In s t a l l a t I o n In s t r u c t I o n s
MI l l e n n I a Is l a n d (ceI lIng Mo u n t )
ra n g e Ho o d s
For use with models:
DHI361
DHI421
DHI482
DHI542
DHI602
Part No. 101744 Rev. B
© 2007 Dacor, all rights reserved
All specifications are subject to change without notice. Dacor assumes no liability for changes to specifications.
Ta b l e o f Co n T e n T s
be f o r e Yo u be g i n ...
IMPORTANT:
INSTALLER• :Intheinterestofsafetyandtominimize
problems,readtheseinstallationinstructions
completelyandcarefullybeforeyoubeginthe
installationprocess.Leavetheseinstallation
instructionswiththecustomer.
CUSTOMER• :Keeptheseinstallationinstructionsfor
futurereferenceandthelocalelectricalinspector’suse.
Ifyouhavequestionsorproblemswithinstallation,contact
yourDacordealerortheDacorCustomerServiceTeam.
Dacor Customer Service Team
Phone: (800)793-0093
Website: www.Dacor.com
Important Safety Instructions .......................................... 1
Product Specifications ..................................................... 3
GeneralSpecifications...................................................... 3
Dimensions........................................................................ 3
Preparing for Installation ...............................................4-6
VerifythePackageContents............................................. 4
PlanningtheLocation........................................................ 5
ElectricalPowerSupply.................................................... 5
PlantheDuctWorkInstallation......................................... 6
Installation Instructions ...............................................7-12
ElectricServiceInstallation............................................... 7
MountingBracketInstallation............................................ 7
AssembletheHood........................................................... 7
HangingtheRangeHood............................................... 10
InstalltheDuctWork....................................................... 10
FinalElectricalInstallation................................................11
FinalChimneyAssembly..................................................11
VerifyingProperOperation.............................................. 12
InstallationChecklist....................................................... 12
1
im p o r T a n T sa f e T Y in s T r u C T i o n s
Important Information About Safety
Instructions
TheImportant Safety Instructions andwarningsinthese
instructionsarenotmeanttocoverallpossibleproblems
andconditionsthatcanoccur.Usecommonsenseand
cautionwheninstalling,maintainingoroperatingthisorany
otherappliance.
AlwayscontacttheDacorCustomerServiceTeamabout
problemsandconditionsthatyoudonotunderstand.
Safety Symbols and Labels
DANGER
ImmediatehazardswhichWILLresultinsevere
personalinjuryordeath.
WARNING
HazardsorunsafepracticeswhichCOULDresultin
severepersonalinjuryordeath.
CAUTION
HazardsorunsafepracticeswhichCOULDresultin
minorpersonalinjuryorpropertydamage.
DANGER
IMPORTANT:Ifyousmellgas:
Donotuseorlightanyappliance.•
Donottouchanyelectricalswitchoruseanyelectricaldevices,includingthetelephone,inyourbuilding.•
Fromaneighbor’sphone,immediatelycallthegassupplier.Followthegassupplier’sinstructions.•
Ifyoucannotcontactthegassupplier,callthefiredepartment.•
IMPORTANT:Donotstoreorusecombustible,flammableorexplosivevaporsandliquids(suchasgasoline)onorin
thevicinityofthisoranyotherappliance.Alsokeepitemsthatcouldexplode,suchasaerosolcans,awayfromthe
cooktop.Donotstoreflammableorexplosivematerialsinadjacentcabinetsorareas(includingaboveandbelowthe
cooktop).
WARNING
TOREDUCETHERISKOFFIRE,ELECTRICSHOCK,ORINJURYTOPERSONS,OBSERVETHEFOLLOWING:
a)Usethisunitonlyinthemannerintendedbythemanufacturer.Ifyouhavequestions,contactthemanufacturer.
b)Beforeservicingorcleaningunit,switchpoweroffatservicepanelandlocktheservicedisconnectingmeansto
preventpowerfrombeingswitchedonaccidentally.Whentheservicedisconnectingmeanscannotbelocked,
securelyfastenaprominentwarningdevice,suchasatag,totheservicepanel.
READANDSAVETHESEINSTRUCTIONS
2
im p o r T a n T sa f e T Y in s T r u C T i o n s
WARNING
Donot1. installoroperatethishoodifithasbeendamaged,dropped,hasdamagedelectricalconduitorwiresoris
notworkingproperly.Iftheproductisdamagedwhenreceived,immediatelycontactthedealerorbuilder.
Usethisrangehoodonlyforitsintendedpurposeasoutlinedintheuseandcaremanual.2. Donotusethisrange
hoodtoventhazardousorexplosivematerialsorvapors.Ifyouhavequestions,contactthemanufacturer.
Thecustomershouldnotinstall,repairorreplaceanypartoftherangehoodunlessspecificallyrecommendedin3.
theliteratureaccompanyingit.Aqualifiedservicetechnicianshouldperformallotherservice.Contactthenearest
Dacorauthorizedservicerepresentativeat(800)793-0093,oratwww.Dacor.comforexamination,repairor
adjustment.
Keepallpackagingmaterialsawayfromchildren.Plasticbagscancausesuffocation.4.
Thisrangehoodmustbeinstalledandgroundedbyaqualifiedinstalleraccordingtotheseinstallation5.
instructions.Allinstallationworkandelectricalwiringmustbeperformedinaccordancewithallapplicablecodes
andstandards,includingfire-ratedconstruction.
Installorlocatethisapplianceonlyinaccordancewiththeseinstallationinstructionsandtherequirements6.
specifiedbythemanufacturerofthecooktoporrange.Improperinstallation,adjustment,alteration,serviceor
maintenancecancauseseriouspersonalinjuryorpropertydamage.
Donotuseanextensioncordoradapterplugwiththisappliance.7.
Sufficientairisneededforpropercombustionandexhaustingofgasesthroughtheflue(chimney)offuelburning8.
equipmenttopreventbackdrafting.Followtheheatingequipmentmanufacturer’sguidelinesandsafetystandards
suchasthosepublishedbytheNationalFireProtectionAssociation(NFPA),andtheAmericanSocietyfor
Heating,RefrigerationandAirConditioningEngineers(ASHRAE)andthelocalcodeauthorities.
Whencuttingordrillingintothewallorceiling,donotdamageelectricalwiringandotherhiddenutilities.9.
Theinstallermustshowthecustomerthelocationofthefuseorjunctionboxsothatthecustomerknowswhere10.
andhowtoturnthepoweroff.
Beforeinstallingorservicingtherangehood,switchpoweroffatthefuseorjunctionboxandlocktheelectrical11.
paneldoortopreventpowerfrombeingswitchedonaccidentally.Whentheelectricalpanelcannotbelocked,
securelyfastenaprominentwarningdevice,suchasatag,totheservicepanel.
Readtheuseandcaremanualcompletelybeforeusingtheappliance.12.
Donottamperwiththecontrols.13.
Neverallowthefilter(s)tobecomeblockedorclogged.Donotallowforeignobjects,suchascigarettesor14.
napkins,tobesuckedintothehood.
Cleanthefilter(s)andallgrease-ladensurfacesoftentopreventgreasefiresandmaintainperformance.15.
Ifthecooktopandrangehoodarenearawindow,useanappropriatewindowtreatment.Avoidlongdrapesor16.
otherwindowcoveringsthatcouldblowoverthecooktopandhood,resultinginafirehazard.
Alwaysruntheblower(s)wheneverthecooktopisoperating.17.
Neverleavetherangeorcooktopunattendedwhenaburner(orelement)isinuse.Boil-oversandgreasyspills18.
maysmokeand/orignite.
Donotleavechildrenaloneorunattendedintheareawherethecooktopandrangehoodareinuse.Neverallow19.
childrentositorstandonanappliance.Donotletchildrenplaywitharange,cooktoporrangehood.Donot
storeitemsofinteresttochildrenaboveoraroundthecooktop,rangeorrangehood.
Theminimumverticaldistancebetweenthecooktopsurfaceandtheexteriorpartofthehoodmustbenoless20.
than30”(762mm).Theverticaldistancemaybelongerfortherangeorcooktopbeingused.Consulttherange
orcooktopinstallationinstructionsfortheminimumandmaximumverticaldistancefromtheappliancebeing
used.
Aminimumoftwopeoplearerequiredtosafelyinstallthisappliance.21.
To reduce the risk of fire, electric shock, serious injury or death when using your range hood, follow basic
safety precautions, including the following:
3
im p o r T a n T sa f e T Y in s T r u C T i o n s
WARNING
TOREDUCETHERISKOFINJURYTOPERSONSINTHEEVENTOFARANGETOPGREASEFIRE:22.
SMOTHERFLAMESwithaclose-fittinglid,cookiesheetormetaltray,thenturnofftheburner.BECAREFULa.
TOPREVENTBURNS.Iftheflamesdonotgooutimmediately,EVACUATEANDCALLTHEFIRE
DEPARTMENT.
NEVERPICKUPAFLAMINGPAN-youmaybeburned.b.
DONOTUSEWATER,includingwetdishclothsortowels-aviolentsteamexplosionmayresult.c.
UseafireextinguisherONLYif:d.
YouhaveaClassABCextinguisher,andyoualreadyknowhowtooperateit.•
Thefireissmallandcontainedintheareawhereitstarted.•
Thefiredepartmentisbeingcalled.•
Youcanfightthefirewithyourbacktoanexit.•
pr o d u C T sp eCifiCa T i o n s
Ge n e r a l Sp e c i f i c a t i o n S
ALL MODELS
Blower
600CFM(1200forunitswith2
blowers)withelectronicspeedcontrol
BlowerSpeeds 4
Lights 12Vac,20Whalogen
Filters Baffletype,dishwashersafe
Exhaust 8-inch
Finish 430stainlesssteel
Voltage
120Vac,60Hz(seebelowforcurrent
rating)
Circuit
Requirement
120Vac,15Ampgrounded,dedicated
circuit,minimum
MODEL SPECIFIC
SPECIFICATION
MODEL Blowers Lights Filters
Maximum
CurrentDraw
DHI361 1 4 1 3.75A
DHI421 1 4 1 3.75A
DHI482 2 4 2 6.75A
DHI542 2 6 2 7.10A
DHI602 2 6 3 7.10A
Di m e n S i o n S
*18”1/4onmodelsDHI482,DHI542andDHI602
**30”onmodelsDHI482,DHI542andDHI602
IMPORTANT:Theminimuminstalleddistancefromthe
hoodtothecooktopsurfacemustbenolessthan30
inches.Theminimumspecifieddistancemaybehigher
fortheparticularrangeorcooktopinuse.Checkthe
manufacturersspecificationsforthecooktoporrange.
36” (91.4 cm) - 42” (106.7 cm)
48” (121.9 cm) - 54” 137.2 cm)
60” (152.4 cm)
25 5/8”
(65.1 cm)**
15 ¾” (40.0 cm)
Chimney
12 9/16” (31.9 cm)
12 ½”
(31.8 cm)
15 ½”
(39.4 cm)*
28” (71.1 cm) to 36” (91.4 cm)
Tolerances:+1/16”,-0(+1.6mm,-0),
unlessotherwisestated
4
pr e p a r i n g f o r in s T a l l a T i o n
Ve r i f y t h e pa c k a G e co n t e n t S
Unpackthepartsboxandverifythatallrequired
componentshavebeenprovided.Ifanyitemismissingor
damaged,pleasecontactthedealerimmediately.Donot
installadamagedorincompleteappliance.
Hoodassemblywithfilter(s)
Chimneyassembly(2piece)
Mountingbracket
Blowerexhaustcowling(2blowerunitsonly)
Frameworkassembly(2piece)
Mountingandassemblyhardware
Useandcaremanual
Makesureyouhaveeverythingnecessaryforproper
installationbeforeproceeding.
A
B
C
D
E
F
G
A
B
C
D
E
F
G
5
pl a n n i n G t h e lo c a t i o n
Carefullycheckthelocationwherethehoodistobe•
installed.Thehoodshouldbeplacedforconvenient
access.Makecertainthatelectricalpowercanbe
providedintheselectedlocation.
Installtherangehoodandcookingappliance(s)sothat•
theycanberemovedifserviceisrequired.
Plantheinstallationsothatallminimumdimensions•
aremetorexceeded(seepage3).Dimensionsshown
provideminimumclearances,unlessotherwisenoted.
Preparing the Mounting Bracket Location
Themountingbracketmustbeattacheddirectlytothe•
studsintheceiling,ortoareinforcedmountingblock
securedtothestuds.Seebelowformountingbracket
holedimensions.
Attachthemountingbracketdirectlyabovethecenter•
ofthecooktop.
Attachthemountingbrackettothemountingsurfaces•
with#12screws(notsupplied).Thescrewsmustbeof
sufficientlengthtopenetrateintothewoodmounting
surfacesatleast11/2”(3.8cm).
Themountingsurfacemustbelevel.•
Allowclearanceinthecenterofthemountingbracket•
fortheexhaustducttopassthroughtheceiling
(8-inchesindiameter).
el e c t r i c a l po w e r Su p p l y
Electrical Specifications
Itistheowner’sresponsibilitytoensurethattheelectrical
connectionofthisapplianceisperformedbyaqualified
electrician.Theelectricalinstallation,includingminimum
supplywiresizeandgrounding,mustbeinaccordancewith
theNationalElectriccodeANSI/NFPA*(orlatestrevision)
andlocalcodesandordinances.
Connectthehoodtoa120Vac,60Hzdedicated,
grounded,circuitprotectedbya15Ampcircuitbreakeror
timedelayfuse.
*Acopyofthisstandardmaybeobtainedfrom:
NationalFireProtectionAssociation
1BatterymarchPark
Quincy,Massachusetts02269-9101
WARNING
Theelectricalservicetotherangehoodshouldbe•
installedonlybyalicensedelectrician.
Observeallgoverningcodesandordinancesduring•
planningandinstallation.Contactyourlocalbuilding
departmentforfurtherinformation.
DO NOT• usethemountinganchorsprovidedwiththe
unit.Theyarepartofastandardmountinghardware
packageprovidedwithmanyDacorhoods,butnot
suitableforusewiththismodel.
Therangehoodisheavy.Topreventpersonalinjury•
andpropertydamagecausedbythehoodcoming
loosefromtheceiling,mountthehoodmounting
bracketonlyasspecifiedbelow.
pr e p a r i n g f o r in s T a l l a T i o n
129/16”
(31.9cm)
61/8”
(15.6cm)
11”
(27.9cm)
6
pl a n t h e Du c t wo r k in S t a l l a t i o n
WARNING
Toreducetheriskoffireandtoproperlyexhaust•
air,besuretoductairoutsidethehouseorbuilding.
Donotventexhaustairintospaceswithinwallsor
ceilingsorintoattics,crawlspacesorgarages.
Tapeallductjointssecurely• topreventcombustion
by-products,smokeorodorsfromenteringthehome.
Doingsowillalsoimprovesystemefficiency.
Donotexhaustmorethanone• ventintoasingleduct.
Useonly• ductworkconstructedofmaterialsdeemed
acceptablebystate,municipalandlocalcodes.
Rangehoodsmayinterrupttheproperflowof•
smokeandcombustiongasesfromfurnaces,gas
waterheatersandfireplaces.Toavoiddrawing
lethalgasesintothehome,followthemanufactures
recommendationforthesedevicesandconsultNFPA
andASHRAErecommendations.
DO NOT• installanadditionalin-lineorexternal
blowertoincreasethelengthoftheductrun.Even
smalldifferencesbetweenblowerairflowratescan
greatlyreducetheairdrawbythehood.
Allductworkmaterials(includingscrewsandducttape)•
mustbepurchasedseparatelybythecustomer.When
planningnewductwork,alwayslookfortheshortest,
mostdirectroutetotheoutside.
Thehoodexhaustconnectstoan8-inchroundduct.•
Youcanincreasetheductsizeovertheductrunif
desired.Topreventabackdraft,neverdecreasethe
ductsizeovertherun.
Donotrelyonducttapealonetosealductjoints.•
Fastenallconnectionswithsheetmetalscrewsand
tapealljointswithducttape.Usesheetmetalscrews
asrequiretosupporttheductweight.
Topreventback-drafts,adamperattheductoutletmay•
alsoberequired.
Makesureductworkdoesnotinterferewithfloorjoists•
orwallstuds.
Calculating the Maximum Duct Run Length
Themaximumstraightductlengthforthehoodis100
feet.Foreachelbowandtransitionaddedtotheduct
work,acertainnumberoffeetmustbesubtractedfrom
themaximumstraightlengthtocompensateforwind
resistance.Todeterminethelengththeductworkcannot
exceed,subtractalloftheequivalentlengthsoftheelbows
andtransitionslistedbelowfrom100feet.
Duct Work Equivalent Lengths
DUCT PIECE SUBTRACT
90°elbow(8”Dia.) 7feet
45°elbow(8”Dia.) 3feet
31/4”x10”to8”round 4foot
Wallcapwithdamper 30feet
Roofcap 30feet
Duct Work Design Tips
Whereverpossible,reducethenumberoftransitions•
andturnstoasfewsharpanglesaspossible.Two
staggered45°anglesarebetterthanone90°.
Keepturnsasfarawayfromthehoodexhaustas•
possible,withasmuchspacebetweeneachbendas
possible.
Forbestperformance,useroundductinsteadof•
rectangular,especiallywhenelbowsarerequired.
Ifmultipleelbowsareused,trytokeepaminimumof•
24”(61cm)ofstraightductbetweenthem.
Avoid“S”or“backtoback”configurationsofadjacent•
elbows.
Inregionswheretheweathergetsextremelycold,•
thermalbreaks,suchasashortsectionofnon-metallic
duct,shouldbeusedtoavoidindoorheatloss.The
breakshouldbelocatedasclosetothepassthrough
pointtotheoutsideaspossible.
Donotuseflexiblemetalduct.•
Donot• useductworkthatissmallerincross-sectional
areathantherecommendedsizeduct(8”round).
pr e p a r i n g f o r in s T a l l a T i o n
7
in s T a l l a T i o n in s T r u C T i o n s
WARNING
Donotinstalltherangehoodunlesstheelectrical•
serviceprovidedmeetstherangehoodspecifications.
Observeallgoverningcodesandordinancesduring•
planningandinstallation.Contactyourlocalbuilding
departmentforfurtherinformation.
Aqualifiedtechnicianmustcompletetheinstallation•
ofthisbuilt-inappliance.Theownerisresponsibleto
makesurethehoodisproperlyinstalled.
Toavoidanelectricshockhazardandproperty•
damage,locateelectricwiresandwaterpipesand
avoiddrillinginthevicinity.
Therangehoodisheavy.Topreventpersonal•
injuryandpropertydamageinstallthehoodonlyas
specifiedbelow.Makesureallscrewsusedtomount
andassemblethehoodaretight.
el e c t r i c Se r V i c e in S t a l l a t i o n
The electrical connection box must be:
Connectedtoa120Vac,60Hzdedicated,grounded,•
circuitprotectedbya15Ampcircuitbreakerortime
delayfuse.
Locatedaminimumof17”(43.2cm)abovethebottom•
oftherangehood.
mo u n t i n G Br a c k e t in S t a l l a t i o n
Locatethemountingbracketandpositionitagainstthe1.
ceilingatthepreviouslydeterminedmountinglocation
(seepage5).
Usingapencil,markthefourmountingholelocations2.
ontheceiling.
Drillfour1/16”(1.6mm)pilotholesatthemounting3.
holelocations.
Attachthebracketusingfour#12screws(not4.
supplied).Makesurethescrewspenetrateintothe
woodmountingsurfaces11/2”(3.8cm).
aS S e m B l e t h e ho o D
WARNING
Liftingandhangingtherangehoodrequirestwo•
people.Donotattempttoliftthehoodwithout
assistance.
Placethehoodassemblyonasoftsurfacewiththe1.
bottomsidedownduringassemblytoavoiddamage.
Tipthehooduponit’ssideandremovethefilter(s)to2.
reduceweightandavoiddamage.
Insidetheexhaustoutlet(s)therearemetalorplastic3.
damperflaps.Theflapsclosetohelppreventback-
draftswhenthebloweristurnedoff.Makesureallthe
flapsopenandclosefreelybeforeproceeding.Remove
anyshippingtapethatmaybepresent.
Removethetapethatholdsthewiringinplaceontop4.
ofthehoodduringshipment.
Onmodelswithtwoblowers:Puttheexhaustcowling5.
overthebloweroutletsonthetopofthehood.Fasten
thecowlinginplacewith14machinescrews.
8
Separatethebottomframeworkpiecefromthetop6.
frameworkpiece.Thetopframeworkpiecehas5-inch
slotsonthethesides.Thebottompiecehasaseriesof
holesonthesides.
Positionthebottomframeworkpieceontopofthe7.
hood.Slidethestudsonthetopofthehoodintothe
holesonthebottomoftheframeworkpiece.Thecut-
outsforthewiringallowthebottomframeworkpiece
tofitononlyoneway.Ifitdoesnotfitproperly,turnit
180°sothatthecut-outslineup.Makesureallwiringis
tuckedinsidetheframeworkpieceandarenotpinched.
Useeightprovidedlockwashersandnutstosecurethe8.
bottomframeworkpiecetothetopofthehood.
in s T a l l a T i o n in s T r u C T i o n s
Attachthehoodjunctionboxtotherimofthebottom9.
frameworkpieceusingtwomachinescrewsasshown.
Attachtheexternalmotorterminalblocktotherimof10.
thebottomframeworkpieceusingtwomachinescrews
asshown.Itmountsontheoppositesideofthehood
junctionbox.
HOOD
JUNCTION
BOX
ho o D aS S e m B l y (c o n t )
EXTERNAL
MOTOR
TERMINAL
BLOCK
FRAMEWORK
BOTTOM
HOOD
9
Determinethe11. required framework height.Todeter-
minetherequiredframeworkheight:
Putthetopframeworkpieceoverthebottomframework12.
piece.Themountingslotsonthetoppiecemustbeup.
Usefourmachinescrewstofastenthetoppieceto13.
thebottompiece.Thetotalheightofthetwopieces
togethermustequaltherequiredframeworkheight
determinedabove.
Removetheprotectiveplasticcoveringfromboth14.
piecesofthechimneyassembly.Donotremovethe
protectivetapestripsfromtheinside.Theyprotectthe
telescopingpiecesfromscratchingduringinstallation.
Carefullyslidebothsectionstogethersothatonlythe15.
ventsonthetopsectionshow.
Holdthechimneyverticallywiththeventsup.16.
Carefullyputthechimneyoverthetopofthe17.
framework,takingcarenottoscratchthesurfaces.
MakesuretheDacorlogofacesthesamesideasthe
controlpanel.
Makesureanywiresaretuckedinbehindthechimney18.
andarenotpinched.
in s T a l l a T i o n in s T r u C T i o n s
Measurethedistancefromtheceilingtothe•
cooktop.
Subtracttheheightatwhichthehoodwillbe•
mounted(30”minimum)andthehoodthickness
(121/2”)fromthedistancemeasured.
CHIMNEY
HOOD
TOP
FRAMEWORK
BOTTOM
FRAMEWORK
MOUNTING
SLOTS
10
in s T a l l a T i o n in s T r u C T i o n s
in S t a l l t h e Du c t wo r k
WARNING
Donotusescrewstoattachtheductworktothe•
hoodexhaustoutlet.Useducttapeonly.Screwsmay
preventthedamperflapsonthetopofthehoodfrom
opening.
Installtheductworksystem.Liftthechimneyup•
andreachinsidetheframeworktoaccessthehood
exhaust.Attachtheducttothehoodexhaustwithduct
tapealone.Usesheetmetalscrews(notprovided)and
ducttapeonalltheremainingductsystemjoints.
DUCT WORK
THROUGH CEILING,
CONNECTS TO
EXHAUST OUTLET
INSIDE FRAMEWORK
ha n G i n G t h e ra n G e ho o D
WARNING
Topreventpersonalinjury,donotrelyonthe•
mountingspringstoholdthehoodassemblyinplace
ontheceiling.Oncethehoodishookedinplace
IMMEDIATELYsecuretheframeworktothemounting
bracketasdescribedbelow.
Beforeraisingthehoodintoposition,liftitupandorient1.
itsothatthecontrolpanelfacesthesamedirectionas
thefrontofthecooktoporrange.
Liftthehoodassemblyuponbothsidesandslipthe2.
endoftheframeworkoverthemountingbracket.Push
upuntilallfourmountingspringsprotrudeoutofthe
mountingslotsonthetopoftheframework.
Attachtheframeworktothemountingbracketusing3.
fourself-tappingscrews.
MOUNTING
SPRINGS
11
in s T a l l a T i o n in s T r u C T i o n s
fi n a l el e c t r i c a l in S t a l l a t i o n
WARNINGS
Toavoidelectricalshockorfirehazard,makesure•
thepowersupplyatthefuseorjunctionboxisturned
offbeforeproceedingwithfinalelectricalinstallation.
Improperconnectionofthehoodelectricalwiringmay•
createanelectricshockorfirehazardandmayresult
indamagetothehoodselectricalsystem.
Donotgroundthehoodtotheneutral(white)power•
supplywire.Connectthehoodgroundwiretoa
separate,properlygroundedwireinstalledbya
licensedelectrician.
Connect the house power supply wires to the wires
coming out of the hood junction box, inside the
chimney:
Connectthewhitewirefromthehoodtotheneutral1.
(white)powersupplywire.
Connecttheblackwirefromthehoodtothehot(black)2.
powersupplywire.
Connectthegreenandyellowwirefromthehoodto3.
thehouseground(green)wirefromthejunctionbox.
BLACK TO BLACK
YELLOW/GREEN
TO GREEN
WHITE TO WHITE
fi n a l ch i m n e y aS S e m B l y
IMPORTANT:Becarefulnottopinchtheelectricalwires
whileassemblingthechimney.
Movethechimneyuptowardtheceiling.Lineupthe1.
holesonthesideofthechimney,abovethevents,with
theholesonthesideofthemountingbracket.
Attachthesidesofthechimneytothebracketusing2.
twomachinescrews,oneoneachside.
Carefully,slidethebottomportionofthechimneydown3.
untilitrestsonthetopoftherangehood.
Reinstalltherangehoodfilter(s)beforeoperation.
12
in s T a l l a T i o n in s T r u C T i o n s
in S t a l l a t i o n ch e c k l i S t
WARNING
Toensureasafeandproperinstallation,thefollowing•
checklistshouldbecompletedbytheinstallerto
ensurethatnopartoftheinstallationhasbeen
overlooked.
Properinstallationistheresponsibilityofthe•
homeowner.Theimportanceofproperinstallationof
yourDacorrangehoodcannotbeoveremphasized.
Isthemountingbracketproperlyattachedtotheceiling
accordingtotheinstructionsonpage7?
Isthehoodproperlysecuredtothemountingbracket
withthemachinescrews(seepage10)?
Istheductworkcompletelyinstalled?Arealljoints
attachedwithsheetmetalscrewsandwrappedwith
ducttape(seepages6and10)?
Istherangehoodwiredandgroundedaccordingto
theseinstructionsandinaccordancewithallapplicable
electricalcodes(seepage11)?
Arethefiltersproperlyinstalledaccordingtotheuse
andcaremanual?
Hasproperoperation beenverified?
Haveanyproblemsbeennotedonthewarrantycard
orduringtheon-linewarrantyactivation?Hasthe
warrantybeenactivatedon-lineorthewarrantycard
filledoutcompletelyandmailed?
Ve r i f y i n G pr o p e r op e r a t i o n
Turnonpoweratthejunctionorfusebox.1.
Ifthecontrolpanelisnotlit,removethefilter(s)and2.
turnonthemainpowerswitchlocatedbehindthefilters
ontheundersideofthehood.Replacethefilter(s).
Touchthelightkey.Verifythatallthelightscomeon.3.
Touchthelightkeyagaintoturnthelightsoff.4.
Touchtheblower5. “+”keyonceandrelease.Verifythat
onelightisshowingontheblowerspeedindicatorand
thattheblowerisonatlowspeed.
Touchandreleasetheblower6. “+”repeatedly,three
times.Verifythatwitheachtouchofthekeythenumber
oflightsontheblowerspeedindicatorincreasesand
thattheblowerspeedincreases.
Touchandholdtheblower7. “-”keyuntiltheblower
turnsoff.
If the hood fails to operate properly:
Verifythatpowerissuppliedtothehood.•
Checktheelectricalconnectionstoensurethatthe•
installationhasbeencompletedcorrectly.
Repeattheabovetest.•
Iftheappliancestilldoesnotwork,contactan•
authorizedDacorservicecompanyat(800)793-0093.
Donotattempttorepairtheapplianceyourself.Dacor
isnotresponsibleforservicerequiredtocorrectafaulty
installation.
Dacor 1440 Bridge Gate Drive, Diamond Bar, CA 91765 Tel: (800) 793-0093 FAX: (626) 403-3130 www.Dacor.com
/