Watercop WCECP Series Installation guide

  • Hello! I've reviewed the WaterCop Classic PVC Valve user guide and am ready to assist you with any questions you might have. This document covers the installation of the valve, wiring of the industrial actuator, and mounting of the interface, as well as important safety instructions. Feel free to ask me anything related to the valve installation process.
  • What type of actuator is used with the PVC valve?
    What should I do before wiring the actuator?
    Where is the WCDNM interface mounted?
    What should you keep away from the valve when testing?
A PVCapplication (1 ½” or 2”) is much the same as those less than 1 ½”, but it incorporates an
industrial actuator required to control all sizes of the PVC valves.
1) Remove the WCECP Series industrial actuator from the box so you can wire it to the WCDNM.
2) Loosen the small Allen-head screw in the side of the indicator arrow then gently pry off the
indicator arrow with a screwdriver.
3) Remove the four Allen-head bolts and take off the top cover to expose the wiring terminals. Save
the gasket for step 6. (Reference Image # 1)
4) Guide the leads from the WCDNM through the conduit connection in the industrial actuator and
tighten the strain relief for the cord. (Reference Image # 2)
5) Attach the three leads from the WCDNM to the industrial actuator as shown. (Reference Image #
3)
6) Replace the gasket, cover and indicator arrow; making sure the arrow and valve position coincide.
(Reference Image # 4)
7) You are now ready to test the system. Please refer to the WaterCop Classic Owner’s Manual.
WARNING! The valve closes with great force and could cut off a finger. Keep fingers and
other objects out of the valve when testing.
8) After successful testing, you’re ready to install the valve/ industrial actuator, and interface.
9) The WCDNM interface is mounted indoors near the industrial actuator using mounting holes inside
the case of the WCDNM. (Reference Image #5)
10) Please refer to the ‘Valve Installation’ section of the WaterCop Classic Owner’s Manual to install the
valve; double-check that the indicator arrow and valve position coincide.
11) Now you’re ready to install the Leak Sensors. The sensors install and operate as usual. Refer to the
‘Installation of Leak Sensor’ section of the WaterCop Classic Owner’s Manual.
WCDNM WIRING GUIDE
* Use 12 VDC actuator only
Example 1" valve/actuator part #: WCECP25Z5E22H
LEAD COLOR TERMINAL #
BLACK 1
RED 2
WHITE 3
WaterCop Classic PVC Valve Installation Guide
The Proven Leader in Leak Detection & Automatic Water Shut-Off: WaterCop is there when you’re not.
Image # 1
Image # 2
Image # 3
Image # 4
Image # 5
WaterCop Classic PVC Valve Installation Images
WaterCop by DynaQuip | 10 Harris Industrial Park | St. Clair, MO 63077 | dealership@watercop.com | (800) 545-3636
/