WaterWorks RG2T01 Installation guide

Category
Sanitary ware
Type
Installation guide
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 1 OF 1 | UPDATED ON 11.17.2023
INSTALLATION GUIDELINES
THERMOSTATIC SHOWER SYSTEM
REGULATOR THERMOSTATIC CONTROL VALVE TRIM REGULATOR TWO WAY DIVERTER VALVE TRIMS
REGULATOR THREE WAY DIVERTER VALVE TRIMSREGULATOR VOLUME CONTROL
STYLES
RGTH01 RGTH02 [SHOWN] RGTH10 RGTH11 [SHOWN]
STYLES
RG2T01 RG2T02 [SHOWN] RG2T10 RG2T11 [SHOWN]
STYLES
RG3T01 RG3T02 [SHOWN] RG3T10 RG3T11 [SHOWN]
STYLES
RGVC01 RGVC02 [SHOWN] RGVC10 RGVC11 [SHOWN]
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 2 OF 15 | UPDATED ON 11.17.2023
INSTALLATION GUIDELINES
THERMOSTATIC SHOWER SYSTEM
IMPORTANT:
ALL VALVES AND TRIMS SOLD SEPARATELY.
To ensure theses product are installed properly, you must read
and follow these guidelines.
The owner/user of these products must keep this information
for future reference.
These products must be installed by a professional licensed
contractor and must be on-site prior to rough-in. This allows
the installer to visualize the installation.
Refer to the Installation Guidelines provided with each
VALVE for complete rough-in installation details and related
information.
Be sure your installation conforms to all federal, state, and
local codes. In the State of Massachusetts, all installations
must comply with the rules and regulations set forth within
248 CMR.
WARNING: The THERMOSTATIC VALVES (GUTH60/GUTH37)
feature anti-scald protection. The risk of scalding exists until
the installer has properly calibrated/adjusted the temperature
setting during final TRIM installation.
These products are sold partially assembled but shown fully
disassembled for illustrative and service purposes only.
Inspect these products to ensure you have all the parts
required for proper installation.
Use only a strap wrench or protected/smooth-jaw wrench on
any finished surface.
The use of certain plumber’s putty may stain stone or tile
surfaces.
If further assistance is required, please contact Product
Support at 1-800-927-2120 Monday through Friday, 8am –
6pm EST.
Refer to the separate Service Parts Documents for available
replacement parts.
VALVE FUNCTION:
THERMOSTATIC VALVES only mix hot and cold water and do
not have volume or shut-off capabilities.
VOLUME CONTROL VALVES controls on/off/volume and must
be installed for each fitting that will have water flowing to it
or a DIVERTER VALVE for multiple fittings.
REQUIRED PLUMBING DETAILS:
Depending on the number of end fittings in the shower system and how many are able to
operate SIMULTANEOUSLY, the system will require either:
A. GUTH60 system for a MAXIMUM of 2 fittings flowing simultaneously or,
STYLE NUMBER OF
OUTLETS
INLET/OUTLET
CONNECTIONS
THERMOSTATIC
VALVE GUTH60 2 1/2” MALE NPT
VOLUME
CONTROL
VALVE
GUVC18
1 1/2” FEMALE NPT
GUVC19
DIVERTER
VALVE
GUDV2T
[SHOWN] 2 1/2” MALE NPT
GUDV3T 3 1/2” MALE NPT
B. GUTH37 system for 3+ fittings flowing simultaneously.
STYLE NUMBER OF
OUTLETS
INLET/OUTLET
CONNECTIONS
THERMOSTATIC
VALVE GUTH37 2 3/4”
FEMALE NPT
VOLUME
CONTROL
VALVE
GUVC16
13/4”
FEMALE NPT
GUVC17
DIVERTER
VALVE
GUDV2T
[SHOWN] 21/2”
MALE NPT
GUDV3T 3 1/2” MALE NPT
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 3 OF 15 | UPDATED ON 11.17.2023
INSTALLATION GUIDELINES
THERMOSTATIC SHOWER TRIM WITH GUTH60
ROUGH-IN AND VALVE PREPARATION:
TOP OUTLET
[1/2" MALE NPT] 15/16"
[24mm]
CARTRIDGE - INLET
ON-CENTER
SPREAD
OPTIONAL OUTLET
[1/2" MALE NPT]
CAUTION: The rough-in depth is measured from the centerline of the
inlets to the surface of the finished wall. If the VALVE is roughed-in
too shallow, the TRIM cannot be installed correctly.
The VALVE is shipped with a pre-installed FLUSH PLATE and is ready
for flushing the supply lines.
CAUTION: Before installing the THERMOSTATIC CARTRIDGE, the
supply lines MUST BE flushed out to prevent clogging of the FILTER
SCREENS. Failure to flush the lines will permanently damage the
CARTRIDGE and VOID the warranty. Repeat the flushing process
as needed prior to final TRIM installation.
Remove and discard the TILE GUARD only when the finished wall
surface (TILE or SLAB) is completed and the TRIM is ready for
installation.
THREADED
TUBE
RETAINING
NUT
FINISHED
WALL
CARTRIDGE
TILE
GUARD
NUT
[DO NOT
REMOVE]
"B"
FITTINGS
HOLE
"A"
ROUGH-IN
DEPTH
CENTERLINE
OF INLET
FLUSH PLATE
[PRE-INSTALLED]
[CLOSE]
[OPEN]
SERVICE
STOP SCREW
(x2)
DIMENSION VALUE
A4-1/2” [114mm] MAX
3-5/8” [92mm] MIN
B Ø2-1/2” [64mm]
IMPORTANT: The CARTRIDGE,
RETAINING NUT, and THREADED
TUBE are packaged separately
and provided with the VALVE.
SET ASIDE UNTIL FINAL TRIM
INSTALLATION!
A replacement THERMOSTATIC
CARTRIDGE KIT (STYLE No.
100219) can be ordered separately.
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 4 OF 15 | UPDATED ON 11.17.2023
INSTALLATION GUIDELINES
THERMOSTATIC SHOWER TRIM WITH GUTH60
FINISHED
WALL
THERMOSTATIC
CARTRIDGE
RETAINING NUT
[HAND TIGHTEN -
27mm HEX]
FINISHED
WALL
THREADED
TUBE
RETAINING
NUT
MARK LINE
FLUSH WITH
FINISHED WALL
THREADED TUBE
1. Turn on the water supplies then remove the TILE
GUARD from the VALVE and OPEN the SERVICE
STOPS (hot & cold) to flush out the lines.
CAUTION: FAILURE TO FLUSH THE
SUPPLY LINES WILL PERMANENTLY
DAMAGE THE CARTRIDGE AND VOID
THE WARRANTY! REPEAT THE FLUSHING
PROCESS AS NEEDED BEFORE FINAL
TRIM INSTALLATION.
2. After the lines have been fully flushed, CLOSE the
SERVICE STOPS (hot & cold) then unthread and
remove the FLUSH PLATE.
NOTE: DO NOT discard the FLUSH PLATE.
3. Insert the THERMOSTATIC CARTRIDGE into the
VALVE BODY then thread and hand-tighten the
RETAINING NUT into the VALVE BODY.
4. Thread the THREADED TUBE into the RETAINING
NUT until snug.
5. Mark the THREADED TUBE where it protrudes past
the finished wall.
NOTE: A straight edge (not supplied) can be used
to mark the TUBE.
FINISHED
WALL
TILE GUARD
SERVICE STOP
[OPEN - HOT & COLD]
FLATHEAD
SCREWDRIVER
* TURN ON WATER SUPPLY
AND FLUSH OUT SUPPLIES.
FINISHED
WALL
FLUSH PLATE
[17mm HEX]
SERVICE STOP
[CLOSE - HOT & COLD]
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 5 OF 15 | UPDATED ON 11.17.2023
INSTALLATION GUIDELINES
THERMOSTATIC SHOWER TRIM WITH GUTH60
MARK LINE
FLUSH WITH
FINISHED WALL
CARTRIDGE STEM
[THERMOSTATIC]
THERMOSTATIC
CARTRIDGE
RETAINING
NUT
(TORQUE-
12-14 ft-lb
[15-20 N-m])
THERMOSTATIC
CARTRIDGE
RETAINING
NUT
[27mm HEX]
10. Insert the CARTRIDGE back into the VALVE BODY,
thread and securely tighten the RETAINING NUT
to the specified torque settings shown, and thread
the TUBE back into the NUT until snug
11. Open the SERVICE STOPS (hot & cold) and check
for leaks then thread the THREADED TUBE back
into the RETAINING NUT until snug.
PROCEED TO TRIM INSTALLATION ON PAGE 9.
[PREVIOUS
MARK]
CUT MARK
THREADED
TUBE
CARTRIDGE
STEM
CUT MARK
[PREVIOUS
MARK]
LIMIT
STOP
PIN
LIMIT
STOP
O-RING
THREADED
TUBE
CHECK
FOR
LEAKS!
SERVICE STOP
[OPEN - HOT & COLD]
FLATHEAD
SCREWDRIVER
7/ 8 ”
[22mm]
1-1/2”
[38mm]
6. Remove the THREADED TUBE then cut it 7/8”
[22mm] in front of the previous mark so the TUBE
will protrude 7/8” [22mm] from the finished wall
surface.
7. Mark the CARTRIDGE STEM where it protrudes
past the finished wall.
8. Unthread the RETAINING NUT and remove the
CARTRIDGE.
9. Carefully cut the CARTRIDGE STEM 1-1/2” [38mm]
in front of the previous mark so the STEM will
protrude 1-1/2” [38mm] from the finished wall
surface then remove the O-RING and LIMIT STOP
from the CARTRIDGE.
NOTE: The LIMIT STOP is NOT required since the
TRIM PLATE has a LIMIT STOP.
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 6 OF 15 | UPDATED ON 11.17.2023
INSTALLATION GUIDELINES
THERMOSTATIC SHOWER TRIM WITH GUTH37
FINISHED WALL
FLUSH PLATE
[PRE-INSTALLED,
DO NOT
DISCARD]
VALVE BODY
CARTRIDGE
TILE GUARD
SERVICE
STOP
“A”
ROUGH-IN
DEPTH
"B"
FITTINGS
HOLE
IMPORTANT: The THERMOSTATIC
CARTRIDGE is packaged
separately and provided with the
VALVE. SET ASIDE UNTIL FINAL
TRIM INSTALLATION!
A replacement THERMOSTATIC
CARTRIDGE (STYLE No. 855191)
can be ordered seperately.
CARTRIDGE
ROUGH-IN AND VALVE PREPARATION:
SUPPORT
TABS
(x2)
TOP OUTLET
BOTTOM OUTLET
[PLUGGED]
COLD
[BLUE]
HOT
[RED]
SERVICE STOP
(x2)
FLUSH PLATE
[PRE-INSTALLED]
13/16"
[21mm]
CARTRIDGE-INLET
ON-CENTER
SPREAD
CAUTION: The rough-in depth is measured from the centerline of the
inlets to the surface of the finished wall. If the VALVE is roughed-in
too shallow, the TRIM cannot be installed correctly.
The VALVE is shipped with a pre-installed FLUSH PLATE and is ready
for flushing the supply lines.
CAUTION: Before installing the THERMOSTATIC CARTRIDGE, the
supply lines MUST BE flushed out to prevent clogging of the FILTER
SCREENS. Failure to flush the lines will permanently damage the
CARTRIDGE and VOID the warranty. Repeat the flushing process
as needed prior to final TRIM installation.
Remove and discard the TILE GUARDS only when the finished wall
surface (TILE or SLAB) is completed and the TRIM is ready for
installation.
DIM VALUE
A8” [203mm] MAX
2-1/2” [64mm] MIN
B Ø5-1/4” [133mm]
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 7 OF 15 | UPDATED ON 11.17.2023
INSTALLATION GUIDELINES
THERMOSTATIC SHOWER TRIM WITH GUTH37
1. Turn on the water supplies then remove the TILE
GUARDS from the VALVE and OPEN the SERVICE
STOPS (hot & cold) to flush out the lines.
CAUTION: FAILURE TO FLUSH THE
SUPPLY LINES WILL PERMANENTLY
DAMAGE THE CARTRIDGE AND VOID
THE WARRANTY! REPEAT THE FLUSHING
PROCESS AS NEEDED BEFORE FINAL
TRIM INSTALLATION.
2. After the lines have been fully flushed, CLOSE the
hot and cold SERVICE STOPS then unthread the
SCREWS and remove the FLUSH PLATE.
3. Insert the CARTRIDGE into the VALVE BODY then
thread and securely tighten the SCREWS, re-open
the SERVICE STOPS, and check for leaks.
FINISHED WALL
TILE
GUARD
SERVICE STOP
[OPEN - HOT & COLD]
FLATHEAD
SCREWDRIVER
[NOT SUPPLIED]
* TURN ON WATER SUPPLY
AND FLUSH OUT SUPPLIES.
[PREVIOUS
MARK]
1-1/4”
[32mm]
CUT MARK
THREADED TUBE
[DO NOT CUT END
WITH INTERNAL
THREADS]
4. Fully thread the THREADED TUBE onto the
CARTRIDGE STEM and mark the TUBE where it
protrudes past the finished wall.
NOTE: A straight edge (not supplied) can be used
to mark the TUBE.
5. Remove the THREADED TUBE then cut it 1-1/4”
[32mm] in front of the previous mark so the TUBE
will protrude 1-1/4” [32mm] from the finished wall
surface.
CAUTION: Do NOT cut the end with the internal
threads.
FLUSH
PLATE
[DO NOT
DISCARD]
SCREW WITH O-RING
[DO NOT DISCARD]
SERVICE STOP
[CLOSE - HOT
& COLD]
CARTRIDGE
[EXTERNAL
O-RING]
SCREW
WITH
O-RING
SERVICE STOP
[OPEN - HOT & COLD]
CARTRIDGE
STEM
THREADED
TUBE
MARK LINE
FLUSH WITH
FINISHED WALL
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 8 OF 15 | UPDATED ON 11.17.2023
INSTALLATION GUIDELINES
THERMOSTATIC SHOWER TRIM WITH GUTH37
CARTRIDGE
STEM
SQUARE
TUBE
THREADED
TUBE
CARTRIDGE
STEM
SQUARE
TUBE
MARK LINE
FLUSH WITH
FINISHED WALL
SQUARE
TUBE
[PREVIOUS
MARK]
15/16”
[24mm]
CUT MARK
7. Remove the SQUARE TUBE then cut it 15/16”
[24mm] in front of the previous mark so the TUBE
will protrude 15/16” [24mm] from the finished wall
surface.
8. Slide the SQUARE TUBE onto the CARTRIDGE
STEM then thread the THREADED TUBE onto the
STEM until snug.
PROCEED TO TRIM INSTALLATION ON PAGE 9.
6. Insert the SQUARE TUBE onto the CARTRIDGE
STEM and mark the TUBE where it protrudes past
the finished wall.
NOTE: A straight edge (not supplied) can be used
to mark the TUBE.
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 9 OF 15 | UPDATED ON 11.17.2023
INSTALLATION GUIDELINES
THERMOSTATIC SHOWER TRIM
5. With water running, slowly rotate the TRIM NUT
STEM to adjust the temperature to the maximum
desired bathing temperature, verified with a
thermometer, then turn the water off and make
sure NOT to change this setting.
1. Determine the desired TRIM PLATE orientation
and position the appropriate ALIGNMENT HOLE
vertically at 6 o’clock.
NOTE: Do NOT remove the 6 SCREWS on the
PLATE. They are AESTHETIC only.
3. Slide the TRIM PLATE, in the desired orientation,
over the ALL THREAD TUBE, then thread and
securely tighten the TRIM NUT onto the TUBE and
secure TRIM NUT using SCREW provided.
NOTE: ROTATING THE TRIM NUT STEM WILL
HELP PROPERLY ALIGN IT WITH THE SQUARE
TUBE USED ON THE GUTH37.
2. Remove the LIMIT STOP COLLAR from the TRIM
NUT.
6. Slide the LIMIT STOP COLLAR back down the TRIM
NUT STEM making sure to properly align it with the
LIMIT STOP PIN and press down firmly.
NOTE: Pressing down firmly on the COLLAR will
engage the O-RING is fully seated in its groove
which will keep the collar securely in place.
4. With water running, slowly rotate the TRIM NUT
STEM clockwise to attain full cold then rotate it
counter-clockwise to attain full hot. Verify that a
full range of temperatures exists.
NOTE: It’s approximately 2 complete rotations for
the GUTH37 and 1 rotation for the GUTH60.
TRIM NUT
STEM
[COLD]
[HOT]
*WITH WATER RUNNING
>2I:>F>
MINIMUM
TEMP °C/°F
X1
TURN
GUTH60
X2
TURN
GUTH37
TRIM NUT
STEM
DESIRED MAX
TEMP °C/°F
*WITH WATER RUNNING
TRIM NUT
O-RING
LIMIT STOP COLLAR
[DO NOT REMOVE]
ALL THREADED
TUBE
TRIM PLATE †
TRIM NUT
[25mm HEX]
† A GASKET for the TRIM PLATE is provided.
If desired, a bead of caulk or a clear silicone may be
applied where the PLATE contacts the finished wall.
SCREW
LIMIT STOP
COLLAR
LIMIT STOP
PIN
LIMIT STOP
COLLAR
[ALIGNMENT]
’SNAP’
POSITION
"A"
POSITION
"B"
[6 O'CLOCK
POSITION] [6 O'CLOCK
POSITION]
ALIGNMENT
HOLE "A"
ALIGNMENT
HOLE "B"
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 10 OF 15 | UPDATED ON 11.17.2023
INSTALLATION GUIDELINES
THERMOSTATIC SHOWER TRIM
7. Turn the TRIM NUT STEM clockwise to full cold
then counterclockwise until snug and verify the
maximum desired bathing temperature set in the
previous step.
WARNING: It is NOT recommended to
exceed a safety limit stop of 37.8°C/100°F.
CAUTION: IF THE MAXIMUM BATHING
TEMPERATURE IS NOT CORRECT OR
NEEDS TO BE ADJUSTED, REMOVE
THE LIMIT STOP COLLAR AND REPEAT
STEPS 2 TO 7 TO RE-CALIBRATE THE
TEMPERATURE SETTING.
10. Operate the HANDLE to ensure that it is functioning
properly.
SERVICING ONLY:
1. A small notch is located at the bottom of the
FACEPLATE to help in removing the PLATE during
servicing.
8. Align the SET SCREW on the back of the
FACEPLATE with the ALIGNMENT HOLE at
6 o’clock on the TRIM PLATE then push the
FACEPLATE into the TRIM PLATE making sure it is
fully seated.
9. Place the HANDLE onto the HANDLE STEM in the
desired orientation and secure with the SCREW
provided.
NOTE: WHEEL HANDLES have a finished WASHER
and LEVER HANDLES have a CAP to conceal the
SCREW.
2. TURN UNTIL STOP
AND CHECK MAX
TEMP °C/°F
1. TURN FULL
COLD
WARNING:
It is NOT recommended to
exceed a safety limit stop
of 37.8 °C/100°F
TRIM NUT
STEM
FACEPLATE
[EXTERNAL
O-RINGS]
FACEPLATE
[BACK VIEW]
SET SCREW
[6 O'CLOCK POSITION]
ALIGNMENT
HOLE
HANDLE STEM
WHEEL HANDLE
HEX
WASHER
SCREW
LEVER HANDLE
SCREW INDICE
[WITH
O-RING]
SLOT
[USED FOR SERVICING]
FACEPLATE
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 11 OF 15 | UPDATED ON 11.17.2023
INSTALLATION GUIDELINES
VOLUME CONTROL TRIM WITH GUVC16/17/18/19
2. Remove the THREADED TUBE then cut it 1”
[25mm] in front of the previous mark so the TUBE
will protrude 1” [25mm] from the finished wall
surface.
NOTE: Do NOT cut the end of the THREADED
TUBE with the female threads.
3. Mark the CARTRIDGE STEM where it protrudes
past the finished wall.
NOTE: A straight edge (not supplied) can be used
to mark the CARTRIDGE STEM.
1. Remove the TILE GUARD when ready to install the
TRIM then mark the THREADED TUBE where it
protrudes past the finished wall.
NOTE: A straight edge (not supplied) can be used
to mark the TUBE.
O-RING
TILE
GUARD
[MARK LINE
FLUSH WITH
7:?:D965H2==N
THREADED
TUBE [PREVIOUS
MARK]
CARTRIDGE
STEM
[MARK LINE
FLUSH WITH
FINISHED WALL]
1”
[25mm]
CUT MARK
THREADED TUBE
[DO NOT CUT END
WITH INTERNAL
THREADS
VOLUME CONTROL
VALVE
[GUVC16 SHOWN]
O-RING
TILE GUARD
CENTERLINE
OF INLET
"B"
FITTINGS
HOLE
"A"
ROUGH-IN
DEPTH
FINISHED
WALL
CAUTION: The rough-in depth is measured
from the centerline of the inlets to the surface
of the finished wall. If the VALVE is roughed-
in too shallow, the TRIM cannot be installed
correctly.
Remove and discard the TILE GUARD only
when the finished wall surface (TILE or
SLAB) is completed and the TRIM is ready
for installation.
DIM VALUE
A4-5/8”[117mm] MAX
2-7/8” [73mm] MIN
B Ø1-3/8” [35mm]
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 12 OF 15 | UPDATED ON 11.17.2023
INSTALLATION GUIDELINES
VOLUME CONTROL TRIM WITH GUVC16/17/18/19
HANDLE
[DO NOT ROTATE
MORE THAN(>)
25 DEGREES]
HANDLE
[PROPERLY
ALIGNED]
HANDLE
HANDLE
[MISALIGNMENT]
[OPEN]
[OFF]
4. Remove the CARTRIDGE using a 21/32” [17mm]
shower valve socket wrench (not supplied) then
cut the CARTRIDGE STEM 1-3/4” [44mm] in front
of the previous mark so the STEM will protrude
1-3/4” [44mm] from the finished wall surface.
GUVC18 & GUVC19 ONLY:
5. Thread and securely tighten the CARTRIDGE back
into the VALVE.
STEPS 6 - 10 GUVC16 & GUVC17 ONLY: HANDLE
ALIGNMENT.
6. After cutting the CARTRIDGE STEM, unthread
the BONNET from the CARTRIDGE if not already
disassembled when removing from the VALVE.
7. Using the HANDLE, thread the CARTRIDGE
back into the VALVE until there is NOTICEABLE
resistance.
NOTE: Ensure the O-RING on the CARTRIDGE has
not been damaged and is properly seated.
8. Remove and replace the HANDLE to position it as
close as possible to the “OFF” position then turn
the HANDLE a 1/4 turn to the “OPEN” position
making sure NOT to unthread the CARTRIDGE.
9. If needed, carefully continue to rotate the HANDLE
counter-clockwise to obtain the proper alignment.
Do NOT rotate/unthread the CARTRIDGE more
than 25 degrees.
NOTE: Repeat Steps 7 & 8 if the CARTRIDGE is
unthreaded too far.
CARTRIDGE
[PREVIOUS
MARK]
CARTRIDGE
CARTRIDGE
BONNET
CARTRIDGE
[PRE-CUT]
HANDLE*
* DO NOT OVER TIGHTEN!
O-RING
1-3/4”
[44mm]
CUT MARK
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 13 OF 15 | UPDATED ON 11.17.2023
INSTALLATION GUIDELINES
VOLUME CONTROL TRIM WITH GUVC16/17/18/19
15. Turn on the water supply and operate the HANDLE
to ensure that it is functioning properly.
14. Place the HANDLE onto the HANDLE STEM in the
desired orientation and secure with the SCREW
provided.
NOTE: WHEEL HANDLES have a finished WASHER
and LEVER HANDLES have a CAP to conceal the
SCREW.
13. Thread and securely tighten the ESCUTCHEON
onto the TUBE using the O-RING provided. Place
the HANDLE STEM on CARTRIDGE then Push the
GLAND COVER onto the ESCUTCHEON until it is
FULLY seated, rotate it to the desired orientation,
and securely tighten the SET SCREW.
10. Remove the HANDLE then thread and securely
tighten the BONNET back onto the CARTRIDGE.
NOTE: The BONNET requires a torque between 15
and 18 ft-lb [21-24 N•m].
11. Thread and securely tighten the THREADED TUBE
back onto the CARTRIDGE until snug.
12. Loosen, but do NOT remove, the SET SCREW on
the backside of the GLAND COVER then remove
the GLAND COVER.
IMPORTANT: Do NOT use the GLAND COVER as
leverage to install the ESCUTCHEON.
CARTRIDGE
BONNET
(TORQUE: 15 to 18 ft-lb
[21 to24 N•m])
THREADED
TUBE
SET SCREW GROOVE
SET SCREW
[2mm HEX]
ESCUTCHEON
GLAND
COVER
O-RING †
THREADED
TUBE
CARTRIDGE
ESCUTCHEON
[WITH GASKET]
HANDLE STEM
GLAND
COVER
SET SCREW
[2mm HEX]
† An O-RING for the ESCUTCHEON is provided.
If desired, a bead of caulk or a clear silicone
may be applied where the ESCUTHEON
contacts the finished wall.
HANDLE
STEM
HANDLE
HEX
WASHER
SCREW
LEVER
HANDLE
INDICE
[WITH
O-RING]
SCREW
* TURN ON WATER
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 14 OF 15 | UPDATED ON 11.17.2023
INSTALLATION GUIDELINES
DIVERTER TRIM WITH GUDV2T/3T/66
1. Remove the TILE GUARD when ready to install the
TRIM then mark the THREADED TUBE where it
protrudes past the finished wall.
NOTE: A straight edge (not supplied) can be used
to mark the TUBE.
2. Remove the THREADED TUBE then cut it 1-1/8”
[29mm] in front of the previous mark so the TUBE
will protrude 1-1/8” [29mm] from the finished wall
surface.
3. Mark the CARTRIDGE STEM where it protrudes
past the finished wall.
NOTE: A straight edge (not supplied) can be used
to mark the CARTRIDGE STEM.
TILE
GUARD
[MARK LINE
FLUSH WITH
FINISHED WALL]
THREADED
TUBE
CARTRIDGE
STEM
[MARK LINE
FLUSH WITH
FINISHED WALL]
THREADED
TUBE
[PREVIOUS
MARK]
DIVERTER VALVE
[GUDV2T SHOWN]
TILE GUARD
CENTER
OF
INLET
"B"
FITTINGS
HOLE
"A"
ROUGH-IN
DEPTH
CAUTION: The rough-in depth is measured
from the centerline of the inlets to the surface
of the finished wall. If the VALVE is roughed-
in too shallow, the TRIM cannot be installed
correctly.
The DIVERTER VALVE TRIM components (i.e.
HANDLE and TRIM PLATE) are packaged
separately from each other.
Remove and discard the TILE GUARD only
when the finished wall surface (TILE or
SLAB) is completed and the TRIM is ready
for installation.
DIM VALUE
A4-1/2” [114mm] MAX
2-1/8” [54mm] MIN
B Ø2-1/2” [64mm]
1-1/8”
[29mm]
CUT MARK
PRODUCT SUPPORT | 800.927.2120 | WATERWORKS.COM PAGE 15 OF 15 | UPDATED ON 11.17.2023
INSTALLATION GUIDELINES
DIVERTER TRIM WITH GUDV2T/3T/66
ESCUTCHEON
GLAND COVER
SET SCREW
ESCUTCHEON
GLAND COVER
SET SCREW
O-RING
THREADED
TUBE
RUBBER GASKET
DIVERTER
PLATE †
ESCUTCHEON
† A GASKET for the DIVERTER PLATE is
provided. If desired, a bead of caulk or a
clear silicone may be applied where the
PLATE contacts the finished wall.
CARTRIDGE
STEM
HANDLE
STEM
GLAND COVER
[INTERNAL O-RINGS]
SET SCREW
[2mm HEX]
HANDLE
STEM
HANDLE
HEX WASHER
SCREW
SCREW
INDICE
[WITH O-RING]
SCREW
LEVER
HANDLE
9. Place the HANDLE onto the HANDLE STEM in the
desired orientation and secure with the SCREW
provided.
NOTE: WHEEL HANDLES have a finished WASHER
and LEVER HANDLES have a CAP to conceal the
SCREW.
8. Place the HANDLE STEM on the VALVE STEM, then
place the GLAND COVER onto the ESCUTCHEON,
making sure it is fully seated, rotate it to the desired
orientation, and securely tighten the SET SCREW.
7. Using the GASKET provided, hold the DIVERTER
PLATE against the finished wall then, using the
O-RING provided, thread and securely tighten the
ESCUTCHEON onto the THREADED TUBE.
4. Unthread the RETAINING COLLAR and remove
the CARTRIDGE then cut the CARTRIDGE STEM
1-7/8” [48mm] in front of the previous mark so
the STEM will protrude 1-7/8” [48mm] from the
finished wall surface.
5. Re-insert the CARTRIDGE then thread and securely
tighten the RETAINING COLLAR to the specified
torque setting shown and thread the THREADED
TUBE back into the RETAINING COLLAR until snug.
6. Loosen, but do NOT remove, the SET SCREW on
the backside of the GLAND COVER then remove
the GLAND COVER.
IMPORTANT: Do NOT use the GLAND COVER as
leverage to install the ESCUTCHEON.
CARTRIDGE
RETAINING
COLLAR
[27mm HEX]
[PREVIOUS
MARK]
CARTRIDGE
RETAINING COLLAR
(TORQUE - 15 to 18 ft-lb
[21 to 24 N m])
THREADED
TUBE
1-7/8”
[48mm]
CUT MARK
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15

WaterWorks RG2T01 Installation guide

Category
Sanitary ware
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI