Addvent AVAC9000W Installation Instructions And User Manual

Category
Mobile air conditioners
Type
Installation Instructions And User Manual

Addvent AVAC9000W is a portable air conditioner with a 24-hour timer, allowing you to set it to turn on or off automatically. It has three fan speeds (high, medium, and low) and three modes (cool, dehumidify, and fan only). The cooling mode cools the air and exhausts hot air outside through the exhaust tube, while the dehumidify mode removes moisture from the air without cooling it. The fan mode simply circulates the air without cooling or dehumidifying it. The AVAC9000W has a built-in air filter that helps to remove dust and other particles from the air.

Addvent AVAC9000W is a portable air conditioner with a 24-hour timer, allowing you to set it to turn on or off automatically. It has three fan speeds (high, medium, and low) and three modes (cool, dehumidify, and fan only). The cooling mode cools the air and exhausts hot air outside through the exhaust tube, while the dehumidify mode removes moisture from the air without cooling it. The fan mode simply circulates the air without cooling or dehumidifying it. The AVAC9000W has a built-in air filter that helps to remove dust and other particles from the air.

AVAC9000W
Portable Air Conditioner
with 24 hour timer
Installation Instructions and User Guide
IMPORTANT SAFEGUARDS
WHEN USING ANY ELECTRICAL APPLIANCE, BASIC SAFETY
PRECAUTIONS SHOULD ALWAYS BE FOLLOWED.
PLEASE READ ALL INSTRUCTIONS CAREFULLY
AND RETAIN FOR FUTURE REFERENCE
AVAC9000W[15]instructions 9/4/15 09:43 Page 1
2
Safety Instructions
Never use this appliance for anything other than its intended purpose.
Your air conditioner is designed to be used in a house, office and similar
conditions and should not be used for any other purpose.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
Always keep the unit in an upright position to avoid damage to the cooling
system.
Be sure that the air inlets and outlets are not blocked or covered.
Don t put any object into the air inlet or outlet of the unit.
In order to avoid overheating, do not cover the unit while it is plugged in or
in-use.
Never connect the unit to a defective socket.
Never locate the appliance immediately below a socket-outlet.
Never unplug the air conditioner while it is operating.
This could damage the electronic circuits.
Leave at least 300mm space around the unit.
To avoid tripping the circuit, do not use an extension cord for this unit.
To turn on your unit, insert the plug into the socket and press the power
button.
Do not bend or crush the warm air exhaust hose.
Do not place the power cord under a carpet.
This appliance is for ordinary indoor use. Never use the appliance in the
immediate surroundings of a bath, a shower, a swimming pool or a
greenhouse.
Keep the appliance in the vertical position during transportation. After
unpacking, place the unit upright to allow the refrigerant to stabilise, and wait
3 hours before use.
Any damage resulting from failure to comply with these instructions is
excluded from the warranty. Do not install and use your air conditioner
before completely reading these instructions.
CAUTION: Dispose of packaging material safely according to local regulations
WARNING
AVAC9000W[15]instructions 9/4/15 09:43 Page 2
3
Components
1 Control panel
2 Air outlet
3 Carry Handle
4 Caster
5 Air Filter
6 Air outlet (Heat exchange)
7 Air intake (Evaporator)
8 Air intake (Condenser)
9 Water outlet drain for
continuous drain operation
(dehumidify mode only)
10 Water outlet drain note:
please ensure that this is
firmly fixed before operation
11 Power supply cord
Power supply 220-240V/50Hz
Rated cooling capacity kW 2.64
Rated input W 1000
Energy Efficiency Class (EN14511) EER A
Moisture removal l/h 1.4
Air circulation volume m
3
/h 280
Temperature Setting Range °C 16-32
Refrigerant/Charge g R410-A
Noise Level dB(A) 53
Body dimension WxHxD mm 420x700x340mm
Net weight kg 25
Warranty: One Year return to base
Specifications
AVAC9000W
AVAC9000W[15]instructions 9/4/15 09:43 Page 3
4
Operation
Control Panel
Power Control
The power control turns the unit on and
off.
Warning Light
Condensed water may accumulate in the
unit. If the internal tank becomes full, the
Warning Light will shine and the unit will
not operate until the unit has been
drained.
Mode Control
The Mode Control has 3 settings:
• Cool • Dehumidify • Fan
The settings are adjusted with Mode
Control button. A light will indicate
which setting is currently being used.
• Cooling Mode
During the cooling mode the air is
cooled and hot air is exhausted to the
outside through the exhaust tube.
Adjust fan speed and air temperature
to suit your desired comfort level.
Note : The air exchange hoses must
vent outside the room when using
cool mode.
• Dehumidify Mode
Air is dehumidified as it passes
through the unit, without being in full
cooling mode. If room temperature is
>25 degree Celsius, fan speed can be
adjusted; otherwise fan speed is fixed
to "low". Note : If the unit is to be
used as a dehumidifier, do not
connect the exhaust hose let the
warm air return to the room.
Continuous drainage is then
necessary.
Fan Mode
Air is circulated throughout the room
with no cooling.
Note: unit does not need to be vented in
Fan mode
Fan Speed Control
The Fan Speed Control has 3 settings:
High, Medium, and Low.
Timer
Auto turn off :With machine in running
mode, press timer button to select
number of hours you would like the unit
to run in air conditioning mode until it
automatically shuts off.
Auto turn on : With machine in stand by
mode, press timer button to select
number of hours until you would like the
unit to automatically start running in air
conditioning mode.
Timer / Temp set controls
• Used for adjusting the timer and
thermostat.
• The default display is room
temperature.
AVAC9000W[15]instructions 9/4/15 09:43 Page 4
5
Operation
Remote Controller
• In cooling mode, when " + " or " - "
button is pressed, the set
temperature is displayed and may be
adjusted. After 15 seconds the display
will revert back to room
temperature. Temperature is only
adjustable in cool mode. The time is
adjustable between 1~24 hours.
Note : By pressing both " + " / " - " set
buttons at the same time, the display will
toggle between Celsius and Fahrenheit.
Air Conditioner Remote Control (batteries not included)
The functions work the same as your air conditioner's touch controls.
All key function can be accessed from the remote control.
Batteries : Remove the cover on the
back of the remote controller and
insert the batteries with the (+) and
(-) poles pointing in the correct
directions.
CAUTION:
Use only AAA or IEC R03
1.5V batteries. Remove the batteries if
the remote controller is not used for a
month or longer. Do not attempt to
recharge the supplied batteries All
batteries should be replaced at the same
time. Do not dispose of the batteries in a
fire as they may explode.
After switching the air conditioner off, you must wait 3 minutes before switching it
back on again.
AVAC9000W[15]instructions 9/4/15 09:43 Page 5
Installation
6
Exhaust Duct Set Assembly and Installation
Connect exhaust hose assembly to the back of the unit. Extend
supplied hose to desired length and locate the exhaust nozzle
through the window for ventilation.
Insert both ends of the exhaust hose into the two exhaust
nozzle connectors by twisting anti-clockwise until they stop.
Fix one of the connectors to the rear outlet of the unit.
This is achieved by sliding the nozzle connector downwards
over the exhaust outlet of the unit ensuring that the lugs on
the nozzle connector are engaged with the grooves on the
connector of unit.
Fix the other exhaust nozzle connector to the exhaust
nozzle.
Extend the exhaust hose and close the window as much as
possible trapping the exhaust nozzle.
Semi-permanent Installation
If required, your appliance can also be installed
semi-permanently.
Drill a 125mm hole in an outside wall* or through a
window pane.
The unit should not be within 300mm of any wall.
Fit the flange accessory fixture provided in the hole.
Fit the exhaust hose in the housing at the back of the
appliance.
Insert the other end of the exhaust hose to the flange
previously fit on the wall as shown.
When the hose is not in use, place the cap for connector to
cover the hole.
NOTE : When installing the air conditioner semi permanently,
you should leave a door slightly open (as little as 1cm) to
guarantee sufficient ventilation.
* Installing through an outside wall: you are recommended to
insulate the section of wall using suitable insulation material.
Exhaust
hose
Exhaust nozzle
Exhaust nozzle
connectors (2)
AVAC9000W[15]instructions 9/4/15 09:43 Page 6
7
Troubleshooting
Problem Cause Solution
The unit does not Power Failure Check Fuse
function
The unit functions for only Improper thermostat Decrease thermostat setting by
brief periods in cooling mode setting adjusting temperature setting
Warning light indicator Internal condensate Drain unit via drain
illuminated tank full plug at rear of unit
Unit functions but Windows open Close windows
does not cool
Another source of heat Remove source of heat
in room or too many
people in room
Thermostat temperature Decrease thermostat setting by
setting too high adjusting temperature setting
Air filter blocked Clean filter
Air conditioner capacity Consult supplier
is unsuitable for the size
of room or conditions
Loss of refrigerant Call Addvent
Exhaust hose blocked Remove obstruction
The following cases may not always be a malfunction, please check it before
asking for service.
Installation
For continuous/fixed drainage (dehumidify mode)
If you wish to have the unit continuously drain, please
follow the following instructions:
• You will need a 25mm (1 inch) PVC hose
• Remove the cover from the drainage outlet
9 in top figure.
• Remove the soft rubber stopper inside the cover.
• Insert the drain pipe through the ring of the stopper.
• Re-fit into to the drainage outlet.
AVAC9000W[15]instructions 9/4/15 09:43 Page 7
Telephone: 0117 923 5375 Fax: 0117 923 5374
Victoria Road, Avonmouth, Bristol BS11 9DB www.addvent.co.uk
ISSUE 1/0415
Maintenance
Maintenance after using
If unit is dirty use a mild detergent and damp cloth.
1 If the appliance will not be used for a long time, be sure to pull out the rubber drainplug
to allow the water to drain.
2 Before storing away run the unit in fan mode only for few hours to dry any moisture on
the coils to prevent mould.
3 Clean the air filter and reinstall it.
4 Remove the air hoses and store; cover the wall vent with the supplied cap.
Appliance Maintenance
1 Turn off the power supply. Turn off the appliance first before disconnecting from
power supply
2. Wipe with a soft dry cloth. If the unit is dirty use a mild detergent and damp cloth.
3 Never use volatile substances such as petrol or polishing powder to clean the
appliance.
4 Never pour water onto the main unit.
Air Filter Maintenance
It is necessary to clean the air filter after using it for about 100 hours.
Clean it as follows:
1 Stop the appliance and remove the air filter.
Stop the appliance first, then pull back the air filter.
2 Clean and reinstall the air filter. If the dirt is conspicuous, wash it with a solution
of detergent in lukewarm water. After cleaning, dry it in a shaded and cool place, then
reinstall it.
4 Clean the air filter every two weeks. If the air conditioner operates in an
extremely dusty environment.
Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist. Check
with your local authority or retailer for recycling advice
WARRANTY
ONE YEAR
1
AVAC9000W[15]instructions 9/4/15 09:43 Page 1
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Addvent AVAC9000W Installation Instructions And User Manual

Category
Mobile air conditioners
Type
Installation Instructions And User Manual

Addvent AVAC9000W is a portable air conditioner with a 24-hour timer, allowing you to set it to turn on or off automatically. It has three fan speeds (high, medium, and low) and three modes (cool, dehumidify, and fan only). The cooling mode cools the air and exhausts hot air outside through the exhaust tube, while the dehumidify mode removes moisture from the air without cooling it. The fan mode simply circulates the air without cooling or dehumidifying it. The AVAC9000W has a built-in air filter that helps to remove dust and other particles from the air.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI