Mitel Networks 50006266 Datasheet

Category
Gateways/controllers
Type
Datasheet

This manual is also suitable for

Mitel
®
MiVoice Business (formerly Mitel Communications
Director) deployed on Mitel 3300 Controller provides
businesses with a feature-rich IP communication solution,
with embedded advanced user applications and ample
connections to address the business’s connections and
device needs.
MITEL MiVOICE BUSINESS 3300 CONTROLLERS
DATA SHEET
SPECIFICATION
3300 CX II /
3300 CXI II
3300 MXe III
STANDARD
3300 MXe III
EXPANDED 3300 AX
Maximum number of devices (including
softphones and Contact Center agents)
1
150 350 1,500 400
1,2
Maximum number of IP phones
1
150 300 1,400 125
1,2
Maximum number of SIP devices / users 150 300 1,000 100
Maximum ACD Agents
1
50 100 350 50
Maximum 5550 IP consoles 8 16 24 8
Maximum number of analog phones
3
150 350 1,500 288
Shipped with 2 x ADI 21363 DSP
modules Power Supply
32 Echo Cancellers AMB
1 Quad DSP Module
Power Supply 64 Echo
Cancellers AMB
1 Quad DSP Module
Power Supply 128 Echo
Cancellers AMB
1 Quad DSP Module
Power Supply 40
Echo Cancellers
Main Software Storage Media 16 GB SATA Solid
State Drive
32 GB Solid State Drive or
160GB SATA Hard Drive
32 GB Solid State Drive or
160 GB SATA Hard Drive
2 GB Flash Drive, 4 GB
Flash Drive for Voice Mail
Installed RAM 512 MB 512 MB 512 MB 512 MB
Available MMC Slots 3 6 5 2
MMC Slots for Quad CIM, Single T1/E1,
Quad BRI, and DSP II
Dual FIM, Quad CIM,
Single and Dual T1/E1,
Quad BRI, Quad
DSP, DSP II and
Echo Canceller
Dual FIM, Quad CIM,
Single and Dual T1/E1,
Quad BRI, Quad
DSP, DSP II and
Echo Canceller
Single and Dual T1/E1,
Quad BRI, Quad DSP,
DSP and Echo Canceller
Maximum embedded T1/E1 digital
trunk modules
2 (Does not support
Dual trunk modules)
3 4 1
Maximum embedded BRI modules 2 (Does not support
Dual trunk modules)
3 4 1
MITEL 3300 CONTROLLERS
DATA SHEET | MITEL MiVOICE BUSINESS 3300 CONTROLLERS
2 | MITEL DATA SHEET
SPECIFICATION
3300 CX II /
3300 CXI II
3300 MXe III
STANDARD
3300 MXe III
EXPANDED 3300 AX
10/100/1000 MB Ethernet ports See CXi Controller Data
connectivity section
2 2 2 (10/100 only)
Maximum Quad DSP or DSP II modules 0 (1) 3 (2) 3 (2) 2 (1)
Maximum Echo Canceller Channels 96 64 192 128
Maximum G.729a compression channels
(DSP II=128, Quad DSP=32 Dual DSP=16)
64 with DSP II 128 192 128
Maximum T38 channels 8 32 32 32
Maximum number of NSU’s 0 8 8 2 (R2 NSU only)
Maximum number of digital links (except BRI) 2 16 16 4
Maximum Embedded BRI interfaces
(2 channels per interface)
8 12 12 4
Maximum number of Dual FIM modules 0 4 4 1
Dual FIM can be used to connect 0 NSU, DSU, Peripheral
Cabinets, Triple FIM
card and SX200 Bay
NSU, DSU, Peripheral
Cabinets, Triple FIM
card and SX200 Bay
R2 NSU
Analog Main Board
4,5
6 LS trunks,
4 ONS ports
6 LS trunks,
4 ONS ports
6 LS trunks,
4 ONS ports
0
Analog Option Board
4,5
6 LS trunks,
4 ONS ports
0 0 0
Analog Line card slots
6
0 0 0 12
Maximum number of CIM connected ASU’s 3 12 12 0
Maximum number of Fiber and Copper
connected SX200 Bays
0 7 7 0
Tone generators 128 128 128 128
Tone detector circuits 32 32 32 32
E2T Channels 64 64 128
7
128
DTMF Receivers 128 128 192 128
IP Networking – maximum IP trunks
between MiVoice Business systems
2000 2000 2000 2000
IP Networking – total max IP trunks 2000 2000 2000 2000
SIP Trunking – total maximum SIP trunks 2000 2000 2000 2000
SIP trunking – max SIP trunks
between peers
2000 2000 2000 2000
Maximum controllers in a cluster
8
999 999 999 999
STP and RSTP YES YES YES YES
MITEL 3300 CONTROLLERS (CONT’D)
DATA SHEET | MITEL MiVOICE BUSINESS 3300 CONTROLLERS
SPECIFICATION
3300 CX II /
3300 CXI II
3300 MXe III
STANDARD
3300 MXe III
EXPANDED 3300 AX
Embedded voice mail ports as standard 16 20 20 20
Maximum embedded Voice mail ports 16 30 30 20
Maximum mailboxes
9
750 750 750 750
Storage hours 30 with SSD 130
with HDD
130 with SDD 130
with HDD
130 with SDD 130
with HDD
25
Maximum messages per mailbox 100 100 100 100
VOICE MAIL SPECIFICATIONS
1
Engineering rules apply.
2
For low traffic solutions, like Hospitality systems, up to a maximum of 576 devices will be supported, 288 analog devices and up to 288 IP devices. For systems of this size please refer to Mitel
system engineering.
3
The Maximum Analog device limit is a nominal figure that depends on the Hardware used to connect the Analog devices. Options include the ASU II and the SX200 Peripheral Bay Cabinet.
4
Includes Music-on-Hold (1 source supported), Paging (1 paging zone), System Fail Transfer (2 circuits).
5
Analog trunks support CLASS Signaling for North America and Latin America, ETSI Class for international markets.
6
The Analog Line card is available in two variants; the 24 ONS circuit card and the 4 LS trunks and 12 ONS extension card. Note the 4+12 Card supports 4 SFT circuits.
7
Supports up to 192 ET2 channels when being used in a Trunking Gateway configuration.
8
Up to 999 controllers can be clustered as a single system to support over 65,000 IP ports. Mitel’s MiVoice Business System Data Synchronization technology is used to enable feature
transparency across a cluster of controllers.
9
Up to 748 mailboxes can be used for users or multi-level auto attendant. Two mailboxes are reserved for Administration.
MITEL 3300 CXI II CONTROLLER DATA CONNECTIVITY
Integral 16-port powered Layer 2 10/100 Ethernet switch with embedded 802.af support.
HAS AN ADDITIONAL GIGE CAPABLE LAN PORT
· Provides connection to additional switch ports and router
ALSO HAS A 10/100 WAN PORT THAT IS AN “INTERNET GATEWAY”
· WAN port provides connection to an ISP for Internet access (e.g., DSL or cable)
· WAN port provides NAT and firewall capabilities
· WAN port does not support IP networking
USE EXTERNAL ROUTER FOR IP NETWORKING
· Same as you would with a CX II, MXe III, AX Controller
SIP LINESIDE AND TRUNKING SPECIFICATIONS
Please see the SIP CoE MCD RFC specifications document on Mitel OnLine for up to date SIP specification support.
MITEL MiVOICE BUSINESS 3300 CONTROLLERS | 3
DATA SHEET | MITEL MiVOICE BUSINESS 3300 CONTROLLERS
4 | MITEL DATA SHEET
DIGITAL TRUNK CONNECTIVITY
DUAL EMBEDDED DIGITAL TRUNK MODULE (MXE III CONTROLLER AND AX CONTROLLER)
· Each module has two E1/T1 trunk interfaces (links)
· Provides PRI / QSIG / T1-D4 / DASS II / DPNSS / IDA-P protocol through the controller (No NSU required)
· Each interface can run a different protocol, either PRI,
· QSIG, or T1-D4
DOES NOT SUPPORT:
· Min / Max, NFAS, D-Channel Backup or TDM XNET (Hybrid XNET is supported).
SINGLE EMBEDDED DIGITAL TRUNK MODULE (CX II / CXI II / MXE III / AX CONTROLLERS)
· Each module has a single E1 / T1 trunk interface (link)
· Provides PRI / QSIG / T1-D4 / DASS II / DPNSS / IDA-P protocol through the controller (No NSU required)
· Resiliency (switches to secondary controller)
DOES NOT SUPPORT:
· Min / Max, NFAS, D-Channel Backup or TDM XNET (Hybrid XNET is supported).
EMBEDDED BRI MODULE (CX II / CXI II / MXE III / AX CONTROLLERS)
The Embedded BRI module has four Basic Rate Circuits (total 8 – 64kbs channels)
EACH CHANNEL MAY BE CONFIGURED AS EITHER A:
· T (trunk) interface for links from a BRI Central Office (CO)
· S (subscriber) interface for connecting up to eight BRI devices.
Note: S interfaces support only basic call features such as calling number display for BRI devices (BRI call handling such as Hold or Transfer are not supported). BRI devices are not line powered
from the embedded BRI module.
Note: This module does not support U interfaces.
MITEL STREAMLINE (24-PORT OR 48-PORT VERSIONS)
· Ethernet services over two-wires
· Power over Ethernet
· Cat 3 or better cabling
· Up to 1200 ft
· Simple deployment with a station-side dongle, delivering Ethernet services and power
SPECIFICATION 3300 CONTROLLER
ANALOG SERVICES
UNIT (ASU)
NETWORK SERVICES
UNIT (NSU) STREAMLINE
Height CX II / CXi II / MXe III –
3.5 in. (8.9 cm.) (2U)
AX – 13.35 in.
(39.90 cm.) (7 U)
ASU – 1.75 in.
(4.454 cm.) (1 U)
ASU II – 3.3 in. (8.4 cm.)
(2 U)
1.75 in. (4.454 cm.)
(1 U)
1.75 in. (4.454 cm.)
(1 U)
Width CX II / CXi II / MXe III
17.75 in. (45.1 cm.)
(19 in. rack mountable)
AX – 17.4 in. (44.20 cm.)
17.75 in. (45.1 cm.)
(19 in. rack mountable)
17.75 in. (45.1 cm.)
(19 in. rack mountable)
17.13 in. (43.5 cm.)
(19 in. rack mountable)
Depth CX II / CXi II – 16.5 in.
(41.9 cm.) MXe III –
20.25 in. (51.4 cm.)
AX – 13.87 in. (35.23 cm.)
ASU – 15.5 in.
(39.4 cm.) ASU II –
13.3 in. (33.8 cm.)
15.5 in. (39.4 cm.) 9.92 in. (25.2 cm.)
Weight CX II / CXi II – 19.8 lb.
(8.98 kg.) MXe III –
28 lb. (12.7 kg.)
AX – 39.70 Ib. (18.01 kg.)
ASU – 10.61 lb.
(4.81 kg.) ASU II –
14.1 lb. (6.4 kg.)
8.41 lb. (4.27 kg.) 7.96 lb. (3.61 kg.)
DIMENSIONS
DATA SHEET | MITEL MiVOICE BUSINESS 3300 CONTROLLERS
MITEL MiVOICE BUSINESS 3300 CONTROLLERS | 5
SPECIFICATION 3300 CONTROLLER
ANALOG SERVICES
UNIT (ASU)
NETWORK SERVICES
UNIT (NSU) STREAMLINE
Temperature 40° to 122°F
(4° to 50°C)
40° to 122°F
(4° to 50°C)
40° to 122°F
(4° to 50°C)
(10°C to 50°C)
Humidity 5% to 95%
relative humidity,
non-condensing
5% to 95%
relative humidity,
non-condensing
5% to 95%
relative humidity,
non-condensing
10% to 95%
relative humidity,
non- condensing
Max. Heat Dissipation – fully loaded CX II / CXi II – 170 BTUs
per hour MXe III– 750
BTUs per hour AX –
1024 BTUs per hour
ASU – 170 BTUs per
hour ASU II – 260 BTUs
per hour
60 BTUs per hour 24-Port: 61 BTUs per
hour 48-Port: 81 BTUs
per hour
Air Flow 46 cubic ft. / min. at
maximum output of
fans AX – 110 cubic ft.
Acoustic Emissions Max 50dBA continuous,
75dBA intermittent
(<10% duty cycle)
OPERATIONAL ENVIRONMENT
Conversion factors: One watt is equal to 3.412 BTUs per hour. One ton of refrigeration is equal to 12,000 BTUs per hour or 3.516 Kilowatts, and 0.75 kilowatt-hour is equal to one ton
of refrigeration.
SPECIFICATION 3300 CONTROLLER
ANALOG SERVICES
UNIT (ASU)
NETWORK SERVICES
UNIT (NSU) STREAMLINE
Input / Disconnect IEC320-C14 Class 1
AC Receptacle 2 AC
Receptacles on AX
and MXe III with
redundant power
IEC320-C14 Class 1
AC Receptacle
IEC320-C14 Class 1
AC Receptacle
IEC320-C14 Class 1
AC Receptacle
Input Voltage / Frequency Rating 100 – 240 VAC
50 / 60 Hz
100 – 240 VAC
50 / 60 Hz
100 – 240 VAC
50 / 60 Hz
100 – 240 VAC
50 / 60 Hz
Input Power CX II / CXi II – 250 W
MXe III – 200 W MXe III
Expanded – 250 W
AX – 300 W
ASU – 75 W max
ASU II – 125 W max
NSU – 20 W R2
NSU – 30 W
24-Port: 16.5W
48-Port: 22W
AC Source 90 – 264 VAC 90 – 264 VAC 90 – 264 VAC 90 – 264 VAC
Frequency Range 47 – 63 Hz 67 – 63 Hz 67 – 63 Hz 67 – 63 Hz
SYSTEM INPUT POWER REQUIREMENTS
9
For more technical specifications on the StreamLine, please refer to the StreamLine Data Sheet at mitel.com/streamline.
DATA SHEET | MITEL MiVOICE BUSINESS 3300 CONTROLLERS
MITEL
|
SIMPLY COMMUNICATING
®
GLOSSARY
ACD Automatic Call Distribution
ASU Analog Services Unit
BRI Basic Rate Interface
BTU British Thermal Unit
CAS Channel Associated Signaling
CCS Common Channel Signaling
CIM Copper Interface Module
CLASS Custom Local Access Signaling Services
DASSII Digital Access Signaling System #2
DID / DDI Direct Inward Dial / Direct Dial In
DNI Digital Network Interface
DPNSS Digital Private Network Signaling System
DSP Digital Signal Processor
DTMF Dual Tone Multi-Frequency
FIM Fiber Interface Module
IP Internet Protocol
ISDN Integrated Services Digital Network
LS Loop Start Trunk
MMC MITEL Mezzanine Card
MOH Music on Hold
MSDN Mitel Superswitch Digital Network
NFAS Non-Facilities Associated Signaling
NSU Network Services Unit
OPS Off Premises, long loop analog PBX ports
PRI Primary Rate Interface, ISDN
QSIG Q-Signaling Protocol
RSTP Rapid Spanning Tree Protocol
SIP Session Initiation Protocol
STP Spanning Tree Protocol
T38 ITU protocol to send FAX transmission across
IP Networks
VM Voice Mail
XNET Switched Networking
TRUNKING
GATEWAY A 3300 Controller used specifically to land PSTN
trunks and route them onto a User Gateway
USER
GATEWAY A 3300 Controller / Server used specifically to manage
and control Telephones. External traffic is routed via a
Trunking Gateway
3300
CONTROLLER Mitel’s telephony platform that runs Mitel MiVoice
Business (formerly Mitel Communications Director (MCD))
11.13.13
mitel.com
THIS DOCUMENT IS PROVIDED TO YOU FOR INFORMATIONAL PURPOSES ONLY. The information furnished in this document, believed by Mitel to be accurate as of the date of
its publication, is subject to change without notice. Mitel assumes no responsibility for any errors or omissions in this document and shall have no obligation to you as a result
of having made this document available to you or based upon the information it contains.
M MITEL (design) is a registered trademark of Mitel Networks Corporation. All other products and services are the registered trademarks of their respective holders.
© Copyright 2013, Mitel Networks Corporation. All Rights Reserved.
FOR MORE INFORMATION ON OUR WORLDWIDE OFFICE LOCATIONS, VISIT OUR WEBSITE AT MITEL.COM/OFFICES
GLOBAL HEADQUARTERS
Tel: +1(613) 592-2122
Fax: +1(613) 592-4784
ASIA PACIFIC
Tel: +61(0) 2 9023 9500
Fax: +61(0) 2 9023 9501
U.S.
Tel: +1(480) 961-9000
Fax: +1(480) 961-1370
EMEA
Tel: +44(0)1291-430000
Fax: +44(0)1291-430400
CALA
Tel: +1(613) 592-2122
Fax: +1(613) 592-7825
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Mitel Networks 50006266 Datasheet

Category
Gateways/controllers
Type
Datasheet
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI