FMI SMA18VNA Operating instructions

Type
Operating instructions

This manual is also suitable for

Figure 1 - Removing Log Set
Figure 2 - Installing Replacement Log Set
Save these instructions for future reference
REPLACEMENT LOG SET
INSTALLATION INSTRUCTIONS
FOR SMA18, SMA24, SBJ18 AND SBJ24 GAS LOG HEATERS
WARNING: If log set has been in use, make sure
control knob is in the OFF position, unit is cold and
gas has been turned off.
Part No. Description Qty.
114742-01
114742-03
114743-01
114743-03
111817-08
111824-01
Your replacement kit will contain only one log set assembly depend-
ing on your model. If there is a problem with your replacement log
set contact the authorized dealer where you bought the set or FMI
PRODUCTS, LLC at 1-866-4537.
Items Needed for Installation:
• 5/16'' Hex Socket Wrench or Nut Driver
• Phillips Screwdriver
• 5/8'' Wrench or Adjustable Wrench
1. Remove six screws from sides of log set assembly (three on
each side). Remove log set assembly (see Figure 1).
2. 18''modelsonly:Disconnectexiblegaslinefromvalveand
burner(seeFigure1).Discardexline.
3. Place new log set assembly over chassis and align holes on
bracket with holes on chassis (see Figure 2).
4. Replace six screws removed in step 1.
1
1
1
1
1
2
Replacement Log Set 18'' - SMA18
Replacement Log Set 18'' - SBJ18
Replacement Log Set 24'' - SMA24
Replacement Log Set 24'' - SBJ24
Flex Tube
Compression Nut/Sleeve
24" Set
18" Set
Bracket
Bracket
Chassis
Chassis
Disconnect
Flexible
Gas Line
24" Set
18" Set
2
118526-01
REV. B
02/11
2701 S. Harbor Blvd.
Santa Ana, CA 92704
1-866-328-4537
www.fmiproducts.com
Figure 3 - Routing and Installing Flexible Gas Line for 18'' Models
(Log Set Not Shown For Clarity)
5. 18'' Models Only:Toassemblenexexline,insertextubeinto
end of compression nut with small opening. Place sleeve over
endofextubeandintocompressionnut.Repeatforotherend.
Attachnewexiblegaslinetovalveandburnerroutedthrough
grate as shown in Figure 3. It is very important that you route
theexlinethroughthebacklegonthegrate.Itcouldinterfere
withplacementinreplaceifroutedaroundleg.
Checking Gas Connections
WARNING: Test all gas piping and connections, in-
ternal and external to unit, for leaks after installing or
servicing. Correct all leaks at once.
WARNING: Never use an open ame to check for a
leak. Apply a noncorrosive leak detection uid to all
joints. Bubbles forming show a leak. Correct all leaks
at once.
Sleeve
Compression Nut
Compression
Nut
Sleeve
Burner
Valve
  • Page 1 1
  • Page 2 2

FMI SMA18VNA Operating instructions

Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI