![](//vs1.manuzoid.com/store/data-gzf/f0e73585a1b2a67b4152e1945b0141f6/2/002334861.htmlex.zip/bg1.jpg)
Summary Specifications
The light-control switch can turn on and turn off light automatically
according to ambient light; it is not affected by ambient
temperature and humidity; It is not only convenient but also
practical; it can control the load that works at night.
LX-P09 Light-Control Sensor Instruction
Notice
1.In front of the light-control switch there should be no block affecting it to receive natural light;
2.In front of the light-control switch there should be no swaying object;
3.Avoid installing the unit below light.
Test
1.Use opaque to cover the sense-light window when testing in the daytime.
2.When cover this opaque, the load will be on .
3.When take off this opaque, the load will be off.
4.Take off this opaque after testing.
Connection-wire diagram
Connect blue and brown with power
Connect blue and red with load
Brown
Blue Red
~input output
Light-Control
Switch
Load
www.lexing.com.cn
20mm
43.3mm
35.6mm
35.6mm
78.8mm
40.8mm
Correct installation
Wrong installation
φ3mm
Power Source: 220-240VAC
Power frequently: 50Hz
Rated Current: 6A(pure resistance load)
Light-control: Load on 10LUX
Load off 30LUX
Installation