  • Hello! I've reviewed the installation instructions for SBI mantel shelves AC02780, AC02781, AC02782, and AC02783. This document provides details on safely installing these non-combustible shelves, including weight limits, mounting techniques, and safety warnings. I'm ready to answer your questions and help you understand how to install and use your new mantel.
  • What is the maximum load for a 60 inch mantel?
    What type of wall studs are suitable for mounting?
    What is the maximum load for a 72 inch mantel?
Printed in Canada
Non-Combustible Mantel Shelve
AC02780, AC02781, AC02782, AC02783
2023-04-28
Installation
Instructions
3
1. Kit Contents
Mantel (1x)
Mounting Bracket 3"x 2" (1x)
Self-drilling screws for Mantel 2 ¼" (3x)
Sharp point screws for mounting bracket 2 ½" (8x)
2. What You Will Need (not included)
Powered Driver Phillips head drive Tape Measure
Level Stud Locator
3. Installation Safety Warnings
Read all instructions before mounting or using the mantel.
Use the mantel only for its intended use as described in these instructions.
DO NOT OVERLOAD MANTEL: The maximum load for all 60 inch mantels is 150lbs. The
maximum load for all 72 inch mantels is 180lbs.
Mantel “supercast” material meets non combustibility standards in accordance with ASTM
E136.
WARNING: Combustible objects placed on or around the mantel must meet your fireplace
manufacturer’s requirements for clearances to combustibles.
IMPORTANT: The fasteners supplied with this furnishing are intended for use in standard
wood stud walls or 16 gauge metal stud walls only. Minimum wall stud size required is 2”x
4”, with drywall or finished wall surface ranging from ½” to ¾” thick. For all other mounting
surfaces, use appropriate fasteners as specified by local building codes or other jurisdiction.
For mounting to other wall types; if you are at all unsure of the correct fastening method,
4
contact your local building official. Improper mounting may lead to property damage, injury,
or death.
Be sure to follow your fireplace manufacturer’s clearances to non-combustibles or local
code if applicable when determining a location for your mantel. Combustibles set on a non-
combustible mantle must meet clearance requirements for combustibles.
IMPORTANT: If you are at all unsure of the correct fastening method, contact your local
building official. Improper mounting may lead to property damage, injury, or death.
4. Installation Notes
Recommended two people to lift and install mantel.
If you are unable to find studs, you need to open the wall and add wood studs or 16 gauge
metal studs if in the non-combustible zone.
A minimum of 3 studs are required to safely install a 5 ft. mantel. Minimum of 4 studs for 6 ft.
mantels. Using 2 1/2” sharp point screws, attach mounting bracket to studs with two screws
per stud. See Figure 1 on page 5 for details.
If attaching mounting bracket over a masonry surface use proper masonry anchor for the
type of surface – consult your fastener supplier. The anchor should be able to support 4
times the load.
5
5. Installation Instructions
Step 1. Unpack mantel from box. Remove protective foam. Note: the top flange of mantel has pre-
drilled mounting holes.
Step 2. Locate mounting bracket and hardware inside of box.
Step 3. Determine the vertical and horizontal center for top of mantel on the wall. Mark this location.
Step 4. After identifying the correct height for attaching the mantel, draw a horizontal line. Install
centered mounting bracket (with the 2" side on the wall) with 2 sharp point screws per stud.
Use 1/8” drill bit to drill holes in the mounting bracket. You will need two people to place the
mantel on the bracket and check for level, take the mantel off and stabilize the mounting
bracket with remaining screws. See Figure 2.
Step 5. With two people, lift mantel and place over mounting bracket. When centered and flush
against the wall, place one 2 1/4” self-drilling screw in the center pre-drilled hole on top of
mantel. Screw through mounting angle until fastener head is flush with countersunk hole.
See Figure 3
Step 6. Shims may be required to level mantel. Install non-combustible shims over the studs. If
required, fill screw holes on top surface of mantel with the provided filler.
DO NOT OVER-TIGHTEN.
Fasten screws through the provided holes on top of mantel.
DO NOT SCREW THROUGH THE BOTTOM OF THE MANTEL
6
C U S T O M E R S U P P O R T
If y o u h a v e a n y q u e s t i o ns, c o ntact u s a t
8 7 7 . 336.8836 i n f o @ l e x i n g t o n h e a r t h . c o m
I N S T A L L A TIO N
DIAGRA M S
L
E
X
I
N
G
T
O
N
H
E
A
R
T
H
S T U D
FRONT MOUNT FIG . A
S I DE MOUNT F I G . B
2 1/2” SHAR P
POINT SCR E W
M A NTE L
BRACK E T
11. 5 ”
STUD P ENE T R A T I O N
2 . 5
S E L F -DRILLIN G
SCRE W
MANT E L
BRACKE T
MANTE L
(WITH THE 2" SIDE
ON THE WALL)
(WITH THE 2" SIDE
ON THE WALL)
Figure 1: Front Mount
C U S T O M E R S U P P O R T
If y o u h a v e a n y q u e s t i o ns, c o ntact u s a t
8 7 7 . 336.8836 i n f o @ l e x i n g t o n h e a r t h . c o m
I N S T A L L A TIO N
DIAGRA M S
L
E
X
I
N
G
T
O
N
H
E
A
R
T
H
S T U D
FRONT MOUNT FIG . AS I DE MOUNT F I G . B
2 1/2” SHAR P
POINT SCR E W
M A NTE L
BRACK E T
11. 5 ”
STUD P ENE T R A T I O N
2 . 5
S E L F -DRILLIN G
SCRE W
MANT E L
BRACKE T
MANTE L
(WITH THE 2" SIDE
ON THE WALL)
(WITH THE 2" SIDE
ON THE WALL)
C U S T O M E R S U P P O R T
If y o u h a v e a n y q u e s t i o ns, c o ntact u s a t
8 7 7 . 336.8836 i n f o @ l e x i n g t o n h e a r t h . c o m
I N S T A L L A TIO N
DIAGRA M S
L
E
X
I
N
G
T
O
N
H
E
A
R
T
H
S T U D
FRONT MOUNT FIG . AS I DE MOUNT F I G . B
2 1/2” SHAR P
POINT SCR E W
M A NTE L
BRACK E T
11. 5 ”
STUD P ENE T R A T I O N
2 . 5
S E L F -DRILLIN G
SCRE W
MANT E L
BRACKE T
MANTE L
(WITH THE 2" SIDE
ON THE WALL)
(WITH THE 2" SIDE
ON THE WALL)
Figure 2: Side Mount Figure 3: Side Mount with Mantel
ONE YEAR WARRANTY
SBI Heating accessories warrants for the purchaser’s first year of ownership that our non
combustible mantle, when reasonably maintained and used, shall be free from any defects
in material; or manufacturer’s workmanship. Proof of purchase will be required, so keep your
receipt. A Return Authorization Number is needed to return goods prepaid to our facility, at 250
rue de Copenhague Saint-Augustin-de-Desmaures, Québec, Canada, G3A 2H3. SBIHA shall
not be liable for any consequential or identical damages resulting in loss from the use of this
product.In no case will SBIHAs liability exceed the customer’s purchase cost.
SBI HEATING ACCESSORIES
25 De Copenhague Street
Saint-Augustin-de-Desmaures
Québec, Canada
G3A 2H3
1-877-356-6663
Thank you for purchasing an SBI
Heating accessory!
/