Lexing LX-P09 Operating instructions

  • I have reviewed the LX-P09 Light-Control Sensor Instruction manual. This document provides instructions on how to install, test and use the light control sensor, highlighting its automatic light control feature and its ability to manage night loads unaffected by weather. I’m ready to answer your questions based on information found in the document.
  • How does the light-control switch work?
    What are the light level thresholds for activation and deactivation?
    How should I test the light-control switch?
    What should I avoid during installation?
Summary Specifications
The light-control switch can turn on and turn off light automatically
according to ambient light; it is not affected by ambient
temperature and humidity; It is not only convenient but also
practical; it can control the load that works at night.
LX-P09 Light-Control Sensor Instruction
Notice
1.In front of the light-control switch there should be no block affecting it to receive natural light;
2.In front of the light-control switch there should be no swaying object;
3.Avoid installing the unit below light.
Test
1.Use opaque to cover the sense-light window when testing in the daytime.
2.When cover this opaque, the load will be on .
3.When take off this opaque, the load will be off.
4.Take off this opaque after testing.
Connection-wire diagram
Connect blue and brown with power
Connect blue and red with load
Brown
Blue Red
~input output
Light-Control
Switch
Load
www.lexing.com.cn
20mm
43.3mm
35.6mm
35.6mm
78.8mm
40.8mm
Correct installation
Wrong installation
φ3mm
Power Source: 220-240VAC
Power frequently: 50Hz
Rated Current: 6A(pure resistance load)
Light-control: Load on 10LUX
Load off 30LUX
Installation
/