OWNER’S MANUAL
OM-2808 196 319H
May 2005
For LDR-14 Remote Control 043 955
READ SAFETY BLOCKS in welding power
source Owner’s Manual before proceeding.
WARNING
1. Typical Connection
Y Stop engine.
1 LDR-14 Remote Control
2 Remote 14 Receptacle
3 120 V AC Auxiliary Power Receptacle
Insert LDR-14 remote 14 plug into match-
ing 14-socket receptacle on welding gener-
ator. Tighten collar.
Insert LDR-14 auxiliary power plug into
matching 120 V AC receptacle on welding
generator.
1
802 173-K
3
2
2. Using LDR-14 120 V AC Receptacle
1 120 V 20 A AC GFCI
Receptacle
Receptacle supplies 60 Hz single-
phase power at weld/power speed.
Maximum output from receptacle
equals maximum output from cor-
responding receptacle on welding
generator.
Overload protection is provided by
the corresponding ac receptacle
circuit breaker on the welding gen-
erator.
If a ground fault is detected, the
LDR-14 GFCI Reset button pops
out and the receptacle does not
work. Check for faulty tools
plugged in receptacle. Press but-
ton to reset GFCI receptacle and
resume operation.
. At least once a month, run en-
gine at weld/power speed and
press test button to verify
GFCI is working properly.
1