Munters IceDry 30 Owner's manual

  • Hello! I am an AI chatbot trained to assist you with the Munters IceDry 30 Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Originalinstructions
Usermanual
IceDry30
Desiccantdehumidier
190TEN-1049-H1307©MuntersEuropeAB2013
Importantuserinformation
Intendeduse
Muntersdehumidiersareintendedtobeusedforthe
dehumidicationofair.Anyotheruseoftheunit,or
usewhichiscontrarytotheinstructionsgiveninthis
manual,cancausepersonalinjuryanddamagetotheunit
andotherproperty.
Nomodicationoftheunitisallowedwithoutprior
approvalbyMunters.Attachmentorinstallation
ofadditionaldevicesisonlyallowedafterwritten
agreementbyMunters.
Warranty
Thewarrantyperiodisvalidfromthedatetheunit
leftourfactory,unlessotherwisestatedinwriting.
Thewarrantyislimitedtoafreeexchangeofpartsor
componentswhichhavefailedasaresultofdefectsin
materialsorworkmanship.
Allwarrantyclaimsmustincludeproofthatthe
faulthasoccurredwithinthewarrantyperiodand
thattheunithasbeenusedinaccordancewiththe
specications.Allclaimsmustspecifytheunittypeand
fabricationnumber.Thisinformationisstampedonthe
identicationplate,seesectionMarking.
Itisaconditionofthewarrantythattheunitforthefull
warrantyperiodisservicedandmaintainedbyaqualied
MuntersengineerorMuntersapprovedengineer.
Accesstospecicandcalibratedtestequipmentis
necessary.Theserviceandmaintenancemustbe
documentedforthewarrantytobevalid.
AlwayscontactMuntersforserviceorrepair.Operating
faultscanoccuriftheunitismaintainedinsufcientlyor
incorrectly.
Safety
Informationaboutdangersareinthismanualindicated
bythecommonhazardsymbol:
W W
W
ARNING! ARNING!
ARNING!
Indicatesapossibledangerthatcanleadtopersonalinjury.
CA CA
CA
UTION! UTION!
UTION!
Indicatesapossibledangerthatcanleadtodamagetothe
unitorotherproperty,orcauseenvironmentaldamage.
NOTE!Highlightssupplementaryinformationforoptimal
useoftheunit.
ConformitywithDirectives
Thedehumidierisinconformitywiththeessential
safetyrequirementsoftheMachineryDirective
2006/42/EC,theLowVoltageDirective2006/95/EC
andtheEMCDirective2004/108/EC.The
dehumidierismanufacturedbyanISO9001:2008
accreditedmanufacturingorganisation.
Copyright
Thecontentsofthismanualcanbechangedwithout
priornotice.
NOTE!Thismanualcontainsinformationwhichis
protectedbycopyrightlaws.Itisnotallowedtoreproduceor
transmitanypartofthismanualwithoutwrittenconsentfrom
Munters.
Pleasesendanycommentsregardingthismanualto:
MuntersEuropeAB
TechnicalDocumentation
P.O.Box1150
SE-16426KISTASweden
e-mail:t-doc@munters.se
iiImportantuserinformation190TEN-1049-H1307
Tableofcontents
Importantuserinformation...............ii
Intendeduse...........................
ii
Warranty...............................
ii
Safety..................................
ii
ConformitywithDirectives............
ii
Copyright..............................
ii
Tableofcontents...........................iv
1Introduction.................................1
1.1General................................
1
1.2Aboutthismanual.....................
1
1.3Safetyandcautions...................
1
1.4Marking................................
3
1.5Supervisionofoperation..............
3
1.6Faultindications.......................
3
2Productdesign..............................4
2.1Productdescription...................
4
2.2Principleofoperation..................
4
2.3Maincomponents.....................
5
3Transport,inspectionandstorage.......6
3.1Movingtheequipment................
6
3.2Packaginganddeliveryinspection...
6
3.3Storingtheequipment................
6
4Installation...................................7
4.1General................................
7
4.2Safety..................................
7
4.3Siterequirements.....................
7
4.4Wheretoinstallthedehumidier.....
8
4.5Ducting.................................
8
4.5.1Generalrecommendations...
8
4.5.2Processairinlet................
9
4.5.3Dryairoutletduct..............
9
4.5.4Reactivationairintake........
9
4.5.5Ductworkforwetairoutlet.....
10
4.6Installationexamplescoldstorage
room(freezer).........................
11
4.7Electricalconnections................
12
4.8Pre-startsettings......................
13
4.9Pre-startchecks.......................
13
4.10Airowcheckandadjustment........
14
5Operation....................................15
5.1General................................
15
5.2Safety..................................
15
5.3Quickstop..............................
15
5.4Externalelectricalcabinet............
16
5.5Operatingtheunit.....................
17
5.5.1General.........................
17
5.5.2Start.............................
17
5.5.3Restartafterpowerfailure.....
17
5.5.4Stop.............................
18
5.5.5Alarms..........................
18
5.6Defrosting..............................
18
5.6.1Duringoperation...............
18
5.6.2Duringdowntime...............
18
6Controlsystem..............................19
6.1General................................
19
6.2Structure...............................
19
6.3Workingwiththecontrolsystem......
19
6.4Operatingwindows(windows1-5)...
20
6.4.1Window1,Reactivation
temperature....................
20
6.4.2Window2,Runtime............
20
6.4.3Window3,Motorstatus........
21
6.4.4Window4,Reactivation
power...........................
21
6.4.5Window5,Alarm...............
21
6.5Basicsettings(windows10-12)......
22
6.5.1Display10,Software
information.....................
22
6.5.2Display11,Defrostingduring
operation.......................
22
6.5.3Window12,Defrostingduring
downtime.......................
23
7Serviceandmaintenance.................24
7.1Safety..................................
24
7.2General................................
24
7.3Serviceoptions........................
24
7.4Extendedwarranty....................
24
7.5Serviceindicatorlamp................
25
7.6Serviceandmaintenanceschedule..
26
8Faulttracing.................................28
8.1General................................
28
8.2Safety..................................
28
ivTableofcontents190TEN-1049-H1307
8.3Faulttracinglist........................
28
9Technicalspecication....................30
9.1Dimensionsandservicespace.......
30
9.2Technicaldata.........................
31
9.3Sounddata.............................
32
10Scrapping....................................33
11ContactMunters............................34
190TEN-1049-H1307Tableofcontentsv
IceDry30
1Introduction
1.1General
Muntersmanufacturesawiderangeofefcientdehumidiersdesignedfordifferentusesandapplications.
PleasecontactyournearestMuntersofceifyouhaveanyquestionsregardingtheinstallationofyour
dehumidier,orvisitthewebsiteatwww .munters.com.
Theunitisinspectedandcheckedpriortoleavingthefactorytoguaranteeconsistentqualityandmaximum
reliability.Forproductdata,seesectionTechnicalspecication.
1.2Aboutthismanual
Thismanualiswrittenfortheuserofthedehumidier.Itcontainsnecessaryinformationforhowtoinstall
andusethedehumidierinasafeandefcientway.Readthroughthemanualbeforetheunitisinstalledand
used.
1.3Safetyandcautions
Everymeasurehasbeentakeninthedesignandmanufactureofthedehumidiertoensurethatitmeetsthe
safetyrequirementsofthedirectivesandstandardslistedintheECDeclarationofConformity.
Theinformationinthismanualincludessuggestionsforbestworkingpracticeandshallinnowaytake
precedenceoverindividualresponsibilitiesorlocalregulations.
Duringoperationandotherworkwithamachineitisalwaystheresponsibilityoftheindividualtoconsider:
Thesafetyofallpersonsconcerned.
Thesafetyoftheunitandotherproperty.
Theprotectionoftheenvironment.
Forinformationaboutthesafetysymbolsusedinthismanual,seesectionImportantuserinformation.
1Introduction190TEN-1049-H1307
IceDry30
W W
W
ARNING! ARNING!
ARNING!
-Theunitisnotintendedforuseinhazardous(classied)areaswhereexplosionsafetycompliantequipment
isrequired.
-Theunitmustnotbesplashedwithorimmersedinwater.
-Donotconnecttheunittoothermainsvoltagethanspeciedontheunit’sidenticationplate,seesectionMarking.
-Themainspowersupplyispermanentlyconnectedtothemainpowerswitchoftheunit.
-Donotoperatetheunitnearanyheat-generatingdevicesorammableanddangerousmaterials.
-Donotinsertngersoranyotherobjectsintotheairvents.
-Allelectricalinstallationsmustbecarriedoutbyaqualiedelectricianandinaccordancewithlocalregulations.
-Thedehumidiercanrestartautomaticallyafterapowercut.Alwayssetandlockthemainpowerswitchinthe
OFFpositionbeforecarryingoutanyservicework.
-Useonlyapprovedliftingequipmenttopreventaccidents.
-AlwayscontactMuntersforserviceorrepair.
190TEN-1049-H1307Introduction2
IceDry30
1.4Marking
Type
Fabr. No. 0914 190XXX XXXXX
3 ~ 400V 50 Hz
4,56 kW
Max
22,6 kW
Munters Europe AB
Isa fjords ga ta n 1
164 26 Kista , S we de n
M
IP33
Fabr. ye a r
18 kW
Ma de in S we de n
IceDry30
2009
Explanationof"Fabr.No"ontheidenticationplate:
09=yearofmanufacture,19=weekofmanufacture,190XXX=articlenumber,XXXXX=serialnumber
1.5Supervisionofoperation
Thedehumidieriscontrolledandmonitoredfromtheoperatorpanellocatedontheexternalelectrical
cabinet.
1.6Faultindications
Anyfaultsareindicatedthroughilluminationoftheredlampontheoperatorpanel.Fordetailed
information,seesection6.4.5,Window5,Alarm.
3Introduction190TEN-1049-H1307
IceDry30
2Productdesign
2.1Productdescription
ThedesiccantdehumidiersintheIceDryserieshavebeendevelopedtoeffectivelydehumidifytheairin
coldstoresinordertominimisefrostandicebuild-up
Thedehumidierisequippedwithanencapsulatedrotorunit.Therotorcasingisconstructedofdurable
thermosetplasticandcontainsisolatedsectionsthatprovideaprecisebalanceforthedehumidication,
reactivationandheatrecoveryairows.
TheelectricalcontrolsystemcomplieswiththeEN60204(IEC60204)standards.Foroperating
temperature,seesection9.2,Technicaldata.
ThedehumidierismanufacturedinaccordancewithuniformEuropeanstandardsandestablished
requirementsforCE-marking.
2.2Principleofoperation
2
1
4
3
Figure2.1Principleofoperation
1.Processair
2.Dryair
3.Reactivationair
4.Wetair
Thedesiccantrotorismadeofacompositematerialthatishighlyeffectiveinattractingandretainingwater
vapour.Therotorisdividedintwozones.Theairowtobedehumidied,processair,passesthrough
therotor'slargestzoneandthenleavestherotorasdryair.Sincetherotorrotatesslowly,theincomingair
alwaysmeetsadryzoneontherotor,thuscreatingacontinuousdehumidicationprocess.
Theairowthatisusedtodrytherotor,reactivationair,isheated.Thereactivationairpassesthrough
therotorintheoppositedirectiontotheprocessairandleavestherotoraswetair(warm,moistair).This
principleenablesthedehumidiertoworkeffectively,evenatfreezingtemperatures.
190TEN-1049-H1307Productdesign4
IceDry30
2.3Maincomponents
8
10
2
3
6
1
4
5
9
7
Figure2.2Maincomponents
1.Rotorsealring6.Lowerrotorcover
2.Rotor7.Reactivationfan
3.Upperrotorcover8.Processfanmotor
4.Reactivationheater9.Externalelectricalcabinet
5.Rotordrivemotor10.Processairlter
5Productdesign190TEN-1049-H1307
IceDry30
3Transport,inspectionandstorage
3.1Movingtheequipment
Thedehumidierisdeliveredonapalletandmustbehandledcarefully.Allpaneldoorsontheunitmustbe
closedduringtransport.Providedthatthedehumidierisstillsecuredtoitsdeliverypallet,itcanbemoved
usingafork-lifttruck.
Weightofthedehumidiercanbefoundinsection9.1,Dimensionsandservicespace.
3.2Packaginganddeliveryinspection
1.Checkthedeliveryagainstthedeliverynote,orderconrmationorotherdeliverydocumentationand
checkthateverythingisincludedandnothingisdamaged.
2.ContactMuntersimmediatelyifthedeliveryisnotcompleteinordertoavoidinstallationdelays.
3.Iftheunitistobeputintostoragepriortoinstallation,seesectionStoringtheequipment.
NOTE!Ifinstallationisnottobecarriedoutimmediatelyafterarrivaloftheequipment,itisadvisabletoleave
thepackagingmaterialinplaceonthedehumidier,ortore-usethepackagingmaterialtoprovidetemporary
protectionfortheunitduringlatertransportationtothesiteandduringinstallation.
4.Removeallpackagingmaterialfromtheunit,checkcarefullytomakesurethatnodamagehasoccurred
duringtransportation.
5.AnyvisibledamagemustbereportedinwritingtoMunterswithin5daysandpriortoinstallationof
theunit.
6.Disposeofthepackagingmaterialaccordingtolocalregulations.
NOTE!G3ltercartridgesforprocessandreactivationairareincludedinthedelivery.Onecartridgeismounted
onthedehumidierprocessairinletandoneontheoutsideofthecold-storageroom,inthereactivationairinlet.
3.3Storingtheequipment
Thefollowingisimportantifthedehumidieristobestoredpriortoinstallation:
Placethedehumidierinanuprightpositiononahorizontalsurface.
Protectthedehumidierfromphysicaldamage.
Storethedehumidierundercoverandprotectitfromdust,frost,rainandaggressivecontaminants.
190TEN-1049-H1307Transport,inspectionandstorage6
IceDry30
4Installation
4.1General
IceDrydehumidiersareintendedforinstallationincoldstoreswithambientairdowntominus25°C.
Theseconditionsrequirethatinstallationinstructionsarefollowedcarefullyasfaultyinstallationcanresult
inseriousoperationaldisturbances.
Iftheunitistobeputintostoragepriortoinstallation,seesection3.3,Storingtheequipment.
4.2Safety
W W
W
ARNING! ARNING!
ARNING!
Themainspowersupplyispermanentlyconnectedtothemainpowerswitchoftheunit.Adjustments,
maintenanceandrepairsmustonlybecarriedoutbyauthorisedpersonnel.
W W
W
ARNING! ARNING!
ARNING!
Thewetairoutletishot.Toavoidburnsfromunintendedcontact,makesureitisinsulated.
CA CA
CA
UTION! UTION!
UTION!
Thebuilt-inheaterrequiresacontinuouspowersupplytopreventfunctionaldisorder.Onlyswitchofftheunit's
powerincaseofemergency.
CA CA
CA
UTION! UTION!
UTION!
Condensationiseasilyformedontheinsideoftheductduetothehighhumidityofthereactivationair.Toavoid
condensation,theductworkmustbeinsulated
CA CA
CA
UTION! UTION!
UTION!
Activatethemainswitchforthedehumidierassoonastheunithasbeeninstalled.Thisallowsthebuilt-inheater
tooperateandpreventsinternaliceformation.
CA CA
CA
UTION! UTION!
UTION!
Beforestartingtheunit,thereactivationairinletandwetairoutletmustbethoroughlychecked.Anyicemustbe
removed.Toavoidmalfunction,itisimportanttohaveclearairpassagethroughouttheductwork.
CA CA
CA
UTION! UTION!
UTION!
Iftheprocessairowdamperisfullyopen,thehighcoldairdensityinthecold-storageroomcoulddamagethe
processairfan.
CA CA
CA
UTION! UTION!
UTION!
Failuretocorrectlyadjusttheprocessandreactivationairowscouldcausetheunittomalfunction.
4.3Siterequirements
Thedehumidierisadaptedtooperationinsidecoldstores.Thepermittedoperationaltemperatures
arefromminus25to0°C.Itisimportantthattheintendedinstallationsitemeetsthelocationandspace
7Installation190TEN-1049-H1307
IceDry30
requirementsfortheequipmentinordertoachievethebestpossibleperformanceandfacilitateservicing.
Therefore,complywiththerecommendedservicespaces,seesection9.1,Dimensionsandservicespace.
NOTE!Theunitmustberemovedfromthecoldstoreatcertainserviceintervals.Haveextracablesforunit
connectionavailable.
4.4Wheretoinstallthedehumidier
Selectaplacewherethedehumidiercausestheleastdisturbancetothecold-storageroomactivities,while
allowingformaintenanceworksuchasprocesslterreplacement.
Whentheunitisinstalledonabaseframe,thebaseframemustbedesignedinsuchawaythatitcaneasilybe
removedfromthecoldstore/freezer.Makesureopeningsforforkliftareincluded.
Thedehumidiermustbeplacedsothatthereisnoriskoftheprocessintakeandltericingup.Icenormally
formsnearthedoorsandair-locksofthecoldstorewherewarm,humidairowsin.
Installthedehumidierinsuchawaythatthereactivationairandwetairductsareasshortaspossible,max
1.5m.Seesection4.6,Installationexamplescoldstorageroom(freezer).
4.5Ducting
4.5.1Generalrecommendations
NOTE!Vibrationreduction.Ifthereisaneedtoforreductionofvibrationsfromthedehumidier,contactMunters
forinstructions.RefertostandardEN1299+A1:2008.
Duetothecoldsurroundingsandriskoffreezing,itisvitalthatallductingareinstalledaccordingto
instructions.Seealso4.6,Installationexamplescoldstorageroom(freezer).
Tofacilitateeasytransferofthedehumidieroutofthecold-storageroomforservice,allductconnections
shouldbeeasilydisassembled.Shouldthedehumidier,despitethisrecommendation,beinstalledinsucha
waythatitcannotbeeasilyremovedforservice,itisimportantthattheminimumservicespacerequirements
aremet,see9.1,Dimensionsandservicespace.Avapour-tightconnectionbetweenthewallandtheductisvital.
Preferably,polyurethanefoamshouldbeusedifthetemperatureissufcientlyhighduringapplication.
Wheninstallingductworkbetweenthedehumidierandtheinletandoutletconnections,thefollowing
recommendationsshouldbeobserved:
Thelengthofductworkshouldbekeptasshortaspossibletominimisestaticairpressurelosses.
Tomaintainperformance,allrigidprocessorreactivationairductworkjointsmustbeairandvapour
tight.
Thedesignoftheductconnectionsshouldfacilitateeasydisconnectionoftheunitforserviceoutside
thecold-storageroom.
Condensationeasilybuildsupontheinsideoftheductduetothehighhumidityofthereactivationair.
Toavoidcondensation,theductworkmustbeinsulated.
Theprocessairductworkshouldbeinsulatedtopreventcondensationfromdevelopingontheoutside
oftheductwheneverthetemperatureoftheairwithintheductfallsbelowthedewpointoftheambient
airthroughwhichtheductworkisrouted.
Thewetairleavingthedehumidierwilleasilycausecondensationontheinsideoftheductwallsdueto
thehighmoisturecontent.Thismustbeavoidedbyinsulatingtheducts.
190TEN-1049-H1307Installation8
IceDry30
Ensurethataccessforoperationandservicingisnotrestrictedwhendesigningandinstallingducting.
Formoreinformation,seesection9.1,Dimensionsandservicespace.
Toreducenoiseand/orvibrationbeingtransmittedalongrigidductwork,goodquality,airtightexible
connectionsshouldbetted.
Ductsmounteddirectlyontothedehumidiershouldbeadequatelysupportedtominimisetheloadand
stressduetotheweightandmovementoftheducting.
Dampersforbalancingtheairowmustbeinstalledinthereactivationairinletduct.Correctairows
areessentialformaintainingtheoperatingefciencyoftheunit.Forairowadjustmentdetails,see
section4.10,Airowcheckandadjustment.
Processairpressureandowareadjustedusingtheprocessairfan'sfrequencyconverter.Ifthisisthe
case,itisnotnecessarytohaveadamperinthedryairduct.
Thetotalresistanceintheprocessandreactivationductworkmustnotexceedtheperformancerating
ofthefansttedinthedehumidier.Fordetailsofminimumavailablestaticpressure,seechapter
9.2,Technicaldata.
4.5.2Processairinlet
Thedehumidierhasanexternallterboxfortheprocessairinlet.Ifthereisariskoftheprocessairlter
icingup,aductshouldbeconnectedtoretrieveprocessairfromadrylocation5-10metresfromthedoor
opening.Thelterboxcanthenbemovedtotheinletsideoftheduct.
4.5.3Dryairoutletduct
Channeloutthedryairfromthedehumidieranddistributeitsothatitmixeswiththewarm,humidairthat
normallyentersthecoldstoreabovethedoorsandair-locksthatareopenedregularly.Installanadjustable
damperintheduct.
4.5.4Reactivationairintake
Placethereactivationairintakeandlterboxoutsidethecoldstore.Mountthelterboxdirectlyonthewall.
Theducttothedehumidierreactivationairintakeshouldbeatmost1.5metreslong,andmustbeinsulated
topreventicebuild-up.Thisalsoappliestothesectionofductpassingthroughthewall.Anadjustable
damperisinstalledintheduct.
Topreventtheoutgoingwetairhumidifyingtheincomingreactivationair,thereactivationairintakemustbe
positionedatleast2metresfromthewetairoutlet
9Installation190TEN-1049-H1307
IceDry30
A.Reactivationair
B.Wetair
1.Filterbox
2.Condensatedrains
Figure4.1Inletforreactivationairandoutletforwetair.
3.Vapour-tightgrommet
4.5.5Ductworkforwetairoutlet
Thewetairductmustbemadeofplasticoranothercorrosionresistantmaterial.Itmustbeabletohandle
temperaturesbetween-30°Cand75°C,benomorethan1.5metreslongandbeinsulatedtopreventice
formation.Thisalsoappliestothepartoftheductpassingthroughthewall.
Becauseofitshighmoisturecontentthewetairleavingthedehumidierwillcondenseontheinsideof
theductwalls.Duetothelowambienttemperaturethereisariskoficeformation.Thewetairductmust
thereforebeinsulated.
Horizontalductsmustbeinstalledwithaslightdecline(awayfromthedehumidier)todrainaway
possiblecondensation.Thedeclinemustbeatleast2cm/mofduct.
5mmdrainholesshouldbemadeatlowpointsoftheducttopreventwateraccumulationintheduct.
Topreventtheoutgoingwetairfromhumidifyingtheincomingreactivationair,thewetairoutletmust
beplacedatleast2metresfromthereactivationinlet.SeeFigure4.1.
NOTE!Alwaysdrillthedrainholesontheoutsideofthecoldstorage/freezerroomwall.
W W
W
ARNING! ARNING!
ARNING!
Thewetairoutletishot.Toavoidburnsfromunintendedcontact,makesureitisinsulated.
190TEN-1049-H1307Installation10
IceDry30
4.6Installationexamplescoldstorageroom(freezer)
Muntersrecommendsthefollowinginstallations.Ifindoubt,contactMuntersforadvice.
Notetheservicespacerequirementsinsection9.1,Dimensionsandservicespace.
2 - 3 m
Figure4.2Positionbehindscreen.
5 - 10 m
Figure4.3Positionfarawayfromdoor/airlock.
11Installation190TEN-1049-H1307
IceDry30
5 - 10 m
Figure4.4Processairductfarawayfromdoor/airlock.
CA CA
CA
UTION! UTION!
UTION!
Activatethemainswitchforthedehumidierassoonastheunithasbeeninstalled.Thisallowsthebuilt-inheater
tooperateandpreventsinternaliceformation.
Theopeningsofinletandoutletductsmustbewellsealedduringinstallationandoperationstops,whenthe
dehumidierisnormallyswitchedoff.Thispreventsiceformationinductsanddehumidiercausedby
unintendedventilationandlowtemperatureinthecold-storageroom.
4.7Electricalconnections
W W
W
ARNING! ARNING!
ARNING!
Allelectricalinstallationsmustbecarriedoutbyaqualiedelectricianandinaccordancewithlocalregulations.
Allunitsaredeliveredcompletewithallinternalcablinginstalledandconguredtothevoltageand
frequencygivenontheIDplate.
NOTE!Supplyvoltagemustnotvarymorethan10%ofthespeciedoperatingvoltage.
Theunitmustbeadequatelyconnectedtoearth.
Forconnectiondetails,refertotheIDplate,Electricalcircuitdiagramsorsection9.2,Technicaldata.The
connectioncableandmainfusesmustbesuitabletotheunitbeinginstalled.
Connecttheunitwithaexiblecabletoawallmountedsocket.Thiswaytheunitcaneasilybedisconnected
fromthepowersupplybyremovingtheplugfromthesocket.
Thedehumidierisconnectedtotheexternalelectricalcabinetviathesuppliedcables(about10m)with
markedconnectors.Aspecialbracketisprovidedforwallmountingoftheexternalelectricalcabinet.
190TEN-1049-H1307Installation12
IceDry30
4.8Pre-startsettings
Ondeliverytheoperationalparametersaresetforuseinacoldstore.
Anumberofalternatives,tominimisetheriskofoperationaldisturbance,canbesetoninitialstart-up,see
section6,Controlsystem.
Theapplicationdoesnotrequiretheconnectionofexternalsensorsorexternalinput/outputsignals.
4.9Pre-startchecks
W W
W
ARNING! ARNING!
ARNING!
Themainpowersupplyispermanentlyconnectedtothemainpowerswitchoftheunit.Adjustments,maintenance
andrepairsmustonlybecarriedoutbyauthorisedpersonnel.
Beforestartingthedehumidierforthersttime,ensurethatthemainpowersupplyisisolatedfromthe
dehumidierandcarryoutthefollowingchecks:
1.MakesurethatthemodeselectorswitchonthedehumidierisintheOFFposition..
2.Makesurethattheairintakeltersareundamagedandproperlytted,andthatallareasinsidetheunit
arecleanandfreefromice.
3.Visuallyinspectallductingandductconnectionstomakesurethatallconnectionshavebeencorrectly
installedandthattherearenosignsofdamagetothesystem.Alsocheckthatallductsarefreefrom
obstaclesblockingtheairpassage.
4.Checkthattheincomingpowersupplyvoltageiscorrectandthatthecablesarecorrectlyconnected.
5.Afterconnectingtheprocessfantopower,checkthefanturningdirection.
6.Openthedehumidier'sfrontpanel.
7.Startthedehumidierandcheckthatthefanisturning.
8.Switchoffthedehumidierandcheckthefanjustbeforeitstops.Makesureithasaclockwiserotation
9.Makesurethattheunit'spowersupplyandmainswitchareonassoonastheunithasbeeninstalledinthe
cold-storageroom.Ifnot,checkifthereisiceintheunit.
10.Setthedamperforthereactivationairowfullyopen.
11.Setthedamperfortheprocessairow50%open.
CA CA
CA
UTION! UTION!
UTION!
Iftheprocessairowdamperisfullyopen,thehighcoldairdensityinthecold-storageroomcoulddamagethe
processairfan.
CA CA
CA
UTION! UTION!
UTION!
Beforestartingtheunit,thereactivationairinletandwetairoutletmustbethoroughlychecked.Anyicemustbe
removed.Toavoidmalfunction,itisimportanttohaveclearairpassagethroughouttheductwork.
13Installation190TEN-1049-H1307
IceDry30
4.10Airowcheckandadjustment
ContactMuntersServicefordehumidierinstallationandadjustment.TheaddressestoMunterscanbe
foundonthebackpageofthismanual.
CA CA
CA
UTION! UTION!
UTION!
Iftheprocessandreactivationairowsarenotproperlyadjusted,theunitcanmalfunction.Theairowmustbeset
tomaximum10%abovethespeciednominalvaluelistedinsection9.2,Technicaldata.
1.Byadjustingthedampersinstalledinthedryairoutletandreactivationairinletducts,theprocessand
reactivationairowscanbechangedtotherequiredsetting.
2.Startthedehumidierforapproximately10minutestoallowthereactivationheatertoreachitsnormal
operatingtemperature.Seesection5.5,Operatingtheunit.
3.Checkthatthetemperaturedifferencebetweenreactivationairdownstreamoftheheater,andthe
regenerationtemperatureisapprox.95°C(tolerancelimitis±5°C).
4.Ifthetemperaturedifferenceliesoutsideofthetolerancelimit,thereactivationairdampercanbe
adjustedinsmallsteps(whichcausesthetemperatureindicatortostabiliseaftereachadjustment)until
reactivationtemperatureiswithinthespeciedtolerances.
Example:
Inletairtemperature=15°C
Reactivationairtemperature=110°C
Temperatureincrease=95°C
190TEN-1049-H1307Installation14
IceDry30
5Operation
5.1General
Thedehumidierisequippedwithanexternalelectricalcabinetcontainingcontrolpanel,mainpower
switch,modeswitch,displayandindicatorlamps.
Themodeswitchhastwooperatingpositions:
Position0:Nodehumidication.Theheaterintheelectricalcabinetandthereactivationheaterisstillin
operationtoavoidiceformation.Anautomaticrotordefrosterfunctionmaystillbeinoperation,see
section5.6.2,Duringdowntime.
Position1:Continuousoperationanddehumidication.Automaticrotordefrostingisnormalduring
operation,seesection5.6.1,Duringoperation.
5.2Safety
W W
W
ARNING! ARNING!
ARNING!
Inthecaseofapowercut,thedehumidierwillrestartautomaticallywhenthepowersupplyisrestored.
CA CA
CA
UTION! UTION!
UTION!
Atinitialstart-uporwhenrestartingafteraservicestop,themainpowerswitchmusthavebeenonforatleast12
hoursbeforestarting.Thisisnecessarytoremoveanyicebuild-upinsidetheunit.
CA CA
CA
UTION! UTION!
UTION!
Beforestartingtheunit,thereactivationairinletandwetairoutletmustbethoroughlychecked.Anyicemustbe
removed.Toavoidmalfunction,itisimportanttohaveclearairpassagethroughouttheductwork.
CA CA
CA
UTION! UTION!
UTION!
Topreventdamagetothefans,theunitmustnotberunforlongerthanafewminutespriortosetting-uptheprocess
andreactivationairows.
CA CA
CA
UTION! UTION!
UTION!
Donotturnoffthemainpowerswitch.Thiscanleadtoiceformationandmalfunctionofthedehumidier.
5.3Quickstop
Themodeswitchisusedtostartandstoptheunitinnormaloperation.Incaseofanemergency,usethemain
powerswitchonthedehumidier,seesection5.4,Externalelectricalcabinet.
CA CA
CA
UTION! UTION!
UTION!
Onlyusethemainpowerswitchtostoptheunitinthecaseofanemergency.Thenormalshutdownsequencewill
notbefollowed.Thefansstopandtheheatercanbeveryhot,whichcanresultindamagetotheheaterandother
componentsclosetoit.
15Operation190TEN-1049-H1307
/