master switch are
displayed ending with (Switch-x) where Switch-x is the number of the stack member generating the
message. Syslog messages generated by the master switch are displayed with no hostname string.
This example shows a partial switch system message on a switch other than a Catalyst 3750 and
2975 switch:
00:00:46: %LINK-3-UPDOWN: Interface Port-channel1, changed state to up
00:00:47: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to up
00:00:47: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to up
00:00:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
00:00:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed
state to down 2 *Mar 1 18:46:11: %SYS-5-CONFIG_I: Configured from console by vty2
(10.34.195.36)
18:47:02: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
*Mar 1 18:48:50.483 UTC: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
This example shows a partial switch system message for a stack master and a stack member switch
(hostname Switch-2) in a Catalyst 3750 switch stack or a Catalyst 2975 switch stack:
00:00:46: %LINK-3-UPDOWN: Interface Port-channel1, changed state to up
00:00:47: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/1, changed state to up
00:00:47: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/2, changed state to up
00:00:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
00:00:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/1, changed
state to down 2
*Mar 1 18:46:11: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
18:47:02: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
*Mar 1 18:48:50.483 UTC: %SYS-5-CONFIG_I: Configured from console by vty2 (10.34.195.36)
00:00:46: %LINK-3-UPDOWN: Interface Port-channel1, changed state to up (Switch-2)
00:00:47: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/1, changed state to up (Switch-2)
00:00:47: %LINK-3-UPDOWN: Interface GigabitEthernet1/0/2, changed state to up (Switch-2)
00:00:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface Vlan1, changed state to down
(Switch-2)
00:00:48: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet1/0/1, changed
state to down 2 (Switch-2)
Ta b l e 2-3 Representation of Variable Fields in Messages
Representation Type of Information
[dec] Decimal integer
[char] Single character
[chars] Character string
[enet] Ethernet address (for example, 0000.FEED.00C0)
[hex] Hexadecimal integer
[inet] Internet address
2-7
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
Chapter 2 System Message Overview
Error Message Traceback Reports
Error Message Traceback Reports
Some messages describe internal errors and contain traceback information. This information is very
important and should be included when you report a problem to your technical support representative.
This message example includes traceback information:
-Process= "Exec", level= 0, pid= 17
-Traceback= 1A82 1AB4 6378 A072 1054 1860
Some system messages ask you to copy the error messages and take further action. These online tools
also provide more information about system error messages.
Output Interpreter
The Output Interpreter provides additional information and suggested fixes based on the output of many
CLI commands, such as the the show tech-support privileged EXEC command. You can access the
Output Interpreter at this URL:
https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl
Bug Toolkit
The Bug Toolkit provides information on open and closed caveats, and allows you to search for all
known bugs in a specific Cisco IOS Release. You can access the Bug Toolkit at this URL:
http://www.cisco.com/cgi-bin/Support/Bugtool/home.pl
Contacting TAC
If you cannot determine the nature of the error, see the “Obtaining Documentation, Obtaining Support,
and Security Guidelines” section on page x for further information.
2-8
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
Chapter 2 System Message Overview
Error Message Traceback Reports
CHAPTER
3-1
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
3
Message and Recovery Procedures
This chapter describes the Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 switch system messages in
alphabetical order by facility. Within each facility, the messages are listed by severity levels 0 to 7: 0 is
the highest severity level, and 7 is the lowest severity level. Each message is followed by an explanation
and a recommended action.
The messages listed in this chapter do not include the hostname or the date/time stamp designation that
displays only if the software is configured for system log messaging.
The chapter includes these message facilities:
ACLMGR Messages, page 3-3
AUTOQOS Messages, page 3-8 (only Catalyst 3550 switches)
BACKUP_INTERFACE Messages, page 3-8
BADTRANSCEIVER Messages, page 3-9 (only Catalyst 3750 and 2975 switches)
BSPATCH Messages, page 3-9
CFGMGR Messages, page 3-10 (only Catalyst 3750 and 2975 switches)
CMP Messages, page 3-13
DHCP_SNOOPING Messages, page 3-14
DHCP_SNOOPING_CAT3550 Messages, page 3-17 (only Catalyst 3550 switches)
DOT1Q_TUNNELLING Messages, page 3-18 (only Catalyst 3550 switches)
DOT1X Messages, page 3-18
DOT1X_SWITCH Messages, page 3-19
DTP Messages, page 3-23
DWL Messages, page 3-24
EC Messages, page 3-25
ENVIRONMENT Messages, page 3-29 (only Catalyst 3550 switches)
ETHCNTR Messages, page 3-30
EXPRESS_SETUP Messages, page 3-34
FM Messages, page 3-35 (only Catalyst 3550 switches)
FRNTEND_CTRLR Messages, page 3-44 (only Catalyst 3750 and 2975 switches)
GBIC Messages, page 3-45 (only Catalyst 3550 switches)
GBIC_SECURITY Messages, page 3-48
3-2
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
Chapter 3 Message and Recovery Procedures
GBIC_SECURITY_CRYPT Messages, page 3-51
GBIC_SECURITY_UNIQUE Messages, page 3-52
GIGASTACK Messages, page 3-53 (only Catalyst 3550 switches)
HARDWARE Messages, page 3-54
HLFM Messages, page 3-56
HPSECURE Messages, page 3-57 (only Catalyst 3750 and 2975 switches)
IDBMAN Messages, page 3-58
IGMP_QUERIER Messages, page 3-61
ILPOWER Messages, page 3-62
IMAGEMGR Messages, page 3-69 (only Catalyst 3750 and 2975 switches)
IP_DEVICE_TRACKING_HA Messages, page 3-70
L2TM Messages, page 3-71 (only Catalyst 3550 switches)
L3TCAM Messages, page 3-71 (only Catalyst 3550 switches)
MAC_LIMIT Messages, page 3-72
MAC_MOVE Messages, page 3-73
NETWORK_PORT_SATELLITE Messages, page 3-73 (only Catalyst 3550 switches)
PAGP_DUAL_ACTIVE Messages, page 3-74
PBR Messages, page 3-75 (only Catalyst 3550 switches)
PHY Messages, page 3-77
PIMSN Messages, page 3-79 (only Catalyst 3750 and 3560 switches)
PLATFORM Messages, page 3-80
PLATFORM_HCEF Messages, page 3-82 (only Catalyst 3750 and 3560 switches)
PLATFORM_HPLM Messages, page 3-83 (only Catalyst 3750 and 3560 switches)
PLATFORM _IPC Messages, page 3-84 (only Catalyst 3750 and 2975 switches)
PLATFORM_IPv6 Message, page 3-85
PLATFORM_PBR Messages, page 3-86 (only Catalyst 3750 and 3560 switches)
PLATFORM_PM Messages, page 3-88
PLATFORM_RPC Messages, page 3-89 (only Catalyst 3750 and 2975 switches)
PLATFORM_SPAN Messages, page 3-91 (only Catalyst 3750 and 3560 switches)
PLATFORM_UCAST Messages, page 3-92 (only Catalyst 3750 and 3560 switches)
PLATFORM_VLAN Messages, page 3-95
PLATFORM_WCCP Messages, page 3-96 (only Catalyst 3750 and 3560 switches)
PM Messages, page 3-97
PORT_SECURITY Messages, page 3-105
QATM Messages, page 3-107 (only Catalyst 3550 switches)
QM Messages, page 3-108 (only Catalyst 3550 switches)
QOSMGR Messages, page 3-111
RMON Messages, page 3-117
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176

Cisco Catalyst 3750V2-48TS Switch User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI