Kobalt (Coleman) 215914 Owner's manual

Category
Air compressors
Type
Owner's manual

This manual is also suitable for

Digital Operator Manual
Manuel de I'op_rateur num_rique
Manual del Operador Digital
_E,_ __ Oilless, Single Stage, Direct Drive, Electric Air Compressors
_F,_,_,_, Sans I'huile, d'une seul 6tape, _ prise directe, compresseurs d'air 61ectriques
aciete, de una sola etapa, de mando directo, compresores de aire electricos
4
__E_g/;sh _kWARNING: Read and understand all safety precautions in this manual before operating. Failure to comply
with instructions in this manual could result in personal injury, property damage, and/or voiding of your warranty.
The manufacturer WILL NOT be liable for any damage because of failure to follow these instructions.
_Fte_ch AVERTISSEMENT : Lisez et veillez & bien comprendre toutes les consignes de s6curite de ce manuel avant
A
d'utiliser I'appareil. Toute derogation aux instructions contenues dans ce manuel peut entraP'her I'annulation de la
garantie, causer des blessures et/ou des d6g&ts materiels. Le fabricant NE SAURA 6tre tenu responsable de
dommages resultant de I'inobservation de ces instructions.
|Jms_,,:,h,_ ADVERTENClA:Leaycomprendatodaslasprecaucionesdeseguridadcontenidasenestemanualantesde
utilizar esta unidad. Si no cumple con las instrucciones de este manual podria ocasionar lesiones personales, dar_os a
la propiedad y/o la anulaci6n de su garantia. El fabricante NO SER,g. responsable de ningQn daSo por no acatar estas
instrucciones.
Printed in U.S.A. 200-2449_ Rev A_3-05
TABLE OF CONTENTS J
SAFETY GUIDELINES ........................... 3
OVERVIEW ................................... 6
Basic Air Compressor Components ............. 6
ASSEMBLY ................................... 7
Assembling the Compressor ................... 7
COMPRESSOR CONTROLS ...................... 8
Digital Control Panel ......................... 8
ELECTRICAL POWER REQUIREMENTS ........... 11
Electrical Wiring ............................ 11
Extension Cords ........................... 11
Grounding Instructions ...................... 11
BREAK-IN OF THE PUMP ....................... 13
OPERATING INSTRUCTIONS .................... 14
Daily Startup .............................. 14
Shutdown ................................. 14
MAINTENANCE ............................... 16
Draining the Tank .......................... 16
Checking the Relief Valve .................... 16
Testing for Leaks ........................... 16
Storage .................................. 16
SERVICE INTERVAL ........................... 17
TROUBLESHOOTING CHART ................... 18
GLOSSARY OF TERMS ........................ 22
TABLE DES MATII_RES I
CONSIGNES DE SECURITE ...................... 4
VUE D'ENSEMBLE .............................. 6
Elements de base du compresseur d'air .......... 6
ASSEMBLAGE ................................. 7
Assemblage du compresseur .................. 7
COMMANDES DU COMPRESSEUR ................ 9
Panneau de commande numerique .............. 9
SPECIFICATIONS DE L'ALIMENTATION
ELECTRIQUES ............................. 11-12
C&blage electrique .......................... 11
Rallonges .............................. 11-12
Instructions de mise a la terre ................. 12
RODAGE DE LA POMPE ........................ 13
MODE D'EMPLOI ........................... 14-15
Mise en marche quotidienne .................. 14
Arr6t ..................................... 15
ENTRETIEN .................................. 16
Vidange du reservoir ........................ 16
Verification de la soupape de decharge ......... 16
Essai d'etanch6it6 .......................... 16
Entreposage .............................. 16
ENTRETIEN PERIODIQUE ...................... 17
DEPANNAGE ................................. 19
GLOSSAIRE .................................. 22
INDICE I
PAUTAS DE SEGURIDAD ........................ 5
RESUMEN GENERAL ........................... 6
Componentes basicos del compresor de aire ...... 6
MONTAJE ..................................... 7
Montaje del compressor ...................... 7
CONTROLES DEL COMPRESOR ................. 10
Panel de Control Digital ...................... 10
REQUERIMIENTOS DE ALIMENTAClON ELECTRICA 12
Cableado electrico .......................... 12
Cordones prolongadores ..................... 12
Instrucciones de conexion a tierra .............. 12
MARCHA INIClAL DEL BOMBA ................... 13
INSTRUCClONES OPERATIVAS ................. 15
Arranque diario ............................ 15
Parada ................................... 15
MANTENIMIENTO ............................. 16
DesagQe del tanque ......................... 16
Revision de la v&lvula de alivio ................ 16
Deteccion de fugas ......................... 16
Almacenamiento ........................... 16
INTERVALOS DE SERVICIO ..................... 17
CUADRO DE DETECCION DE FALLOS ......... 20-21
GLOSARIO DE TERMINOS ...................... 22
2 200-2449
I_:_g_,_h SAFETY GUIDELINES
The following information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this
information, we use the following symbols. Please read the manual and pay attention to these sections.
,_ _ - A POTENTIAL HAZARD THAT WILL CAUSE SERIOUS INJURY OR LOSS OF LIFE.
_ - A POTENTIAL HAZARD THAT COULD CAUSE SERIOUS INJURY OR LOSS OF LIFE.
rl_'_"j"j"_'_ _ A POTENTIAL HAZARD THAT MAY CAUSE MODERATE INJURY OR DAMAGE TO EQUIPMENT.
1. RISK OF FIRE OR EXPLOSION. Never spray
flammable liquids in a confined area. It is normal for
:_1_ the motor and pressure switch to produce sparks
while operating. If sparks come into contact with
vapors from gasoline or other solvents, they may
ignite, causing fire or explosion. Always operate the
compressor in a well-ventilated area. Do not smoke
while spraying. Do not spray where sparks or flame
are present. Keep compressor as far from spray area
as possible.
RISK OF BURSTING. Rust can weaken the tank.
Drain the condensed water from the tank after each
use to reduce rusting. If a leak is detected in the tank,
replace the tank immediately. Do not weld, drill or
modify the air tank of this compressor. Welding or
modifications on the air compressor tank can severely
impair tank strength and cause an extremely
hazardous condition. Welding or modifying the tank in
any manner will void the warranty.
RISK OF ELECTRICAL SHOCK. A licensed
electrician in accordance with all local and national
codes must install all wiring. Never use an electric air
compressor outdoors when it is raining or on a wet
surface, as it may cause an electric shock.
RISK OF INJURY. This unit starts automatically.
ALWAYS shut off the compressor, remove the plug
from the outlet, and bleed all pressure from the
system before servicing the compressor, and when
the compressor is not in use. Do not operate the unit
with the shroud removed. Serious injury could occur
from contact with moving parts.
RISK OF BURSTING. Check the manufacturer's
maximum pressure rating for air tools and
accessories. Compressor outlet pressure must be
regulated so as to never exceed the maximum
pressure rating of the tool. Relieve all pressure
through the hose before attaching or removing
accessories.
6.
7.
8.
9.
10.
11.
12.
13.
RISK OF BURNS. High temperatures are generated
by the pump and manifold. To prevent burns or other
injuries, DO NOT touch the pump, manifold or
transfer tube while the pump is running. Allow them to
cool before handling or servicing. Keep children away
from the compressor at all times.
RISK TO BREATHING. Be certain to read all labels
when you are spraying paints or toxic materials, and
follow the safety instructions. Use a respirator mask if
there is a chance of inhaling anything you are
spraying. Read all instructions and be sure that your
respirator mask will protect you.
RISK OF EYE INJURY. Always wear ANSI Z87.1
approved safety goggles when using an air
compressor. Never point any nozzle or sprayer toward
a person or any part of the body. Equipment can
cause serious injury if the spray penetrates the skin.
RISK OF BURSTING. Do not tamper with the control
board or adjust the relief valve for any reason. Doing
so voids all warranties. They have been preset at the
factory for the maximum pressure of this unit.
Personal injury and/or property damage may result if
the control board or the relief valve are tampered with.
RISK OF BURSTING. Do not use plastic or pvc pipe
for compressed air. Use only galvanized steel pipe
and fittings for compressed air distribution lines.
RISK TO HEARING. Always wear hearing protection
when using an air compressor. Failure to do so may
result in hearing loss.
RISK TO BREATHING. Never directly inhale the
compressed air produced by a compressor. It is not
suitable for breathing purposes.
The power cord on this product contains lead, a
chemical known to the State of California to cause
cancer, and birth defects or other reproductive harm.
Wash hands after handling.
]
A_
1. Drain the moisture from the tank on a daily basis. A
clean, dry tank will help prevent corrosion.
2. Pull the pressure relief valve ring daily to ensure that
the valve is functioning properly, and to clear the
valve of any possible obstructions.
3. To provide proper ventilation for cooling, the
compressor must be kept a minimum of 12 inches (31
cm) from the nearest wall, in a well-ventilated area.
4. Fasten the compressor down securely if transporting
is necessary. Pressure must be released from the
tank before transporting.
5.
6.
7.
Protect the air hose and electric cord from damage
and puncture. Inspect them weekly for weak or worn
spots, and replace if necessary.
To reduce the risk of electric shock, do not expose to
rain. Store indoors.
Never operate the compressor if the power cord or
plug are damaged. Take the equipment to the nearest
Authorized Service Center, and have a Technician
replace it.
200-2449 3
OVERVIEW \ VUE D'ENSEMBLE \ RESUMEN GENERAL ]
I[_C]E'_; _ BASIC AIR COMPRESSOR COMPONENTS I
Oilless air compressors are factory lubricated for life and
do not require any oil.
The basic components of the air compressor are the
electric motor, pump, digital control panel and tank. The
electric motor (see A) powers the pump. The electric motor is
equipped with an overload protector and an automatic reset. If
the motor becomes overheated, the overload protector will
shut it down to prevent damage to the motor. When the motor
sufficiently cools, it will automatically restart.
The pump (see B) compresses the air and discharges it
into the tank.
The tank (see C) stores the compressed air.
The digital control panel (see D) consists of the on/off
button (E), tank pressure button (F), digital display window (G)
and a tank pressure indicator (H).
As compressed air is used and the pressure level in the
tank drops to the kick-in pressure, the control board restarts
the motor automatically, without warning, and the pump
resumes compressing air. The control board shuts down the
motor when the air pressure in the tank reaches the cut-out
pressure. The functions of these components are described on
pages 8-10.
I_,:,_,c!_ €:LC:MENTSDE BASE gu COMPRESSEUR D'AIR I
Les compresseurs d'air sans huile sont lubrifies & I'usine
et ne requierent aucun huilage.
Les composants de base du compresseur d'air sont le
moteur electrique, la pompe, le panneau de commande
numerique et le reservoir.
Le moteur 61ectrique (A) actionne la pompe. Le moteur
electrique est 6quipe d'un limiteur de surcharge
reenclenchement automatique. Si le moteur surchauffe, le
limiteur coupe I'alimentation pour eviter d'endommager le
moteur. Lorsque le moteur est suffisamment refroidi, il
redemarre automatiquement.
La pompe (B) comprime I'air.
Le r6servoir (C) contient I'air comprime.
Le panneau de commande numerique (voir D) comprend la
touche marche/arr&t (E), la touche de pression du reservoir
(F), la fen&tre d'affichage numerique (G) et I'indicateur de
pression du reservoir (H).
Lorsque I'appareil utilise de I'air comprime et Iorsque le
niveau de pression du reservoir tombe a la pression de
demarrage, le tableau de commande fait redemarrer
automatiquement le moteur, sans avertissement et la pompe
recommence a comprimer I'air. Le tableau de commande
coupe le moteur Iorsque la pression d'air du reservoir atteint la
pression de coupure. Les fonctions de ces composants sont
decrites aux pages 8 a 10.
Los compresores de aire sin aceite se lubrican en f4_brica
para toda su vida Qtil, y no requieren aceite.
COMPONENTES BASlCOS DEL
COMPRESOR DE AIRE
Los componentes b4_sicos del compresor de aire son el
motor electrico, la bomba, el panel de control digital y el
tanque.
El motor el_ctrico (vea A) acciona la bomba. El motor
electrico est& equipado con un protector contra sobrecargas y
un reajuste autom4_tico. Si el motor se sobrecalienta, el
protector contra sobrecargas Io apagara para evitar que sufra
dar_os. Cuando el motor se enfrie Io suficiente, volver& a
arrancar autom&ticamente.
La bomba (vea B) comprime el aire y Io descarga hacia el
tanque.
El tanque (vea C) almacena el aire comprimido.
El panel de control digital (ver D) consta del bot6n de
encendido/apagado (ON/OFF) (E), del bot6n para la presi6n
del tanque (F), de la ventana de la pantalla digital (G) y del
indicador de la presi6n del tanque (H).
AI utilizar el aire comprimido y cuando el nivel de presi6n
del tanque baja hasta la presion de arranque, el tablero de
control reinicia autom&ticamente el motor, sin advertencia, y la
bomba comienza a comprimir el aire. El tablero de control
apaga el motor cuando la presi6n del aire en el tanque
alcanza la presi6n de corte. Las funciones de estos
componentes se describen en las p4_ginas 8 a 10.
D
A&B
C
\
\
E
A&B
6 200-2449
1
1.
ASSEMBLY/ASSEMBLAGE I
ASSEMBLING THE COMPRESSOR I
i
Unpack the air compressor, inspect the unit for damage, if
the unit has been damaged in transit, contact the carrier
and complete a damage claim. Do this immediately
because there are time limitations to damage claims.
The carton should contain:
air compressor
handle
operator and parts manuals
2. Check the compressor's serial label to ensure that you
have received the model ordered, and that it has the
required pressure rating for its intended use.
3. If necessary for your model, install the handle (see A) by 1.
inserting the ends into the base and secure with the bolts
(see B) provided (see Fig. 2). Tighten bolts against base
using a 3/8" socket or wrench (not included).
4. Locate the compressor according to the following
guidelines:
a. Position the compressor near a grounded electrical
outlet (see GROUNDING INSTRUCTIONS, page 10).
b. The compressor must be at least 12 inches (31 cm)
from any wall or obstruction, in a clean, well-ventilated
area, to ensure sufficient air flow and cooling.
c. in cold climates, store portable compressors in a 2.
heated building when not in use. This will reduce
problems with motor starting and freezing of water
condensation.
_' _ The shipping pallet is not designed as a
base for an operating compressor.
d. Remove the compressor from the shipping pallet or
carton and place it on the floor or a hard, level surface.
The compressor must be level to ensure proper
drainage of the moisture in the tank.
5. Connect an air hose (not included) to the compressor hose
outlet (see item G on page 8).
ASSEMBLAGE DU COMPRESSEUR I
i
1. Sortez le compresseur d'airde sa bofte. Inspectez-le pour
vous assurer qu'il n'est pas endommage. S'i a et6
endommage pendant le transport, r6ferez-vous A
I'etiquette de transport et declarez les dommages aux
transporteur. Faites cette demarche immediatement etant
donne les delais limites des demandes d'indemnisation.
Le carton dolt contenir:
compresseur d'air
poignee
manuel de I'operateur et manuel de pieces
2. Verifiez I'etiquette du numero de serie du compresseur
pour vous assurer qu'il s'agit bien du modele commande et
que la pression nominale est conforme A I'utilisation
prevue.
3. Si cela est necessaire pour votre modele, installez la
poignee (A) en inserant les extremit6s dans la base et en
les fixant A I'aide des boulons (B) foumis (Fig. 2). Apriete
los pernos contra la base con una llave de 3/8" (no
incluida).
4. Positionnez le compresseur conformement aux
recommandations suivantes :
a. Placez le compresseur pres d'une prise de courant
mise A la terre (voir INSTRUCTIONS DE MISE
,ik LA TERRE, p. 11).
b. Le compresseur dolt 6tre situe A au moins 12 pouces
(31 cm) du mur ou de tout objet faisant obstruction,
dans un endroit propre et bien aer6 pour assurer une
circulation d'air suffisante et un bon refroidissement.
c. Dans des climats froids, entreposez les compresseurs
portatifs dans un b&timent chauffe Iorsqu'ils ne sont
pas en service pour reduire les problemes de
lubrification, de demarrage du moteur et de gel de
I'eau produite par condensation.
_" _:La palette d'exp_dition n'est pas
congue pour servir de base & un compresseur en
marche.
d. Enlever le compresseur de la pallette d'expedition ou
du carton et le placer sur une surface solide et de
niveau. Le compresseur dolt 6tre de niveau pour
assurer un bon drainage de I'humidite du reservoir.
5. Raccorder le tuyau pneumatique (non inclus) A la sortie du
compresseur (volt article G, p. 9).
MONTAJE DEL COMPRESOR I
Desembale el compresor de aire. Inspeccione la unidad
para verificar que no sufri6 daSos. Si la unidad ha sido
daSada durante el transporte, comuniquese con la
empresa transportadora y complete una reclamacion por
daSos. Haga esto de inmediato porque existen
limitaciones de tiempo respecto alas reclamaciones por
daSos.
La caja debe contener los elementos siguientes:
compresor de aire
• manija
manual del operador y manual de piezas
Verifique el rotulo del nOmero de serie del compresor para
asegurarse de que haya recibido el modelo que pidio
y que el mismo tenga la presi6n nominal requerida para el
uso deseado.
3. Si es necesario para su modelo, instale la manija (vea A)
introduciendo los extremos en la base y asegurandolos
con los 2 pernos (vea B) provistos (Fig. 2). Serrez les
boulons contre la base A I'aide d'une cl6 A douille ou autre
cl6 de 3/8 po (non incluse).
4. Ubique el compresor de acuerdo con las pautas
siguientes:
a. Ubique el compresor cerca de un tomacorriente
electrico conectado a tierra (consulte
INSTRUCClONES DE PUESTA A TIERRA, vea
11).
b. El compresor debe estar a una distancia minima de
12 pulgadas (31 cm) de cualquier pared u
obstruccion, en un Area limpia y bien ventilada para
asegurar que exista suficiente flujo de aire y
enfriamiento.
c. En climas frios, almacene el compresor portatil en un
edificio con calefaccion. Esto reducira problemas de
lubricaci6n, arranque del motor y congelamiento del
agua de condensacion.
A
La plataforma de embarque no est_
diseSada para servir de base de un compresor
en operaci6n.
d. Separe el compresor de la plataforma de
transportacion y col6quelo en el piso, sobre una
superficie dura y nivelada. El compresor debe quedar
nivelado para asegurar un drenaje adecuado del
agua de humedad del tanque.
5. Conecte una manguera de aire (no se incluye) en la
salida de la manguera del compresor (vea articulo G, p. 10).
Fig. 2
200-2449 7
I COMPRESSOR CONTROLS I
DIGITAL CONTROL PANEL
On/Off Button (see A)
LCD Display Window (see B)
Tank Pressure Button (see C)
Tank Pressure Indicator (see D)
#Vhen the unit is plugged in, this button turns the compressor on. It is operated
-nanually, but when in the ON position, it allows the compressor to start up or shut _ I 4,
down automatically, without warning, upon air demand. The on/off icon will be shown
3n the display. ALWAYS turn the unit OFF when the compressor is not being used,
and before unplugging the compressor.
This display will automatically show the regulated outlet pressure when the , I,
Jnit is on. The on/off icon and the tool icon will be shown on the display.
(ij
%
The display will automatically show the tank pressure when the unit is off but still plugged in, if
ihe pressure is not zero.
_ressing this button will show the pressure level of the air stored in the tank and the
iank icon will be shown in the display. It is not adjustable by the operator and does
qot indicate line pressure.
Releasing this button will return the display to regulated pressure and the ,I, _'1"--_1
3n/off icon and the tool icon will be shown in the display. It is not adjustable
oy the operator and does not indicate line pressure.
This indicator will assume a red color when the tank is pressurized.
#Vhen there is zero tank pressure the indicator will not be visible.
_1_ _1'_Risk of injury. Before transporting or performing any type of service to the unit, always shut off the compressor,
remove the plug from the outlet and bleed all the pressure from the system through the outlet hose or by pulling the relief valve
ring and opening the petcock on the bottom of the tank (see the "Maintence" section of this manual for instructions).
Pressure Relief Valve (see E) If the control board does not shut down the motor when the pressure reaches the preset level,
ihis valve will pop open automatically to prevent over pressurization. To operate manually, pull
ihe ring on the valve to relieve air pressure in the tank.
Air Pressure Regulator Knob The air pressure regulator knob enables you to adjust line pressure to the tool you are using.
(see F) Turn the regulator knob clockwise to increase the regulated pressure and counter clockwise to
decrease the regulated pressure (see H).
_Never Exceed the maximum working pressure of the tool. Turn the knob clockwise to increase pressure and
counterclockwise to decrease pressure.
Air Line Outlet (see G) Sonnect a _¼"female connector and a _¼"air hose to this outlet (not included with some
sompressors) (see I).
B
8 200-2449
I
ELECTRICAL WIRING
ELECTRICAL POWER REQUIREMENTS
SPI_CIFICATIONS DE L'ALIMENTATION I_LECTRIQUE
REQUERIMIENTOS DE ALIMENTACION ELI_CTRICA
I Check with a licensed electrician if the grounding instructions
are not completely understood, or if in doubt as to whether the
product is properly grounded. Do not modify the plug provided;
if it will not fit the outlet, have the proper outlet installed by a
licensed electrician.
Refer to the air compressor's serial label for the unit's
voltage and amperage requirements.
Use a dedicated circuit.
For best performance and reliable starting, the air
compressor must be plugged into a dedicated circuit, as
close as possible to the fusebox or circuit breaker. The
compressor will use the full capacity of a typical 15 amp
household circuit. If any other electrical devices are drawing
from the compressor's circuit, the compressor may fail to start.
Low voltage or an overloaded circuit can result in sluggish
starting that causes the motor overload protection system or
circuit breaker to trip, especially in cold conditions.
NOTE: A circuit breaker is recommended. If the air
compressor is connected to a circuit protected by a fuse, use
dual element time delay fuses (Buss Fusetron type "T" only).
EXTENSION CORDS I
NOTE: Avoid use of extension cords.
For optimum performance, plug the compressor power
cord directly into a grounded wall socket. Do not use an
extension cord unless absolutely necessary, instead, use a
longer air hose to reach the area where the air is needed.
If use of an extension cord cannot be avoided, the cord
should be no longer than 100 feet and be a minimum wire size
of 12 gauge (AWG). Do not use a 16 or 14 gauge extension
cord.
Use only a 3-wire extension cord that has a 3-blade
grounding plug, and a 3-slot receptacle that will accept the plug
on the product. Make sure your extension cord is in good
condition. An undersized cord will cause a drop in line voltage,
resulting in loss of power and overheating. The smaller the
gauge number, the heavier the cord.
GROUNDING INSTRUCTIONS I
This product should be grounded. In the event of an
electrical short circuit, grounding reduces the risk of electric
shock by providing an escape wire for the electric current.
This product is equipped with a cord having a grounding
wire with an appropriate grounding plug. The plug must be
plugged into an outlet that is properly installed and grounded in
accordance with all local codes and ordinance.
_ Improper installation of the grounding
plug can result in a risk of electric shock. If repair or
replacement of the cord or plug is necessary, do not
connect the grounding wire to either flat blade
terminal. The wire insulation having an outer surface
that is green with or without yellow stripes is the
grounding wire.
This product is for use on a nominal 115 volt circuit. A cord
with a grounding plug, as shown here, shall be used.
Make sure that the product is connected to an outlet
having the same configuration as the plug (see Figure 1). No
adapter should be used with this product.
CABLAGE F:LECTIQUE
Pour vous renseigner sur les normes d'intensite et de
tension de I'appareil, refGrez-vous a I'etiquette du numero de
serie du compresseur d'air.
I
Utilisez un circuit s6par&
Pour obtenir le meilleur rendement possible et une
mise en marche fiable, le compresseur d'air doit 6tre
install_ sur un circuit s_par6, aussi pros que possible
d'une boite & fusibles ou d'un disjoncteur. Le compresseur
utilise toute la capacite d'un circuit a usage domestique typique.
Si d'autres appareils electriques tirent du courant sur le circuit
du compresseur, il est possible que le compresseur ne puisse
pas demarrer. Si la tension est insuffisante ou si le circuit est
surcharge, le demarrage risque d'Gtre lent et d'entrafner en
consequence le declenchement du disjoncteur ou de
I'interrupteur de remise en marche du moteur, surtout s'il fait
froid.
REMARQUE : II est recommande d'utiliser un disjoncteur.
Si le compresseur est branche sur un circuit proteg6 par un
fusible, utilisez des fusibles temporises & double el6ment (Buss
Fusetron de type <<T>>seulement).
RALLONGES I
REMARQUE : Evitez d'utiliser des rallonges.
Pour obtenir un rendement optimum, branchez le c_ble
d'alimentation du compresseur directement sur une prise de
courant mise a la terre. N'utilisez pas de rallonge sauf
nGcessite absolue. Utilisez plutGt un tuyau flexible plus long
pour atteindre la zone oQ I'air est necessaire.
S'il I'utilisation d'une rallonge est inevitable, le cordon
electrique ne dolt pas depasser 30 m (100 pi) et dolt 6tre d'un
calibre minimum de 12 (AWG). N'utilisez pas une rallonge de
calibre 16 ou 14.
Figure 1
Grounded Outlet
Box
Grounded Outlet
115 VOLTS _-_
15 AMP
Pluc
g Pin
200-2449 1
BREAK-IN OF THE PUMP \ RODAGE DE LA POMPE \ MARCHA DE LA BOMBA
[
BREAK-IN OF THE PUMP
1. Open the petcock (see B). Turn in the counterclockwise
direction.
2. Plug in the power cord.
3. Press the ontoff button to the ON position (the on/off
icon will show in the top left corner of the display) (see
C). The compressor will start. Allow the compressor to run
for 15 minutes, to break in the internal parts.
NOTE: After about 15 minutes, If the unit does not operate
properly, SHUT DOWN IMMEDIATELY, and contact
Product Service.
4. After about 15 minutes, press the on/off button to the OFF
position (the on/off icon will no longer be visible in the
top left corner of the display).
5. Close the petcock (see D). Turn in the clockwise direction.
6. Press the on/off button to the ON position. The compressor
will start and fill the tank to the kick-out pressure and stop.
NOTE: As compressed air is used, the pressure switch will
restart the motor automatically.
NOTE: During the initial break-in cycle, there will be a slight
electrical smell as the motor brushes seat. This is
normal for universal motors and will last for about 5
minutes.
RODAGE DE LA POMPE I
1. Ouvrez le robinet de purge (B). Tourner le bouton vers la
droite.
2. Branchez le cordon d'alimentation.
3. Enfoncez la touche marche/arr6t a la position MARCHE
(l'ic6ne marche/arr6t apparaftra dans le coin superieur
gauche de I'affichage) (voir C).
Le compresseur demarre. Laissez tourner pendant 15
minutes pour roder les pieces internes.
REMARQUE : Si apres 15 minutes I'appareil ne fonctionne
pas correctement, ARRETEZ-LE
IMMEDIATEMENT et contactez le service
apres-vente.
4. Apres 15 minutes, enfoncez la touche marche/arr6t a la
position ARRET (l'ic6ne marche/arr6t ne sera plus visible
dans le coin superieur gauche de I'affichage).
5. Fermez le robinet de purge (D).
6. Enfoncez la touche marche/arr6t a la position marche.
Toumer vers la droite. Le compresseur demarre et remplit
le reservoir jusqu'a la pression de fermeture, puis s'arr6te.
REMARQUE:
REMARQUE:
1.
2.
3.
Une lois que suffisamment d'air comprime
est utilise, le manostat relance
automatiquement le moteur
Pendant le cycle rodage initial, il y aura une
16gere odeur electrique comme le moteur
balaye le siege. C'est normal pour les
moteurs universels et la volonte durent
pendant environ 5 minutes.
MARCHA INICIAL DE LA BOMBA I
Abra la Ilave de descompresion (vea B). H&galo girar hacia
la izquierda.
Enchufe el cordon electrico.
Presione el bot6n de encendido/apagado (on/off) para
dejarlo en la posici6n de encendido (ON) (el icono de
encendido/apagado aparecer& en la esquina superior
izquierda de la pantalla) (ver C). El compresor arrancar&
200-2449
OUVERT D
ABIERTO CLOSE
", FERMI_
" SE CIERRAN'x "/
", I/
Permita el funcionamiento del compresor durante 15
minutos, a fin de suavizar los componentes internos.
NOTA: Si despues de 15 minutos la unidad no opera
correctamente, AP/kGUELA INMEDIATAMENTE y
pongase en contacto con el Centro de Servicio.
4. Despues de 15 minutos, presione el bot6n de
encendido/apagado (on/off) para dejarlo en la posici6n de
apagado (OFF) (el icono de encendidotapagado ya no
estar& visible en la esquina superior izquierda de la
pantalla).
5. Cierre la Ilave de descompresion. (vea D).
6. Presione el boton de encendido/apagado (on/off) para
dejarlo en la posicion de encendido (ON). Hagalo girar
hacia la derecha. El compresor comenzar& a funcionar,
Ilenar& el tanque hasta la presion de desconexion y dejara
de funcionar.
NOTA: AI utilizar el aire comprimido, el interruptor de
presion arrancara automaticamente el motor.
NOTA: Durante el ciclo de adaptacion inicial, habr& un olor
electrico leve como el motor cepilla el asiento. Esto es
normal para los motores universales y la voluntad
dura pot cerca de 5 minutos.
13
1
1.
2.
3.
4.
5.
2.
3.
4.
1.
2.
3.
4.
14
OPERATING INSTRUCTIONS \ MODE D'EMPLOI \ INSTRUCCIONES OPERATIVAS
DAILY STARTUP I
Close the tank petcock (see D). Turn in the clockwise
direction.
Plug in the power cord.
_High temperatures are generated
by the electric motor and the pump. To prevent burns
or other injuries, DO NOT touch the compressor while
it is running. Allow it to cool before handling or
servicing. Keep children away from the compressor
at all times.
Press the on/off button to the ON position (the on/off
icon will show in the top left corner of the display) (see
C).
,_ _When adjusting from a higher to a
lower pressure, turn the knob counterclockwise past
the desired setting, then turn clockwise to reach the
desired pressure. Do not exceed operating pressure of
the tool or accessory being used.
Adjust the regulator to the working pressure of the tool by
turning the regulator knob clockwise to increase pressure
(A) and counterclockwise to decrease the pressure (E).
To see how much pressure is in the tank, press and hold
the tank pressure button down (see G).
SHUTDOWN I
Press the on/off button to the OFF position (the on/off
icon will no longer be visible in the top left corner of the
display).
Unplug the power cord.
Reduce pressure in the tank through the outlet hose. You
can also pull the relief valve ring (see F) and keep it open
to relieve pressure in the tank.
_k _ Escaping air and moisture can
propel debris that may cause eye injury. Wear safety
goggles when opening petcock.
Open the petcock (see B) to allow moisture to drain from
the tank.
MISE EN MARCHE QUOTIDIENNE I
Fermez le robinet de purge du reservoir (D). Tourner vers
la droite.
Branchez le cordon d'alimentation.
-' _ _ • La pompe et le moteur
electrique produisent des temperatures elev6es.
Pour eviter les brQlures et autres blessures, NE
touchez PAS le compresseur quand il est en marche.
Laissez-le refroidir avant de le manipuler ou
d'effectuer son entretien. Ne laissez jamais les
enfants s'approcher du compresseur.
Enfoncez la touche marche/arr6t & la position MARCHE
(l'ic6ne marche/arr6t apparaftra dans le coin superieur
gauche de I'affichage) (voir C).
dl_ -' _ i= • Pour passer d'une
pression elev6e & une pression plus basse, tournez le
bouton dans le sens contraire des aiguilles d'une
montre au-del& du reglage de pression desir6, puis
tournez-le dans le sens des aiguilles d'une montre
pour atteindre la pression desir6e. Ne pas depasser la
pression de fonctionnement de l'outil ou de
l'accessoire utilis&
Ajustez le regulateur a la pression de service de l'outil en
toumant le bouton du regulateur dans le sens des aiguilles
G
OPEN
OUVERT D
ABIERTO CLOSE
",, FERME
" /" SE CIERRAN
N
, 7 "/
pour augmenter la pression (A) et dans le sens contraire
pour reduire la pression (E).
Pour voir combien de pression il y a dans le reservoir,
appuyez et gardez la touche de pression du reservoir
enfoncee (voir G).
200-2449
I
A
"'°-'L''"'L''To avoid personal injury, always shut off and
unplug the compressor and relieve all air pressure from
the system before performing any service on the air
compressor.
Regular maintenance will ensure trouble free operation.
Your electric powered air compressor represents high quality
engineering and construction; however, even high quality
machinery requires periodic maintenance. The items listed
below should be inspected on a regular basis.
DRAINING THE TANK I
I
_1_ _Condensation will accumulate in the
tank. To prevent corrosion of the tank from the inside,
this moisture must be drained at the end of every
workday. Be sure to wear protective eyewear. Relieve
the air pressure in the system and open the petcock
on the bottom of the tank to drain (See B and D) on
pages 13, 14 and 15.
NOTE: In cold climates, drain the tank after each use to
reduce problems with freezing of water
condensation.
CHECKING THE RELIEF VALVE J
Pull the relief valve daily to ensure that it is operating
properly and to clear the valve of any possible obstructions.
TESTING FOR LEAKS I
I
MAINTENANCE \ ENTRETIEN \ MANTENIMIENTO I
d
MAINTENANCE J [I_IiF,'_h VERIFICATION DE LA SOUPAPE DE DI_CHARGEJ
Tirezchaque jour sur lasoupape de decharge pour vous
assurer qu'ellefonctionne correctement et eliminertoutes les
obstructions6ventuelles.
Check that all connections are tight. A small leak in any of
the hoses or pipe connections will substantially reduce the
performance of your air compressor. If you suspect a leak,
spray a small amount of soapy water around the area of the
suspected leak with a spray bottle. If bubbles appear, repair or
replace the faulty component. Do not overtighten any
connections.
STORAGE
Before storing the compressor for a prolonged period, use
an air blow gun to clean all dust and debris from the
compressor. Disconnect the power cord and coil it up. Pull the
pressure relief valve to release all pressure from the tank.
Drain all moisture from the tank. Cover the entire unit to protect
it from moisture and dust.
ENTRETIEN J
-' _ u • Pour eviter les risques de
blessures, arr6tez et debranchez toujours le compresseur
et liberez toute la pression d'air dans le circuit avant
de proceder a I'entretien.
L'entretien r6gulier de I'appareil permettra d'assurer un
fonctionnement sans problemes. Votre compresseur d'air
61ectrique est un appareil de haute qualite ; toutefois, m6me les
machines de haute qualite necessitent un entretien periodique.
Les composants enum6r6s ci-dessous doivent 6tre inspectes
requli6rement.
VIDANGE DU R_:SERVOIR I
d
,i_ -' _ u • De la condensation se
forme dans le reservoir. Pour eviter la formation de
corrosion depuis I'interieur du reservoir, cette
condensation dolt 6tre 6vacuee & la fin de chaque
journee de travail. Veillez & porter des lunettes de
protection. Liberez la pression d'air dans le circuit et
ouvrez le robinet de purge en bas du reservoir pour
vidanger (Voir Bet D) aux pages 13, 14 et 15.
REMARQUE :Dans les climats froids, purger le reservoir
apres chaque utilisation afin de reduire les problemes de gel
d'eau de condensation.
ESSAI D'#TANCHEIT#
Assurez-vous que tousles raccords sont serres. Le
rendement de votre compresseur peut 6tre reduit de maniere
significative en presence d'une petite fuite d'air dans les tuyaux
fiexibles, ou les raccords de tuyauterie. Si vous suspectez une
fuite, vaporisez un peu d'eau savonneuse autour de la zone. Si
des bulles apparaissent, reparez ou remplacez le composant
defectueux. Ne serrez pas trop.
ENTREPOSAGE
Avant d'entreposer le compresseur pour une periode
prolongee, utilisez une soufflette pour nettoyer toute la
poussiere et tousles debris du compresseur. Debranchez le
cordon d'alimentation et enroulez-le. Tirez sur la soupape de
decharge pour liberer toute la pression dans le reservoir.
Evacuez toute I'humidite du reservoir. Couvrez tout I'appareil
pour le proteger de I'humidite et de la poussiere.
MANTENIMIENTO
_Para evitar lesiones personales,
siempre apague y desenchufe el compresor y alivie toda la
presiGn de alre del sistema antes de realizar algQn tipo de
servicio en el compresor de aire.
El mantenimiento regular asegurar& una operacion sin
problemas. Su compresor de aire con alimentacion electrica
representa Io mejor en ingenieria y construccion; sin embargo,
ann la maquinaria de mejor calidad requiere un mantenimiento
periodico. Los elementos enumerados a continuacion deben
inspeccionarse de manera regular.
DESAGUE DEL TANQUE
A
_'_a condensacion se
i]]_ cumulara en el tanque. Para evitar la corrosion del
tanque desde el interior, esta humedad debe ser
drenada al final de cada dia de trabajo. AsegQrese de
utilizar proteccion ocular. Alivie la presion de aire en
el sistema y abra la Ilave de descompresiGn que se
encuentra en el fondo del tanque para drenar (Vea B
y D) en las p41ginas 13, 14 y 15.
NOTA: En climas frios, drene el tanque despues de cada
uso a fin de reducir los problemas por el congelamiento del
agua de condensaciGn.
REVISION DE LA VALVULA DE ALIVIO
Tire de la valvula de alivio todos los dias para asegurarse
de que este operando correctamente y para eliminar cualquier
obstruccion posible de la misma.
DETECCION DE FUGAS
Compruebe que todas las conexiones esten ajustadas.
Una pequefia fuga en cualquiera de las mangueras, o tuberia
reducir& de manera substancial el rendimiento de su
compresor de aire. Si sospecha la existencia de una fuga,
rocie una pequeSa cantidad de agua jabonosa alrededor de la
zona con una botella rociadora. Si aparecen burbujas, selle y
ajuste nuevamente la conexion. No ajuste demasiado.
ALMACENAMIENTO
Antes de almacenar el compresor durante periodos
prolongados, use un soplete de aire para limpiar todo el polvo
y suciedad del compresor. Desconecte el cordon electrico,
enroll41ndolo. Tire de la v411vula de alivio de la presiGn para
liberar toda la presiGn del tanque. Elimine toda la humedad del
tanque. Cubra toda la unidad para protegerla de la humedad y
del polvo.
16 200-2449
SERVICE INTERVAL J
Perform the following maintenance at the intervals indicated below.
Operate the pressure relief valve ......................................... Daily
Drain tank ............................................................ Daily
ENTRETIEN PI_RIODIQUE J
Effectuez I'entretien suivant aux intervalles indiques ci-dessous.
Faites fonctionner les
-soupapes de d_charge .......................................... Chaque jour
Vidangez le r_servoir ............................................ Chaque jour
INTERVALOS DE SERVICO J
Realice el mantenimiento siguiente a los intervalos indicados a continuaci6n.
Operaci6n de todas las v&lvulas
de alivio de la presi6n ............................................... A diario
Drenaje del tanque .................................................. A diario
200-2449 17
TROUBLESHOOTING CHART
Note: Troubleshooting problems may have similar causes and solutions.
I
PROBLEM
Low pressure or not
enough air
or
Compressor does not
stop
Excessive starting and
stopping, while not in use
POSSIBLE CAUSE
Tank petcock is open
Prolonged excessive use of air
Compressor not large enough
Restricted check valve
Hole in air hose
Tank leaks
Blown seals
Valve leaks
Fittings leak
Air leaks from regulator, Dirty or damaged regulator
or regulator does not internal parts.
regulate pressure
Regulated pressure This is normal If pressure drops too low, adjust regulator while accessory is used.
reading drops when air Compressor not large enough Check air requirement of accessory. If it is higher than CFM and
accessory is being used )ressure supplied by compressor, you need a larger compressor.
Most accessories are rated at 25% of actual CFM while running
continuously.
Circuit breaker trips (fuse Low voltage Furnish adequate power. If using extension cord, try without.
blows) too often Excessive wire length Consult electrician.
Restricted air passages Contact authorized service center.
Overheating Poor ventilation Relocate compressor to an area with cool, dry and well-circulated
air.
Clean all cooling surfaces of pump and motor thoroughly.
Replace worn parts and reassemble with new seals.
Motor stalls Furnish adequate power.
Pressure relief valve Contact authorized service center.
opens
Motor will not run
Dirty cooling surfaces
Leaking valve
Low voltage
Tank pressure exceeded normal
operating pressure
Control board failure
Tank pressure exceeds preset
_ressure switch limit
Motor overload protection has
tripped
Fuse blown or circuit breaker
tripped
SOLUTION
Close petcock
Decrease amount of air used.
Check air requirement of accessory. If it is higher than CFM and
)ressure supplied by compressor, you need a larger compressor.
Most accessories are rated at 25% of actual CFM while running
continuously.
Remove and clean or replace.
Check and replace if necessary.
_k LvAvg-'1=_l_ll_[=']mlmmediately replace tank. DO NOT attempt to repair.
Replace any faulty seals.
Replace worn parts and reassemble with new seals.
Check fittings with soapy water. Tighten or reseal leaking fittings.
DO NOT OVERTIGHTEN.
Replace worn parts and reassemble with new seals.
Replace any faulty seals.
Replace regulator or internal parts.
Contact authorized service center.
Motor will start automatically when tank pressure drops below
kick-in pressure of pressure tank.
Let motor cool off and overload switch will automatically reset. This
may take several minutes.
Replace blown fuse or reset circuit breaker. Do not use fuse or
circuit breaker with higher rating than specified for your branch
circuit.
Check for proper fuse; "Fusetron" type T is acceptable.
Check for low voltage and proper extension cord size.
Disconnect other applications from circuit. Operate compressor
on a dedicated circuit.
Remove and clean or replace.
Check for proper gauge and extension cord length.
Check valve stuck open
Wrong wire gauge in extension
cord
Loose electrical connections Contact authorized service center,
Paint spray on internal motor Have checked at service center. Do not operate compressor in the
_arts paint spray area
Possible defective motor Have checked at service center.
18 200-2449
CFM
Cubicfeetperminute;aunitofmeasureofairflow.
PSI
Poundspersquareinch;aunitofmeasureofairpressure.
Kick-inpressure
Factorysetlowpressurepointthatstartsthecompressorto
repressurizethetanktoahigherpressure.
Kick-outpressure
Factorysethighpressurepointthatstopsthecompressorfrom
increasingthepressureinthetankaboveacertainlevel.
Well-ventilated
Ameansofprovidingfreshairinexchangefordangerous
exhaustorvapors.
Dedicatedcircuit
Anelectricalcircuitreservedfortheexclusiveuseoftheair
compressor.
GLOSSARY OF TERMS 1
ASME
American Society of Mechanical Engineers.
Indicates that the components are manufactured, tested and
inspected to the specifications set by ASME.
CSA
Canadian Standards Association
Indicates that the products that have this marking have been
manufactured, tested and inspected to standards that are set
by CSA.
Standards Association (USA)
Indicates that the products that have this marking have been
manufactured, tested and inspected to standards that are set
by CSA. These products also conform to U.L standard 1450.
CFM
Pieds cubes par minute ; une unite de mesure de debit d'air.
Bar
Unite de mesure de pression d'air.
Pression d'ouverture
Point de pression bas regl6 en usine qui met en marche le
moteur de la pompe pour remettre sous pression I'air dans le
reservoir.
Pression d'arr6t
Point de pression haut r6gle en usine qui arr6te le moteur de
la pompe et la hausse de pression dans le reservoir au-dela
d'un certain niveau.
Bien a_r6
Qualifie un endroit oQ les gaz d'echappement ou les vapeurs
sont remplaces par de I'air frais.
Circuit r_serv6
Circuit electrique reserv6 exclusivement au compresseur d'air.
GLOSSAIRE DES TERMES J
ASME
American Society of Mechanical Engineers (Societ6
americaine des ingenieurs mecaniciens)
Indique que les composants sont fabriques, testes et
examines selon les normes definies par I'ASME.
CSA
L'association canadienne de normes
Indique que les produits qui font avoir examinee cette
inscription avoir et6 fabriquee, testee et aux normes qui sont
fixees par CSA.
canadienne de normes (Etats-Unis)
Indique que les produits qui font avoir fabrique cette
inscription, teste et examine aux normes qui sont fixees par
CSA. Ces produits se conforment egalement & la norme 1450
d'cU.l..
GLOSARIO DE TERMINOS ]
I/min
Litros por minuto; una unidad de la medida de flujo de aire.
Bar
Es una unidad de medida de la presi6n del aire.
Presi6n de conexi6n
Punto de presion baja fijado en f&brica que arranca el motor
de la bomba para volver a presurizar el tanque de aire a una
presi6n m&s elevada.
Presi6n de desconexi6n
Punto de presion alta fijado en fabrica que impide que el
motor de la bomba aumente la presi6n en el tanque por
encima de un cierto nivel.
Bien ventilado
Un medio de proveer aire fresco para contrarrestar el escape
de gases o los vapores peligrosos.
Circuito dedicado
Un circuito electrico reservado para uso exclusivo del
compresor de aire.
ASME
American Society of Industrial Engineers.
Indica que los componentes se fabricaron, probaron y
examinaron de acuerdo con las especificaciones establecidas
por ASME
CSA
La asociaci6n canadiense de los est_ndares
Indica que los productos que hacen esta marca haber sido
fabricados, haber sido probados y haber examinado a los
estandares que son fijados por CSA.
asociaci6n canadiense de los est_ndares (los
E.E.U.U.)
Indica que los productos que hacen esta marca haber
fabricado, probado y examinado a los est&ndares que son
fijados por CSA. Estos productos tambien se conforman con
el estandar 1450 de U.L.
22 200-2449
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22

Kobalt (Coleman) 215914 Owner's manual

Category
Air compressors
Type
Owner's manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI