Dome DMOF1 User manual

Type
User manual
Always Connected. Always Covered.
On/Off Plug-In Switch
User Manual
DMOF1
Page 2
On/Off Plug-In Switch Advanced User Manual
Preface
As this is the full User Manual, a working knowledge of Z-Wave automation
terminology and concepts will be assumed. If you are a basic user, please visit
www.domeha.com for instructions. This manual will provide in-depth technical
information about the On/Off Plug-In Switch, especially in regards to its compli-
ance to the Z-Wave standard (such as compatible Command Classes, Associa-
tion Group capabilities, special features, and other information) that will help
you maximize the utility of this product in your system.
Preface
Page 3
On/Off Plug-In Switch Advanced User Manual
Table of Contents
Table of Contents
Preface ................................................................................................................................. 2
Description & Features ..................................................................................................... 4
Specifications ..................................................................................................................... 5
Physical Characteristics ................................................................................................... 6
Inclusion & Exclusion ........................................................................................................ 7
Factory Reset & Misc. Functions ..................................................................................... 8
Physical Installation .......................................................................................................... 9
LED Behavior .................................................................................................................... 10
Button Behavior ............................................................................................................... 11
Compatible Command Classes ..................................................................................... 12
“Configuration Command Class Parameters ............................................................ 16
Troubleshooting .............................................................................................................. 19
Warranty & Support ........................................................................................................ 20
Page 4
On/Off Plug-In Switch Advanced User Manual
Description & Features
The Dome On/Off Plug-In Switch is a Z-Wave Plus device that plugs into a
standard 3-prong power outlet and lets you turn on or off any connected elec-
tronic device. The On/Off Plug-In Switch also monitors how much energy the
attached device uses, and reports the data to your Z-Wave Hub.
Key Features:
» Z-Wave Plus Certified
» Turns on or off any plugged-in device
» Extends the range of your Z-Wave system
» Up to 150’ wireless range, depending on environment
» Small size - won’t block the adjacent outlet!
» Fits any standard 3-prong American power outlet
» Reports energy consumption data
» Overload protection
» Max current - 13 A
*Event-based response requires use of external sensors and compatible controller
SolidWorks Student Edition.
For Academic Use Only.
Description & Features
Page 5
On/Off Plug-In Switch Advanced User Manual
Specications
Package Contents:
Technical Specications
Radio protocol Z-Wave Plus (500 series)
Power supply 110-230V AC 50/60Hz
Max Current 13A
Power Consumption 0.13W
Radio frequency 908.4 MHz US
Z-Wave Range Up to 150’ depending on environment
Dimensions (L x W x H) 1.8” x 1.8” x 1.8”
Table 1 - Technical Specications
USER MANUAL On/Off Plug-In Switch
SolidWorks Student Edition.
For Academic Use Only.
Specications
Page 6
On/Off Plug-In Switch Advanced User Manual
Physical Characteristics
The names used in Figures 1 & 2 will be used throughout this manual. Please
refer to this page as needed.
SolidWorks Student Edition.
For Academic Use Only.
BUTTON
DEVICE PORT
PLUG
Figure 1 - On/Off Plug-In Switch Parts
SolidWorks Student Edition.
For Academic Use Only.
DMOF1
Figure 2 - Bottom View
Physical Characteristics
Page 7
On/Off Plug-In Switch Advanced User Manual
Inclusion & Exclusion
Inclusion
Follow the instructions for your Z-Wave Certified Conto enter inclusion mode.
When prompted by the controller:
1. Plug the On/Off Plug-In Switch into an outlet 10’ from your controller. You
can bring it to your desired location after the inclusion process.
2. When prompted by the controller, quickly press the BUTTON 3 times.
3. A yellow LED will flash five times indicating inclusion.
Exclusion
Follow the instructions for your Z-Wave Certified Conto enter exclusion mode.
When prompted by the controller:
1. Plug the On/Off Plug-In Switch into an outlet 10’ from your controller.
2. Press the BUTTON quickly 3 times in a row.
3. A yellow LED will flash five times indicating exclusion/disconnection.
Inclusion & Exclusion
Page 8
On/Off Plug-In Switch Advanced User Manual
Factory Reset & Misc. Functions
Resetting the On/Off Plug-In Switch
If needed, the On/Off Plug-In Switch can be reset locally by following these
steps. Only do this when your Z-Wave controller is disconnected or otherwise
unreachable. Beware that resetting your device will disconnect it from the sys-
tem:
1. Confirm that your On/Off Plug-In Switch is powered up.
2. Press and hold the BUTTON for at least 10 seconds then release. The LED
will blink once in a red color followed by 5 times in a pink color indicating
a successful factory reset.
3. The On/Off Plug-In Switch’s memory will be erased to factory settings.
Factory Reset & Misc. Functions
Page 9
On/Off Plug-In Switch Advanced User Manual
Physical Installation
The On/Off Plug-In Switch can be installed in any standard 3-prong American
power outlet. To control or monitor an electronic device, simply plug it into the
DEVICE PORT. Make sure there is sufficient Z-Wave coverage in your desired
installation location.
Physical Installation
Page 10
On/Off Plug-In Switch Advanced User Manual
LED Behavior
Color Behavior This happens when…
Pink
Blink 5 times in 1 second …the device powers on, but is not yet included in a
Z-Wave Network.
Blink 5 times in 500ms
…the BUTTON is pushed 3 times after the
On/Off Plug-In Switch is already in a Z-Wave net-
work, and the device sends a notication with its
Node Info.
Blue Blink 5 times in 300ms …the device powers on, and is arleady included in
a Z-wave network.
Yellow
Blink 5 times in 500ms …the BUTTON is pushed three times, including the
On/Off Plug-In Switch into a Z-Wave network.
Always On …the current is above the limit set in Param 4 (12A
by default.)
Red
Blink Once
…the BUTTON is pressed for an extended period of
time, resetting the On/Off Plug-In Switch to factory
default settings.
Blink Once a Second
…the current is above the limit set in Param 3 (13A
by default.) Power will be shut off; LED and power
will return to normal when the current drops below
the level set in Param 3 and the BUTTON is pushed
once.
Green Always On …the On/Off Plug-In Switch is powered on.
Table 2 - LED Blinking Behavior
LED Behavior
Page 11
On/Off Plug-In Switch Advanced User Manual
Button Behavior
Action Condition Result
Push Button Once
Param 10 = 1 Turn Device on or off
Param 10 = 0 Nothing
Push BUTTON 3
Times
On/Off Plug-In Switch
Already Included in System Device sends node info to Group 1
On/Off Plug-In Switch
Already Included in
System and Controller is in
Exclusion Mode
Device is excluded from the z-Wave Network
On/Off Plug Not Yet
Included in System Device enters inclusion mode
Press and Hold for
10+ seconds All conditions
Device will be reset to factory settings, and a
DEVICE_RESET_LOCALLY command will be sent to
Node 1
Table 3 - Button Behavior
Button Behavior
Page 12
On/Off Plug-In Switch Advanced User Manual
Compatible Command Classes
Command Class Notes
Device Reset Locally V1 (5A) -
Powerlevel V1 (73) -
Association Group Information V1 (59) -
Binary Switch V1 (25) -
All Switch V1 (27) -
Basic V1 (20) -
Z-Wave Plus Info V2 (5E)
Returned Value: 01 05 00 07 00 07 00
Z-Wave Plus Version: 01
Role Type: 05
(Slave
Always On)
Node Type: 00
(Z-Wave Plus Node)
Installer Icon Type: 07 00
(Generic Relay Device)
User Icon Type: 07 00
(Generic Relay Device)
Version V2 (86)
Returned Value: 03 04 05 03 46 41 00
Z-Wave Library Type: 03
(Enhanced Slave)
Protocol Version: 04 05
Protocol Sub-Version: 03 46
Application Version: 41
Application Sub-Version: 00
Manufacturer Specic V2 (72)
Returned Value: 02 1F 03 01 03
Manufacturer ID: 02 1F
Product Type: 03
Product ID: 01 03
Table 4 - Command Classes
Compatible Command Classes
Page 13
On/Off Plug-In Switch Advanced User Manual
Compatible Command Classes
Command Class Notes
Association V2 (85)
Group 1
Group 1 is the “Lifeline” group, which can hold ve devices. The
On/Off Plug-In Switch sends this group a Notication Report and Bi-
nary Switch Report whenever it is turned on or off. It also sends a
Meter Report incrementally based on time (see Param 2,) or when a
relative change in power usage is detected (see Param 6.) Finally, the
On/Off Plug-In Switch sends this group a Device Reset Locally notica-
tion to remove itself from the Z-Wave network.
Group 2
The On/Off Plug-In Switch sends a BASIC_SET(FF) command to Associ-
ation Group 2 to directly trigger devices (like a siren, chime, etc.) when
the current passes above the level set in Parameter 3. When the current
drops below the level again, a BASIC_SET(00) command is sent to reset
the device (e.g. turn off the siren.) This Group can hold ve devices.
Group 3
The On/Off Plug-In Switch sends Notication Reports to Group 3, and it
can hold ve devices.
Notication V4 (71)
The On/Off Plug-In Switch sends a NOTIFICATION_REPORT to Group
1 when the current load passes the level set in Param 3, and
another report when it drops back below this level. See below for the
NOTIFICATION_REPORT parameters sent:
Returned Value: 00 00 00 FF 08 XX 00 00
V1 Alarm Type: 00
(Unsupported)
V1 Alarm Level: 00
(Unsupported)
Reserved: 00
(Reserved)
Notication Status: FF
(Unsolicited Reporting is Enabled)
Notication Type: 08
(Power Management)
Event:
Overload Detected—06
(Over-Current Detected)
No More Overload—00
(Event Inactive)
Sequence/Reserved/Event Parameters Length: 00
Notication Event Parameters: 00
(No Event Parameters)
Table 5 - Command Classes Continued
Page 14
On/Off Plug-In Switch Advanced User Manual
Compatible Command Classes
Command Class Notes
Meter V4 (32)
When enabled (see Param 1,) the On/Off Plug-In Switch sends period updates
with various usage information to Group 1 using the Meter Command Class.
These reports are sent periodically (every 300s by default - see Param 2) as
well as when a change in current is detected (see Param 6.)
Voltage—The voltage currently being supplied by the plug (in V)
Current—The current being supplied by the plug (in A)
Power—The power supplied by the plug instantaneously (in W)
Energy—The amount of energy supplied per unit time (in kWh)
Returned Value: 21 44 XX XX XX XX YY YY ZZ ZZ ZZ ZZ 00
Scale/Rate Type/Meter Type/Size/Precision: 21 44
(0010 0001 0100 0100)
Scale (2)—0
Rate Type—01
(Import [Consumed])
Meter Type—0 0001
(Electric Meter)
Precision—010
(2 decimal places)
Scale (1:0)—0 0
Size—100
(4 Bytes)
Scale (Summed)—0 0 0
(Kilowatt-Hours)
Meter Value:
80 00 00 00 ~ 7F FF FF FF
(-2,147,483,648 ~ 2,147,483,647 in kWh)
Delta Time:
00 00 ~ FF FF
(0 ~ 65,535 in seconds)
Previous Value:
80 00 00 00 ~ 7F FF FF FF
(-2,147,483,648 ~ 2,147,483,647 in kWh)
Scale 2: 00
Returned Value: 21 54 XX XX XX XX YY YY ZZ ZZ ZZ ZZ 00
Scale/Rate Type/Meter Type/Size/Precision: 21 54
(0010 0001 0101 0100)
Scale (2)—0
Rate Type—01
(Import [Consumed])
Meter Type—0 0001
(Electric Meter)
Precision—010
(2 decimal places)
Scale (1:0)—1 0
Size—100
(4 Bytes)
Scale (Summed)—0 1 0
(Watts)
Meter Value:
80 00 00 00 ~ 7F FF FF FF
(-2,147,483,648 ~ 2,147,483,647 in kWh)
Delta Time:
00 00 ~ FF FF
(0 ~ 65,535 in seconds)
Previous Value:
80 00 00 00 ~ 7F FF FF FF
(-2,147,483,648 ~ 2,147,483,647 in kWh)
Scale 2: 00
Table 6 - Command Classes Continued
Page 15
On/Off Plug-In Switch Advanced User Manual
Compatible Command Classes
Command Class Notes
Meter V4 (32)
Returned Value: A1 42 XX XX YY YY ZZ ZZ 00
Scale/Rate Type/Meter Type/Size/Precision: A1 42
(1010 0001 0100
0010)
Scale (2)—1
Rate Type—01
(Import [Consumed])
Meter Type—0 0001
(Electric Meter)
Precision—010
(2 decimal places)
Scale (1:0)—0 0
Size—010
(2 Bytes)
Scale (Summed)—1 0 0
(Volts)
Meter Value:
80 00 ~ 7F FF
(-32,768 ~ 32,767 in V)
Delta Time:
00 00 ~ FF FF
(0 ~ 65,535 in seconds)
Previous Value:
80 00 ~ 7F FF
(-32,768 ~ 32,767 in V)
Scale 2: 00
Returned Value: A1 4A XX XX YY YY ZZ ZZ 00
Scale/Rate Type/Meter Type/Size/Precision: A1 4A
(1010 0001 0100
1010)
Scale (2)—1
Rate Type—01
(Import [Consumed])
Meter Type—0 0001
(Electric Meter)
Precision—010
(2 decimal places)
Scale (1:0)—0 1
Size—010
(2 Bytes)
Scale (Summed)—1 0 1
(Amperes)
Meter Value:
80 00 ~ 7F FF
(-32,768 ~ 32,767 in A)
Delta Time:
00 00 ~ FF FF
(0 ~ 65,535 in seconds)
Previous Value:
80 00 ~ 7F FF
(-32,768 ~ 32,767 in A)
Scale 2: 00
Conguration V1 (70) See ““Conguration” Command Class Parameters” on page 16.
Table 7 - Command Classes Continued
Page 16
On/Off Plug-In Switch Advanced User Manual
“Conguration” Command Class Parameters
Param
# Size Name Available Values
Default
Value
01
This parameter enables/disables the METER_REPORT function, which sends periodic reports to Group1 members
with information on line voltage, current load, and power & energy consumption. Also see Param 2 & 6.
01 Enable/Disable METER_REPORT 00
(Disable Meter Functionality)
01
(Enable Meter Functionality)
01
(Meter En-
abled)
02
This parameter sets the amount of time between each successive METER_REPORT signal sent to Group 1 (also see
Param 1 & 6.)
02 METER_REPORT Interval 00 01 ~ FF FF
(1 ~ 65535 in seconds)
01 2C
(300 Sec)
03
Sets the maximum current the plug will pass before it cuts off power and sends a NOTIFICATION_EVENT_POWER_
MANAGEMENT_OVER_LOAD_DETECTED signal to Group 1 and a BASIC_SET(FF) to Group 2. The LED will then blink
red once per second until the current returns to normal. To clear the NOTIFICATION and start monitoring again, the
BUTTON must be pushed once (only after the current is back to normal.)
NOTE: this value must be higher than Param 4
01 Set “Overload” Current Level 01 ~ 10
(1 ~ 16 in amps)
0D
(13 Amps)
Table 8 - On/Off Plug-In Switch Conguration Parameters
Configuration parameters are sent using a standard syntax to ensure interopera-
bility between all manufacturers’ products. All values are represented using the
hexadecimal number system.
Typical syntax is as shown below. Note that the value sent must be the exact size,
in bytes, as accepted by the setting. The “extra” spaces should be filled with zeros
(see the “value” column below.)
Example Configuration Parameter: 02 02 00 0A
Param # Size Value
02
(Param #2)
02
(2 Bytes)
00 0A
(10)
“Conguration” Command Class Parameters
Page 17
On/Off Plug-In Switch Advanced User Manual
“Conguration” Command Class Parameters
Param
# Size Name Available Settings
Default
Setting
04
Sets the current level at which the On/Off Plug-In Switch will ash its LED yellow, until the current returns to below
this level. It will NOT cut off current to the device; this functions as a visible warning to the user.
NOTE: this value must be lower than Param 3
01 Set “Alert” Current Level 01 ~ Param(3)
(In amps)
0C
12 Amps
05
This parameter enables or disables the indicator LED.
01 Enable/Disable Indicator LED 00
(Disable LED)
01
(Enable LED)
01
(LED
Enabled)
06
In addition to sending a METER_REPORT to Group 1 in the time interval set by Param 2, the On/Off Plug-In Switch
also sends a METER_REPORT when it detects a relative change in current ow. This parameter sets this minimum
current change amount, in percent, at which point the On/Off Plug-In Switch will send a METER_REPORT to Group 1.
Also see Param 1 & 2.
01 Current change METER_REPORT
level
01 ~ 64
(1~100 in % change in amps)
05
(5%)
07
This parameter sets whether or not the On/Off Plug-In Switch will remember if it was turned on or off when it was
last plugged in. If enabled, whenever the device is rebooted (plugged in and out of the main outlet,) it will resume
its state from before the reboot. If disabled, it will turn on everytime the device is rebooted.
01 Remember On/Off Status 00
(Don’t Remember On/Off Status)
01
(Remember On/Off Status)
01
(Remember
Status)
08
If this parameter is enabled, whenever the On/Off Plug-In Switch is turned on, it will automatically turn off after a set
amount of time (set in Param 9.)
01 Enable/Disable Timer Function 00
(Disable Timer Functionality)
01
(Enable Timer Functionality)
00
(Timer
Disabled)
Table 9 - On/Off Plug-In Switch Conguration Parameters, cont’d
Page 18
On/Off Plug-In Switch Advanced User Manual
“Conguration” Command Class Parameters
Param
# Size Name Available Settings
Default
Setting
09
Sets the time interval before the On/Off Plug-In Switch automatically shuts off. See Param 8.
02 Set Timer Time Interval 00 01 ~ FF FF
(1 ~ 65535 in Minutes)
00 96
(150 min)
0A
If this parameter is enabled, the user can turn the device on or off using the BUTTON.
01 Enable/Disable BUTTON 00
(Disable Button)
01
(Enable Button)
01
(Button
Enabled)
Table 10 - On/Off Plug-In Switch Conguration Parameters, cont’d
Page 19
On/Off Plug-In Switch Advanced User Manual
Troubleshooting
:Q Help! My On/Off Plug-In Switch paired successfully, but my con-
troller can’t see it anymore after I installed it!
:A The Z-Wave signal is probably weak in that area of your home. Remember that the
120' - 150' range doesn’t take into account walls, furniture, and other obstacles.
To boost your Z-Wave network coverage, add a few non-battery powered Z-Wave
devices between the controller and the furthest device, like the Dome On/Off Plug
or Water Main Shut-Off. You can even purchase dedicated Z-Wave extenders from
3rd party manufacturers.
:Q There’s so many words in this manual I don’t understand. How can
I learn more about Z-Wave?
:A Remember you don’t have to understand everything in this manual to start
automating your home. Our Quick-Start Guides have all you need to start using
any device. For more thorough information about Z-Wave home automation, visit
www.domeha.com/support.
:Q I’ve tried multiple times, but I can’t include the On/Off Plug-In Switch
in my system.
:A Make sure your device is getting power. Then, follow the procedure to Factory
Reset on Page 8 and try going through the inclusion process again. If you are still
having issues, please visit www.domeha.com/support
:Q All of a sudden, my On/Off Plug-In Switch is offline.
:A Make sure your device is getting power. If powered, make sure you still have
Z-Wave network coverage. If you are still having issues, visit www.domeha.com/
support.
:Q A red LED is blinking and my device turned off by itself.
:A There was too much current flowing through the On/Off Plug-In Switch and it was
shut off as a precautionary measure. After you make sure the current is back
to normal, just push the BUTTON once and your device should start working like
before.
Troubleshooting
Page 20
On/Off Plug-In Switch Advanced User Manual
Warranty & Support
If you have questions, our trained Customer Service Depart-
ment is happy to assist you 24 hours a day, 7 days a week.
Contact Dome Customer Service as follows: • In North America
dial: 1-855-249-1754 • Email Dome at support@domeHA.com
DO NOT RETURN THIS PRODUCT TO THE STORE OR WEBSITE
FROM WHICH IT WAS PURCHASED
If you believe the product is defective, has a missing or broken
part or are having difculty with it please contact Dome as list-
ed above for a quick and efcient solution to the problem.
Legal Notices: This device complies with part 15 of the FCC
rules. Operation is subject to the following two conditions (1)
This device may not cause harmful interference, and (2) this
device must accept any interference received, including inter-
ference that may cause undesired operation.
Note: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential instal-
lation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harm-
ful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the
interference by one or more of the following measures: Reori-
ent or relocate the receiving antenna; increase the separation
between the equipment and the receiver; connect the equip-
ment into an outlet on a circuit different from that to which the
receiver is connected. Consult the dealer or an experienced
radio/TV technician for help.
This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two condi-
tions: (1) this device may not cause interference, and (2) this
device must accept any interference, including interference
that may cause undesired operation of the device.
Elexa Consumer Products, Inc. (”ECP”) warrants to the original
retail purchaser (”Purchaser”) that the DOME Window/Door
sensor (the “Product”) will be free of defects in materials or
workmanship under use for one (1) year from the date of pur-
chase (the “Warranty period”).
For the Purchaser only, if the Product fails to perform as speci-
ed during the Warranty Period due to defective parts or faulty
workmanship, ECP will repair or replace the defective or dam-
aged parts of the Product. Normal wear and tear is not covered
nor is abnormal use, misuse, mishandling, faulty installation,
improper shipping, damage caused by disasters such as re,
ood or earthquake, neglect, accident or tampering. This war-
ranty covers only normal use in the United States or Canada.
To obtain warranty service during the Warranty Period, call
Dome Customer Service (1-855-249-1754) or email: support@
domeHA.com for instructions on sending damaged parts and
documentation for a Return Material Authorization (RMA).
Products returned to ECP for repair or replacement without au-
thorization will be returned at the sender’s expense. All warran-
ty claims must be accompanied by a legible copy of the original
receipt showing date and details of purchase. The RMA number
must be clearly written on the side of the shipping container in
which you return the Product or defective parts. Unless other-
wise instructed by ECP, the Product must be sent freight pre-
paid to the following address:
Elexa Consumer Products, c/o Promac,
1153 Timber Dr., Elgin, IL 60123
ECP will repair or replace the defective parts and return them
at ECP’s cost by a shipping method selected by ECP. When con-
tacting ECP to obtain an RMA, Purchaser may request expedit-
ed return shipping at Purchaser’s expense.
THIS WARRANTY IS NOT TRANSFERABLE, AND, TO THE MAXI-
MUM EXTENT PERMITTED BY APPLICABLE LAW IS IN LIEU OF
ALL OTHER WARRANTIES, REPRESENTATIONS AND CONDI-
TIONS, EXPRESSED OR IMPLIED, STATUTORY OR OTHERWISE,
INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
NO OTHER PERSON OR REPRESENTATIVE IS AUTHORIZED TO
MAKE ANY OTHER WARRANTY ON BEHALF OF ECP OR ASSUME
FOR ECP ANY OTHER LIABILITY IN CONNECTION WITH THE SALE
OF THIS PRODUCT. IN NO EVENT WILL ECP BE LIABLE FOR ANY
DAMAGES, INCLUDING BUT NOT LIMITED TO INCIDENTAL, SPE-
CIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE
OR INABILITY TO USE THE PRODUCT, INCLUDING DAMAGES
DUE TO ECP’S NEGLIGENCE.
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU
MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO
STATE AND COUNTRY TO COUNTRY.
This marking on the product, accessories or literature indicates
that the product and its electronic accessories should not be
disposed of with other household waste.
To prevent possible harm to the environment or human health
from uncontrolled waste disposal, please separate these items
from other types of waste and recycle them responsibly to pro-
mote the sustainable reuse of material resources.
Household users should contact either the retailer where they
purchased this product, or their government ofce, for details
of where and how they can take these items for
environmentally safe recycling.
Business users should contact their supplier and check the
terms and conditions of the purchase contract. This product
and its electronic accessories should not be mixed with
other wastes for disposal.
This marking on the battery, manual or packaging indicates
that the batteries in this product should not be disposed of with
other household waste. Where marked, the chemical symbols
Hg, Cd or Pb indicate that the battery contains mercury, cadmi-
um or lead above the reference levels in EC Directive 2006/66.
If batteries are not properly disposed of, these substances can
cause harm to human health or the environment.
Warranty & Support
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Dome DMOF1 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI