Plumbing Socket Set
Wrench
Tools Required
Tools Required
Main Body x1 Cover Plate x1 Handle x1
A B C D E F
Screw x2 Anchor x2 Allen Key x1
F
Allen Key x1
Main Body x1 Cover Plate x1 Handle x1 Screw x2 Anchor x2 Allen Key x1
A B C D E F
Wrench Plumbing Socket Set
TBA
9
6
5
4
1
8
7
3
2
Number Part
MIZU SILK SHOWER MIXER - 9510746
Quantity Chrome Matte
Black
Brushed
Nickel
Brushed
Gun
Metal
1-3
4
5
6-8
9
Mixer Handle Set Complete 2265003
2265020
2265024
2265016
2265002
2265019
2265023
2265015
2265001
2265018
2265022
2265014
2265000
2265017
2265021
2265013
1
Concealed Wall Mixer Cap
Concealed Wall Mixer Cartridge Sleeve
Concealed Shower Mixer Plate Set
Allen Key 2.5mm
1
1
1
1
x
x
x
x
x
x
xxx
x
x
x
x
x
x
x
x
x
x
x
*
1
2
4
5
Milli Meld Microphone Handshower with
Water Inlet Swivel Wall Bracket (4 Star)
We recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive materials. Damage caused by
any improper treatment is not covered by the product warranty. Refer to Warranty Conditions
Plumbers, please ensure a copy of the installation
instruction is left with the end user for future reference.
Published 21/04/2023 Page 01
Milli - Meld Microphone Handshower of 01
Noggin
Wall
11
Connect Mixer (1) to hot and cold Water Supply (3).
Pressure check all connections.
Connect shower pipework to the top outlet and bath pipework to
the bottom outlet.
Leaking joints are not covered by the warranty.
1.
2.
3.
Remove Inlet Fitting by loosening the Set Screws.
Ensure the wall penetration is sealed prior to connecting any fittings.
Apply thread tape or appropriate sealant to Water Feed Thread and attach Inlet Fitting using 10mm Allen key.
Fit the Supply Post Body as assembled onto the Inlet Fixing, secure by tightening the Set Screws.
Attach Hose and Hand Shower.
Optional Check Valve to be used if required.
Test function and water flow on Hand Shower.
Check for water leaks.
1.
2.
3.
4.
5.
6.
7.
8.
Tapware is to be installed by a Licenced Plumber in accordance with AS/NZS 3500:
Recommended working water pressure 300kPa - 500kPa. Maximum water temperature is 65 deg°.
Diagram
500
83
Ø32 Ø55
82.3
Ø22.5
201
Remove Inlet (x) Fitting by loosening the Set Screws (x).
Ensure the wall penetration is sealed prior to connecting any fittings.
Apply thread tape (x) or appropriate sealant to Water Feed Thread (x) and attach Inlet Fitting (x) using 10mm
Allen key.
Fit the Supply Post Body (x) as assembled onto the Inlet Fixing (x), secure by tightening the Set Screws (x).
Attach Hose (x) and Hand Shower (x).
Optional Check Valve (x) to be used if required.
Test function and water flow on Hand Shower (x).
Check for water leaks.
Installation
83
Ø32 Ø55
82.3
Ø22.5
201
1.Ensure the wall penetration is
sealed prior to connecting
any fittings.
2.Apply thread tape or
appropriate sealant to G1/2"
Water Feed Thread.
3.Screw the brass connector to
the G1/2" threaded water
feed pipe.
4.Push the wall connection
bracket into the brass
connector to fit.
5.Tighten locking screws with
allen key.
6.Push the decorative cover plate
to the wall.
83
Ø32 Ø55
82.3
Ø22.5
201
1.Ensure the wall penetration is
sealed prior to connecting
any fittings.
2.Apply thread tape or
appropriate sealant to G1/2"
Water Feed Thread.
3.Screw the brass connector to
the G1/2" threaded water
feed pipe.
4.Push the wall connection
bracket into the brass
connector to fit.
5.Tighten locking screws with
allen key.
6.Push the decorative cover plate
to the wall.