Bunn LCR-3 HV User manual

Category
Coffee makers
Type
User manual

This manual is also suitable for

LCR-3 HV
INSTALLATION & OPERATING GUIDE
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
To ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts
Catalog, Programming Manual, or Service Manual, please visit the Bunn-O-Matic website, at
www.bunn.com. This is absolutely FREE, and the quickest way to obtain the latest catalog and
manual updates. For Technical Service, contact Bunn-O-Matic Corporation at 1-800-286-6070.
41129.0000H 06/11 ©2008 Bunn-O-Matic Corporation
2
41129 050511
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY
Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows:
1) All equipment other than as specified below: 2 years parts and 1 year labor.
2) Electronic circuit and/or control boards: parts and labor for 3 years.
3) Compressors on refrigeration equipment: 5 years parts and 1 year labor.
4) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis:
parts and labor for 3 years or 30,000 pounds of coffee, whichever comes first.
These warranty periods run from the date of installation BUNN warrants that the equipment manufactured by
it will be commercially free of defects in material and workmanship existing at the time of manufacture and
appearing within the applicable warranty period. This warranty does not apply to any equipment, component or
part that was not manufactured by BUNN or that, in BUNN’s judgment, has been affected by misuse, neglect,
alteration, improper installation or operation, improper maintenance or repair, damage or casualty. This warranty is
conditioned on the Buyer 1) giving BUNN prompt notice of any claim to be made under this warranty by telephone
at (217) 529-6601 or by writing to Post Office Box 3227, Springfield, Illinois 62708-3227; 2) if requested by
BUNN, shipping the defective equipment prepaid to an authorized BUNN service location; and 3) receiving prior
authorization from BUNN that the defective equipment is under warranty.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY, WRITTEN OR
ORAL, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF EITHER
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. The agents, dealers or employees of BUNN
are not authorized to make modifications to this warranty or to make additional warranties that are binding on
BUNN. Accordingly, statements by such individuals, whether oral or written, do not constitute warranties and
should not be relied upon.
If BUNN determines in its sole discretion that the equipment does not conform to the warranty, BUNN, at its
exclusive option while the equipment is under warranty, shall either 1) provide at no charge replacement parts
and/or labor (during the applicable parts and labor warranty periods specified above) to repair the defective
components, provided that this repair is done by a BUNN Authorized Service Representative; or 2) shall replace
the equipment or refund the purchase price for the equipment.
THE BUYER’S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE OF
THIS EQUIPMENT, WHETHER DERIVED FROM WARRANTY OR OTHERWISE, SHALL BE LIMITED, AT BUNN’S
SOLE OPTION AS SPECIFIED HEREIN, TO REPAIR, REPLACEMENT OR REFUND.
In no event shall BUNN be liable for any other damage or loss, including, but not limited to, lost profits, lost sales,
loss of use of equipment, claims of Buyer’s customers, cost of capital, cost of down time, cost of substitute
equipment, facilities or services, or any other special, incidental or consequential damages.
392, AutoPOD, AXIOM, BrewLOGIC, BrewMETER, Brew Better Not Bitter, BrewWISE, BrewWIZARD, BUNN Espress, BUNN
Family Gourmet, BUNN Gourmet, BUNN Pour-O-Matic, BUNN, BUNN with the stylized red line, BUNNlink, Bunn-OMatic,
Bunn-O-Matic, BUNNserve, BUNNSERVE with the stylized wrench design, Cool Froth, DBC, Dr. Brew stylized Dr. design,
Dual, Easy Pour, EasyClear, EasyGard, FlavorGard, Gourmet Ice, Gourmet Juice, High Intensity, iMIX, Infusion Series,
Intellisteam, My Café, PowerLogic, Quality Beverage Equipment Worldwide, Respect Earth, Respect Earth with the styl-
ized leaf and coffee cherry design, Safety-Fresh, savemycoffee.com, Scale-Pro, Silver Series, Single, Smart Funnel, Smart
Hopper, SmartWAVE, Soft Heat, SplashGard, The Mark of Quality in Beverage Equipment Worldwide, ThermoFresh, Titan,
A Partner You Can Count On, Air Brew, Air Infusion, Beverage Bar Creator, Beverage Profit Calculator, Brew better, not
bitter., BUNNSource, Coffee At Its Best, Cyclonic Heating System, Digital Brewer Control, Nothing Brews Like a BUNN,
Pouring Profits, Signature Series, Tea At Its Best, Phase Brew, The Horizontal Red Line, trifecta, Ultra, Velocity Brew are
either trademarks or registered trademarks of Bunn-O-Matic Corporation.
3
INTRODUCTION
Always follow the Concentrate Manufacturer’s for recommendations for proper Storage and Shelf Life. The
product Flavor Profile is extended by the refrigerated cabinet featured in the LCR-3. This dispenser is designed
to operate at ambient temperatures from 32°F (0°C) minimum to 104°F (40°C) maximum.
41129 060111
Warranty .......................................................................... 2
Introduction ..................................................................... 3
User Notices .................................................................... 4
Electrical Requirements ................................................... 5
Plumbing Requirements .................................................. 5
Initial Set-up .................................................................... 6
Electrical Hook-up ............................................................ 6
Plumbing Hook-up ........................................................... 6
Leveling the Dispenser ..................................................... 6
Installing Pump Tubing .................................................... 7
Operating Controls & Interface ........................................ 8
Initial Fill & Heat ............................................................... 9
Rinse Alarm Feature ....................................................... 10
BIB Empty Lockout Feature ............................................ 11
Brew Temperature Lockout Feature ................................ 11
Energy Saver Mode ........................................................ 11
Optional 2-Product Operation ........................................ 11
Programming the Dispenser .......................................... 12
Loading the Concentrate ................................................ 17
Priming the Concentrate Lines ....................................... 17
Operating the Dispenser ................................................. 18
Filling Cambros or other large containers ...................... 18
Cleaning & Preventive Maintenance ............................... 19
Replacing the Pump Tubing ........................................... 20
Draining the Hot Water................................................... 21
Troubleshooting ............................................................. 22
Field Calibration of the Concentrate Pumps ................... 25
Dispenser Flow Rate Calibration .................................... 25
Field Calibrating the Empty BIB Warning ........................ 26
Schematic Wiring Diagram ............................................ 27
CONTENTS
4
Optional Field Wiring
120/208 V, 37.6 A, 7820 W
1PH, 3-Wire + GND, 60HZ
120/240 V, 43.2 A, 10400 W
1PH, 3-Wire + GND, 60HZ
FOR USE ON INDIVIDUAL BRANCH CIRCUIT ONLY
120/208Y V, 32.8 A, 12000 W
3PH, 4-Wire + GND, 60HZ
28181.0004
37947.0002
USER NOTICES
Carefully read and follow all notices on the equipment and in this manual. They were written for your protec-
tion. All notices are to be kept in good condition. Replace any unreadable or damaged labels.
00656.0001
00986.0002
37280.0000
37881.0000
CHARGE
Type R134A, Amount 13 oz (368.6 gm)
Design Pressures:
High 276 psi (19 bar) (1.9 MPa)
Low 88 psi (6 bar) (0.61 MPa)
33461.0004
27508.0000
To reduce the risk of electric shock,
do not remove or open cover.
No user-serviceable parts inside.
Authorized service personnel only.
Disconnect power before servicing.
Moving Parts.
Do not operate
unit with this
panel removed.
Risk Of Electrical Shock.
Disconnect power before
servicing unit.
27442.0000
! CAUTION
Do not connect to a
circuit operating at
more than 150 volts
to ground.
WARNING: HOT LIQUIDS
41129 060111
L1 L2 L3 N
FOR 3-PHASE OPERATION
CONNECT INPUT WIRING TO
L1,L2,L3 & N AS SHOWN.
BLK
BLU
RED
WHI
TERMINAL
BLOCK
TO MACHINE
FROM POWER SOURCE
TO MACHINE
FROM POWER SOURCE
L1 L2 L3 N
BLK
RED
BLU
WHI
FOR SINGLE PHASE OPERATION
MOVE BLU WIRE INTO
TERMINAL BLOCK WITH BLACK
WIRE, CONNECT INPUT WIRING
TO L1, L2 & N AS SHOWN.
00824.0002
40054.0000
REMINDER!
CLEAN AIR FILTER
WEEKLY
(LOCATED UNDER THE DISPENSER)
RECORDATORIO!
LIMPIAR EL FILTRO DE
AIRE SEMANALMENTE
(LOCALIZADO DEBAJO
DEL DISPENSADOR)
AIR FILTER
CLEAN WEEKLY!
(LOCATED UNDER THE DISPENSER)
FILTRO DE AIRE
LIMPIAR
SEMANALMENTE!
(LOCALIZADO DEBAJO
DEL DISPENSADOR)
As directed in the International Plumbing Code of the
International Code Council and the Food Code
Manual of the Food and Drug Administration (FDA),
this equipment must be installed with adequate
backflow prevention to comply with federal, state
and local codes. For models installed outside the
U.S.A., you must comply with the applicable Plumb-
ing /Sanitation Code for your area.
Artwork for P/N: 00656.0001
Artwork Rev: A
Drawn: REF
Date: 04/22/10
5
ELECTRICAL REQUIREMENTS
CAUTION: The dispenser must remain disconnected from power source until specified in Electrical Hook-Up.
The LCR-3 HV is shipped configured for 3 Phase operation. The internal terminal block must be rewired for
208/240V – 1Phase applications, (see Optional Field Wiring Diagram).
FIELD WIRING TERMINAL BLOCK DIAGRAM
For all 208 - 240 Volt Connections: Use No. 6 AWG Wires suitable for 90°C (194 °F)
1. Unit is shipped wired for 3 Phase / 5 wire operation.
2. For 208 - 240V / 1 Phase / 3 Wire: Move the Blue Heater wire to the Top Black Terminal as shown.
3. Unit requires120 Vac from L1 to N.
L1 L2 L3 N
BLK
BLU
RED
WHI
TERMINAL
BLOCK
TO MACHINE
FROM POWER SOURCE
Fig 1 Fig 2
TO MACHINE
FROM POWER SOURCE
L1 L2 L3 N
BLK
RED
BLU
WHI
PLUMBING REQUIREMENTS
The dispenser may be connected to a cold or hot water system (140°F Max.) with operating pressure between
20 and 90 psi (138 and 620 kPa) from a 1/2” or larger supply line. Install a regulator in the line when pressure
is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The dispenser is set up to deliver to 6 Oz./sec.
(177.4 ml/sec) and requires a water supply that can deliver a minimum of 3 gpm (11.4 lpm) at the inlet valve. A
shut-off valve should be installed in the line before the dispenser.
NOTE: The water inlet fitting is 3/8” flare. Bunn-O-Matic recommends 3/8” flexible tubing from the 1/2” water
supply line. At least 18 inches of FDA approved beverage tubing, such as reinforced braided polyethylene or
silicone, before the dispenser will facilitate movement to clean the counter top. Bunn-O-Matic does not recommend
the use of a saddle valve to supply water to the dispenser. The size and shape of the hole made in the supply line
made by this type of device may restrict water flow.
NOTE: The water level sensors in this machine do not work with de-ionized water and may cause the unit to overflow.
RO (Reverse Osmosis) water supply systems may need to be treated to restore free ions to the water.
41129 060111
As directed in the International Plumbing Code of the International Code Council and the Food Code
Manual of the Food and Drug Administration (FDA), this equipment must be installed with adequate
backflow prevention to comply with federal, state and local codes. For models installed outside the
U.S.A., you must comply with the applicable Plumbing /Sanitation Code for your area.
ALTERNATE LOCATION FOR THE WATER AND ELECTRICAL CONNECTIONS
The LCR-3 HV is supplied with the electrical and water connections at the back of the dispenser. However, in
some applications it may be more convenient for one or both of these connections to be located in the bottom
of the dispenser. To change the location, remove appropriate cover plate(s) from the bottom of the dispenser.
Remove the valve and/or electrical clamp and holes plugs from the back of the dispenser and install them in
the bottom panel. Re-install the cover plate on the back of the dispenser to cover the open holes. Take care to
replace and tighten all water clamps, mounting screws and the plastic hole plugs.
6
ELECTRICAL HOOK-UP
CAUTION: Improper electrical installation will damage electronic components.
1. An electrician must provide electrical service as specified in conformance with all local, state and federal
electrical codes.
2. Using a voltmeter, check the voltage and color-coding of each conductor at the electrical source.
3. If plumbing is to be hooked up later, be sure the dispenser is disconnected from the power source. If plumbing
has been hooked up, the dispenser is ready for Initial Fill & Heat.
PLUMBING HOOK-UP
1. Flush the water line to remove any debris or foreign material.
2. Securely attach the water line to the 3/8” flare fitting, lower – right - rear corner of the dispenser.
3. Turn on the water supply and check for leaks.
1/16"
LEVEL
41129 060111
NOTE - Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed
and maintained in accordance with federal, state and local codes.
INITIAL SET-UP
NOTE: The LCR-3 HV dispenser weighs approximately 180 lbs. (82 kg). Use more than one person when lifting
or moving the dispenser.
1. Cut the straps and remove the box and foam packing.
2. Locate and remove the information packets and tube kits from top of packaging and set aside.
3. Set dispenser on the counter where it is to be used. CAUTION: DO NOT LIFT ON THE DOOR.
4. Confirm the dispenser is level on the counter (See LEVELING THE DISPENSER).
LEVELING THE DISPENSER
Proper leveling of the dispenser is required to insure proper drainage of condensation from the refrigeration unit.
1. Set the dispenser on a level counter top.
2. Use the (6) adjustable legs to level the dispenser.
3. Once the unit is level, adjust the front three legs out another 1/16” to create a slight tilt towards the rear of
the dispenser. (See Fig. below)
7
INSTALLING THE PUMP TUBING
(Refer to the Tubing Installation Instructions in side the cabinet door for details.)
1. Loosen the thumbscrew securing the tubing retainer plate to the pump housing. Set the retainer plate aside.
2. Depress the tension screw and remove it from the notch in the pump body, releasing the pump compression band.
3. Apply lubricant (BUNN-O-MATIC part number M2531.0001) to the new pump tubing.
4. Insert the tubing onto the mix chamber port and wrap the tubing around the pump rotor, making sure that the elbow and clamps
end up on the bottom side of the pump body.
5. Close the compression band reinsert the tension screw into the notch in the pump housing.
6. Replace the tubing retainer plate and tighten the thumbscrew.
7. Reconnect bag connector to the product box.
8. Repeat steps 1 through 7 for the other two pumps.
9. Prime the pumps. Refer to Priming the Concentrate Lines section.
Remove Retaining Plate Release Spring Tension Remove Tubing
Lubricate New Tube
Install New Tubing Completed Installation
Thumbscrew
Lubricate between arrows
2.0”
2.0”
Tension
Screw
Tube Clamp
Tension Screw
41129 110608
DRIP TRAY INSTALLATION
1. Unscrew the middle and right front legs (Fig. 1) - just enough to allow the mounting bracket to slide under the legs, (~1/8”).
Caution: The LCR-3 HV is very heavy. Use wood blocks to hold the machine up while working underneath it!
2. Insert the bracket between the legs and the base of the machine and retighten the legs, (Fig. 2).
Fig. 1 Fig. 2
3. Insert the Drip Tray onto the mounting bracket, (Fig. 3). Make sure the drain fitting is still protruding through the hole.
Fig. 3
Optional Drip Tray Drain
A separate drain tube (not supplied) may be attached to fitting in the bottom of the tray, if desired. Note: Drill a ¼” hole in the center
of the fitting, before attaching the drain hose. Direct the other end of this hose into a permanent drain.
Alternate Evaporator Drain
For locations where the Drip Tray is not desired, connect a separate drain hose (not supplied) to the Evaporator Drain Fitting and direct
the other end of this hose into a permanent drain.
CAUTION: FAILURE TO INSTALL THE DRIP TRAY OR ALTERNATE EVAPORATOR DRAIN WILL RESULT IN WATER DRIPPING ON TO
THE COUNTER AND/OR FLOOR UNDER THE DISPENSER.
8
OPERATING CONTROLS AND INTERFACE
1. Master ON/OFF Switch: Disconnects AC Power to the dispenser.
2. Hot Water Handle: Pull and Hold to dispense hot water manually.
3. Door Interlock Switch: Unit will not dispense product if the door is open.
4. LCD Display: Displays status, programming menus and fault messages.
5. Volume Selection: Rotate dial to the desired volume prior to dispensing product.
6. Dispense Switches (A-B-C): Push and Release to dispense the desired product.
(These also double as programming switches in the Set-Up mode).
7. Function Selector Switch: Allows the user to set the dispenser into different dispensing modes.
a. RINSE: Dispenses hot water only - Flushes the mix chamber and dispense tip.
b. RUN: Normal dispense mode - Dispenses mixed product (concentrate and water).
c. PRIME: Dispenses concentrate only – Primes the concentrate pump.
8. Hidden Set-Up / Programming switches.
a. Press and hold the Right switch for 5 sec. to enter in the Set-Up mode.
b. Use the Right switch to scroll down and the Left switch to scroll up through the menu screens.
4
8
6
7
5
3
2
1
41129 052208
9
INITIAL FILL & HEAT
1. Confirm the water supply is on.
2. Connect the dispenser to the power source.
3. Turn the Master ON/OFF Switch ON and select RUN on the Function Selector Switch. The LCD will display
“Tank Filling – Please Wait!” and water will begin flowing into the tank.
4. Once the tank is full the dispenser will start heating the water and display “Heating Select Flavor”. Dispenser
models with product chillers will also begin to cool the cabinet at this time.
5. The LCD will display “Ready Select Flavor” when the tank temperature reaches the preset Ready
Temperature.
Note: The time required to heat the water initially will vary depending on the AC Power and the temperature of
the incoming water. While the tank is heating, the dispenser may be readied for use as described in Programming
Functions & Basic Operations.
3
4
41129 052208
10
Rinse Alarm Feature
Periodic rinsing of the mix chambers and dispense tips is essential for proper maintenance and optimum
performance of the dispenser. The automated Rinse Alarm feature has three levels of operation; see Programming
the Dispenser to select the desired alarm mode.
Alarm Level Alarm Mode
Disabled None
Warning Only “Rinse Required” will be displayed 4 hrs prior to the selected time interval to remind the
operator that the Rinse Procedure needs to be preformed soon. The dispenser will continue
to serve product, even if the full time interval elapses.
Brew Lockout “Rinse Required” will be displayed 4 hrs prior to the selected time interval to remind the
operator that the Rinse Procedure needs to be preformed soon. However, the dispenser will
Lockout and not continue to serve product once the selected time interval has elapsed.
NOTE: The time interval between Rinses is adjustable from 8 to 24 hrs. The dispenser is shipped with the Rinse
Alarm disabled, (No Alarm). It is up to the user to determine the Rinse time interval and the level of warning
required, based on their application and maintenance procedures.
Rinse Procedure:
1. Select Rinse on the Function Selector switch.
2. Place a 2 Liter (1/2 Gal) container under the dispense tip.
3. Activate any of the dispense switches until the water flow stops automatically, approximately 10 sec. The
Rinse Alarm message will go away, when the Rinse procedure has been satisfied.
4. Select Run on the Function Selector switch.
1 4
41129 120909
11
BIB Empty Lockout Feature
The dispenser can be set to not dispense product when the concentrate BIB is empty. To enable this feature, first
calibrate the Empty BIB Threshold (refer to Field Calibrating the Empty BIB Warning). Then enable the BIB Empty
Lockout feature (refer to the BIB Empty Lockout menu in Programming the Dispenser). The dispenser will now
Lockout dispensing and display “RIGHT, MIDDLE or LEFT BIB EMPTY – Replace Now!”. Once the BIB has been
replaced, PRIME the concentrate line (refer to Priming the Concentrate Lines) to clear the Empty BIB warning.
NOTE: If the BIB Empty warning reappears, repeat the Priming operation a second time to insure the concentrate
is flowing properly.
Brew Temperature Lockout Feature
The dispenser can be set to not dispense product if the hot water is not up to the preset READY temperature. To
enable this feature, set the READY temperature to the minimum allowable dispense temperature. Then enable
the Brew Lockout feature, refer to READY TEMP and BREW LOCKOUT, in Programming the Dispenser. The
dispenser will display “HEATING – Please Wait” and not allow dispensing until the tank temperature reaches the
preset READY temperature.
Energy Saver Mode
The LCR-3 HV can be set to turn off or lower the temperature when not in use. This feature allows the user to
enable the Energy Saver Mode, set the Idle Time (length of time the dispenser is inactive before the Energy Saver
Mode is activated) and choose between shutting the tank heaters OFF or holding the tank at 140° F (60° C) for
faster recovery, (refer to Programming the Dispenser). When enabled, the dispenser will automatically go into
the Energy Saver Mode after a predetermined time of inactivity, (Idle Time). When in this Mode the display will
show “EnergySaver Mode / Press Any Switch.”
NOTE: Activating any switch on the control panel will cancel the Energy Saver Mode and reset the Idle Timer.
Once the Energy Saver Mode is cancelled, the dispenser will display “Unit Re-heating / E-Saver Mode On” and
not dispense product until the water temperature has reached the normal Tank Temperature. Once the normal
Tank Temp is reached, the dispenser will revert to typical operation and displays.
Optional 2- Product Operation
The LCR-3 HV can be configured to deliver only two coffee products for applications where additional volume
a given product is needed. This feature allows the operator to load the same concentrate into the Left & Middle
position, thus doubling the amount of product that can be dispensed - before having to replace the concentrate.
The dispenser will automatically switch from one concentrate container to the other when a BIB Empty threshold
is exceeded. The LCD will display “(LF or MID) BIB EMPTY - Replace Soon” to indicate that BIB is empty.
To enable this feature, first calibrate the Empty BIB Threshold (refer to Field Calibrating the Empty BIB Warning).
Then select (2) in the 2 or 3 PRODUCTS? menu screen, (refer to Programming the Dispenser).
NOTE: If the operator feels the unit is waiting too long to switch over to the other BIB (i.e. too much clear water
during the switch over) - increase the Empty BIB threshold and retest. Repeat this process until you are satisfied
that the original BIB is nearly empty and switch over time is acceptable.
The operator can choose to replace the empty BIB right away or wait until the second BIB is empty. The dispenser
will continue to switch from one BIB to the other, until it gets two BIB Empty warnings in a row. The dispenser
will then shut down and display “BIB EMPTY - Replace Now!” indicating that both BIB’s are empty. Replace the
BIB’s and PRIME the concentrate line (refer to Priming the Concentrate Lines) to clear the BIB Empty warning.
If the BIB Empty warning reappears, repeat the Priming operation a second time to insure the concentrate is
flowing properly.
NOTE: The BIB EMPTY LOCKOUT feature is automatically enabled when this feature is selected.
41129 071409
12
PROGRAMMING THE DISPENSER
Press the Right Hidden Switch for 5 sec. to enter the programming menu. Use the Left and Right hidden
switches to scroll through the menu screens. Select Exit to leave the programming function and return to normal
operations.
NOTE 1: Flashing menu items indicate which selection is active.
NOTE 2: Values shown below are the factory default values for English units.
NOTE 3: Values in [X - X] are the Min. and Max. for that function.
READY
SELECT FLAVOR
LEFT DISP RATIO
(-) 30:1 (+)
MID DISP RATIO
(-) 30:1 (+)
RIGHT DISP RATIO
(-) 30:1 (+)
LF DISP VOLUME 1
(-) 36.0oz (+)
LF DISP VOLUME 2
(-) 192.0oz (+)
LF DISP VOLUME 3
(-) 384.0oz (+)
MID DISP VOLUME 1
(-) 36.0oz (+)
MID DISP VOLUME 2
(-) 192.0oz (+)
MID DISP VOLUME 3
(-) 384.0oz (+)
RT DISP VOLUME 1
(-) 36.0oz (+)
RT DISP VOLUME 2
(-) 192.0oz (+)
RT DISP VOLUME 3
(-) 384.0oz (+)
LCD DISPLAY ACTION DESCRIPTION
Hold the RT Hidden Switch
for 5 seconds to enter
Programming Functions
Use the (+) or (-) buttons to
adjust the Mix Ratio
Use the (+) or (-) buttons to
adjust the Mix Ratio
Use the (+) or (-) buttons to
adjust the Mix Ratio
Use the (+) or (-) buttons to
adjust the Volume
Use the (+) or (-) buttons to
adjust the Volume
Use the (+) or (-) buttons to
adjust the Volume
Use the (+) or (-) buttons to
adjust the Volume
Use the (+) or (-) buttons to
adjust the Volume
Use the (+) or (-) buttons to
adjust the Volume
Use the (+) or (-) buttons to
adjust the Volume
Use the (+) or (-) buttons to
adjust the Volume
Use the (+) or (-) buttons to
adjust the Volume
Normal Display for LCR models.
Enter the desired Mix Ratio for the concentrate
used in the Left dispenser. [20:1 - 100:1]
Enter the desired Mix Ratio for the concentrate
used in the Middle dispenser. [20:1 - 100:1]
Enter the desired Mix Ratio for the concentrate
used in the Right dispenser. [20:1 - 100:1]
Set the desired SMALL portion control volume:
(0 - 640 oz) or (0 - 18.93L)
Set the desired MEDIUM portion control volume:
(0 - 640 oz) or (0 - 18.93L)
Set the desired LARGE portion control volume:
(0 - 640 oz) or (0 - 18.93L)
Set the desired SMALL portion control volume:
(0 - 640 oz) or (0 - 18.93L)
Set the desired MEDIUM portion control volume:
(0 - 640 oz) or (0 - 18.93L)
Set the desired LARGE portion control volume:
(0 - 640 oz) or (0 - 18.93L)
Set the desired SMALL portion control volume:
(0 - 640 oz) or (0 - 18.93L)
Set the desired MEDIUM portion control volume:
(0 - 640 oz) or (0 - 18.93L)
Set the desired LARGE portion control volume:
(0 - 640 oz) or (0 - 18.93L)
41129 071409
13
ENTER PASSWORD
(-) 0 (+)
SET PASSWORD ?
(-) 0 (+)
2 OR 3 PRODUCTS?
(2) EXIT (3)
SELECT UNITS
ENG EXIT METRIC
REFRIGERATION ?
ON EXIT OFF
DEICE CYCLE TIME
(-) 120 MIN (+)
RINSE ALARM ?
NO EXIT YES
RINSE TIME ?
(-) 12 HRS (+)
RINSE LOCKOUT ?
NO EXIT YES
The following functions can be Password Protected. If you wish to prevent others from accessing these functions,
enter a 4 digit code of your choice. Record your password code [_ _ _ _], as you will need it to access these
functions in the future.
Use the (+) or (-) buttons to
enter password.
Use the (+) or (-) buttons to
change the password.
Select the number of products
to be dispensed
Select the preferred units.
Select OFF to disable the
Refrigeration system
Select the time delay between
automatic deicing of the
cabinet
Select (YES) or (NO)
Use the (+) or (-) buttons to
adjust Rinse Alarm delay.
Select (YES) to enable
Enter the access Code to view the remaining
functions. Factory Default = 0.
Enter your own Code to prevent access to the
remaining functions. [0 to 9999]
Used to switch from standard 3 products to 2
products w/Autoswitching of the Left and Middle
Bibs.
Used to select the preferred units of measurement.
(Oz., Gal, deg F) or (mL, L, deg C)
Select OFF to temporarily override a cooling system
fault and allow the machine to dispense coffee.
If ice builds up on the evaporator - decrease the
delay. If the cabinet is not cold enough - increase
the delay.
Factory Default=120 (2 hrs)[min=30, max=180]
Selecting Yes will enable the Rinse Alarm function,
(see Rinse Alarm)
Enter the desired time between required Rinse
Cycles in hours. [8 to 24 hrs]
Select YES to Lockout dispensing until the Rinse
Alarm has been cleared. Default is NO.
LCD DISPLAY ACTION DESCRIPTION
PROGRAMMING (Continued)
41129 071409
TANK TEMP 190
(-) EXIT (+)
READY TEMP 180
(-) EXIT (+)
CABINET TEMP 38
(-) EXIT (+)
Use the (+) or (-) buttons to
adjust the target Temp.
Use the (+) or (-) buttons to
adjust the target Temp.
Use the (+) or (-) buttons to
adjust the target Temp.
Sets the water Tank temperature:
(120 - 200°F) or (49 - 93°C)
Sets the hot water Ready temperature:
Typically set to the min. desired dispense temp.
Sets the Chilled cabinet target temperature:
(38 - 50°F) or (3 - 10°C)
LCD DISPLAY ACTION DESCRIPTION
If ON
If YES
If NO
to Next Page
14
PROGRAMMING (Continued)
BibEMPTY LOCKOUT
NO EXIT YES
BREW LOCKOUT ?
NO EXIT YES
ENERGY SAVER MODE
NO EXIT YES
E-SAVER IDLE TIME
(-) 4 HRS (+)
E-SAVER TANK TEMP
NO EXIT 140
Select (YES) to enable
Select (YES) to enable
Select (ON) to enable
Use the (+) or (-) buttons to
adjust the Idle Time
Select OFF or 140° F (60°C)
Select YES to Lockout dispensing until the BIB is
replaced and the pump has been Primed. Default
is NO.
Select YES to Lockout dispensing until the hot
water tank is at READY Temp. Default is NO.
Select ON to enable Energy Saver Mode. Default
is OFF.
Enter the amount of inactive time before the
dispenser goes into Energy Saver Mode. Default
is 4 hrs. Maximum is 24 hrs.
Choose OFF to turn the tank heaters off completely
or 140°F (60°C) to hold hot water at 140°F (60°C)
during E-Saver Mode. Default is 140°F (60°C).
LCD DISPLAY ACTION DESCRIPTION
41129 071409
15
LCD DISPLAY ACTION DESCRIPTION
The following functions are for diagnostic and troubleshooting purposes and typically do not have to be adjusted.
Contact your local service agent for assistance before making changes to these functions.
PROGRAMMING (Continued)
CAL LEFT PUMP ?
LEFT
CAL LF PUMP VOL
(-) 58mL (+)
CAL MIDDLE PUMP ?
MIDDLE
CAL MID PUMP VOL
(-) 58mL (+)
CAL RIGHT PUMP ?
RIGHT
CAL RT PUMP VOL
(-) 58mL (+)
CAL HI WTR FLOW
PULL DISPENSER
CAL HI WTR VOL
(-) 1720mL (+)
XXX CAL -> XXX
(-) Tank Temp (+)
BIB EMPTY -> 600
(-) EXIT (+)
Place a 50 mL (#34843.1000)
graduated cylinder under the
dispense tip, then activate the
Left Pump
Use the (+) or (-) buttons to
enter volume collected
Place a 50 mL (#34843.1000)
graduated cylinder under the
dispense tip, then activate the
Middle Pump
Use the (+) or (-) buttons to
enter volume collected
Place a 50 mL (#34843.1000)
graduated cylinder under the
dispense tip, then activate the
Right Pump
Use the (+) or (-) buttons to
enter volume collected
Place a 64oz (2000mL)
container under the dispense
tip, then Press and Hold any
Dispense Switch
Use the (+) or (-) buttons to
enter volume collected
Use the (+) or (-) buttons to
adjust temperature reading
Use the (+) or (-) buttons to
adjust Empty BIB threshold
The Left Pump will dispense concentrate for 10
seconds, then shut off automatically. Collect and
measure the concentrate dispensed.
Enter the volume of concentrate measured from
the Left Pump in mL, (not Oz.)
The Middle Pump will dispense concentrate for
20 seconds, then shut off automatically. Collect
and measure the concentrate dispensed.
Enter the volume of concentrate measured from
the Middle Pump in mL, (not Oz.)
The Right Pump will dispense concentrate for 20
seconds, then shut off automatically. Collect and
measure the concentrate dispensed.
Enter the volume of concentrate measured from
the Right Pump in mL, (not Oz.)
The Dispenser will dispense hot water for 20
seconds, then shut off. Release Dispense Sw.
Collect and measure the water dispensed. Enter
the volume in mL. Default is 1720 mL
Adjust the display reading to match a calibrated
probe inserted next to the Tank Sensor, °F (°C)
Used to set the Conductance Threshold for the
Empty BIB warning. Default is 600
41129 071409
16
LCD DISPLAY ACTION DESCRIPTION
PROGRAMMING (Continued)
XXOVERFLOW > 155
(-) EXIT (+)
XX REFILL -> 155
(-) EXIT (+)
WTR START DELAY
(-) .15SEC (+)
WTR STOP DELAY
(-) .15SEC (+)
TEST SWITCHES ?
UseSwitchToTest
TEST REFILL ?
EXIT YES
TEST HEATER ?
EXIT YES
ENTER ASSET #
(-) 000000 (+)
SERIAL #
LCR 0000000
VIEW FAULTS?
(-) EXIT (+)
LATEST FAULT
NO FAULTS
FACTORY DEFAULTS
NO YES
Use the (+) or (-) buttons to
adjust Overflow threshold
Use the (+) or (-) buttons to
adjust Refill threshold
Use the (+) or (-) buttons to
adjust delay time
Use the (+) or (-) buttons to
adjust delay time
NONE
Momentarily depress (YES)
Momentarily depress (YES)
Use the (+) or (-) buttons to
enter the ASSET NUMBER
NONE
Select (+) to view the Fault
Conditions
Use the (+) or (-) to scroll
through the Faults
Select (YES) or (NO)
Used to set the Conductance Threshold for the
Tank Overflow Probe
Used to set the Conductance Threshold for the
Tank Refill Probe.
Dispense Valve ON Delay. Eliminates weak mix
at the beginning of a dispense.
Dispense Valve OFF Delay. Flushes the mix
chamber at the end of a dispense.
Switch Diagnostic: Activate switches separately to
test. Display will indicate which Switch has been
activated. NOTE: Door Interlock switch must be
held closed.
Refill Valve Diagnostic: Press YES to momentarily
energize the Solenoid. CAUTION: Inlet Valve will
open and water will flow, if connected and turned
ON.
Tank Heater Diagnostic: Press YES to momentarily
energize the Tank Heater Circuit. CAUTION: AC
power will be applied to the Tank Heater Circuit.
Allows the user the option of entering an Asset
Number. Default is 000000
Displays the manufacture’s Serial Number (should
be identical to the Serial Number on the Data
Plate)
This unit stores the last 3 Fault Conditions in
memory for diagnostic purposes.
Displays up to 3 FAULT Conditions or NO
FAULTS, if nothing has failed since the last “Reset
Defaults”.
CAUTION: Selecting YES will RESET all Program-
ming Functions to the Factory Default settings
41129 021709
17
LOADING THE CONCENTRATE
1. Thoroughly mix concentrate by vigorously shaking the product Bag-In-Box (BIB).
2. Pull the BIB connector through the hole provided in the box.
3. Open the dispenser door and locate the appropriate left, middle or right BIB Adapter fitting.
4. Connect the Adapter fitting to the BIB. Make sure the locking mechanism is fully engaged!
5. Place the BIB upright in the machine, rotating it into position with the connector down and facing forward.
6. Rotate the BIB Adapter to avoid sharp bends in the tubing and allow it to be routed between the pumps. Refer
to the Tube Installation Decal on the door for proper routing.
7. Close the cabinet door.
PRIMING THE CONCENTRATE LINES
1. Select PRIME on the Function Selector Switch.
2. Load concentrate per instructions in the section titled Loading the Concentrate.
3. Place a container under the dispense tip.
4. Activate the appropriate pump switch until concentrate flows from the dispense tip, (approx 5 to 10 sec).
5. Repeat steps 2 through 4 for the other two pumps, if needed.
6. Select RUN on the Function Selector Switch.
Note: Concentrate may continue to drip out of dispense tip. The user may wish to run a Rinse Cycle (refer to
Rinsing) after Priming the dispenser to clean out the remaining concentrate.
Fig. 1
Fig. 2 Fig. 3
1 6
41129 052208
18
FILLING CAMBROS OR OTHER LARGE CONTAINERS
The dispenser is designed primarily for containers that will fit under the dispense tip. However, it may be used to
fill larger containers (up to 5 Gal) by use of an extension hose on the dispense tip. Care must be taken to insure
that the mixed product flows freely from the dispense tip into the container.
1. Use a 5/8” I.D. or larger, NSF (National Sanitation Foundation) approved hose.
2. Use as short a hose as possible with no loops, bends or kinks in it.
3. Insure that the outlet of the hose is below the dispense tip and that the mixed product flows freely into the
container.
4. A properly sized and positioned hose will not run full or back up into the dispense tip. Failure to follow these
directions can alter the mix ratio and/or cause flooding of the vent tube.
NOTE: Recovery time will be dependent on the temperature of the supply water and the supply voltage to the
dispenser.
OPERATING THE DISPENSER
The Cabinet door must be closed & latched and the Function Selector Switch set to RUN to dispense
coffee.
To Dispense Coffee
1. Select the desired volume (1, 2 or 3) using the rotary switch.
2. Place the appropriate container under the dispense tip.
3. Press and release the desired flavor switch to dispense product. The LCD will display “DISPENSING PRODUCT”
“PRESS ANY SWITCH TO STOP”. Note: Pressing any switch after starting a dispense cycle - will abort that
dispense and halt the flow of product.
4. Remove the container and serve accordingly.
To Dispense Hot Water
1. Place container under the hot water dispenser tip.
2. Pull and Hold the Hot Water handle until the water reaches the desired level, then release.
3. Remove the container.
NOTE: For large containers that will not fit under the dispense tip, a short 3/8” diameter NSF approved hose may
be used.
41129 052208
19
CLEANING & PREVENTATIVE MAINTENANCE
General Cleaning and Sanitizing Procedures
Note: The BUNN® Liquid Coffee Dispenser incorporates a “user selectable” rinse reminder feature and can be
set to disable dispensing when it is time to rinse. See Programming Functions to activate this feature.
Daily: RINSING & CLEANING
1. Select RINSE on the Function Selector Switch.
2. Place a 1/2 gal (2 liter) container under the dispense nozzle.
3. Press and Hold any flavor selection switch for approximately twenty seconds or until the hot water is clear
or has no concentrate coloring in it.
4. Wipe splash panels, dispense nozzle, door, and cabinet with a clean sanitary cloth.
Note: To clear the “Rinse” alarm, activate the dispenser until the flow stops automatically (approx. 20 seconds).
The “Rinse” alarm display will turn off when the Rinse Procedure has been satisfied.
Weekly: SANITIZING
1. Select PRIME on the Function Selector Switch and open the dispenser door.
2. Remove the bag connector from the product BIB and disassemble or prop open the internal valve to allow
flow of product through the connector.
NOTE: Cutting the mating fittings from an empty bag makes an excellent “free flowing” connector for this
purpose.
3. Place the bag connector into a one-gallon (3.8 liter) container of warm soapy tap water 140°F (60°C).
4. Place an empty container under dispense tip and activate the corresponding pump until the clean soapy water
is dispensed from the dispense tip.
5. Repeat steps 3 and 4 with warm tap water 140°F (60°C) to rinse the soapy water from the pump tubing.
6. Continue dispensing until the water is clear, and no soapy water is being dispensed.
7. Prepare 2.5 gallons (9.46L) of sanitizing solution by dissolving 1 packet of Kay 5 sanitizer into 2.5 gallons
(9.46L) of 120°F (48.9°C) water to ensure 100 ppm of available chlorine.
8. Again, repeat steps 3 and 4 with the sanitizing solution. Once sanitizing solution is visible, continue to dispense
for 1 minute. Release handle and allow solution to sit for 5 minutes.
9. After soaking for 5 minutes, activate the dispense switch a second time, this time for 2 minutes. After 2
minutes, release the dispense switch.
10. Repeat steps 5 & 6 wit warm tap water to flush out the sanitizing solution from the pump tubing.
11. Reattach the bag connector to product BIB.
12. Close the dispenser door and select NORMAL on the Function Selector Switch.
13. Activate the dispenser until concentrate/water mixture appears. Then dispense 20 ounces (600 ml) container
of concentrate/water mixture and discard.
14. Repeat steps 1 through 13 for other two Pumps.
15. Wipe internal and external surfaces with a clean, sanitary cloth.
Weekly: REFRIGERATION AIR FILTER
1. Remove the screen filter from the bottom of the dispenser.
2. Wash the screen in a mild detergent solution.
3. Use a soft bristled brush to remove all dust and grease.
4. Reinstall the screen.
41129 030910
PREVENTIVE MAINTENANCE
Bunn-O-Matic
®
Corporation recommends that preventive maintenance be performed at regular intervals. Maintenance
should be performed by a qualified service technician. For Technical Service, contact Bunn-O-Matic
®
Corporation at
1-800-286-6070.
NOTE: Replacement parts or service caused by failure to perform required maintenance is not covered by warranty.
Replace pump hoses every 6-Months or as needed.
20
REPLACING THE PUMP TUBING
The pumps and tubing used in this dispenser are designed to give maximum performance and long life. However,
the tubes are a wear item and must be replaced periodically. How long the tubes last is dependent on usage and
properties of the concentrate. Excessive wear will reduce the output of the pumps resulting in a weak mixed
beverage.
Bunn-O-Matic recommends replacing the Pump Tubing a minimum of once every 6 months or sooner, if
warranted.
Refer to the Tube Replacement Instruction on the Cabinet door for details.
1. Rinse the pump tubing with warm tap water (Refer to step 5 of the Weekly Sanitizing instructions) prior to
removing the tubes to avoid concentrate spills.
2. Loosen the thumbscrew securing the tubing retainer plate to the pump housing. Set the retainer plate
aside.
3. Depress the tension screw and remove it from the notch in the pump housing, releasing the tube compression
band.
4. Open the compression band and gently pull the pump tube from around the pump’s rotor.
5. Inspect the pump bands for signs of cracking or excessive wear. Replace if necessary.
6. Apply lubricant (BUNN-O-MATIC part number M2531.0001) to the new pump tubing’s rotor side.
7. Insert the tube onto the mix chamber port, then wrap the new tubing around the pump rotor, making sure
the elbow and clamps end up on the bottom side of the pump housing.
8. Depress the tension screw and insert it in the notch in the pump body, reapplying spring tension to the
compression band.
9. Replace the tubing retainer plate and tighten the thumbscrew.
10. Repeat steps 1 through 9 for the other two pumps.
Note: Replacement Tube/Adapter Kits can be purchased from BUNN-O-MATIC.
Remove Retaining Plate Release Spring Tension Remove Tubing
Lubricate New Tube
Install New Tubing Completed Installation
Thumbscrew
Lubricate between arrows
2.0”
2.0”
Tension
Screw
Tube Clamp
Tension Screw
41129 030910
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27

Bunn LCR-3 HV User manual

Category
Coffee makers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI