  • Hello! I am an AI chatbot trained to assist you with the Miller LDR-14 REMOTE CONTROL Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
OWNER’S MANUAL
OM-2808 196 319H
May 2005
For LDR-14 Remote Control 043 955
READ SAFETY BLOCKS in welding power
source Owners Manual before proceeding.
WARNING
1. Typical Connection
Y Stop engine.
1 LDR-14 Remote Control
2 Remote 14 Receptacle
3 120 V AC Auxiliary Power Receptacle
Insert LDR-14 remote 14 plug into match-
ing 14-socket receptacle on welding gener-
ator. Tighten collar.
Insert LDR-14 auxiliary power plug into
matching 120 V AC receptacle on welding
generator.
1
802 173-K
3
2
2. Using LDR-14 120 V AC Receptacle
1 120 V 20 A AC GFCI
Receptacle
Receptacle supplies 60 Hz single-
phase power at weld/power speed.
Maximum output from receptacle
equals maximum output from cor-
responding receptacle on welding
generator.
Overload protection is provided by
the corresponding ac receptacle
circuit breaker on the welding gen-
erator.
If a ground fault is detected, the
LDR-14 GFCI Reset button pops
out and the receptacle does not
work. Check for faulty tools
plugged in receptacle. Press but-
ton to reset GFCI receptacle and
resume operation.
. At least once a month, run en-
gine at weld/power speed and
press test button to verify
GFCI is working properly.
1
OM-2808 Page 2
3. Combination Remote Amperage/Voltage Control
A PipePro 304 is shown in example. See welding generator Owner’s Manual for
information on using remote controls with your unit.
NOTE
Ref. 189 438-A
Example Of Remote Voltage Control
Set Switch
In Example:
Process = Stick (Electrode Hot)
Front Panel Amperage Setting = About 185 A (Midrange)
Remote Control Amperage Range = 5 to 185 A
Min
5 A DC
Set Desired Maximum
Amperage For Application
Adjust remote control to increase
or decrease weld output.
Example Of Combination Front Panel
And Remote Amperage Control
Set Desired Process
Max
185 A DC
In Example:
Process = MIG
Front Panel Voltage Setting = Any Position
Remote Control Voltage Range = 10 to 34 V DC
Set Switch
Min
10 V DC
Control Position Does Not
Matter In MIG
Adjust remote control to increase
or decrease weld output.
Set Desired Process
Max
34 V DC
OM-2808 Page 3
4. Wiring Diagram
221 070B
OM-2808 Page 4
5. Parts List
Y Read warning label on remote control before servicing.
. Hardware is common and
not available unless listed.
802 426-C
1
2
10
3
6
4
5
7
8
9
Figure 1. Complete Assembly
Description
Part
No.
Dia.
Mkgs.
Item
No.
Complete Assembly
Quantity
1 196085 Box, Outlet/Control Weatherable W/Covers & Hardware 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 151981 Rcpt, Str Dx Grd 2p3w 20a 125v *520r Gfi 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 035897 Pot, Cp Std Slot 1t 2. W 1k Linear 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 097924 Knob, Pointer 1.625 Dia X .250 Id W/Set Screwsplstc 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 209603 Cable,Set Spliced W/Molded Jacket 6 ft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 196088 Plate, Ident Control Rating 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 134734 Conn, Circ Ms/Cpc 14pin Size 20 Plug Cable Pushin 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
134731 Conn, Circ Ms/Amp Pin Pushin 1418ga .110.150 Insu 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 079739 Conn, Circ Cpc Clamp Str Rlf Size 1720 .703od 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 196087 Plug, Str Grd 2p3w 15a 125v Nema 515 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10 196003 Label, warning electric shock can kill 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
/