Generac 48kW RD04834ADAS User manual

  • Hello! I am an AI chatbot trained to assist you with the Generac 48kW RD04834ADAS User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • Where can I find the fuel level gauge and sender?
    Where is the oil drain hose located?
    Which side is the air cleaner element located?
    Is there more than one way to access the radiator fill cap?
    Where are the lifting provisions?
    What are the dimensions of the removable stub-up cover?
    Where is the fuel supply located?
    What is the usable capacity of the fuel tank?
4 3 2 1
4 3 1
A
B
A
B
892 [35.1]
CENTER OF GRAVITY
SEE NOTE 5
146 [5.7]
EXHAUST OUTLET
173 [6.8]
897 [35.3]
DOOR WIDTH
TYP
1414.4 [55.7]
OVERALL
HEIGHT
888.1 [35.0]
OVERALL WIDTH
301.9 [11.9]
TYP
1322 [52.0]
TYP
1953.8 [76.9]
OVERALL LENGTH
182.4 [7.2]
TYP
WEIGHT DATA WITH EMPTY BASETANK
(SEE NOTE 5)
GENERATOR AS SHOWN
886 [1953]
WITH WOODEN SHIPPING SKID
925 [2039]
SERVICE ITEM 3.4L
OIL FILL CAP RIGHT SIDE
OIL DIP STICK RIGHT SIDE
OIL FILTER RIGHT SIDE
OIL DRAIN HOSE RIGHT SIDE
RADIATOR DRAIN HOSE LEFT SIDE
AIR CLEANER ELEMENT RIGHT SIDE
MUFFLER FRONT
FAN BELT EITHER SIDE
BATTERY LEFT SIDE
TITLE
INSTALL PROTECTOR D3.4L G16 SW
ISSUE DATE: 08/2018
SIZE CAGE NO DWG NO
10000042752
REV
B
N/A
A
SCALE
0.050
WT-KG SEE ABOVE SHEET
1 of 2
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
SH
1/2
REV
A
WINDCHILL VERSION
A.1
NOTES:
1. MINIMUM RECOMMENDED CONCRETE PAD SIZE: 1194 (47") WIDE X 2718
(107") LONG. REFERENCE INSTALLATION GUIDE SUPPLIED WITH UNIT
FOR CONCRETE PAD GUIDELINES
2. ALLOW SUFFICIENT ROOM ON ALL SIDES OF THE GENERATOR FOR MAINTENANCE
AND SERVICING. THIS UNIT MUST BE INSTALLED IN ACCORDANCE WITH CURRENT
APPLICABLE NFPA 37 AND NFPA 70 STANDARDS AS WELL AS ANY OTHER FEDERAL,
STATE AND LOCAL CODES.
3. CONTROL PANEL / CIRCUIT BREAKER INFORMATION:
- SEE SPECIFICATION SHEET OR OWNERS MANUAL
- ACCESSIBLE THROUGH CUSTOMER ACCESS ASSEMBLY DOOR ON REAR OF
GENERATOR
4. REMOVE THE REAR TANK AND REAR ENCLOSURE COVER PANEL TO ACCESS
THE STUB-UP AREAS AS FOLLOWS:
- HIGH VOLTAGE CONNECTION INCLUDING AC LOAD LEAD CONDUIT CONNECTION,
NEUTRAL CONNECTION, BATTERY CHARGER 120 VOLT AC (0.5 AMP MAX) CONNECTION.
- LOW VOLTAGE CONNECTIONS INCLUDING TRANSFER SWITCH CONTROL WIRES
5. CENTER OF GRAVITY AND WEIGHT MAY CHANGE DUE TO UNIT OPTIONS.
6. ENGINE SERVICE CONNECTIONS
OIL DRAIN: 3/8" NPT
EXHAUST OUTLET: 2" O.D.
7. BOTTOM OF GENERATOR SET MUST BE ENCLOSED TO PREVENT PEST INTRUSION AND
RECIRCULATION OF DISCHARGE AIR AND/OR IMPROPER COOLING AIR FLOW.
8. REFERENCE OWNERS MANUAL FOR LIFTING WARNINGS.
9. MOUNTING BOLTS OR STUDS TO CONCRETE PAD SHALL BE 5/8-11 GRADE 5
(USE STANDARD SAE TORQUE SPECS)
REFERENCE OWNERS MANUAL FOR PERIODIC
REPLACEMENT PART LISTINGS.
WEIGHT: KG [LBS]
DIMENSIONS: MM [INCH]
CIRCUIT BREAKER
SEE NOTE 3
REAR VIEW
REAR ENCLOSURE
COVER PANEL
SEE NOTE 4
CUSTOMER ACCESS
ASSEMBLY, CONTROL
PANEL ACCESS AND
BATTERY CHARGER
LOCATED WITHIN
SEE NOTE 4
REMOVABLE
STUB-UP COVER
SEE NOTE 4
RIGHT SIDE VIEW
VISE ACTION LATCH, ONE PER
DOOR AND ONE LIFT-OFF DOOR
PER SIDE OF THE GENERATOR
LIFTING PROVISIONS SEE
NOTE 5, 8 AND CENTER
OF GRAVITY DIMENSION
(4 PLACES)
LEFT SIDE VIEW
RADIATOR/EXHAUST
DISCHARGE AIR
GENERATOR ENCLOSURE
ENCLOSED WITHIN
EXHAUST MUFFLER
VENTILATION
CROSS-FLOW OF AIR
PROVIDE ADEQUATE
VENTILATION DUCT TO
OF FUEL TANK
TYPICAL ON BOTH SIDES
OPEN PUNCHED LOUVERS,
TOP VIEW
BATTERY 12 VOLT
NEGATIVE GROUND
AIR INTAKE
(BOTH SIDES)
REMOVE COVER
FOR ACCESS TO
RADIATOR FILL CAP
RADIATOR/EXHAUST
DISCHARGE AIR
(BOTH SIDES)
4 3 2 1
4 3 1
A
B
A
B
888.1 [35.0]
851.1 [33.5]
MOUNTING CENTERS
TYP
SEE NOTE 9
352.9 [13.9]
111.9 [4.4]
TYP
711.9 [28.0]
TYP
1241.9 [48.9]
TYP
1841.9 [72.5]
TYP
1953.8 [76.9]
267.1 [10.5]
TYP
181.1 [7.1]
TYP
757.1 [29.8]
TYP
842.3 [33.2]
923.2 [36.3]
1043.6 [41.1]
1194.2 [47.0]
1431.1[56.3]
1553.5 [61.2]
786 [30.9]
51.1 [2.0]
125 [4.9]
*STUB-UP
AREA
38 [1.5]
125 [4.9]
*STUB-UP
AREA
253.3 [10.0]
62.4 [2.5]
1687.6 [66.4]
18.5 [.7]
TYP
250.2 [9.9]
FUEL TANK
HEIGHT
850.1 [33.5]
DRAWING CREATED FROM PRO/ENGINEER
3D FILE. ECO MODIFICATION TO BE
APPLIED TO SOLID MODEL ONLY.
TITLE
INSTALL PROTECTOR D3.4L G16 SW
ISSUE DATE: 08/2018
SIZE CAGE NO DWG NO
10000042752
REV
B
N/A
A
SCALE
0.050
WT-KG SEE ABOVE SHEET
2 of 2
GENERAC POWER SYSTEMS OWNS THE COPYRIGHT OF THIS DRAWING
WHICH IS SUPPLIED IN CONFIDENCE AND MUST NOT BE USED FOR
ANY PURPOSE OTHER THAN FOR WHICH IT IS SUPPLIED WITHOUT
THE EXPRESS WRITTEN CONSENT OF GENERAC POWER SYSTEMS.
c GENERAC POWER SYSTEMS 2013
ELECTRONICALLY APPROVED
INSIDE WINDCHILL
SH
2/2
REV
A
WINDCHILL VERSION
A.1
FUEL TANK
TOTAL CAPACITY 253.6 [67]
USABLE CAPACITY 230.9 [61]
*NOTE: STUB-UP AREA FOR HIGH AND LOW
VOLTAGE CONNECTIONS, CIRCUIT BREAKER,
NEUTRAL AND CUSTOMER CONNECTION OPENING.
CAPACITY: LITER [GALLONS]
DIMENSIONS: MM [INCH]
16.7 [.66] MOUNTING HOLES
(8 PLACES)
SEE NOTE 9
REMOVABLE
STUB-UP COVER
SEE NOTE 4
REAR VIEW
REMOVABLE COVER
LEFT SIDE VIEW
FUEL RETURN
FUEL SUPPLY
FUEL FILL
(2" NPT FEMALE)
FUEL LEVEL
GAUGE/SENDER
NORMAL VENT
(2" NPT FEMALE)
EMERGENCY VENT
(2" NPT FEMALE)
HIGH AND LOW
VOLTAGE STUB-UP
TOP VIEW
/