Enterasys Networks DFE-Platinum Series User manual

Category
Networking
Type
User manual

This manual is also suitable for

8.5x11-inch cover with bleed on 4 sides
Enterasys Matrix
TM
DFE-Diamond Series
Hardware Installation Guide
7KR4297-02
7KR4297-04
P/N 9034365-01
i
Notice
Enterasys Networksreservestherighttomakechangesinspecificationsandotherinformationcontainedinthisdocumentand
itswebsitewithoutpriornotice.ThereadershouldinallcasesconsultEnterasys Networkstodeterminewhetheranysuch
changeshavebeenmade.
Thehardware,firmware,orsoftwaredescribedinthisdocumentissubject
tochangewithoutnotice.
INNOEVENTSHALLENTERASYS NETWORKSBELIABLEFORANYINCIDENTAL,INDIRECT,SPECIAL,OR
CONSEQUENTIALDAMAGESWHATSOEVER(INCLUDINGBUTNOTLIMITEDTOLOSTPROFITS)ARISINGOUTOF
ORRELATEDTOTHISDOCUMENT,WEBSITE,ORTHEINFORMATIONCONTAINEDINTHEM,EVENIF
ENTERASYS NETWORKSHASBEENADVISEDOF,KNEW
OF,ORSHOULDHAVEKNOWNOF,THEPOSSIBILITYOF
SUCHDAMAGES.
Enterasys Networks, Inc.
50MinutemanRoad
Andover,MA01810
© 2008Enterasys Networks, Inc.Allrightsreserved.
PartNumber: 903436501 February 2008
ENTERASYS,ENTERASYS NETWORKS,ENTERASYSMATRIX,ENTERASYSNETSIGHT,LANVIEW,WEBVIEW,andany
logosassociatedtherewith,aretrademarksorregisteredtrademarksofEnterasys Networks, Inc.,intheUnitedStatesandother
countries.
Allotherproductnamesmentionedinthismanualmaybetrademarksorregisteredtrademarksoftheirrespectivecompanies.
DocumentationURL:http://www.enterasys.com/support/manuals
DocumentacionURL:http://www.enterasys.com/support/manuals
DokumentationimInternet:http://www.enterasys.com/support/manuals
Electrical Hazard: Only qualified personnel should perform installation procedures.
Riesgo Electrico: Solamente personal calificado debe realizar procedimientos de instalacion.
Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und qualifiziertes Personal
vorgenommen werden.
ii
Regulatory Compliance Information
Federal Communications Commission (FCC) Notice
ThisdevicecomplieswithPart15oftheFCCrules.Operationissubjecttothefollowingtwoconditions:(1)thisdevicemaynot
causeharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycause
undesiredoperation.
NOTE: Thisequipmenthasbeentestedandfoundtocomply
withthelimitsforaclassAdigitaldevice,pursuanttoPart15of
theFCCrules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferencewhentheequipmentis
operatedinacommercialenvironment.Thisequipmentuses,generates,andcanradiateradiofrequencyenergyandifnot
installedinaccordancewiththeoperatorsmanual,maycauseharmfulinterferencetoradiocommunications.Operationofthis
equipmentinaresidentialareaislikelytocauseinterferenceinwhichcasetheuserwillberequiredtocorrecttheinterference
athisownexpense.
WARNING: Changesormodificationsmadetothisdevicewhich
arenotexpresslyapprovedbythepartyresponsiblefor
compliancecouldvoidtheusersauthoritytooperatetheequipment.
Industry Canada Notice
ThisdigitalapparatusdoesnotexceedtheclassAlimitsforradionoiseemissionsfromdigitalapparatussetoutintheRadio
InterferenceRegulationsoftheCanadianDepartmentofCommunications.
Leprésentappareilnumériquen’émetpasdebruitsradioélectriquesdépassantleslimitesapplicablesauxappareils
numériquesdelaclassAprescrites
dansleRèglementsurlebrouillageradioélectriqueédictéparleministèredes
CommunicationsduCanada.
Class A ITE Notice
WARNING: ThisisaClassAproduct.Inadomesticenvironmentthisproductmaycauseradiointerferenceinwhichcasethe
usermayberequiredtotakeadequatemeasures.
Clase A. Aviso de ITE
ADVERTENCIA:EsteesunproductodeClaseA.Enunambientedomésticoesteproductopuedecausarinterferenciaderadio
encuyocasopuedeserrequeridotomarmedidasadecuadas.
Klasse A ITE Anmerkung
WARNHINWEIS:DiesesProduktzähltzurKlasseA(Industriebereich).InWohnbereichenkanneshierdurchzu
Funkstörungenkommen,dahersolltenangemesseneVorkehrungenzumSchutzgetroffenwerden.
Product Safety
Thisproductcomplieswiththefollowing:UL60950,CSAC22.2No.60950,2006/95/EC,EN60950,IEC60950,EN 60825,
21 CFR 1040.10.
Seguridad del Producto
ElproductodeEnterasyscumpleconlosiguiente:UL60950,CSAC22.2No.60950,2006/95/EC,EN 60950,IEC 60950,EN 60825,
21 CFR1040.10.
Produktsicherheit
DiesesProduktentsprichtdenfolgendenRichtlinien:UL60950,CSAC22.2No.60950,2006/95/EC,EN60950,IEC60950,
EN 60825,21CFR1040.10.
iii
Electromagnetic Compatibility (EMC)
Thisproductcomplieswiththefollowing:47CFRParts2and15,CSAC108.8,2004/108/EC,EN55022,EN6100032,
EN 6100033,EN55024,AS/NZSCISPR22,VCCIV3.
Compatibilidad Electromágnetica (EMC)
EsteproductodeEnterasyscumpleconlosiguiente:47CFRPartes2y15,CSAC108.8,2004/108/EC,EN55022,EN 55024,
EN 6100032,EN6100033,AS/NZSCISPR22,VCCIV3.
Elektro- magnetische Kompatibilität ( EMC )
DiesesProduktentsprichtdenfolgendenRichtlinien:47CFRParts2and15,CSAC108.8,2004/108/EC,EN55022,EN 6100032,
EN6100033,EN55024,AS/NZSCISPR22,VCCIV3.
Hazardous Substances
ThisproductcomplieswiththerequirementsofEuropeanDirective,2002/95/EC,RestrictionofHazardousSubstances(RoHS)
inElectricalandElectronicEquipment.
European Waste Electrical and Electronic Equipment (WEEE) Notice
InaccordancewithDirective2002/96/ECoftheEuropeanParliamentonwasteelectricalandelectronicequipment(WEEE):
1. Thesymbolaboveindicatesthatseparatecollectionofelectricalandelectronicequipmentisrequiredandthatthisproduct
wasplacedontheEuropeanmarketafterAugust13,2005,thedateofenforcementforDirective2002/96/EC.
2. When
thisproducthasreachedtheendofitsserviceablelife,itcannotbedisposedofasunsortedmunicipalwaste.Itmust
becollectedandtreatedseparately.
3. IthasbeendeterminedbytheEuropeanParliamentthattherearepotentialnegativeeffectsontheenvironmentandhuman
healthasaresultofthe
presenceofhazardoussubstancesinelectricalandelectronicequipment.
4. Itistheusers’responsibilitytoutilizetheavailablecollectionsystemtoensureWEEEisproperlytreated.
Forinformationabouttheavailablecollectionsystem,pleasegotowww.enterasys.com/support orcontactEnterasys
CustomerSupportat35361705586(Ireland).
iv
ѻ
ѻક䇈ᯢк䰘ӊ
Supplement to Product Instructions
᳝↦᳝ᆇ⠽䋼៪ܗ㋴(Hazardous Substance)
䚼ӊৡ⿄
(Parts)
䪙
3E
∲
+J
䬝
&G
݁Ӌ䫀
&U

໮⒈㘨㣃
3%%
໮⒈Ѡ㣃䝮
3%'(
䞥ሲ䚼ӊ
(Metal Parts)
ƻ h ƻ ƻ
⬉䏃῵ഫ
(Circuit Modules)
ƻ h ƻ ƻ
⬉㓚ঞ⬉㓚㒘ӊ
(Cables & Cable Assemblies)
ƻ h ƻ ƻ
ล᭭੠㘮ড়⠽䚼ӊ
(Plastic and Polymeric parts)
ƻƻ ƻ ƻ ƻ h
⬉䏃ᓔ݇
(Circuit Breakers)
ƻƻ h h ƻ ƻ
ƻ˖ 㸼⼎䆹᳝↦᳝ᆇ⠽䋼೼䆹䚼ӊ᠔᳝ഛ䋼ᴤ᭭Ёⱘ৿䞣ഛ೼ SJ/T 11363-2006 ᷛޚ㾘ᅮⱘ䰤䞣㽕∖ҹϟDŽ
Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is
below the relevant threshold of the SJ/T 11363-2006 standard.
h˖ 㸼⼎䆹᳝↦᳝ᆇ⠽䋼㟇ᇥ೼䆹䚼ӊⱘᶤϔഛ䋼ᴤ᭭Ёⱘ৿䞣䍙ߎSJ/T 11363-2006 ᷛޚ㾘ᅮⱘ䰤䞣㽕∖DŽ
Indicates that the concentration of the hazardous substance of at least one of all homogeneous
materials in the parts is above the relevant threshold of the SJ/T 11363-2006 standard.
ᇍ䫔ଂП᮹ⱘ᠔ଂѻકᴀ㸼ᰒ⼎
߃߯կᑨ䫒ⱘ⬉ᄤֵᙃѻકৃ㛑ࣙ৿䖭ѯ⠽䋼DŽ⊼ᛣ೼᠔ଂѻકЁৃ㛑Ӯгৃ㛑ϡӮ৿᳝᠔᳝᠔߫ⱘ䚼ӊDŽ
This table shows where these substances may be found in the supply chain of Enterasys’ electronic
information products, as of the date of sale of the enclosed product. Note that some of the component types
listed above may or may not be a part of the enclosed product.
50
ℸ⦃ֱՓ⫼ᳳ䰤া䗖⫼Ѣѻકᰃ೼ѻક᠟ݠЁ᠔㾘ᅮⱘᴵӊϟᎹ԰
The Environmentally Friendly Use Period (EFUP) for all enclosed products and their parts
are per the symbol shown here, unless otherwise marked. Certain parts may have a
different EFUP (for example, battery modules) and so are marked to reflect such. The
Environmentally Friendly Use Period is valid only when the product is operated under the
conditions defined in the product manual.
䰸䴲঺໪⡍߿ⱘᷛ⊼ℸᷛᖫЎ䩜ᇍ᠔⍝ঞѻકⱘ⦃ֱՓ⫼ᳳᷛᖫᶤѯ䳊䚼ӊӮ
᳝ϔϾϡৠⱘ⦃ֱՓ⫼ᳳ՟བ⬉∴ऩܗ῵ഫ䌈೼݊ѻકϞ
v
VCCI Notice
ThisisaclassAproductbasedonthestandardoftheVoluntaryControlCouncilforInterferencebyInformationTechnology
Equipment(VCCI).Ifthisequipmentisusedinadomesticenvironment,radiodisturbancemayarise.Whensuchtrouble
occurs,theusermayberequiredtotakecorrectiveactions.
BSMI EMC Statement — Taiwan
ThisisaclassAproduct.Inadomesticenvironmentthisproductmaycauseradiointerferenceinwhichcasetheusermaybe
requiredtotakeadequatemeasures.
Safety Information
Class 1 Laser Transceivers
The single mode interface modules use Class 1 laser transceivers.
Read the following safety information before installing or operating these modules.
TheClass1lasertransceiversuseanopticalfeedbacklooptomaintainClass1operationlimits.Thiscontrolloopeliminatesthe
needformaintenancechecksoradjustments.Theoutputisfactoryset,anddoesnotallowanyuseradjustment.Class1Laser
transceiverscomplywiththefollowingsafetystandards:
•21
CFR1040.10and1040.11U.S.DepartmentofHealthandHumanServices(FDA).
•IECPublication825(InternationalElectrotechnicalCommission).
CENELECEN60825(EuropeanCommitteeforElectrotechnicalStandardization).
Whenoperatingwithintheirperformancelimitations,lasertransceiveroutputmeetstheClass1accessibleemissionlimitofall
threestandards.Class1levelsoflaserradiation
arenotconsideredhazardous.
Whentheconnectorisinplace,alllaserradiationremainswithinthefiber.Themaximumamountofradiantpowerexitingthe
fiber(undernormalconditions)is‐12.6dBmor55x10
6
watts.
Removingtheopticalconnectorfromthetransceiverallowslaserradiationtoemitdirectlyfromtheopticalport.Themaximum
radiancefromtheopticalport(underworstcaseconditions)is0.8Wcm
2
or8x10
3
Wm
2
sr1.
Donotuseopticalinstrumentstoviewthelaseroutput.Theuseofopticalinstrumentstoviewlaseroutputincreaseseye
hazard.Whenviewingtheoutputopticalport,powermustberemovedfromthenetworkadapter.
vi
Declaration of Conformity
ApplicationofCouncilDirective(s): 2004/108/EC
2006/95/EC
ManufacturersName: Enterasys Networks, Inc.
ManufacturersAddress: 50MinutemanRoad
Andover,MA01810
USA
EuropeanRepresentativeAddress: Enterasys Networks,Ltd.
NexusHouse,NewburyBusinessPark
LondonRoad,Newbury
BerkshireRG142PZ,England
ConformancetoDirective(s)/ProductStandards: ECDirective2004/108/EC
EN55022
EN6100032
EN6100033
EN55024
ECDirective2006/95/EC
EN60950
EN60825
Equipment
Type/Environment: NetworkingEquipment,foruseinaCommercial
orLightIndustrialEnvironment.
Enterasys Networks, Inc.declaresthattheequipmentpackagedwiththisnoticeconformstotheabovedirectives.
Enterasys Networks, Inc. Firmware License Agreement
BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT,
CAREFULLY READ THIS LICENSE AGREEMENT.
Thisdocumentisanagreement(“Agreement”)betweentheenduser(“You”)andEnterasysNetworks,Inc.,onbehalfofitself
anditsAffiliates(ashereinafterdefined)(“Enterasys”)thatsetsforthYourrightsandobligationswithrespecttotheEnterasys
softwareprogram/firmware(includinganyaccompanyingdocumentation,hardwareormedia)(“Program”)inthepackage
andprevailsoveranyadditional,conflictingorinconsistenttermsandconditionsappearingonanypurchaseorderorother
documentsubmittedbyYou.Affiliate”meansanyperson,partnership,corporation,limitedliabilitycompany,otherformof
enterprisethatdirectlyorindirectlythroughoneormoreintermediaries,controls,oriscontrolledby,or
isundercommon
controlwiththepartyspecified.ThisAgreementconstitutestheentireunderstandingbetweentheparties,withrespecttothe
subjectmatterofthisAgreement.TheProgrammaybecontainedinfirmware,chipsorothermedia.
BYINSTALLINGOROTHERWISEUSINGTHEPROGRAM,YOUREPRESENTTHATYOUAREAUTHORIZEDTO
ACCEPT
THESETERMSONBEHALFOFTHEENDUSER(IFTHEENDUSERISANENTITYONWHOSEBEHALFYOUARE
AUTHORIZEDTOACT,“YOU”AND“YOUR”SHALLBEDEEMEDTOREFERTOSUCHENTITY)ANDTHATYOU
AGREETHATYOUAREBOUNDBYTHETERMSOFTHISAGREEMENT,WHICHINCLUDES,
AMONGOTHER
PROVISIONS,THELICENSE,THEDISCLAIMEROFWARRANTYANDTHELIMITATIONOFLIABILITY.IFYOUDONOT
AGREETOTHETERMSOFTHISAGREEMENTORARENOTAUTHORIZEDTOENTERINTOTHISAGREEMENT,
ENTERASYSISUNWILLINGTOLICENSETHEPROGRAMTOYOUANDYOUAGREETORETURNTHEUNOPENED
PRODUCTTOENTERASYSORYOURDEALER,IFANY,WITHINTEN(10)DAYSFOLLOWINGTHEDATEOFRECEIPT
FORAFULLREFUND.
IFYOUHAVEANYQUESTIONSABOUTTHISAGREEMENT,CONTACTENTERASYSNETWORKS,LEGAL
DEPARTMENTAT(978)6841000.
YouandEnterasysagreeasfollows:
1. LICENSE. Youhavethenonexclusiveandnon
transferablerighttouseonlytheone(1)copyoftheProgramprovidedin
thispackagesubjecttothetermsandconditionsofthisAgreement.
vii
2. RESTRICTIONS. ExceptasotherwiseauthorizedinwritingbyEnterasys,Youmaynot,normayYoupermitanythird
partyto:
(a) Reverseengineer,decompile,disassembleormodifytheProgram,inwholeorinpart,includingforreasonsoferror
correctionorinteroperability,excepttotheextentexpresslypermittedbyapplicablelawand
totheextenttheparties
shallnotbepermittedbythatapplicablelaw,suchrightsareexpresslyexcluded.Informationnecessarytoachieve
interoperabilityorcorrecterrorsisavailablefromEnterasysuponrequestanduponpaymentofEnterasys’applicable
fee.
(b) IncorporatethePrograminwholeorinpart,inanyotherproduct
orcreatederivativeworksbasedontheProgram,in
wholeorinpart.
(c) Publish,disclose,copyreproduceortransmittheProgram,inwholeorinpart.
(d) Assign,sell,license,sublicense,rent,lease,encumberbywayofsecurityinterest,pledgeorotherwisetransferthe
Program,inwholeorinpart.
(e) Removeanycopyright,
trademark,proprietaryrights,disclaimerorwarningnoticeincludedonorembeddedinany
partoftheProgram.
3. APPLICABLELAW. ThisAgreementshallbeinterpretedandgovernedunderthelawsandinthestateandfederalcourts
oftheCommonwealthofMassachusettswithoutregardtoitsconflictsoflawsprovisions.Youaccept
thepersonaljurisdiction
andvenueoftheCommonwealthofMassachusettscourts.Noneofthe1980UnitedNationsConventionontheLimitationPeriod
intheInternationalSaleofGoods,andtheUniformComputerInformationTransactionsActshallapplytothisAgreement.
4. EXPORTRESTRICTIONS. YouunderstandthatEnterasysanditsAffiliatesaresubject
toregulationbyagenciesofthe
U.S.Government,includingtheU.S.DepartmentofCommerce,whichprohibitexportordiversionofcertaintechnicalproducts
tocertaincountries,unlessalicensetoexporttheproductisobtainedfromtheU.S.Governmentoranexceptionfromobtaining
suchlicensemayberelieduponby
theexportingparty.
IftheProgramisexportedfromtheUnitedStatespursuanttotheLicenseExceptionCIVundertheU.S.Export
AdministrationRegulations,YouagreethatYouareacivilenduseroftheProgramandagreethatYouwillusetheProgramfor
civilendusesonlyandnot
formilitarypurposes.
IftheProgramisexportedfromtheUnitedStatespursuanttotheLicenseExceptionTSRundertheU.S.Export
AdministrationRegulations,inadditiontotherestrictionontransfersetforthinSection1or2ofthisAgreement,Youagreenot
to(i)reexportorreleasetheProgram,
thesourcecodefortheProgramortechnologytoanationalofacountryinCountry
GroupsD:1orE:2(Albania,Armenia,Azerbaijan,Belarus,Cambodia,Cuba,Georgia,Iraq,Kazakhstan,Laos,Libya,Macau,
Moldova,Mongolia,NorthKorea,thePeople’ sRepublicofChina,Russia,Tajikistan,Turkmenistan,Ukraine,Uzbekistan,
Vietnam,orsuchother
countriesasmaybedesignatedbytheUnitedStatesGovernment),(ii)exporttoCountryGroupsD:1or
E:2(asdefinedherein)thedirectproductoftheProgramorthetechnology,ifsuchforeignproduceddirectproductissubjectto
nationalsecuritycontrolsasidentifiedontheU.S.CommerceControlList,or
(iii)ifthedirectproductofthetechnologyisa
completeplantoranymajorcomponentofaplant,exporttoCountryGroupsD:1orE:2thedirectproductoftheplantora
majorcomponentthereof,ifsuchforeignproduceddirectproductissubjecttonationalsecuritycontrolsas
identifiedonthe
U.S.CommerceControlListorissubjecttoStateDepartmentcontrolsundertheU.S.MunitionsList.
5. UNITEDSTATESGOVERNMENTRESTRICTEDRIGHTS. TheenclosedProgram(i)wasdevelopedsolelyatprivate
expense;(ii)contains“restrictedcomputersoftware”submittedwithrestrictedrightsinaccordancewithsection52.22719(a)
through
(d)oftheCommercialComputerSoftwareRestrictedRightsClauseanditssuccessors,and(iii)inallrespectsis
proprietarydatabelongingtoEnterasysand/oritssuppliers.ForDepartmentofDefenseunits,theProgramisconsidered
commercialcomputersoftwareinaccordancewithDFARSsection227.72023anditssuccessors,anduse,duplication,or
disclosurebytheU.S.Governmentissubjecttorestrictionssetforthherein.
6. DISCLAIMEROFWARRANTY. EXCEPTFORTHOSEWARRANTIESEXPRESSLYPROVIDEDTOYOUINWRITING
BYENTERASYS,ENTERASYSDISCLAIMSALLWARRANTIES,EITHEREXPRESSORIMPLIED,INCLUDINGBUTNOT
LIMITEDTOIMPLIEDWARRANTIESOFMERCHANTABILITY,SATISFACTORYQUALITY,FITNESSFORAPARTICULAR
PURPOSE,TITLEANDNONINFRINGEMENTWITHRESPECTTOTHEPROGRAM.IFIMPLIEDWARRANTIESMAYNOT
BEDISCLAIMEDBYAPPLICABLELAW,THENANYIMPLIEDWARRANTIESARELIMITEDINDURATIONTOTHIRTY
(30)DAYSAFTERDELIVERYOFTHEPROGRAMTOYOU.
viii
7. LIMITATIONOFLIABILITY. INNOEVENTSHALLENTERASYSORITSSUPPLIERSBELIABLEFORANY
DAMAGESWHATSOEVER(INCLUDING,WITHOUTLIMITATION,DAMAGESFORLOSSOFBUSINESS,PROFITS,
BUSINESSINTERRUPTION,LOSSOFBUSINESSINFORMATION,SPECIAL,INCIDENTAL,CONSEQUENTIAL,OR
RELIANCEDAMAGES,OROTHERLOSS)ARISINGOUTOFTHEUSEORINABILITYTOUSETHE
PROGRAM,EVENIF
ENTERASYSHASBEENADVISEDOFTHEPOSSIBILITYOFSUCHDAMAGES.THISFOREGOINGLIMITATIONSHALL
APPLYREGARDLESSOFTHECAUSEOFACTIONUNDERWHICHDAMAGESARESOUGHT.
THECUMULATI VELIABILITYOFENTERASYSTOYOUFORALLCLAIMSRELATINGTOTHEPROGRAM,IN
CONTRACT,TORTOROTHERWISE,SHALLNOTEXCEED
THETOTALAMOUNTOFFEESPAIDTOENTERASYSBY
YOUFORTHERIGHTSGRANTEDHEREIN.
8. AUDITRIGHTS. YouherebyacknowledgethattheintellectualpropertyrightsassociatedwiththeProgramareofcritical
valuetoEnterasys,and,accordingly,Youherebyagreetomaintaincompletebooks,recordsandaccountsshowing(i)license
fees
dueandpaid,and(ii)theuse,copyinganddeploymentoftheProgram.YoualsogranttoEnterasysanditsauthorized
representatives,uponreasonablenotice,therighttoauditandexamineduringYournormalbusinesshours,Yourbooks,records,
accountsandhardwaredevicesuponwhichtheProgrammaybedeployed
toverifycompliancewiththisAgreement,including
theverificationofthelicensefeesdueandpaidEnterasysandtheuse,copyinganddeploymentoftheProgram.Enterasys’right
ofexaminationshallbeexercisedreasonably,ingoodfaithandinamannercalculatedtonotunreasonablyinterferewithYour
business.Inthe
eventsuchauditdiscoversnoncompliancewiththisAgreement,includingcopiesoftheProgrammade,used
ordeployedinbreachofthisAgreement,YoushallpromptlypaytoEnterasystheappropriatelicensefees.Enterasysreserves
theright,tobeexercisedinitssolediscretionandwithoutpriornotice,toterminate
thislicense,effectiveimmediately,forfailure
tocomplywiththisAgreement.Uponanysuchtermination,YoushallimmediatelyceasealluseoftheProgramandshallreturn
toEnterasystheProgramandallcopiesoftheProgram.
9. OWNERSHIP. Thisisalicenseagreementandnotanagreementforsale.Youacknowledge
andagreethattheProgram
constitutestradesecretsand/orcopyrightedmaterialofEnterasysand/oritssuppliers.Youagreetoimplementreasonable
securitymeasurestoprotectsuchtradesecretsandcopyrightedmaterial.Allright,titleandinterestinandtotheProgramshall
remainwithEnterasysand/oritssuppliers.Allrightsnot
specificallygrantedtoYoushallbereservedtoEnterasys.
10. ENFORCEMENT. YouacknowledgeandagreethatanybreachofSections2,4,or9ofthisAgreementbyYoumaycause
Enterasysirreparabledamageforwhichrecoveryofmoneydamageswouldbeinadequate,andthatEnterasysmaybeentitled
toseektimely
injunctiverelieftoprotectEnterasys’rightsunderthisAgreementinadditiontoanyandallremediesavailableat
law.
11. ASSIGNMENT. Youmaynotassign,transferorsublicensethisAgreementoranyofYourrightsorobligationsunderthis
Agreement,exceptthatYoumayassignthisAgreementtoanypersonorentity
whichacquiressubstantiallyallofYourstock
assets.EnterasysmayassignthisAgreementinitssolediscretion.ThisAgreementshallbebindinguponandinuretothebenefit
oftheparties,theirlegalrepresentatives,permittedtransferees,successorsandassignsaspermittedbythisAgreement.Any
attemptedassignment,transferorsublicense
inviolationofthetermsofthisAgreementshallbevoidandabreachofthis
Agreement.
12. WAIVER. AwaiverbyEnterasysofabreachofanyofthetermsandconditionsofthisAgreementmustbeinwritingand
willnotbeconstruedasawaiverofanysubsequentbreach
ofsuchtermorcondition.Enterasys’failuretoenforceatermupon
YourbreachofsuchtermshallnotbeconstruedasawaiverofYourbreachorpreventenforcementonanyotheroccasion.
13. SEVERABILITY. IntheeventanyprovisionofthisAgreementisfoundtobeinvalid,illegalorunenforceable,
thevalidity,
legalityandenforceabilityofanyoftheremainingprovisionsshallnotinanywaybeaffectedorimpairedthereby,andthat
provisionshallbereformed,construedandenforcedtothemaximumextentpermissible.Anysuchinvalidity,illegality,or
unenforceabilityinanyjurisdictionshallnotinvalidateorrenderillegalor
unenforceablesuchprovisioninanyother
jurisdiction.
14. TERMINATION. EnterasysmayterminatethisAgreementimmediatelyuponYourbreachofanyofthetermsand
conditionsofthisAgreement.Uponanysuchtermination,YoushallimmediatelyceasealluseoftheProgramandshallreturn
toEnterasystheProgramandallcopiesof
theProgram.
ix
Contents
About This Guide
Who Should Use This Guide .............................................................................................................................xi
How to Use This Guide ..................................................................................................................................... xii
Related Documents .......................................................................................................................................... xii
Document Conventions ................................................................................................................................... xiii
Commonly Used Acronyms ............................................................................................................................. xiii
Getting Help ..................................................................................................................................................... xiv
Chapter 1: Introduction
Overview of Matrix DFE-Diamond Module Capabilities .................................................................................. 1-1
The DFE-Diamond 7KR4297-02 and 7KR4297-04 Modules .......................................................................... 1-2
7KR4297-02 ............................................................................................................................................. 1-2
7KR4297-04 ............................................................................................................................................. 1-2
XFP 10GBASE-LR, -ER, -LX4, and -SR PHY
S ........................................................................................ 1-3
Management ................................................................................................................................................... 1-3
Switch Configuration Using WebView ...................................................................................................... 1-3
Switch Configuration Using CLI Commands ............................................................................................ 1-3
Secure Networks Policy Support .................................................................................................................... 1-4
Standards Compatibility .................................................................................................................................. 1-4
LANVIEW Diagnostic LEDs ............................................................................................................................ 1-4
Chapter 2: Network Requirements
XFP 10-Gigabit Ethernet ................................................................................................................................ 2-1
Module Placement in a Matrix E7 Chassis ..................................................................................................... 2-2
Chapter 3: Installation
Unpacking the DFE-Diamond Module ............................................................................................................ 3-2
Installing an Optional XFP Module ................................................................................................................. 3-2
Backplane Connections and Installation Rules .............................................................................................. 3-3
FTM1 and FTM2 Connectivity .................................................................................................................. 3-3
Module Placement and Rules .................................................................................................................. 3-4
Installing Module into Matrix E7 or Matrix N7 Chassis ................................................................................... 3-6
Preparation ............................................................................................................................................... 3-6
Installing Module into Matrix N3 Chassis ........................................................................................................ 3-9
Connecting to the Network ........................................................................................................................... 3-10
Network Connection Using Fiber-Optic Cable ....................................................................................... 3-10
Connecting to COM Port for Local Management .......................................................................................... 3-11
What Is Needed ..................................................................................................................................... 3-11
Connecting to an IBM PC or Compatible Device ...................................................................................3-12
Connecting to a VT Series Terminal ...................................................................................................... 3-13
Connecting to a Modem ......................................................................................................................... 3-14
Adapter Wiring and Signal Assignments ................................................................................................ 3-15
Completing the Installation ........................................................................................................................... 3-16
Completing the Installation of a New System ......................................................................................... 3-17
Completing Installation of DFE-Diamond Module in an Existing System ............................................... 3-18
x
Chapter 4: Troubleshooting
Using LANVIEW ............................................................................................................................................. 4-1
Troubleshooting Checklist .............................................................................................................................. 4-4
Overview of DFE-Diamond Module Shutdown Procedure ............................................................................. 4-5
Recommended Shutdown Procedure Using OFFLINE/RESET Switch ................................................... 4-6
Last Resort Shutdown Procedure Using OFFLINE/RESET Switch ......................................................... 4-7
Appendix A: Specifications
DFE-Diamond Module Specifications .............................................................................................................A-1
10-Gigabit Ethernet Transceiver Specifications (XFP) ...................................................................................A-2
COM Port Pinout Assignments .......................................................................................................................A-3
Regulatory Compliance ..................................................................................................................................A-4
Appendix B: Mode Switch Bank Settings and Optional Installations
Required Tools ...............................................................................................................................................B-1
Setting the Mode Switches .............................................................................................................................B-1
Memory Locations and Replacement Procedures ..........................................................................................B-2
DRAM SIMM Replacement Procedure ....................................................................................................B-3
DIMM Replacement Procedure ...............................................................................................................B-5
Index
Figures
1-1 7K4297-02 DFE-Platinum Module...................................................................................................... 1-2
1-2 7K4297-04 DFE-Platinum Module...................................................................................................... 1-3
3-1 Installing an XFP ................................................................................................................................ 3-3
3-2 Examples, Module Placement in Matrix E7 Chassis .......................................................................... 3-4
3-3 Installing Module into Matrix E7 or Matrix N7 Chassis ....................................................................... 3-7
3-4 Installing Module into Matrix N3 Chassis............................................................................................ 3-8
3-5 SC Fiber-Optic Cable Connection .................................................................................................... 3-10
3-6 Connecting an IBM PC or Compatible Device.................................................................................. 3-12
3-7 Connecting a VT Series Terminal..................................................................................................... 3-13
3-1 Connecting to a Modem ................................................................................................................... 3-14
3-2 Matrix DFE Startup Screen Example (N7 Chassis) .......................................................................... 3-17
4-1 LANVIEW LEDs.................................................................................................................................. 4-2
4-1 OFFLINE/RESET Switch.................................................................................................................... 4-6
B-1 Mode Switch Location ........................................................................................................................B-2
B-2 DIMM and DRAM SIMM Locations.....................................................................................................B-3
B-3 Removing the Existing DRAM SIMM ..................................................................................................B-3
B-4 Installing the DRAM SIMM .................................................................................................................B-4
B-5 Removing the Existing DIMM .............................................................................................................B-5
B-6 Installing the DIMM.............................................................................................................................B-6
Tables
2-1 Recommended Cable Types and Specifications ................................................................................ 2-1
3-1 Carton Contents ................................................................................................................................. 3-2
4-1 LANVIEW LEDs.................................................................................................................................. 4-2
4-2 Troubleshooting Checklist .................................................................................................................. 4-4
A-1 Specifications .....................................................................................................................................A-1
A-2 XFP Port, Physical, and Environmental Specifications ......................................................................A-2
A-3 XFP Fiber-Optic Specifications...........................................................................................................A-3
A-4 Recommended Cable Types and Specifications ................................................................................A-3
A-5 COM Port Pin Assignments................................................................................................................A-3
A-6 Compliance Standards .......................................................................................................................A-4
Matrix DFE-Platinum Series Module Installation Guide xi
About This Guide
Thisguideprovidesanoverview,installationandtroubleshootinginstructions,andspecifications
fortheEnterasysMatrix
DFEDiamond7KR429702and7KR429704modulesandtheXFP
interfacemodules.
ForinformationabouttheCLI(CommandLineInterface)setofcommandsusedtoconfigureand
managetheDFEDiamondmodules,refertotheEnterasysMatrix™DFEDiamond/PlatinumSeries
ConfigurationGuide.
Who Should Use This Guide
Thisguideisintendedforanetworkadministratorresponsiblefor installingandsettingupthe
DFEPlatinummodules.
Note: In this guide, the following terms are used:
DFE refers to Distributed Forwarding Engine series of modules.
Unless otherwise noted, DFE module refers to both the 7KR4297-02 and 7KR4297-04 modules.
XFP refers to a 10-Gbps physical interface module inserted into a DFE module NEM slot.
PHY refers to a physical interface.
Important Notice
Depending on the firmware version used in the DFE module, some features described in this document may
not be supported. Refer to the Release Notes shipped with the DFE module to determine which features are
supported.
Electrical Hazard: Only qualified personnel should install or service this unit.
Riesgo Electrico: Nada mas personal capacitado debe de instalar o darle servicio a esta unida.
Elektrischer Gefahrenhinweis: Installationen oder Servicearbeiten sollten nur durch
ausgebildetes und qualifiziertes Personal vorgenommen werden.
How to Use This Guide
xii About This Guide
How to Use This Guide
ThisprefaceprovidesanoverviewofthisguideandtheDFEDiamondSeriesmanualset,abrief
summaryofeachchapter,anddefinestheconventionsusedinthisdocument.Tolocate
informationaboutvarioussubjectsinthisguide,refertothefollowingtable:
Related Documents
ThemanualslistedbelowcanbeobtainedfromtheWorldWideWebinAdobeAcrobatPortable
DocumentFormat(PDF)atthefollowingsite:
http://www.enterasys.com/support/manuals
EnterasysMatrix™DFEDiamond/PlatinumSeriesConfigurationGuideprovidesinformationon
howtousetheCommandLineInterfacetosetupandmanagetheDFE modules.
CablingGuideprovides
informationondBlossandcablespecifications.
UnliketheEnterasysMatrix™DFEDiamond/PlatinumSeriesConfigurationGuide,theCabling
Guideisnotlistedalphabeticallyonthewebsite.Instead,itislistedundertheOverviewGuides
link.
For... Refer to...
An overview of the DFE module and instructions to
obtain technical support from Enterasys Networks
Chapter 1, Introduction
Network requirements that must be met before
installing the DFE module
Chapter 2, Network Requirements
Instructions to install the DFE module hardware
and optional XFP interface module
Chapter 3, Installation
Troubleshooting installation problems and
diagnosing network/operational problems using the
LANVIEW LEDs
Chapter 4, Troubleshooting
Specifications, environmental requirements, and
physical properties of the DFE module and optional
XFP interface module
Appendix A, Specifications
Instructions to set the mode switches when
necessary and remove and replace DRAM SIMM
and DIMM memory
Appendix B, Mode Switch Bank Settings and
Optional Installations
Document Conventions
Matrix DFE-Platinum Series Module Installation Guide xiii
Document Conventions
Thefollowingtypographicalconventionsandiconsareusedinthi sdocument.
Commonly Used Acronyms
Thefollowingacronymsareusedextensivelythroughoutthisguide:
•ESDElectrostaticDischarge
•LEDLightEmittingDiode
•PHYPhysicalInterface
•XFP10GigabitSmallFormFactorPluggablefiberoptictransceiver
blue type Indicates a hypertext link. When reading this document online, click the text in blue to go to
the referenced figure, table, or section.
Lowercase x Indicates the general use of an alphanumeric character (for example, 6x1xx, the x’s
indicate a combination of numbers or letters).
Note: Calls the reader’s attention to any item of information that may be of special
importance.
Caution: Contains information essential to avoid damage to the equipment.
Precaución: Contiene información esencial para prevenir dañar el equipo.
Achtung: Verweißt auf wichtige Informationen zum Schutz gegen Beschädigungen.
Warning: Warns against an action that could result in personal injury or death.
Advertencia: Advierte contra una acción que pudiera resultar en lesión corporal o la
muerte.
Warnhinweis: Warnung vor Handlungen, die zu Verletzung von Personen oder gar
Todesfällen führen können!
Electrical Hazard: Warns against an action that could result in personal injury or death.
Riesgo Electrico: Advierte contra una acción que pudiera resultar en lesión corporal o la
muerte debido a un riesgo eléctrico.
Elektrischer Gefahrenhinweis: Warnung vor sämtlichen Handlungen, die zu Verletzung
von Personen oder Todesfällen – hervorgerufen durch elektrische Spannung – führen
können!
Getting Help
xiv About This Guide
Getting Help
Foradditionalsupportrelatedtothemodulesorthisdocument,contactEnterasys Networks
usingoneofthefollowingmethods:
BeforecontactingEnterasys N etworksfortechnicalsupport,havethefollowingdataready:
•YourEnterasys Networksservicecontractnumber
•Adescriptionofthefailure
•Adescriptionofanyaction(s)alreadytakentoresolvetheproblem(forexample,changing
modeswitchesorrebootingtheunit)
•TheserialandrevisionnumbersofallinvolvedEnterasys Networksproductsinthenetwork
•Adescriptionofyournetworkenvironment(suchaslayout,cabletype,otherrelevant
environmentalinformation)
•Networkloadandframesizeatthetimeoftrouble(ifknown)
•Thedevicehistory(forexample,if
youhavereturnedthedevicebefore,orifthisisarecurring
problem)
•AnypreviousReturnMaterialAu thorization(RMA)numbers
World Wide Web www.enterasys.com/support/
Phone 1-800-872-8440 (toll-free in U.S. and Canada)
or 1-978-684-1000
For the Enterasys Networks Support toll-free number in your country:
www.enterasys.com/support/
Internet mail sup[email protected]
To expedite your message, please type [SWITCHING] in the subject line.
To send comments or suggestions concerning this document to the Technical Publications Department:
To expedite your message, include the document Part Number in the Email message.
Matrix DFE-Platinum Series Module Installation Guide 1-1
1
Introduction
ThischapterprovidesanoverviewoftheMatrixDFEDiamond7KR429702and7KR429704
modulesandoptionalXFP10Gbpsphysicalinterfacemodule.
Overview of Matrix DFE-Diamond Module Capabilities
ThePlatinumDistributedForwardingEngine(DFE)isEnterasysNetworks’nextgenerationof
enterprisemodulesfortheMatrixNSeriesandMatrixE7switches.TheseDFEmodulesdeliver
highperformanceandflexibilitytoensurecomprehensiveswitching,routing,QualityofService,
security,andtrafficcontainment.Keyfeaturesinclude:
•Superiorperformanceandcapacityto
supportmorehighbandwidthandlatencysensitive
applications
10/100/1000BaseTXand10GigabitEthernetconnectivity
•IntegratedServicesDesignthatreducesthenumber/typeofmodulesrequired,simplifies
networkdesign,andlowersentrycost
•Port‐andUserBasedPolicyandMultilayerPacketClassificationthatprovidesgranular
controlandsecurityforbusinesscriticalapplications
•Highavailabilityserviceswithstatefulfailoverforservicesandmanagement
•Selflearningconfigurationmoduleswithincreasedreliabilityandfaulttolerancethatreduces
configurationtimeandmaximizesuptime
•Networkwideconfiguration,change,andinventorymanagementthatiseasiertoinstall,
troubleshoot,andmaintain
Reducedsupportandmaintenancecosts,anddecreasedconfigurationtime
Supportfor
avarietyofconvergedapplicationsincludingVoIPwithPoweroverEthernet
Note: Unless otherwise noted the term “DFE module” refers to both the 7KR4297-02 and
7KR4297-04 modules.
For information about...
Refer to page...
Overview of Matrix DFE-Diamond Module Capabilities 1-1
The DFE-Diamond 7KR4297-02 and 7KR4297-04 Modules 1-2
Management 1-3
Secure Networks Policy Support 1-4
Standards Compatibility 1-4
LANVIEW Diagnostic LEDs 1-4
The DFE-Diamond 7KR4297-02 and 7KR4297-04 Modules
1-2 Introduction
The DFE-Diamond 7KR4297-02 and 7KR4297-04 Modules
Thissectionprovidesanoverviewofthe7KR429702and7KR429704DFEDiamondmodules
showninFigure 11andFigure 12,aswellastheoptionalXFPphysicalinterfaces(PHYs).For
informationabouttheDFEDiamondmodulefeaturesandhowtoconfigurethem,refertothe
EnterasysMatrixDFE
Diamond/PlatinumSeriesConfigurationGuide.
7KR4297-02
The7KR429702DFEmodulehastwo10GbpsEthernetportslotsonthefrontpanelthatcan
supportuptotwo10GbpsXFPPHYsforhighspeeduplinksfromthechassisDFEEthernet
switchsystem.Withtwo10GbpsPHYsinstalledinthe 7KR429702,ashareduplinkof
upto
20 GbpscanbeprovidedfromtheDFEswitchingsystemtotwonetworkedgeconnectionsfroma
MatrixE7,MatrixN7,MatrixN5,MatrixN3,orMatrixN1chassistoacoredatacenter.
TheDFEmoduleportscanbeconfiguredtocontroltrafficbylimitingtherateof
trafficaccepted
intothemoduleandprioritizingtraffictoexpeditetheflowofhigherpriority trafficthroughthe
module.
The7KR429702modulecanbeinstalledinaMatrixE7,MatrixN7,MatrixN5,MatrixN3,or
MatrixN1chassis,butonlysupportsFTM2databackplaneinterconnectionsintheMatrixE7
chassis.
Figure 1-1 7KR4297-02 DFE-Diamond Module
7KR4297-04
The7KR429704DFEmodulehasfour10GbpsEthernetportslotsonthefrontpanelthatcan
supportuptofour10GbpsXFPPHYsforhighspeeduplinksfromthechassisDFEEthernet
switchsystem.Withfour10GbpsPHYsinstalledinthe7KR429704,ashareduplinkof
upto40
GbpscanbeprovidedfromtheDFEswitchingsystemtotwonetworkedgeconnectionsfroma
MatrixE7,MatrixN7,MatrixN5,MatrixN3,orMatrixN1chassistoacoredatacenter.
TheDFEmoduleportscanbeconfiguredtocontroltrafficbylimitingtherate
oftrafficaccepted
intothemoduleandprioritizingtraffictoexpeditetheflowofhigherpriority trafficthroughthe
module.
The7KR429704DFEmodulecanbeinstalledinaMatrixE7,MatrixN7,MatrixN5,MatrixN3,or
MatrixN1chassis,butonlysupportsFTM2databackplaneinterconnectionsinthe
MatrixE7
chassis.
1 RJ45 COM (also known as Console Port) 5 XFP option slot 2
2 CPU LED 6 OFFLINE/RESET switch
3 XFP option slot 1 7 MGMT LED
4 TX (transmit) & RX (receive) LEDs
Management
Matrix DFE-Platinum Series Module Installation Guide 1-3
Figure 1-2 7KR4297-04 DFE-Diamond Module
XFP 10GBASE-LR, -ER, -LX4, and -SR PHYS
TheLANXFPPHYs(physicalinterfaces)provideinexpensive,highspeedEthernetconnectivity.
ThesePHYsprovidenetworkmanagerstheabilitytouse10GigabitEthernettechnologiesto
providehighspeed,localbackboneinterconnectionsbetweenlargecapacityswitches.Asdemand
forbandwidthincreases,networkadministratorscandeploy10GigabitEthernetthroughoutthe
entire
networktoimproveserverfarm,backbone,andcampuswideconnectivity.
Management
Managementofthemodulecanbeeitherinbandoroutofband.Inbandremotemanagementis
possibleusingTelnet,Enterasys Networks’NetSight
®
managementapplication,orWebView
application.OutofbandmanagementisprovidedthroughtheRJ45COM(Communication)port
onthefrontpanelusingaVT100terminaloraVT100terminalemulator.
Switch Configuration Using WebView
Enterasys Networks’HTTPbasedWebmanagementapplication(WebView)isanintuitiveweb
toolforsimplemanagementtasks.
Switch Configuration Using CLI Commands
TheCLIcommandsenableyoutoperformmorecompleteswitchconfigurationmanagement
tasks.
ForCLIcommandsetinformationandhowtoconfigurethemodule,refertotheEnterasysMatrix
DFEDiamond/PlatinumSeriesConfigurationGuide.
1 RJ45 COM (also known as Console Port) 6 XFP option slot 3
2 CPU LED 7 XFP option slot 4
3 XFP option slot 1 8 OFFLINE/RESET switch
4 TX (transmit) & RX (receive) LEDs 9 MGMT LED
5 XFP option slot 2
Secure Networks Policy Support
1-4 Introduction
Secure Networks Policy Support
PolicyEnabledNetworkingmanagestheallocationofnetworkinginfrastructureresourcesina
secureandeffectivemanner.UsingSecureNetworksPolicy,anITAdministratorcanpredictably
assignappropriateresourcestotheUsers,Applications,andServicesthatusethenetwork;while
blockingorcontainingaccessforinappropriateorpotentiallydangerousnetworktraffic.Using
thistechnologyitispossible,forthefirsttime,toalignITserviceswiththeneedsofspecificusers
andapplications,andtoleveragethenetworkasakeycomponentoftheorganization’ssecurity
strategy.
TheSecureNetworksPolicyArchitectureconsistsof3components:ClassificationRules,Network
Services,andBehavioralProfiles.
Thesearedefinedasfollows:
ClassificationRulesdeterminehowspecifictrafficflows(identifiedbyLayer2,Layer3,and
Layer4informationinthedatapacket)aretreatedbyeachSwitch orRouter.Ingeneral,
ClassificationRulesareappliedtothenetworkinginfrastructureatthenetworkedge/ingress
point.
•NetworkServicesare
logicalgroupsofClassificationRulesthatidentifyspecificnetworked
applicationsorservices.Usersmaybepermittedordeniedaccesstotheseservicesbasedon
theirrolewithintheorganization.Priorityandbandwidthratelimitingmayalsobecontrolled
usingNetworkServices.
•BehavioralProfiles(orroles)areusedtoassignNetworkServices
togroupsofuserswho
sharecommonneeds–forexampleExecutiveManagers,HumanResourcesPersonnel,or
GuestUsers.Access,resources,andsecurityrestrictionsareappliedasappropriatetoeach
BehavioralProfile.Avarietyofauthenticationmethodsincluding802.1X,EAPTLS,EAP
TTLS,andPEAPmaybeusedtoclassifyandauthorizeeach
individualuser;andtheIT
AdministratormayalsodefineaBehavioralProfiletoapplyintheabsenceofan
authenticationframework.
Standards Compatibility
TheDFEDiamondmodulesarefullycompliantwiththeIEEE802.32002,802.3ae2002,
802.1D1998,and802.1Q1998standards.TheDFEDiamondmoduleprovidesIEEE802.1D1998
SpanningTreeAlgorithm(STA)supporttoenhancetheoverallreliabilityofthenetworkand
protectagainst“loop”conditions.
LANVIEW Diagnostic LEDs
LANVIEWdiagnosticLEDsserveasanimportanttroubleshootingaidbyprovidinganeasyway
toobservethestatusofindividualportsandoverallnetworkoperations.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64

Enterasys Networks DFE-Platinum Series User manual

Category
Networking
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI