ARAG BRAVO 300S Quick Reference Manual

Type
Quick Reference Manual
PREPARING THE TREATMENT
Quick reference guide
USE
Used to scroll data
or edit values
Sets data to zero
Confirms access
or change to data
Quits function
or changes to data
ONLY enabled jobs are displayed
Job selection
02) 90 l/ha * ISO015 Green
>06) 240 l/ha ISO04 Red
Reset all data?
>No
Yes
Job selection
1
Active job
*
Selected job
>
Tank Filling
2
Tank capacity
Advanced Setup/
Tank/
Capacity: 3000 l
Liquid in tank:
after filling enter the level of liquid
contained in the tank
If the filling flow meter is connected,
the display will also show the filling status.
ATTENTION! Maximum level reached
Stop the filling pump:
you have reached the maximum tank capacity
Selected setting
>
Tank
Filling up : 3000 l
> Level : 1540 l
Filled quantity : 0 l
Main ON Log OFF
21.0 bar 425 rpm 725 l
1
Manual treatment control
Turn on the section valves required
Drive to the start of the field
2
3
Set the main switch to ON
Run the treatment
4
5
Use the control valve switch
to adjust the desired quantity
6
Enable manual operation
1
Man.
Man.
2
Automatic treatment control
Enable automatic operation
Turn on the section valves required
Drive to the start of the field
Set the main switch to ON
Run the treatment
Use the control valve switch
to temporarily modify the metering
2
3
4
5
6
1
Main ON Log OFF
21.0 bar 425 rpm 725 l
90 l/ha
90l/ha
The computer keeps
the set distribution value constant
User setting
User setting
Main ON Log OFF
21.0 bar 425 rpm 725 l
90 l/ha
OPERATING ALARMS
Data recorder status
Speed
RPM / Covered area
Flow rate
SELECTING THE WHEEL TYPE (CONSTANT)
via Palladio, 5/A - 42048 RUBIERA (RE) - Italy - tel. 0522 622011 - Fax 0522 628944 - www.aragnet.com Cod. D20156.GB-m01
KEY TO ITEMS ON DISPLAY
Speed
> Source : Wheel sensor
Selected wheel type : 1
Wheels setting : ...
Selected setting
>
Select the wheel type (3 types available)
Clock
Disable spraying command!
- Main switch ON at computer startup
Go fast! Insufficient pressure
- Pressure does not reach minimum value for nozzle in use
Go slow! High pressure
- Pressure exceeds maximum level permitted for nozzle in use
Start pump! No flowrate
- Main switch ON, machine stationary
but zero capacity
Go! The machine is stopped
- Main switch ON and machine stationary
Go slow! Insufficent flowrate
- Capacity does not reach value required for distribution
Go fast! High flowrate
- Capacity exceeds value required for distribution
Reduce rotation speed!
- RPM exceeds maximum value permitted
Increase rotation speed!
- RPM does not reach minimum value
Stop immediately! Pump fault
- Pump oil level too low or mixed with water
Flowmeter out of range
- Capacity exceeds limits permitted by flow meter
ONLY with
automatic
operation
Output variation rate
Spraying status
Target rate
Measured output
Fluid in tank (text and graphic)
Pressure
21.0 bar 425 rpm 725 l
Go! The machine is stopped
SD card not found!
- Memory board not inserted correctly
SD card write protected!
- Memory board locked
SD card full!
- No space available on memory board
SETUP.BIN: File not found!
- PC configuration has not been saved
Signal out of range! Check transducer
- Faulty pressure values detected
Check nozzles! Highly worn
- Difference between values read by pressure sensor
and flow meter exceeds maximum value permitted
The menu can be accessed both ways
Used to scroll data
or edit values
Sets data to zero
Confirms access
or change to data
Quits function
or changes to data
  • Page 1 1
  • Page 2 2

ARAG BRAVO 300S Quick Reference Manual

Type
Quick Reference Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI