OM-181 408 Page 3
7. Moving Jumper Plug To Match Wire Feeder To Welding Power Source
ST-801 594
Y Turn off welding power
source and wire feeder. Un-
plug unit from feeder and
power source.
The ATC-24 is factory set to use a
standard PD22, PD22P12, or PD60
wire feeder with an older model
400SM or 630SMP with a 17-pin re-
ceptacle. If a remote voltage control
option is used on the wire feeder or
if a 400SMT with a 17-pin recep-
tacle is used, then move the jumper
plug as follows:
Remove wrapper from unit.
Find connector and the three free-
hanging jumper plugs in the wiring
harness.
For 17-pin Model 400SM or
630SMP used with a PD22,
PD22P12, or PD60 with optional re-
mote voltage control:
1 Disconnect jumper plug
labeled “400SM w/front panel
control” from the receptacle.
2 Connect jumper plug labeled
“400SM w/remote control” to
receptacle.
3 Reinstall wrapper.
For 17-pin Model 400SMT used
with a PD22, PD22P12, or PD60
with or without optional remote
voltage control:
1 Disconnect jumper plug la-
beled “400SM w/front panel
control” from the receptacle.
2 Connect jumper plug labeled
“400SMT” to receptacle.
3 Reinstall wrapper.
Resume operation. For use with
competitive welding power
sources, call PowCon Technical
Service.
1
2
3
4
5
6
7
8
73
84
6
5
2
1
3 7
4 8
2
1
6
5
RC2A
RC2B
RC2C
400 SM
W/FRONT
PANEL CONTROL
400 SMT
CONTROL
W/REMOTE
400 SM
8. Troubleshooting
Trouble Remedy
No weld output. Be sure welding power source Power switch is On.
Check cord connections or replace cords, if necessary.
Reset circuit breaker CB1 (see Section 3).
Check welding gun and/or wire feeder.
Check position of jumper plug (see Section 7).