IMPORTANT INSTRUCTIONS • SAVE THESE INSTRUCTIONS
Model PE653RC
• Service mode should not be used for servicing the pump or other pool equipment.
• Disconnect power at the circuit breaker(s) or disconnect switch(es) before installing or servicing pool equipment.
WARNING Risk of Fire or Electric Shock
INTERMATIC INCORPORATED
SPRING GROVE, ILLINOIS 60081-9698
http://www.intermatic.com
Service Mode allows you to manually turn the lter pump ON or OFF, without the use of a controller, by
pushing the appropriate buttons on the PE653 receiver. When turning a pump ON, a countdown period
of 1,2,3,4 or 5 hours is set that will override the schedule, ensuring proper mixing of chemicals. At the
end of the user-dened period, the PE653 will turn the pump OFF and resume the normal programmed
schedule.
To Activate Service Mode:
Press and hold button #1 on the PE653 receiver until the indicator light starts blinking for Circuit 1.
Then, press button 1, 2, 3, 4, or 5 to set the duration, in hours, you want the pump to be ON. The
Circuit 1 light will continue to blink for the duration of the service mode.
To Deactivate Service Mode:
Press and hold button #1 on the PE653 receiver until the indicator light stops blinking (approx. 5
seconds).
MultiWave™ Wireless Pool and Spa Control System
Service Mode Instructions
http://waterheatertimer.org/Digital-control-centers-and-manuals.html#PE653RC